Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC | ₹9.4 L | L1 | Accepted-AOC CFA Approved |
| 2 | L2₹9.5 L+₹5,743 (0.61%)Rejected-Finance | ₹9.5 L+₹5,743 (0.61%) | L2 | Rejected-Finance CFA Not Approved |
| 3 | Rejected-Technical | - | - | Rejected-Technical CFA Not Approved |
| 4 | Rejected-Technical | - | - | Rejected-Technical CFA Not Approved |
| 5 | Rejected-Technical | - | - | Rejected-Technical CFA Not Approved |
| Sl No | Description | Qty | Unit | PRANAB SAHA L1 | SAYAN SAHA L2 |
|---|---|---|---|---|---|
| 1.01 | M/L for carrying out Geo physical survey for ground water exploration by electrical resistively technique at different location spread at suitable intervals to find out delineation of lithological features of area thickness of layers and most favorable site for ground water strata based on geological parameters and disposition of Sub surface formation aquifer up to depth of 200 mtrs and submitted a detailed report in this regards. | 1 | Job | 80,000 ₹80,000 Lowest | 82,000 ₹82,000 |
| 1.02 | Boring/ drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level, All types of soil 300 mm dia. | 100 | Rm | 1,020 ₹1,02,000 Lowest | 1,023 ₹1,02,300 |
| 1.03 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge : 200 mm nominal size dia having minimum wall thickness 5.40 mm. | 70 | Rm | 3,540 ₹2,47,800 Lowest | 3,545 ₹2,48,150 |
| 1.04 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge : 200 mm nominal size dia. | 30 | Rm | 3,750 ₹1,12,500 Lowest | 3,780 ₹1,13,400 |
| 1.05 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | 7.07 | Cum | 2,300 ₹16,261 | 2,200 ₹15,554 Lowest |
| 1.06 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. | 3 | Cum | 2,500 ₹7,500 | 2,450 ₹7,350 Lowest |
| 1.07 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. | 3 | Cum | 2,700 ₹8,100 Lowest | 2,800 ₹8,400 |
| 1.08 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. | 4 | Hour | 1,700 ₹6,800 | 1,650 ₹6,600 Lowest |
| 1.09 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia. | 1 | Each | 700 ₹700 Lowest | 800 ₹800 |
| 1.10 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete : 200 mm clamp. | 2 | Each | 3,250 ₹6,500 Lowest | 3,280 ₹6,560 |
Tender Value
₹9.7 L
EMD Value
₹20,000
Closing Date
4 Oct 2025, 10:00 amClosed
DIG HQ 21 Sect AR
DIG HQ 21 Sector AR Agartala
Provn of Borewell incl allied services for supplying water to KLP at Teliamura of 28 AR
2025_ARMHA_878541_1
Engr/21 Sect/28AR/EW/2025-26/01
Open Tender
Civil Works
Works
365 days
Agartala
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
DIG HQ 21 SECT AR
₹20,000
Yes
3 Mar 2026
22 Sept 2025
6 Oct 2025
23 Sept 2025
4 Oct 2025
23 Sept 2025
23 Sept 2025 - 4 Oct 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .