Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹17.4 LAccepted-AOC | L-1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L-2₹19.6 L+₹2.0 L (11.6%)Rejected-Finance 1017 A SUBHASH NAGAR BEHIND KHALSA SCHOOL BAREILLY UP | BAREILLY | UTTAR PRADESH | 243001 | L-2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L-3₹19.6 L+₹2.1 L (11.7%)Rejected-Finance | L-3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L-4₹21.0 L+₹3.4 L (19.4%)Rejected-Finance 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L-4 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
Refer Docs
EMD Value
₹45,400
Closing Date
18 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Air Force, Bareilly
Garrison Engineer, Air Force, Bareilly, 243002
PROVISION OF DEFICIENT GEYSERS WITH ACCESSORIES IN CERTAIN OMQs/ SMQs, SPECIAL REPAIRS TO ELECTRICAL CONNECTIONS FROM LT BOX TO FIRE PROOF SWITCHES IN SNOW TIGERS DSS AND TECH FLT HANGERS AND CERTAIN REVENUE/ MINOR WORKS AT AF STN, BAREILLY
2020_MES_406445_1
8567 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Bareilly
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹45,400
Yes
8 Feb 2021
23 Dec 2020
20 Jan 2021
23 Dec 2020
18 Jan 2021
6 Jan 2021
60 days
Amount
Taking down carefully burnt out/ un serviceable sub main copper/ aluminium wiring of any sizes on conduit/ batten complete all as specified and as directed.
S&F 1100 volts grade heavy duty four single core 16 Sq.mm size (Nominal Area) PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including mild steel ERW conduit ISI marked not less than 40mm dia with necessary fittings, fixed on surface along with a continuous one run of 16 Sq.mm size (Nominal size) stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - FOUR SINGLE CORE CABLES ALONG WITH ONE RUN OF EARTH WIRE AND MS CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S&F 1100 volts grade heavy duty four single core 10 Sq.mm size (Nominal Area) PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including mild steel ERW conduit ISI marked not less than 40mm dia with necessary fittings, fixed on surface along with a continuous one run of 10 Sq.mm size (Nominal size) stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - FOUR SINGLE CORE CABLES ALONG WITH ONE RUN OF EARTH WIRE AND MS CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S&F flame proof, weather proof direct entry type rotary switch with cable terminal box in cast aluminium alloy LM-6 enclosure epoxy powder coated TP ON/OFF 1¼" ET entries up to 4x16 Sq.mm copper cable, 63 Amp ON/OFF switch AC certified by CRMI for group II-A & II-B including compression glands complete all as specified and directed including taking down existing unserviceable switch. Make:- Sudhir Cat Part No DOLS/187 FLP Rotary Switch or equivalent in Baliga/ Shyam/ Bajaj.
S&F in repairs MCCB 125 Amp, 415 volts, 4 pole, Thermal magnetic release for line protection etc complete all as specified and directed.
S&F of Flame proof, weather proof direct entry type rotary switch with cable terminal box in cast aluminium alloy LM-6 enclosure epoxy powder coated single pole 230 volts 16 Amp ON / OFF switch AC certified by CRMI for group II-A & II-B including compression glands complete all as specified and directed including taking down existing unserviceable switch. Make:- Sudhir/ Baliga/ Shyam/ Bajaj.
S&F Flame proof - weather proof MCB socket & plug combined 16 A, 500 V (3P+Earth) complete all as specified and as directed including taking down existing unserviceable socket. Make:- Sudhir/ Baliga/ Shyam/ Bajaj.
Cutting existing GI pipe of size 20/25/40mm bore in position for insertion of new tees, branches etc including connection complete all as specified and directed.
S&F 20mm dia stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for unions/ sockets and fixed complete all as specified and as directed.
Supply, fixing, Installation and testing of storage type water heater (Geyser) 25 Ltrs capacity, BEE 4 star rated with copper inner tank and polycarbonate outer body including pressure valve & electric supply connection complete including grouting with nuts & bolts of 15mm dia 100 mm long for hanging the geysers, including PVC connection 15mm dia, 450mm long heavy duty suitable for hot & cold water connections complete including plastering and finishing of disturbed wall surface as per existing finish complete all as specified and as directed. [Make: Venus Model: Venus Splash Copper 25 cu 25 Litre or equivalent of Bajaj / Crompton / AO Smith / Racold having similar specifications and type of protection and with copper tank].
S&F 15 mm dia Bib Cock, cast copper alloy, screwed down high pressure, with crutch or butterfly handle screwed both ends for unions/ sockets complete all as specified and as directed.
S&F single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB 20Amps 240 Volts complete all as directed.
M&L for sub main wiring concealed complete with two runs of single core 2.5 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. including provision of earth continuity wire with same cable as for wiring but in green colour all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F GI tubes 15mm bore dia medium grade galvanized, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
M&L for Chemical Earthing with copper earth plate electrode 900 x 600 x 5 mm thick buried directly in ground, earth pit not less than 5.10 metres below normal ground level and complete size of pit shall be 1.60 m x 1.60 m x 5.10 metres, with top edge of the plate not less than 3.75 metres below normal ground level, earth plate surrounded from all sides by 20 cm thick salt and charcoal dust and Magnesium sulphate filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 50 x 6 mm (up to 7.5 Metres) by means of brazing / coppers nut-bolts, earth strip protected with 65mm bore light grade GI pipe from electrode and up to the earth test point, 15 mm bore light grade GI watering pipe, GI funnel, wire mesh, earth plate surrounded from all sides by 20 cm thick salt (40 Kg), charcoal dust (40 Kg) and Magnesium sulphate (50 Kg) filling in each alternate layers up to 1.80 m height including excavation, removal surplus soil to a distance not exc. 50 m, PCC pit in PCC (1:3:6) type C-1, using 20 mm graded stone aggregate, RCC cover 40 mm thick in RCC (1:2:4) type B-1, using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel deformed bars @ 75 mm centre to centre both ways complete all as specified and directed. NOTE:- Additional Chemical compound if required on account to achieve earth resistance less than 1.00 ohm shall deemed to be included in the unit rate of this item. On testing after completion of job, if desired earth resistance (i.e. less than one ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
M&L for earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to copper earth strip of size 20 X 3 mm by means of nut-bolts, check nuts and washers of copper all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust and common salt all around the earth plate in alternate layers minimum 150 mm (compacted thickness) in all directions with and including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover of size 450 mm X 450 mm in cement concrete 1:2:4, type B-1, duly reinforced with 8 mm dia mild steel TMT bars @ 100 mm both ways center to center with suitable lifting handle made of 10 mm dia mild steel round bar to lift the cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. NOTE: - ON TESTING AFTER COMPLETION OF JOB, IF DESIRED EARTH RESISTANCE (i.e. LESS THAN ONE OHM) IS NOT OBTAINED, THE EARTHING SHALL BE REDONE BY THE CONTRACTOR WITHOUT ANY EXTRA COST TO GOVT.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex head screws for holding the bronze plate including fastening/ bolting the roof down conductor and earth electrode over the bronze plate with copper bolts & nuts of suitable size, providing 10mm thick fibre sheet of size 15x15cm below the test point to avoid direct contact with wall including enclosing the test point with 1.6mm thick MS sheet front openable box duly painted complete all as directed by Engineer -in-Charge.
Supply and fixing of 20 X 3 mm size copper strip as in earth continuity conductor or main earthing lead buried in ground, fixed to wall, any other indicated situation for loop earthing and the like up to test point on necessary insulators and fastening screws, rawl plugs with and including taking out unserviceable one complete all as specified and directed.
S&F Flame proof - weather proof MCB socket & plug combined 16 A, 500 V (3P+Earth) complete all as specified and as directed. Make:- Sudhir/ Baliga/ Shyam/ Bajaj.
M&L for Point wiring complete as specified with 1100 volt grade 2.5sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including rigid non-metallic PVC conduit of suitable size not less than 20mm dia, with all fittings, concealed in wall/ roof / floor including pressed steel concealed terminal boxes of required size with top cover of 3 mm thick of plastic laminated sheet of required colour suitable for housing switches/ sockets/ regulators etc. duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified for one 3 pin 16 Amps socket out let on independent board. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F switch piano, flush type, SP, one way, 15/ 16 Amps, 250 V, ISI marked.
S&F switch socket outlet combination 2 in 1, 3 pin 5 Amps and 15 Amp, flush type, 250 V, ISI marked.
S&F sheet steel powder coated distribution board SPN 4 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs all as specified and as directed.
S&F MCB SPN, 240 volts, 40 to 63 Amps, C curve 10 KA all as specified and as directed.
S&F MCB SP, 40 to 63 Amps, 230 V, C curve, 10 KA all as specified and as directed.
M&L for point wiring complete with PVC insulated unsheathed 1100 V grade cable conforming to IS-694, 1.5sq.mm (nominal area) multi-stranded copper conductor drawn through and including non metallic rigid PVC conduit and conduit accessories, surface type fixed on walls/ floors/ ceilings/ roofs etc., with pressed steel/ welded MS terminal boxes made out of 16G MS sheet with hold fasts covered with 3mm thick laminated sheet for mounting of switches, socket outlets, regulators etc., including provisioning of PVC insulated 1.5sq.mm solid copper conductor for earth continuity and connected to common earth dolly for one light or fan point controlled by one switch/ one 3 pin socket outlet 5/6 Amps on independent board.
S&F Wall/ surface mounted type LED light fitting batten type complete with LED lamp 1x 20/22 watt (4 ft) with extruded aluminium heat sink for efficient heat dissipation and integrated electronic driver complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable. [Make: Philips Cat No: BN021C LED20S PSU CW GR S2 or equivalent in Wipro/ CG]
S&F switch piano, flush type 5/6 Amps, one way, 230V AC
S&F switch socket outlet combination 3 pin 5 Amp, flush type, 250 V, ISI marked.
M&L for sub main wiring concealed complete with two runs of single core 4 sq.mm (nominal area) 1100 volt grade single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including 25mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls/ roofs/ floors etc. including provision of earth continuity wire with same cable as for wiring but in green colour all as specified. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F sheet steel powder coated distribution board SPN 8 ways, 240 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs all as specified and as directed.
S&F MCB SP, 6 to 32 Amps, 230 V, C curve, 10 KA all as specified and as directed.
Supply & Install Perforated GI Tray 1.50mm thick with supporting hangers, ties complete with all standard accessories of size 580mm wide x 50mm height including all connected works and grouting works complete all as specified and as directed.
S&F Electric Energy Meters of digital type, ISI marked, AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 5 - 30 A, tamper proof complete including replacement of old u/s burnt one all as specified and as directed. [Make: Secure/ L&T] Note: Unserviceable Energy Meter shall be deposited in MES Store yard.
S&F Electric Energy Meters of digital type, ISI marked, AC three phase static energy meter of accuracy class 1.0, 3 x 240 V, 50 Hz with Backlit LCD display of rating 10 - 60 A, tamper proof complete including replacement of old u/s burnt one all as specified and as directed. [Make: Secure/ L&T] Note: Unserviceable Electric Meter shall be deposited in MES Store yard.
M&L for Point wiring complete as specified with 1100 volt grade 4sq.mm. (nominal area) single core PVC insulated unsheathed cable with multi-stranded copper conductor of FRLS grade (IS:694) drawn through and including rigid non-metallic PVC conduit of suitable size not less than 20mm dia, with all fittings, concealed in wall/ roof / floor including pressed steel concealed terminal boxes of required size with top cover of 3 mm thick of plastic laminated sheet of required colour suitable for housing switches/ sockets/ regulators etc. duly earthed with same cable as for wiring above but green in colour as continuous earthing wire complete all as specified for one 3 pin 16 Amps socket out let on independent board. [Note:- M&L for cutting chases for concealed conduit wiring on any surfaces and making good disturbed surfaces to match with the existing surfaces in cement mortar 1:3 and finishing with existing finishes shall be deemed to be included in the quoted rate.]
S&F sheet steel powder coated distribution board TPN 6 ways, 415 volts, with 200 Amps rated bus bar, neutral link, earth bar, IP 43 protection and double door, IK-09 with metal door suitable for mounting MCBs all as specified and as directed.
S&F MCB TPN, 415 volts, 40 to 63 Amps, C curve 10 KA all as specified and as directed.
S&F 1100 volts grade heavy duty four single core 10 Sq.mm size (Nominal Area) PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including medium grade rigid PVC conduit ISI marked not less than 40mm dia with necessary fittings, fixed on surface along with a continuous one run of 10 Sq.mm size (Nominal size) stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - FOUR SINGLE CORE CABLES ALONG WITH ONE RUN OF EARTH WIRE AND MS CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S&F Flame proof - weather proof MCB socket & plug combined 25 A, 500 V (2P+Earth) complete all as specified and as directed including taking down existing unserviceable socket. Make:- Sudhir/ Baliga/ Shyam/ Bajaj.
S&F 1100 volts grade heavy duty four single core 4 Sq.mm size (Nominal Area) PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including mild steel ERW conduit ISI marked not less than 25mm dia with necessary fittings, fixed on surface along with a continuous two runs of 4 Sq.mm size (Nominal size) stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - FOUR SINGLE CORE CABLES ALONG WITH TWO RUNS OF EARTH WIRE AND MS CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S&F Wall Fan 400mm sweep, 1350 RPM, single phase, 230 Volts AC, 50 Hz, single phase metallic body (Heavy duty) complete with step regulator, oscillating mechanism, necessary mounting arrangement and making electric connection using three core flexible twisted copper conductor of size 23/0.0076 complete all as specified and directed. [Make: Havells/ Orient/ Bajaj/ Usha]
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded Copper conductor of size 3 core, 1.5 Sq.mm complete fixed to wall with suitable clamps, bolts & nuts all as specified and as directed.
Supply and fix die cast aluminium LED Flood light 50W IP 65 with high power LEDs, integral flood light with driver inside a PDC housing including all fittings, clamps, angle frame etc for fixing on wall/ pole etc complete all as specified and as directed. [Make: Cat Part No. JETA QUANTOPLUSFLP50WLED757SYMLENS of make Havells or equivalent in Philips/ C&S/ CG].
K.S.Traders
LAMBA BUILDERS
SONI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .