Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹16.5 LAccepted-AOC 121 BEHARIPUR MEMARAN BAREILLY UP PIN 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹16.5 L | L-1 | Accepted-AOC Over all rates are reasonable and lowest. |
| 2 | L-2₹19.6 L+₹3.1 L (18.5%)Rejected-Finance | ₹19.6 L+₹3.1 L (18.5%) | L-2 | Rejected-Finance Over all rates are higher than L-1. |
| 3 | L-3₹19.8 L+₹3.2 L (19.5%)Rejected-Finance | ₹19.8 L+₹3.2 L (19.5%) | L-3 | Rejected-Finance Over all rates are higher than L-1. |
| 4 | L-4₹21.1 L+₹4.6 L (27.7%)Rejected-Finance | ₹21.1 L+₹4.6 L (27.7%) | L-4 | Rejected-Finance Over all rates are higher than L-1. |
| 5 | L-5₹21.3 L+₹4.8 L (28.7%)Rejected-Finance | ₹21.3 L+₹4.8 L (28.7%) | L-5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
Refer Docs
EMD Value
₹47,200
Closing Date
15 Oct 2020, 6:00 pmClosed
Garrison Engineer, Air Force, Bareilly
Garrison Engineer, Air Force, Bareilly, 243002
PROVISION OF ECO GARBAGE PITS, PROVISION OF WEATHER PROOF EXTERIOR EMULSION PAINT IN CERTAIN BUILDINGS AND PROVISION OF CERTAIN B/R REVENUE AND MINOR WORKS AT AF STATION BHOWALI AND LKT UNDER AGE(AF) BHOWALI.
2020_MES_378697_1
8555 / E8
Open Tender
Civil Works
Item Rate
180 days
Bhowali
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Air Force
₹47,200
Yes
14 Dec 2020
18 Sept 2020
17 Oct 2020
18 Sept 2020
15 Oct 2020
3 Oct 2020
18 Sept 2020 - 3 Oct 2020
Amount
Excavation over areas not exc. 1.50 m deep and getting out in any type of soil complete all as specified and directed.
M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed.
Removing surplus demolished building material to distance exc. 1.50 Kilometre but not exc. 5.00 Kilometre and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:4 finished even and fair complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
S & F of rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. confirming to Fe-410-W (Grade E-250) Quality 'B', drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting and also fastening complete all as specified and directed.
S & F of 0.80 mm thick mild steel plain black sheet in hearth, covering of door shutters, covering to door chowkhats (frames), chullah hoods, water tank, water troughs and funnels etc., cut to size, edges beaded if directed, holes punched including round headed screws, clout nails or rivets and fixed to wood or steel members etc. with plain 40 mm lap joints with welded / rebated seams including bending, turning up, mitred angles, stopped ends, outlets etc. as required complete all as specified and directed.
S & F of flat iron bands, straps, supports, clamps, hold fasts, wall ties, hooks for hanging fans and other similar small steel article confirming to Fe-290 Grade E-165 with and including necessary nut-bolts, washers, screws etc. as required complete all as specified and directed.
M & L for complete removal of old decoration by scraping off the same from wall, chajja or facia surfaces of any description over 10 cm width or girth and applying two coats of exterior grade acrylic emulsion paint over one coat of exterior gade wall primer and a thin layer of wall care putty (Minimum 1 mm thick) complete all as specified and directed.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and fair complete all as specified and directed.
M & L for rendering 10 mm thick cement plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces as on chajja, facia and the like, finished even and fair without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall, chajja or facia of any description over 10 cm width or girth and applying two coats of exterior grade acrylic emulsion paint over one coat of exterior gade wall primer and a thin layer of wall care putty (Minimum 1 mm thick) complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
Excavation in post holes (or similar holes) each not exc. 0.50 Cum, getting out in hard / dense soil, returning, filling and removing surplus soil to a distance not exc. 50 m and making good surface complete all as specified and directed.
M & L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS-1161(1979) grade St-240 complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L preparation of surface of any description wood, steel, iron, concrete, brick, stone, etc. exceeding 10 cm in width or girth and applying one coat of black bituminous paint complete all as specified and directed.
S & F of rolled mild steel plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to Fe-410-W (Grade E-250) quality-A complete all as specified and directed.
S & F of mild steel screw bolt (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc. 5 cm but not exc. 10 cm and diameter of the neck of bolt 5 to 10 cm complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
M & L for 15 mm thick screed bed or bedding layer in cement mortar 1:6 for laying floor finishes finished even and rough complete all as specified and directed.
M & L for Non skid ceramic joint free coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
M & L for Non skid ceramic joint free coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, in verical surface such as dado / skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including 10 mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
M & L for complete removal of old decoration by scraping off the same from wall or ceiling surfaces of any description over 10 cm width or girth and applying two coats of distemper oil emulsion over one coat of primer and a thin layer of wall care putty (Minimum 1 mm thick) complete all as specified and directed.
S & F of 10 mm thick PVC insulation panels with EPS stuck to 1 mm plain PVC sheet suitably placed in false ceiling grid made of Aluminium, GI, or MS, as per specifications and drawing given on MES schedule Part – II (2010) complete all as specified and directed.
S & F of Hangers made of 6 mm dia GI wire (up to 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made of GI flat 40 X 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and directed.
S & F of GI frame work for seamless ceiling grid of size 605 X 605 mm comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre, intermediate channel 0.90 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc. 1.20 m length) of 0.55 mm thickness having curled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed.
S & F of aluminium anodised powder coated of approved colour, sliding type three track window or ventilator with sliding shutter and frame with and including aluminium grill, 5 mm thick tinted glass and mosquito proofing net as detailed below complete all as specified and directed: - (i) Frame made of section size 92 X 31.75 X 1.30 mm suitable for bottom, top and sides of window frame. (ii) Shutter for top, bottom and side rails 40 X 18 X 1.29 mm. (iii) Glass 5 mm thick one side reflective glass and other side visible fixed with rubber gasket and aluminium clips of suitable size, 4 Nos. aluminium hold fasts with each window and necessary handles, tower bolt etc. as directed. (iv) Aluminium grill made of 5 mm dia powder coated aluminium section as per design No. DG-102 of make DEDO grill or design No. A-103 duly fixed with aluminium section 50 X 20 X 1.5 mm size. (v) Stainless steel wire cloth having 0.36 mm nominal dia of wire and average width of aperture 1.40 mm duly fixed with tined tacks or galvanised wire staples.
S & F of aluminum section powder coated of approved colour as in door frame and shutter partially glazed with 5.5 mm thick one side refelctive glass and partially panelled, panel made of 5 mm thick PVC composite board duly fixed with aluminium clips comprising of the following complete as specified and directed:- (i) Frame made of section size 100 x 40 x 2 mm thick. (ii) Styles of shutter made of section size 85 x 44.45 x 3 mm thick. (iii) Top rail made of section size 95.25 x 44.45 x 1.7 mm thick. (iv) Middle rail made of section size 83.50 x 44.75 x 1.7 mm thick. (v) Bottom rail made of section size 114.30 x 44.15 x 1.7 thick. (vi) Glazing aluminium clips made of 0.70 mm thick section. (vii) 2 Nos. Handle Powder coated Aluminium 200 mm long as approved. (viii) Tower bolt having dia of bolt 9.90 mm dia and 200 mm long. (ix) Mortice lock 100 mm size, 7 Livers make Godrej. (x) Hold fast aluminium 100 mm long. (xi) One No. Floor door spring with each shutter. (xii) 1 No. 300 mm long sliding door bolt of Aluminium duly Powder coated.
Demolition of reinforced cement concrete as in shelves, roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
S & F of exterior type metal false ceiling wih unique tongue and groove arrangement for rigid system comprising of the following specifications complete all as specified and directed: - (i) PANEL: - Metal ceiling panel having 150F panel of size 150 mm wide and 12.50 mm deep roll formed from 0.50 mm thick aluminium powder coated sheet having powder coating 50 micron polyester powder painting on exposed side and 5 micron of rear side. (ii) CARRIER (FRAME WORK): - 34.5 mm wide X 48 mm deep carrier made of 0.6 mm thick steel sheet having arrangement of holding 150F panel. The carrier to be spaced at 1.70 metres centre to centre without insulation and 1.50 metres centre to centre with insulation. (iii) SUSPENSION: - 4 mm dia galvanised steel wire rod hanger and steel suspension clip to be fixed to roof by J hooks and nylon cleat and shall be spaced at 1.50 metres centre to centre without insulation and 1.30 metres centre to centre with insulation.
S & F of 3 mm thick Aluminium composite panel coloured (as approved by GE or Engineer-in-Charge) including aluminium frame work made of aluminium hollow section of size 35 mm X 25 mm having wall thickness 0.90 mm, fixed at 50 cm centre to centre on verical and horizontal for fixing of panel with double tap and joints filled with silicon on wall, column, facia and the like complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and fair complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3 (Nominal Mix) type A-1, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3 (Nominal Mix) type A-1, using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in damp proof course to horizontal or vertical surfaces including necessary form work and mixing of water proofing compound as per manufacturer’s instructions complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND WILL BE MEASURED AND PAID SEPARATELY.
M & L for applying evenly a coat of blown type bitumen @ 1.50 Kg per Sqm including cleaning of surface and binding with clean dry sand @ 0.05 cum per Sqm complete all as specified & directed.
M & L for preparation of newly plastered previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer and a thin layer of wall care putty (Minimum 1 mm thick) complete all as specified and directed.
Supply and fixing of mild steel galvanised chain link fencing, any size or type including provision of straining bolts, binding wire etc. and fixing to any type of standards, rails etc. complete all as specified and directed.
S & F of mild steel work in hand rail, half round or other stock section or core for fixing of wooden hand rails, bluster, running bars, nosing of steps, wind ties, post and struts for fencing, flat iron fillets and the like including necessary cutting, drilling holes, notching etc. as required conforming to Fe-290 Grade E-165 complete all as specified and directed.
S & F of mild steel framed work such as framed door hung as gates including pintle hinges, stops, hand-made sliding bolts, etc. with ends of bars shouldered and / or riveted, or forged into spikes and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed.
M & L for providing plain cement concrete type C-1, 1:3:6, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on other than fair faces of brick work or stone masonary surfaces finished even and fair without using extra cement complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
Supply only integral water proofing compound (Powder) complete all as specified.
rehman construction company
NOORI ENTERPRISSES
MESSERS KHARAK SINGH BISHT
BHUWAN SINGH ADHIKARI
M/s J P Traders
Ramsons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .