| Sl No | Description | Qty | Unit | M/S SUMAN ENTERPRISES L2 | Nvimal Engineers and Contractor L1 |
|---|---|---|---|---|---|
| 1.00 | HT 33KVA OUTDOOR TYPE CT & PT
Material & Labour for removal of bushing & terminals and cleaning CT/PT 33 KV by CTC solution on its insulators and teeths and checking the leakage if any from the CT and refixing the same after replacing the defective/faulty parts and checking the oil level and oil dielectric strength (BD test) and proper connection checking/tightening of control wiring and testing with complete all as specified and directed by the Engineer-in-Charge of the following :-
(i) Meggar testing between phase to phase & phase to earth.
(ii) Testing the terminal connection and its working for the calibration and tripping of the relay for the protection of HT 33KV line. Make it functional to the entire satisfaction of and as directed by Enginer-in-charge | 1 | EACH JOB | 6,000 ₹6,000 | 5,000 ₹5,000 Lowest |
| 2.00 | Supply and fix in replacement of power pack for 33 KV VCB/RMU suitable for incoming supply 220/110 volts and output 110/24 volts DC supply all as per existing with wiring complete all as specified and directed by the Engineer-in-Charge.
Note : - The contractor has to visit the site to check the existing system of 33 KV VCB/RMU for installation of power pack unit. | 1 | EACH | 15,000 ₹15,000 Lowest | 15,500 ₹15,500 |
| 3.00 | Dismantaling top cover of transformer of capacity 1250 KVA , any make for repair / replacement of HT / LT bushing of transformer , or for replacement of top cover gasket or for inspection of transformer or for internal repairs of transformer all including draining transformer oil as required / upto the required level, re fitting the top cover of transformer after completion of the work including testing complete all as specified and directed by the Engineer-in-Charge.
Note - spare parts will be measured and paid seperatelly | 1 | EACH JOB | 4,000 ₹4,000 Lowest | 8,000 ₹8,000 |
| 4.00 | Material & Labour for replacement of defective silica gel breather with silica gel complete set 1250 KVA complete all as specified and directed by the Engineer-in-Charge. | 1 | EACH | 2,000 ₹2,000 Lowest | 3,000 ₹3,000 |
| 5.00 | Material & Labour for replacement of LT bushing of brass with neoprene rubber bush for Transformer 1250KVA capacities complete all as specified and directed by the Engineer-in-Charge. | 3 | EACH | 1,000 ₹3,000 Lowest | 1,250 ₹3,750 |
| 6.00 | Material & Labour for replacement of HT bushing of brass of transformer of capacity 1250 KVA. complete all as specified and directed by the Engineer-in-Charge. | 3 | EACH | 1,500 ₹4,500 | 1,250 ₹3,750 Lowest |
| 7.00 | Supply & filling of transformer oil in site for toping up the level of oil having dielectric strength between 55-65 KV during filling after initial filtration of any capacity complete all as specified and directed by the Engineer-in-Charge. | 110 | LITRE | 160 ₹17,600 | 110 ₹12,100 Lowest |
| 8.00 | Material & Labour for dehydration /filtration of transformer oil in existing pole mounted/floor mounted transformer/Voltage stabilizer with the help of dehydration/filtration machine to achieve the dielectric strength of transformer oil not less than 50 KV complete all as specified and directed by the Engineer-in-Charge.
Note:- (i) Dehydration/filtration machine will be arrange by the contractor and he will make his own arrangement and to carry the machine at various sub stations including vehicle and towing arrangement. The rate shall be inclusive of all above. | 1,700 | LITRE | 18 ₹30,600 | 12 ₹20,400 Lowest |
| 9.00 | Material & Labour for checking of HT 33KV cable of any size by means of HT Cable Fault Locator Machine by requisition for removal of HT cable faults complete all as specified and directed by the Engineer-in-Charge. | 1 | EACH JOB | 16,000 ₹16,000 | 13,500 ₹13,500 Lowest |
| 10.00 | Supply and fix in repair cable joint kit for 33 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 185 sqmm complete all as specified and directed by the Engineer-in-Charge. | 1 | EACH | 9,000 ₹9,000 | 7,000 ₹7,000 Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
25 Feb 2026, 6:00 pmClosed
CWE (AF) JODHPUR
HQ CWE AF JODHPUR Opp Mosam Vibhag Airforce Chauraha , Ratanada Jodhpur (Raj)-342011
REPAIR AND MAINT OF SOLAR POWER PLANT UNDER AGE E/M GE (AF) NO 2 JODHPUR.
2026_MES_751742_1
89135/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) No 2 Jodhpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) No 2 Jodhpur
₹30,000
Yes
28 Mar 2026
7 Feb 2026
27 Feb 2026
7 Feb 2026
25 Feb 2026
20 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | HT 33KVA OUTDOOR TYPE CT & PT
Material & Labour for removal of bushing & terminals and cleaning CT/PT 33 KV by CTC solution on its insulators and teeths and checking the leakage if any from the CT and refixing the same after replacing the defective/faulty parts and checking the oil level and oil dielectric strength (BD test) and proper connection checking/tightening of control wiring and testing with complete all as specified and directed by the Engineer-in-Charge of the following :-
(i) Meggar testing between phase to phase & phase to earth.
(ii) Testing the terminal connection and its working for the calibration and tripping of the relay for the protection of HT 33KV line. Make it functional to the entire satisfaction of and as directed by Enginer-in-charge | 1 | EACH JOB | - | - |
| 2 | Supply and fix in replacement of power pack for 33 KV VCB/RMU suitable for incoming supply 220/110 volts and output 110/24 volts DC supply all as per existing with wiring complete all as specified and directed by the Engineer-in-Charge.
Note : - The contractor has to visit the site to check the existing system of 33 KV VCB/RMU for installation of power pack unit. | 1 | EACH | - | - |
| 3 | Dismantaling top cover of transformer of capacity 1250 KVA , any make for repair / replacement of HT / LT bushing of transformer , or for replacement of top cover gasket or for inspection of transformer or for internal repairs of transformer all including draining transformer oil as required / upto the required level, re fitting the top cover of transformer after completion of the work including testing complete all as specified and directed by the Engineer-in-Charge.
Note - spare parts will be measured and paid seperatelly | 1 | EACH JOB | - | - |
| 4 | Material & Labour for replacement of defective silica gel breather with silica gel complete set 1250 KVA complete all as specified and directed by the Engineer-in-Charge. | 1 | EACH | - | - |
| 5 | Material & Labour for replacement of LT bushing of brass with neoprene rubber bush for Transformer 1250KVA capacities complete all as specified and directed by the Engineer-in-Charge. | 3 | EACH | - | - |
| 6 | Material & Labour for replacement of HT bushing of brass of transformer of capacity 1250 KVA. complete all as specified and directed by the Engineer-in-Charge. | 3 | EACH | - | - |
| 7 | Supply & filling of transformer oil in site for toping up the level of oil having dielectric strength between 55-65 KV during filling after initial filtration of any capacity complete all as specified and directed by the Engineer-in-Charge. | 110 | LITRE | - | - |
| 8 | Material & Labour for dehydration /filtration of transformer oil in existing pole mounted/floor mounted transformer/Voltage stabilizer with the help of dehydration/filtration machine to achieve the dielectric strength of transformer oil not less than 50 KV complete all as specified and directed by the Engineer-in-Charge.
Note:- (i) Dehydration/filtration machine will be arrange by the contractor and he will make his own arrangement and to carry the machine at various sub stations including vehicle and towing arrangement. The rate shall be inclusive of all above. | 1,700 | LITRE | - | - |
| 9 | Material & Labour for checking of HT 33KV cable of any size by means of HT Cable Fault Locator Machine by requisition for removal of HT cable faults complete all as specified and directed by the Engineer-in-Charge. | 1 | EACH JOB | - | - |
| 10 | Supply and fix in repair cable joint kit for 33 KV grade cable for outdoor termination Heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 185 sqmm complete all as specified and directed by the Engineer-in-Charge. | 1 | EACH | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.28 MB
TENDER89135.pdf
Tender Documents • 4.08 MB
BOQ_841954.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .