Manager (Electrical Projects)
KEL MAMALA KOCHI
ESTABLISHMENT OF VALUE ADDED FISH PROCESSING CENTRE IN MULAKUZHA, CHENGANNUR
2025_KEL_776187_1
KEL/KMEP/EPROC/006/2025-26
Open Tender
Electrical Works
Item Rate
KEL MAMALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
₹50,000
Yes
23 Jul 2025
11 Jul 2025
22 Jul 2025
11 Jul 2025
21 Jul 2025
11 Jul 2025
11 Jul 2025 - 21 Jul 2025
Amount
WIRING
OD84126/2024-2025 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit conduit, with Modular type Water protecter switch, plate, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
1.10.2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
OD84134/2024-2025 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium duty PVC conduit, 2 way modular water proof switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
1.14.8: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire
1.21.1 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.27.2 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
OD84169/2024-2025 Supplying and fixing following Water Proof Modular base & cover plate on existing modular metal boxes etc. as required. 3 module
OD84174/2024-2025 Supplying and fixing following Water Proof Modular base & cover plate on existing modular metal boxes etc. as required. 6 module
OD84207/2024-2025 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A Water proof modular switch, connections etc. as required.
OD84230/2024-2025 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A Water proof modular socket outlet and 15/16 A modular switch, connections etc. as required.
OD84237/2024-2025 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, VTPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required Water Proof Hensal or equalent brand 6WAY VDB
OD84253/2024-2025 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)Water Proof Hensal or equalent brand 12WAY SPNDB
90.11.1.16 Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required 8 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.3.3 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door
OD84262/2024-2025 Supply, installation, testing and commissioning of Floor Mounting Cubical Type Switch Board Panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having sufficient front surface area fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame works, covers and gland plates, cleaning and finishing complete with 7 tank process for powder coating in approved shade, having 160 Amps capacity TPN Aluminium alloy busbars of high conductivity, DMC / SMC / FRP bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 3 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminium bus bars and control wiring with 1.5 Sq.mm FRLS PVC insulated single core copper conductor cables, cable alleys etc. complete as required. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Engineer-in-charge and the Electrical Inspectorate. BUSBAR 1 Runs of 25 mm x 10 mm Aluminium for each Phase 1 Runs of 25 mm x 6 mm Aluminium for Neutral EB INCOMER SIDE 1 Set - RYB Indication Lamps with Control MCBs 1 Nos - 160A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% Setting Provision with ROM and Spreader 3 Nos - 160/5A 10VA CL:1 Resin Cast CT 1 Nos - Digital Multifunction Meter measuring V, A, F, KWH, KVA, PF with Control MCBs DG INCOMER SIDE 1 Set - RYB Indication Lamps with Control MCBs 1 Nos - 160A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% Setting Provision with ROM and Spreader 3 Nos - 160/5A 10VA CL:1 Resin Cast CT 1 Nos - Digital Multifunction Meter measuring V, A, F, KWH, KVA, PF with Control MCBs AUTOMATIC TRANSFER SWITCH 1 Nos - 160A 4P Automatic Transfer Switch with Interlock OUTGOINGS 3 Nos - 100A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% Setting Provision with ROM and Spreader 4 Nos - 63A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% Setting Provision with ROM and Spreader
OD84289/2024-2025 Fabrication, supply & installation of dust and vermin proof, wall mounting, meter box of required size suitable for fixing KSEB meter,fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit including 200A MCCB WITH ELR CBCT - 1 no, 160A Cut out Fuse - 3 nos, 200/5A, Class 0.5s, 15VA Cast resin CTs - 4 Nos, neutral link etc complete as required at site
5.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.12.1.46 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). 4 core 95 sq mm
90.12.7.46 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 95 sq mm
90.12.7.41 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 3.15 mm copper conductor ( 10 SWG)
9.1.24 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 1/2X 95 sq. mm (45mm)
9.1.32 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
9.1.33 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm)
OD84336/2024-2025 Supply, Installation, Testing and commissioning of Three phase industrial type socket IP44 WATER PROOF make HENSSAL or equivalent with its connected accessories and complete the work as required.
OD84337/2024-2025 Supply, Installation, Testing and commissioning of Single phase industrial type socket IP44 WATER PROOF make HENSSAL or equivalent with its connected accessories and complete the work as required.
2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.10.4 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
5.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
OD70136/2025-2026 Supply and fixing of INDUSTRIAL weather proof 36W LED TUBE SET having surface and wall mounted moisture resistant IP65 LED battens with vandal-resistant polycarbonate housing, diffusewr and integrated electronic driver and complete the connections as required. (Make and model: Havells 36w ENDURALINE ARBS36WLED865SPCWHG1)
OD70187/2025-2026 Supply and installation of 350mm dia heavy duty metal Exhaust fan with all the accessories and complete the work as required.
OD76473/2025-2026 Supply, installation, testing and commissioning of 20W LED tube light and complete the connection as required.
EXCLUSIVE OF GST
YOOSAF K A (BID ID -2255017)
A ONE AGENCIES (BID ID -2256289)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .