| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.9 L+₹43,621 (1.94%)Rejected-AOC | L2 | Rejected-AOC Not Being L1 | |
| 3 | L3₹23.7 L+₹1.3 L (5.68%)Rejected-AOC | L3 | Rejected-AOC Not Being L1 | |
| 4 | L4₹24.1 L+₹1.6 L (7.07%)Rejected-AOC | L4 | Rejected-AOC Not Being L1 | |
| 5 | L5₹27.1 L+₹4.7 L (20.7%)Rejected-AOC NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | L5 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | Sri Balaji Enterprises L4 | Shreshta Associates L3 | Srinivasa Consructions L6 | SUN LIGHT HOUSE L2 | SRI SAI RAM ENTERPRISES L1 | THE DECAN ENGINEERING AND REFRIGERATION COMPANY L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling all as specified & directed by Engr in Charge. | 1,697 | Point | 5 ₹8,485 Lowest | 15 ₹25,455 | 20 ₹33,940 | 10 ₹16,970 | 5 ₹8,485 Lowest | 30 ₹50,910 |
| 2.00 | Disconnecting and removing the MCB DBs/AC Box from any height, stripping out the fitting for examine replacement of un serviceable spare parts, reassembling, refixing in original position including minor repairs for the smooth functioning and testing complete all as specified & directed by Engg in Charge. | 40 | Each | 19 ₹760 | 20 ₹800 | 30 ₹1,200 | 10 ₹400 Lowest | 10 ₹400 Lowest | 30 ₹1,200 |
| 3.00 | Taking down old submain wiring of any size and type complete all as specified and directed by Engr in Charge. | 760 | RM | 10 ₹7,600 | 5 ₹3,800 | 2 ₹1,520 Lowest | 5 ₹3,800 | 5 ₹3,800 | 10 ₹7,600 |
| 4.00 | M&L Concealed point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed.
Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate. | 420 | Point | 700 ₹2,94,000 | 600 ₹2,52,000 Lowest | 900 ₹3,78,000 | 650 ₹2,73,000 | 625 ₹2,62,500 | 750 ₹3,15,000 |
| 5.00 | All as per Item No. 4 above, but one light point controlled by two way switches. | 10 | Point | 700 ₹7,000 | 600 ₹6,000 Lowest | 900 ₹9,000 | 700 ₹7,000 | 625 ₹6,250 | 750 ₹7,500 |
| 6.00 | All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board . | 60 | Point | 700 ₹42,000 | 650 ₹39,000 | 900 ₹54,000 | 650 ₹39,000 | 625 ₹37,500 Lowest | 750 ₹45,000 |
| 7.00 | All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. | 25 | Point | 310 ₹7,750 | 230 ₹5,750 | 300 ₹7,500 | 300 ₹7,500 | 180 ₹4,500 Lowest | 250 ₹6,250 |
| 8.00 | All as per Item No. 4 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor Note: Modular cover plate with frame and modular metal flux box and cutting/chases included in the rate quoted. | 30 | Point | 730 ₹21,900 | 850 ₹25,500 | 1,000 ₹30,000 | 850 ₹25,500 | 725 ₹21,750 Lowest | 900 ₹27,000 |
| 9.00 | M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc, for one light/fan point controlled by one switch complete all as specified and directed.
Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate. | 338 | Point | 600 ₹2,02,800 | 590 ₹1,99,420 | 800 ₹2,70,400 | 550 ₹1,85,900 | 525 ₹1,77,450 Lowest | 650 ₹2,19,700 |
| 10.00 | All as per Item No. 9 above, but one light point controlled by two way switches. | 10 | Point | 600 ₹6,000 | 590 ₹5,900 | 800 ₹8,000 | 600 ₹6,000 | 525 ₹5,250 Lowest | 650 ₹6,500 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
20 Nov 2025, 6:00 pmClosed
Shri Rajesh Kumar Meena, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
REPAIRS REPLACEMENT OF INTERNAL WIRING WITH CONNECTED ITEMS INCLUDING FITTINGS AND FIXTURES AT ZONE A AREA UNDER AGE EM (N) OF GE (NORTH) SECUNDERABAD
2025_MES_737707_1
8963
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer North Secunderabad
₹64,000
Yes
13 Feb 2026
30 Oct 2025
27 Nov 2025
30 Oct 2025
20 Nov 2025
13 Nov 2025
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling all as specified & directed by Engr in Charge.
Taking down old submain wiring of any size and type complete all as specified and directed by Engr in Charge.
M&L Concealed point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories concealed in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRSH unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed. Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate.
All as per Item No. 4 above, but one light point controlled by two way switches.
All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Item No. 4 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 4 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor Note: Modular cover plate with frame and modular metal flux box and cutting/chases included in the rate quoted.
M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC rigid conduit medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc, for one light/fan point controlled by one switch complete all as specified and directed. Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate.
All as per Item No. 9 above, but one light point controlled by two way switches.
All as per Item No. 9 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Item No. 9 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 9 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor
M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic PVC casing caping medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/sockets/fan regulators etc,for one light/fan point controlled by one switch complete all as specified and directed. Note : Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate.
All as per Item No. 14 above, but one light point controlled by two way switches.
All as per Item No. 14 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Item No. 14 above, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 14 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor
M&L Surface point wiring for any length with 1100 volts grade 1.5 sqmm PVC insulated FRLS unsheathed cable with multistrandard copper conductor with ISI marking and including non-metallic existing PVC conduit medium grade of size minimum 20 mm with all accessories in wall/ceiling including continuous earth wire 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor connected to common earth and earth dolly including modular metal flush boxes concealed in wall and modular white plate covers with frame for mounting of modular switches/ sockets/ fan regulators etc, for one light/fan point controlled by one switch complete all as specified and directed. Note: Wiring from the DB (distribution box) to switch and sunken modular flush sheet metal enclosures and modular cover plates shall be deemed inclusive in the quoted rate.
All as per Item No. 19 above, but one light point controlled by two way switches.
All as per Item No. 19 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Item No. 19 above, but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Item No. 19 above, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor
S & F Modular switch 1 way 6/10 Amps, 1 Module complete all as specified and directed.
S & F Modular switch 2 way 6/10 Amps, 1 Module complete all as specified and directed.
S & F Modular switch 1 way 16/20 Amps, 1 Module complete all as specified and directed.
S&F Modular Bell Push 10A, 1 Module complete all as specified and directed.
S&F Socket outlet modular type multipurpose 2/3 Pin, 6 amps, 230 volts combined 2 Module complete all as specified and directed.
S&F Socket outlet modular type multipurpose 2/3 Pin, 6/16 amps, 230 volts combined 2 Module complete all as specified and directed.
S & F Modular ceiling fan regulator stepped type heavy duty suitable to work on 230 volts, 2 Module complete all as specified and directed.
S & F Switch piano single pole flush type 5 amps, 230 volts complete all as specified and directed.
S&F Bell push 5 A flush type complete all as specified and directed.
S&F Socket outlet flush type multipurpose 2 in 1, 5 Pin, 5 amps, 230 volts complete all as specified and directed.
S & F Switch socket combination flush type multipurpose 2/5 pin 5 amps 2 in 1 230 Volts complete all as specified and directed.
S & F Switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type with complete all as specified and directed.
S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed.
S & F Electronic type regulator stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified and directed.
S & F Angle holder insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and directed.
S&F Bell ding dong working on 230 volts AC Supply complete all as specified and directed.
S&F in replacement of Surface mounted Downlighter 15W with ABS housing and PC Opal diffuser with integral electronic LED driver complete with all accessories complete all as specified and directed.
S&F in replacement of Decorative box type surface and wall mounted 4' LED batten 20w with tube and polycarbonate housing & integrated electronic drive etc.complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement of Wall mounted LED Batten, extruded powder coated aluminum housing heat sink provided for efficient heat dissipation & integrated electronic driver 1x10W, 230 Volts, DIFFUSED TYPE connector block, internally pre wired etc including new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed.
S&F in replacement of LED security Light luminaire 25 watts with deep drawn housing including all accessories and Lamp, with suitable pipe bracket 25 mm dia 0.60 Mtr length fixed on wall with suitable flat iron clamps and nut bolts complete all as specified and directed.
S&F in replacement of Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head 10W edge-lit LED luminaire comprising of high brightness LEDs including taking down unserviceable fitting all as specified and directed.
S&F in replacement of Wall light including 9 Watt LED Bulb, Environmental friendly, ultra modern, energy saving, surface mounted complete all as specified and directed.
Supply and fix in replacement of MCB SP 6 to 32 Amps 240 volts, 'B' curve for fixing on MCB DB's complete all as specified and directed.
S & F in replacement of MCB SPN 40 to 63 Amps 240 'C' curve volts for fixing on MCB DB's complete all as specified and directed.
S & F in replacement of MCB Four pole, 415 volts, 'C' curve suitable for fixing on MCB DB of capacity 40 to 100 Amps complete all as specified and directed.
S & F Sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified
S & F in replacement of Horizontal type TPN DB 4 way double door made out of CRCA sheet housing with powder coating & confirming to IS 13032, IS 8623, BS 5486 accommodated suitably in a MS enclosure weather proof made out of 3 mm thick MS sheet having hinged and robust locking arrangement including painting by red-oxide one coat and powder coated complete all as specified and directed.
S & F in replacement of Modular Single pole and Neutral enclosure (Modular AC Box) with a two pin and earth plug and socket complete with one single pole MCB 25 Amps (AC Box) complete all as specified and directed.
M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
M&L Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm complete all as specified and directed.
S& F Inner plate 1 Module complete all as specified and directed.
S& F Inner plate 2 Module complete all as specified and directed.
S& F Inner plate 3 Module complete all as specified and directed.
S& F Inner plate 6 Module complete all as specified and directed.
S& F Inner plate 8 Module complete all as specified and directed.
S& F Inner plate 12 Module complete all as specified and directed.
S& F Outer plate 1 Module complete all as specified and directed.
S& F Outer plate 2 Module complete all as specified and directed.
S& F Outer plate 3 Module complete all as specified and directed.
S& F Outer plate 6 Module complete all as specified and directed.
S& F Outer plate 8 Module complete all as specified and directed.
S& F Outer plate 12 Module complete all as specified and directed.
S&F Surface Mounting Plastic Boxes 1 Module complete all as specified and directed.
S&F Surface Mounting Plastic Boxes 2 Module complete all as specified and directed.
S&F Surface Mounting Plastic Boxes 3 Module complete all as specified and directed.
S&F Surface Mounting Plastic Boxes 6 Module complete all as specified and directed.
S&F Surface Mounting Plastic Boxes 8 Module complete all as specified and directed.
S&F Surface Mounting Plastic Boxes 12 Module complete all as specified and directed.
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
8963tender.pdf
Tender Documents • 1.12 MB
BOQ_826025.xls
BOQ • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .