| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAdmitted-Finance 143 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | L1 | Admitted-Finance | |
| 2 | L2₹1.3 Cr+₹1.8 L (1.40%)Admitted-Finance A 14 INDUSTRIAL HOUSE INDERPURI NEW DELHI 1100012 | NEW DELHI | NEW DELHI | DELHI | 110012 | L2 | Admitted-Finance | |
| 3 | L3₹1.3 Cr+₹2.8 L (2.18%)Admitted-Finance 46 LOWER GROUND FLOOR CHARMWOOD PLAZA EROS GARDEN FARIDABAD HARYANA 121009 | FARIDABAD | FARIDABAD | HARYANA | 121009 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Avon Engineering Company L1 | ace marketing pvt ltd L3 | MOHINI ELECTRICALS LTD. L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, erection and commissioning of 20Cs.V.T. mixed flow pump of 970 RPM, having static lift of 23 feet, including delivery pipe, delivery bends with support of minimum 8mm thickness with epoxy coating inside & outside including flange welding, nut-bolts, complete in all respect, as per site and as per approved technical specifications. | 2 | No | 25,31,000 ₹50,62,000 Lowest | 25,78,000 ₹51,56,000 | 25,87,000 ₹51,74,000 |
| 2.00 | Supply, erection and commissioning of solid shaft squirrel cage LT 3 phase 415v induction motor for continuous duty, vertical flange mounted of 1.00 HP of 8 pole, 740 rpm, TEFC Motor of IE (as per IS 12615 with latest amendments) suitable for 20Cs VT Pump complete in all respect and as per approved technical specifications. | 3 | No | 10,15,000 ₹30,45,000 | 9,95,000 ₹29,85,000 | 9,85,000 ₹29,55,000 Lowest |
| 3.00 | Supply, erection and commissioning of 11 KV VCB Panel consisting of 1 no 800 amp. incomer with 26.20 KA breaking capacity along with CT/PT of required capacity with 3 nos outgoing of 400 amp. each with CT of required capacity including the 2 4V DC operated relays for fault circuit, lighting loads, indicators, relays, meters, push buttons etc earth fault and overloading on all feeder and incomers. The scope of work also includes heavy duty battery operated charger for ensuring 24 hours relay operation and also includes the providing of pakka structure of size (20x20x12 feet) for the VCB | 1 | No | 49,15,000 ₹49,15,000 Lowest | 51,65,000 ₹51,65,000 | 50,75,000 ₹50,75,000 |
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
1 Sept 2026, 11:00 amClosed
Executive Engineer LWS Mech Div Charkhi Dadri
Executive Engineer LWS Mech Div Charkhi Dadri
Supply, erection and commissioning of 02 nos. 20 cs mixed/axial flow VT pump, 03 nos. 100 HP E/Motor and 01no VCB Panel of 800 ampere at PH-7 Loharu canal.
2026_HRY_542000_4
DNIT No. 6220-38/37-A dated 19.08.2026
Open Tender
Supply, Erection and Commissioning
Works
Charkhi Dadri
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
₹2.4 L
Yes
10 Sept 2026
19 Aug 2026
1 Sept 2026
19 Aug 2026
1 Sept 2026
19 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, erection and commissioning of 20Cs.V.T. mixed flow pump of 970 RPM, having static lift of 23 feet, including delivery pipe, delivery bends with support of minimum 8mm thickness with epoxy coating inside & outside including flange welding, nut-bolts, complete in all respect, as per site and as per approved technical specifications. | 2 | No | - | - |
| 2 | Supply, erection and commissioning of solid shaft squirrel cage LT 3 phase 415v induction motor for continuous duty, vertical flange mounted of 1.00 HP of 8 pole, 740 rpm, TEFC Motor of IE (as per IS 12615 with latest amendments) suitable for 20Cs VT Pump complete in all respect and as per approved technical specifications. | 3 | No | - | - |
| 3 | Supply, erection and commissioning of 11 KV VCB Panel consisting of 1 no 800 amp. incomer with 26.20 KA breaking capacity along with CT/PT of required capacity with 3 nos outgoing of 400 amp. each with CT of required capacity including the 2 4V DC operated relays for fault circuit, lighting loads, indicators, relays, meters, push buttons etc earth fault and overloading on all feeder and incomers. The scope of work also includes heavy duty battery operated charger for ensuring 24 hours relay operation and also includes the providing of pakka structure of size (20x20x12 feet) for the VCB | 1 | No | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.28 MB
bid4.pdf
Additional Documents • 8.97 MB
BOQ_621463.xls
BOQ • 0.25 MB
corrigendum.pdf
PDF • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .