| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 CrAccepted-Finance | ₹16.2 Cr | L1 | Accepted-Finance Accepted because of lowest quoted amount. |
| 2 | L2₹16.7 CrRejected-Finance 102 SUBHASH ROAD HERITAGE HEIGHTS DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹16.7 Cr | L2 | Rejected-Finance Rejected because of higher quoted amount. |
| Sl No | Description | Qty | Unit | M/s Gautam Construction L1 | M/S Shiv Kumar Agarwal L2 |
|---|---|---|---|---|---|
| 1.00Site Development | |||||
| 2.00EARTHWORKS | |||||
| 3.00 | Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer-in-charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction | 320 | cum | 679 ₹2.2 L | 705 ₹2.3 L |
| 4.00 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. | 1,566.73 | cum | 894 ₹14.0 L | 926 ₹14.5 L |
| 5.00 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 7.5 Nominal mix (1:4:8) | 11.59 | cum | 7,181 ₹83,227.79 | 7,434 ₹86,160.06 |
| 6.00REINFORCED CEMENT CONCRETE | |||||
| 7.00 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 R.C.C. grade M 25 | 85.62 | cum | 11,059 ₹9.5 L | 11,448 ₹9.8 L |
| 8.00 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more. | 29,192.46 | kg | 138 ₹40.3 L | 142 ₹41.5 L |
| 9.00MASONRY WORK | |||||
| 10.00 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1 :6 (1 cement: 6 coarse sand) | 67.65 | cum | 11,617 ₹7.9 L | 12,026 ₹8.1 L |
Updated dates
Tender Value
₹16.3 Cr
EMD Value
₹32.5 L
Closing Date
27 Oct 2025, 3:00 pmClosed
Superintending Engineer, 7th Circle PWD Gopeshwar
Office of SE, 7th Circle PWD Gopeshwar
Construction of Pilgrim Accommodation Block-3 (Building R2H1 and R2H2) in Shri Badrinath Dham
2025_pwd_87807_1
3905/544 Yata-07/2025 Dated 29-09-2025
Open Tender
Civil Works - Buildings
540 days
Shri Badrinath Dham
Please Refer Tender Documents.
2 documents required · 2 mandatory
₹5,900
EE PIU PWD Badrinath
₹32.5 L
Office of SE, 7th Circle PWD Gopeshwar
18 Dec 2025
3 Oct 2025
27 Oct 2025
3 Oct 2025
27 Oct 2025
4 Oct 2025
10 Oct 2025
Amount
Site Development
EARTHWORKS
Excavation in foundation for retaining, breast walls etc, in all types of soils and rocks including all lead, lift and disposal of surplus material as per direction of engineer-in-charge, as per drawing and technical specifications Clause 305.1 of MORD Specifiction
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 7.5 Nominal mix (1:4:8)
REINFORCED CEMENT CONCRETE
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 R.C.C. grade M 25
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
MASONRY WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1 :6 (1 cement: 6 coarse sand)
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 6 mm
Stone work (machine cut edges) for wall lining etc. upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :Himalayan stone - exposed face fine dressed with rough backing 50 mm thick ( 450mm x 200mm) (Wall Cladding Stone)
ROAD WORK
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineerin- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing & making Gabion structure with Mechanically Woven Double Twisted Hexagonal Shaped Wire mesh Gabion Boxes as per IS 16014:2012,MORTH Clause 2500, of required size, Mesh Type 10x12 (D=100 mm with tolerance of ±2%), Zinic+10% Al alloy+PVC coated, Mesh wire diameter 2.7/3.7 mm (ID/OD), mechanically edged/selvedged with partitions at every 1m interval and shall have minimum 10 numbers of openings per meter of mesh perpendicular to twist, tying with lacing wire of diameter 2.2/3.2 mm(ID/OD), supplied @3% by weight of Gabion boxes, filled with boulders with least dimension of 200 mm, as per drawing, all complete as per directions of Engineer-in-charge.
Geotextile Filter (Laying of a geotextile filter between pitching and embankment slopes on which pitching is laid to prevent escape of the embankment material through the voids of the stone pitching/cement concrete blocks as well as to allow free movement of water without creating any uplift head on the pitching.)
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Granular Sub-base with Close Graded Material By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. for grading- I Material
Wet Mix Macadam laying Using Mechanical Paver ( Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub?base / base course on well prepared surface and compacting with vibratory roller to achieve the desired
Dry Lean Cement Concrete Sub-base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
NON-SCHEDULE ITEMS
70 mm thick fine dressed stone flooring for external works over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. Local Hammer dressed stone of size (450x350x70 )mm
Providing & Laying 80 mm thick Cement Concrete cobble stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand), side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Jet Black with minimum average 300kg/cm2 (100x100x80) mm (+-5% of size)
Providing and fixing cramps of required size & shape in RCC/ CC/Brick masonry backing with cement mortar 1 :2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps
HORTICULTURE
Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for
Grassing with ' Doobs' Grass (Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed) In rows 7.5 cm apart in either direction
Making Lawns including Ploughing and Dragging with 'Swagha' Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm.
BUILDING R2H1
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Ordinary rock
Hard Rock (Blasting prohibited)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
Supply and filling in plinth with sand under floos including watrering,ramming, consolidating and dressing complete
Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials. Ordinary or hard rock
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources :8 graded stone aggregate 20 mm nominal size derived from natural sources)
REINFORCED CEMENT CONCRETE
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg/cum
MASONRY WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1 :6 (1 cement: 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1 :4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
STONE WORK
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1 :6 (1 cement: 6 coarse sand)
CLADDING WORK
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 6 mm
Stone work (machine cut edges) for wall lining etc. upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Himalayan stone - exposed face fine dressed with rough backing 50 mm thick ( 450mm x 200mm) (Wall Cladding Stone)
WOOD AND P.V.C. WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc.(Sal Wood)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) 35 mm thick shutters (Second class teak wood)
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters. 25 mm to 40 mm thick. Second class teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters, 25 mm to 40 mm thick. Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I ) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (overall area of door shutter to be measured).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm, 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing & Fixing decorative high pressure laminated sheet of plain I wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
STEEL WORK
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
FLOORING
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand): 25 mm thick
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x300 mm(Anti Skid)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
ROOFING
12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
FINISHING
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
French spirit polishing : Two or more coats on new works including a coat of wood filler
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
WATER PROOFING
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
NON-SCHEDULE ITEMS
Providing and fixing cramps of required size & shape in RCC/ CC/Brick masonry backing with cement mortar 1 :2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps
Providing and fixing bright finished brass handles with screws etc. complete: Pull handle Model no-VISH GS Size 200 mm, (vintage brass)
Providing and fixing bright finished brass handles with screws etc. complete: Pull handle Model no-VISH AB Size 100 mm (vintage brass)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete Model no- VX Size (200x12) mm (vintage brass)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete Model no- VX Size (150x12)mm, (vintage brass)
Providing and fixing bright finished brass 250 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete Model No-Lever Handle Tango CY with Lock body and cylinder 60mm OSK
Providing and fixing bright finished brass mortice latch and a pair of lever handles of approved quality with necessary screws etc. complete Model No- Lever Handle Tango DY with BL-3 Latch for bathroom
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : Size (100x75x3) mm, (vintage brass)
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : Size (125x75x4) mm, (vintage brass)
Providing and fixing Brass casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Brass casement stays (straight peg type ) 200 mm weighing not less than 0.24 kg (vintage brass) Size 150 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Model No- DS 02 Size: 140 mm
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. Aluminium extruded section body tubular type universal hydraulic door closer DC 80 PDC
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. Sliding Bolt (300x16) mm, EX-02
Providing and fixing second class deodar wood hand rail having size of 75 mm x 65 mm with approved decorative shape etc.
Providing, laying and fixing of Second Class Deodar Wood as in built runner having size of 100mmX75 mm through out over masonary course during construction of wall as per detail drawing. It allows to apply adhesive on top and bottom of wood surface with additional fixing accessories of GI nut & bolt/ anchor fastners, nails, screws etc. to masonary work or provided RCC runner to protect against demormation with all due respect to complete the job. It allows providing and applying minimum two coats of approved water base PU polishing complete with required primer / sealer coat, rubbing, sand papering, powdering, etc. to exposed surface complete as per manufacturer specification.
Providing and fixing Deodar Wood ceiling in 25 mm thick 150 mm wide deodar wood plank.
Providing and fixing Second Class Deodar Wood Jhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank.
Providing and fixing 2nd class deodar wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.25mm thick
Two or more coats on new works including a coat of wood filler Hydro Oil For Exterior Coating
Supply, transportation, installation, fitting & fixing and supervision of Laminated Asphalt Shingles having multilayer Panel produce three dimensional profile and shadow lines with fiber glass mat, Waterproof, durable coating, temper proof, 110mph wind resistance, UL Class-A, fire resistance rating, exposure 5.5/ 8 inch, weight up to 450 Pound/ 100 Sqft. Or more, high end products last 30 years & more as per instructions laid on ASTM D3462, ASTM D3018, ASTM D7158-Class-H. The Laminated Asphalt Shingles as per specifications must be laid in proper way over 20mm Cement Fiber Board Make - Everest or Equivalent. and moisture barrier membrane and Algae resistant Ridge with all required fixtures & fastenings as a complete job as per instructions and satisfaction of Engineer-in-charge with contractors’ own material, labour, tools, lead, lift, T&P, etc. The design and methodology to be approved by Engineer-in-charge prior commencement of the work. The rate included cost of materials, transportation to site, installation, fixing, pegging, pre-installation preparation works, supervision, petty works involved, taxes, GST, etc. as a compete job.
BUILDING R2H2
EARTH WORK
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. Ordinary rock
Hard Rock (Blasting prohibited)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
Supply and filling in plinth with sand under floos including watrering,ramming, consolidating and dressing complete
Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation/ banking excavated or stacked materials. Ordinary or hard rock
CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources : 8 graded stone aggregate 20 mm nominal size derived from natural sources)
REINFORCED CEMENT CONCRETE
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg/cum
MASONRY WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1 :6 (1 cement: 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1 :4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6 mm dia. M.S. bars at every third course of half brick masonry.
STONE WORK
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1 :6 (1 cement: 6 coarse sand)
CLADDING WORK
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 6 mm
Stone work (machine cut edges) for wall lining etc. upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately). Himalayan stone - exposed face fine dressed with rough backing 50 mm thick (450mm x 200mm) (Wall Cladding Stone)
WOOD AND P.V.C. WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal wood
Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. (Sal Wood)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) 35 mm thick shutters (Second class teak wood)
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Second class teak wood
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. Float glass panes 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm).
Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick (weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured).
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I ) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISi marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm, 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
Providing & Fixing decorative high pressure laminated sheet of plain I wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
STEEL WORK
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
FLOORING
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand): 25 mm thick
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x300 mm (Anti Skid)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I . S . 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 1 2 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 1 8 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 :4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
ROOFING
12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
FINISHING
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
French spirit polishing : Two or more coats on new works including a coat of wood filler
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
WATER PROOFING
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
NON-SCHEDULE ITEMS
Providing and fixing cramps of required size & shape in RCC/ CC/ Brick masonry backing with cement mortar 1 :2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel cramps
Providing and fixing bright finished brass handles with screws etc. complete: Pull handle Model no-VISH GS Size 200 mm, (vintage brass)
Providing and fixing bright finished brass handles with screws etc. complete: Pull handle Model no-VISH AB Size 100 mm (vintage brass)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete Model no- VX Size (200x12) mm (vintage brass)
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete Model no- VX Size (150x12)mm, (vintage brass)
Providing and fixing bright finished brass 250 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete Model No-Lever Handle Tango CY with Lock body and cylinder 60mm OSK
Providing and fixing bright finished brass mortice latch and a pair of lever handles of approved quality with necessary screws etc. complete Model No- Lever Handle Tango DY with BL-3 Latch for bathroom
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : Size (100x75x3) mm, (vintage brass)
Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : Size (125x75x4) mm, (vintage brass)
Providing and fixing Brass casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Brass casement stays (straight peg type ) 200 mm weighing not less than 0.24 kg (vintage brass) Size 150 mm
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Model No- DS 02 Size: 140 mm
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. Aluminium extruded section body tubular type universal hydraulic door closer DC 80 PDC
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete. Sliding Bolt (300x16) mm, EX-02
Providing and fixing second class deodar wood hand rail having size of 75 mm x 65 mm with approved decorative shape etc.
Providing, laying and fixing of Second Class Deodar Wood as in built runner having size of 100mmX75 mm through out over masonary course during construction of wall as per detail drawing. It allows to apply adhesive on top and bottom of wood surface with additional fixing accessories of GI nut & bolt/ anchor fastners, nails, screws etc. to masonary work or provided RCC runner to protect against demormation with all due respect to complete the job. It allows providing and applying minimum two coats of approved water base PU polishing complete with required primer / sealer coat, rubbing, sand papering, powdering, etc. to exposed surface complete as per manufacturer specification.
Providing and fixing Deodar Wood ceiling in 25 mm thick 150 mm wide deodar wood plank.
Providing and fixing Second Class Deodar Wood Jhalar (Manually Hand Carved) in 25 mm thick 300 mm wide deodar wood plank.
Providing and fixing 2nd class deodar wood plain lining tongued and grooved, including wooden plugs complete with necessary screws and priming coat on unexposed surface.25mm thick
Two or more coats on new works including a coat of wood filler Hydro Oil For Exterior Coating
Supply, transportation, installation, fitting & fixing and supervision of Laminated Asphalt Shingles having multilayer Panel produce three dimensional profile and shadow lines with fiber glass mat, Waterproof, durable coating, temper proof, 110mph wind resistance, UL Class-A, fire resistance rating, exposure 5.5/ 8 inch, weight up to 450 Pound/ 100 Sqft. Or more, high end products last 30 years & more as per instructions laid on ASTM D3462, ASTM D3018, ASTM D7158-Class-H. The Laminated Asphalt Shingles as per specifications must be laid in proper way over 20mm Cement Fiber Board Make - Everest or Equivalent. and moisture barrier membrane and Algae resistant Ridge with all required fixtures & fastenings as a complete job as per instructions and satisfaction of Engineer-in-charge with contractors’ own material, labour, tools, lead, lift, T&P, etc. The design and methodology to be approved by Engineer-in-charge prior commencement of the work. The rate included cost of materials, transportation to site, installation, fixing, pegging, pre-installation preparation works, supervision, petty works involved, taxes, GST, etc. as a complete job.
Civil Works for PHE
LAYING PIPES
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Sand filling
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 20 mm nominal size)
RCC MANHOLE :
Providing and fixing in position FRP Recessed Cover with frame 600mm x 600mm, Capacity 25 Ton of required Shape & approved quality. pre-cast R.C.C. manhole cover and frame of required shape and approved quality
600 x 600 mm size 0 to 1.0mtr depth
900 x 800 mm size 0 to 1.5mtr depth
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soils / ordinary rock
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and ,reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 Kgs/CuM. Excess/ less cement used as per design mix is payable/recoverable separately).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 20 mm nominal size)
Form Work : Centring and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete
Centring and Shuttering for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centring and Shuttering for Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
GULLY TRAPS
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar
Providing and fixing square-mouth S.W. gully trap class SP-1 complete,with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less standard design: than 4.50 Kgs and frame to be not less than 2.70 Kgs as per standard design: 180x150 mm size P type (refer typical section drawing) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
DEMOLITION WORKS
Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
SEPTIC TANK
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soils / ordinary rock
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 20 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 Kgs/Cum. Excess/ less cement used as per design mix is payable/recoverable separately).
Form Work : Centring and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete
Centring and Shuttering for Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
20 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand)
Providing and fixing in position FRP Recessed Cover with frame 600mm x 600mm, Capacity 25 Ton of required Shape & approved quality. pre-cast R.C.C. manhole cover and frame of required shape and approved quality
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Civil Works for Electrical
RCC MANHOLE :
Providing and fixing in position FRP Recessed Cover with frame 600mm x 600mm, Capacity 25 Ton of required Shape & approved quality. pre-cast R.C.C. manhole cover and frame of required shape and approved quality
ELECTRICAL MANHOLES
EM-AA-600x600x1200mm ELECTRICAL & ELV MANHOLE
EM-B-600x600x1000mm ELECTRICAL MANHOLE
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soils / ordinary rock
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 Kgs/CuM. Excess/ less cement used as per design mix is payable/recoverable separately).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 20 mm nominal size)
Form Work : Centring and Shuttering for Foundations, footings, bases of columns, etc. for mass concrete
Centring and Shuttering for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centring and Shuttering for Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
PLUMBING WORK
Sanitary Fixutures and Fittings
Providing and fixing wash down wall mounting EWC-P of approved shade, conforming to Pattern 2 of IS: 2556 (Part -II), with pipe and plug bend as per specifications; glazed vitreous / Coloured European Water Closet with metropole flush valve, with grouting the CI chair in side the floor/wall, rubber gaskets, connecting PVC 110mm dia soil pipe with PVC coupling, nuts, mounting cistern on WC.,1 No.CPVC connection with brass union nuts CP coated and solid verity heavy duty plastic seat cover as per IS-2548, of approved make; including painting of fittings and brackets, cutting and making good the walls wherever require: etc. complete. The rates including cost and conveyence of all materials, labour, machinery etc. EWC-P with Soft close Seat cover : Jaquar, Model No: CNS-WHT-959SPP Metropole flush valve Dual flow : Jaquar, Model No: FLV-1085NG
Providing and fixing of 3 in 1 wall mixer system with provision for overhead shower complete with bend pipe including necessary fittings with wall flange etc complete in all respects including cutting and making good the walls etc. SHOWER HEAD: Jaquar MODEL NO. OHS-CHR-1789 SHOWER ARM Jaquar MODEL NO. SHA-487 WALL MIXER Jaquar MODEL NO. FUS-29273UPR
Providing and fixing White glazed vitreous Wash Basin Oval Under-Counter, size 560 x 430 x 195 mm dia., with supporting M.S. or C.I. Brackets, necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 mm thick fixed on Black Kadappa Framework, Waste coupling 32 mm size full thread with 80 mm height Chrome plated, Bottle trap Chrome plated Basin Mixer necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. OVAL UNDER COUNTER BASIN: Jaquar , Model No: FLS-WHT-5701 WASTE COUPLING : Jaquar , Model No: ALD-CHR-705 BOTTLE TRAP : Jaquar , Model No: ALD-769L300X190 Basin Mixer: Jaquar , Model No: FLR-5001B
Providing and fixing 15mm C.P. brass angle valve with C.P. copper connecting pipe 450 mm long and nuts, washer and brass flange complete, including cutting and making good the wall where required. ANGLE VALVE : Jaquar, Model No. FLR-5053N BRAIDED HOSE Copper Pipe : Jaquar, Model no. ALD-CHR-805B
Providing and fixing in position 15 mm C.P. brass long body bib cocks of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. BIB COCK : Jaquar Continental, Model No: CON-107KN
Providing and fixing of Hand Shower (Health Faucet), with 8mm Dia,1.2 Rmt Long pvc Tube and Wall Hook accessories of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. HAND SHOWER : Jaquar , Model No: ALD-573
Providing and fixing in position best Indian make toilet recessed type paper holder complete in all respects including cutting and making good the walls etc. TOILET PAPER HOLDER : Jaquar , Model No: AHS-1553
Providing & fixing C.P. brass towel ring fixed to rawl plug with C.P. brass screws. TOWEL RING : Jaquar Continental, Model No.: ACN-1121BN
Providing and fixing C.P. brass liquid soap container of best quality. LIQUID SOAP CONTAINER: Jaquar , Model No: SDR-WHT-DJ0010F
Providing and fixing in position best Indian make C.P. brass twin way QUOTE and hat hooks fixed into wall with C.P. Brass screws and rawlplugs etc. complete including cutting and making good the walls etc. DOUBLE QUOTE HOOKS: Jaquar, Model No: -ACN-1161N
Providing and fixing of electrical type water Geyser inclusing all required accessories cutting, chassing and good the same. 25 Litre Storage, Make: Jaquar Elena vertical
Providing and fixing in position 15 mm C.P. brass bib cocks of best quality necessary fittings with wall Flange etc. complete in all respects including cutting and making good the walls etc. BIB COCK : Jaquar Fusion , Model No. FUS-29037
Providing & fixing towel rail of approved make including, providing & fixing C.P. brass screws, making holes in walls & making good. TOWELRAIL: Jaquar Continental, Model No. ACN-1111SM
Fixing stainless steel recessed type soap dish of approved make. Including providing & fixing screws, washers, cutting & making good the walls. SOAP DISH : Jaquar, Model No: AKP-35731P
Internal & External Drainage Work
Providing, installation, testing and commissioning of 50 mm dia. Acoustic Multilayer Polyproplene pipe conforming to BS EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP and one layer fittings in PP MD, Push fit/ Ring fit type, Halogen and Cadmium free, having high impact resistance as per DIN EN ISO 291:2008-08, Fire resistancy DIN 4102 B2, Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of 21 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15 to 1.25 gms/cm3, elongation = 0.09mm/mn/K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring, Fire Behavior Classification according to EN 13501-1:2009 & classified D-s2-d2 (EN 13501-1), meets the requirements of EN 4102-2 with Fire Classification B2, Smoke Development Category Q1 & Drip Formation category TR1. The scope shall be Including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs, fixing waste pipes to the floor with concrete bedding for full length etc. including cutting holes in walls, slab and beam, chasing the wall by grinder cutter, including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/ channels with U-bolts, etc) as per detail technical specification etc. complete the job and making good the same etc. complete the job as directed by Engineer in charge. (Soil, Waste & Vent Pipe)
Providing, installation, testing and commissioning of 75 mm dia. Acoustic Multilayer Polyproplene pipe conforming to BS EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP and one layer fittings in PP MD, Push fit/ Ring fit type, Halogen and Cadmium free, having high impact resistance as per DIN EN ISO 291:2008-08, Fire resistancy DIN 4102 B2, Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of 21 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15to1.25 gms/cm3, elongation = 0.09mm/mn/K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring, Fire Behavior Classification according to EN 13501-1:2009 & classified D-s2-d2 (EN 13501-1), meets the requirements of EN 4102-2 with Fire Classification B2, Smoke Development Category Q1 & Drip Formation category TR1. The scope shall be Including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs, fixing waste pipes to the floor with concrete bedding for full length etc. including cutting holes in walls, slab and beam, chasing the wall by grinder cutter, including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/ channels with U-bolts, etc) as per detail technical specification etc. complete the job and making good the same etc. complete the job as directed by Engineer in charge. (Soil, Waste & Vent Pipe)
Providing, installation, testing and commissioning of 110 mm dia. Acoustic Multilayer Polyproplene pipe conforming to BS EN 1451-Part 1-6 with 3 layer pipe made of PP + PP-MD + PP and one layer fittings in PP MD, Push fit/ Ring fit type, Halogen and Cadmium free, having high impact resistance as per DIN EN ISO 291:2008-08, Fire resistancy DIN 4102 B2, Ring stiffness SN6 6KN/m2 as per ISO 9969, offering sound levels of 21 dBA as per EN 14366 at a flow rate of 4 l/s, water tightness as per EN 1451-1 minimum of 0.5 bar for 15 minutes, density of pipe = 1.15to1.25 gms/cm3, elongation = 0.09mm/mn/K and E modulus 2300-3000 as per ISO 178, along with factory fitted EPDM lip ring, Fire Behavior Classification according to EN 13501-1:2009 & classified D-s2-d2 (EN 13501-1), meets the requirements of EN 4102-2 with Fire Classification B2, Smoke Development Category Q1 & Drip Formation category TR1. The scope shall be Including all fittings such as bends, junctions, inspection doors, offsets, cowl, access pieces/plugs etc. including cutting holes in walls, slab and beam, chasing the wall by grinder cutter, including all the engineered support (support, hanger, nuts/bolts, anchor fasteners, fixing clamp/ channels with U-bolts, etc) as per detail technical specification etc. complete the job and making good the same etc. complete the job as directed by Engineer in charge. The scope shall be also include Providing and laying 100mm thickness cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded stone aggregate 40 mm nominal size) around the pipe etc. complete the job as directed by Engineer in charge. (Soil, Waste & Vent Pipe)
Supply, installation, testing and commissioning of Polypropylene (PP) 110mm x 110mm size P trap with necessary of self cleaning design with water seal with and without vent arm jointing with push fit rubber ring socket fittings complete, as required height riser for basin/ sink/ Urinal drain connection with necessary distance piece of pipe, inlet hopper with two or three inlets fittings to receive waste pipes from fixtures waste and hopper shall be Manufactured from 110 mm dia. up to 600 mm long, etc., cutting chases/ hole in floors/ slabs and bringing the same in proper condition and shape after placing the trap in right position in case of suspended/ open plumbing or setting the trap in 1:2:4 CC in case of concealed plumbing, etc. complete the job as directed by Engineer in charge.
Providing and fixing PTMT grating of Rectangular type with openable circular lid of 150mm nominal size square 100 mm diameter of the inner hinged round grating of approved quality and colour.
Providing and fixing of 125 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge.
Providing and fixing of 180 mm Outer dia HDPE PE 100, PN-6 SEWER pipes confirming to IS:14333-2000, fusion welded Joint, including all fittings,special, testing of joints, including trenching, refilling & testing of joints etc. complete as per direction of Engineer-in-Charge.
Internal & External Water Supply Work
Providing and fixing of 20 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work,including cutting chases and making good the wall etc.
Providing and fixing of 20 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 25 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 32 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 40 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 50 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS 15801, UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineerin- Charge. Internal Exposed on walls
Providing and fixing of 63 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.
Providing and fixing of 75 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.
Providing and fixing of 90 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.
Providing and fixing of 110 mm Outer dia 3 layer PP-R (Poly propylene Random copolymer) pipes confirming to IS:15801 UV stabilized & anti - microbial fusion welded, having thermal stability for hot & cold water supply, including all PP - R plain & brass threaded polypropylene random fittings, including trenching, refilling & testing of joints complete as per direction of Engineer-in-Charge.
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 25 dia pipe
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 32 dia pipe
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 40 dia pipe
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 50 dia pipe
Providing and fixing 9 mm thick preformed syntheic rubber polymeric compound prefromed sleeves with all accessories & clamp, support , etc. (Inside Toilet) for 65 dia pipe
Supplying, laying/ fixing, testing and commissioning of following 50mm thickness resin bonded fiber glass pipe section insulation having density 80 kg/cum or mineral wool (non combustible) having density of 144 Kg/ cu m duly covered with a layer of 120 gm/sqm polythene sheet (vapour barrier) on pipe and finally applying 0.63mm aluminium sheet cladding complete with type 3, grade 1 roofing feltstrip (as per IS:1322 as amended up to date) at joints etc. as per specifications and as required.
Providing and fixing of 20mm diameter gun metal gate valve with C.I. wheel of approved quality
Providing and fixing of 25mm diameter gun metal gate valve with C.I. wheel of approved quality
Providing and fixing of 32mm diameter gun metal gate valve with C.I. wheel of approved quality
Providing and fixing of 40mm diameter gun metal gate valve with C.I. wheel of approved quality
Supplying, fixing, testing and commissioning of 50mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified.
Supplying, fixing, testing and commissioning of 65mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified.
Supplying, fixing, testing and commissioning of 80mm diameter butterfly valve (manual) with C I body SS Disc, Nitrile Rubber Seal & Oring PN 16 pressure rating as specified.
Providing and fixing non-return valve of 65 mm dia with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.
Supply, Installation, Testing and Commissioning of 25 mm dia. air release valve.
Providing and fixing 25mm dia float valve with pressure type PTMT float valve. (Make: Prayag)
Supply, intallation, Testing and Commisioning of 20mm diameter Garden Hydrant with gun metal Ball Valve, Flexinble hose Connection Provision and all required accessories etc
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.
Supplying and fixing 50mm thick aluminium foil faced resin bonded fibre glass insulation (for polyethylene water storage tank) of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/cum after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape & covering with 0.63mmx19mm GI wire mesh netting & butting all joints and laced with GI wire complete and finally covered with one layer of tar felt stuck with hot bitumen as per specifications and as required. (for outdoor applications)
Supplying, fitting & fixing of 65mm dia Pressure Reducing Valve set of approved make & best quality having by-pass valve arrangement including of 3 nos isolation valve.
Fire Extinguisher
6 Kg ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc.
ISI Marked portable fire extinguisher, 4.5 kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform to IS 2878 Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc.
M/S Shiv Kumar Agarwal (BID ID -403753)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.53 MB
PAB3SBD2ndtime.pdf
Tender Documents • 5.11 MB
BOQ_104224.xls
BOQ • 0.46 MB
SUDHHIPATRA.pdf
Other Document • 0.19 MB
Download all tender documents and submit your bid