Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAccepted-Finance | ₹4.6 Cr | L1 | Accepted-Finance ACCEPTED |
| 2 | L2₹4.6 Cr+₹6.1 L (1.32%)Rejected-Finance | ₹4.6 Cr+₹6.1 L (1.32%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹4.8 Cr+₹21.6 L (4.71%)Rejected-Finance 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | ₹4.8 Cr+₹21.6 L (4.71%) | L3 | Rejected-Finance REJECTED |
| 4 | L4₹4.9 Cr+₹31.0 L (6.75%)Rejected-Finance BANSAL COTTAGE BADRI NAGAR TEH PAONTA SAHIB SIRMAUR | SIRMAUR | HIMACHAL PRADESH | 173025 | ₹4.9 Cr+₹31.0 L (6.75%) | L4 | Rejected-Finance REJECTED |
| 5 | L5₹5.1 Cr+₹47.7 L (10.4%)Rejected-Finance | ₹5.1 Cr+₹47.7 L (10.4%) | L5 | Rejected-Finance REJECTED |
| Sl No | Description | Qty | Unit | HILL CONSTRUCTION AND ENGINEERING CO. SOLAN L1 | KRP Engineering Pvt. Ltd. L3 | HYDRAULIC ENGINEERING COMPANY L2 | H. C. Bansal Engg. & Contt. L4 | Universal Electric Engineers L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Centrifugal Pumping Machinery for Phase-1 | ||||||||
| 1.01 | Supply, erection, testing & commissioning of horizontal spindle, horzontal split casing radial slit single /multistage centrifugal pumps of KSB/ Mather & Platt/ Jyoti/ Kiroskar /Beaconweir/ BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handel clear water having characteristics as mentioned below in ltem no 1(A), with impelleres,casing ring priming funnels & shaft sleeves of bronze , shaft of steel of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ Mild steel to BHEL/ Kirlokar/ NGEF/Crompton/Siemen /jyoti/GEC make slip ring /squirrel cage screen protected drip proof 3 phase induction electric motor of minimum efficiency level of IE 2.0 or heigher suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage at the site sites as per direction of Engineer-in - charge. :- | 2 | Per SET | 10,60,000 ₹21,20,000 | 13,00,000 ₹26,00,000 | 9,75,000 ₹19,50,000 Lowest | 18,40,000 ₹36,80,000 | 11,50,000 ₹23,00,000 |
| 1.02Total Head - 420.2 mtrs | ||||||||
| 1.03Capacity of pump - 13.79 LPS | ||||||||
| 1.04Dia of R/Main - 150 mm | ||||||||
| 1.05Length of R/main - 1527 mtrs | ||||||||
| 1.062 X 130 HP =260 HP | ||||||||
| 2.00 | Supply & erection of suitable direct on line/oil immersed star delta /ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . | 2 | each | 1,70,000 ₹3,40,000 | 1,20,000 ₹2,40,000 Lowest | 1,45,000 ₹2,90,000 | - | 2,50,000 ₹5,00,000 |
| 3.00 | Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge. tc. make:-Reputed ISI marked make or approved by the technical committee of the department 1 No. | 1 | each | 1,80,000 ₹1,80,000 | 5,000 ₹5,000 Lowest | 1,60,000 ₹1,60,000 | - | - |
| 4.00 | Ammeter AC supply, 100mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selectro switches conforming to BIS 1248-1983 latest with upto date ammendments. | 2 | each | - | 5,000 ₹10,000 Lowest | - | - | - |
Tender Value
₹5.4 Cr
EMD Value
₹6.2 L
Closing Date
3 Aug 2026, 9:00 amClosed
Executive Engineer Jal Shakti Division Shillai
Executive Engineer Jal Shakti Division Shillai
C O RCC intake 105000 litres capacity , Sump well 140000 litres capacity, supplying and erection of pumping machinery with allied accessories, C/O pump house, providing, laying, jointing andtesting in tranches of glvenized steel welded pipe and layi
2026_HPIPH_139577_1
SHL-SMR03-780-JSV DIV-SHILLAI 2537-87 Dt 21.7.26
Open Tender
Pumps/Motors
Item Rate
365 days
Shillai
Please refer Tender documents.
15 documents required · 15 mandatory
₹10,000
Executive Engineer Jal Shakti Division Shillai
₹6.2 L
2 Sept 2026
22 Jul 2026
3 Aug 2026
22 Jul 2026
3 Aug 2026
22 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Centrifugal Pumping Machinery for Phase-1 | |||||
| 1.01 | Supply, erection, testing & commissioning of horizontal spindle, horzontal split casing radial slit single /multistage centrifugal pumps of KSB/ Mather & Platt/ Jyoti/ Kiroskar /Beaconweir/ BS & BE conforming to BIS 1520-1980 with upto date ammendments read with BIS 9137-1978 or latest edition to handel clear water having characteristics as mentioned below in ltem no 1(A), with impelleres,casing ring priming funnels & shaft sleeves of bronze , shaft of steel of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate of cast steel/ Mild steel to BHEL/ Kirlokar/ NGEF/Crompton/Siemen /jyoti/GEC make slip ring /squirrel cage screen protected drip proof 3 phase induction electric motor of minimum efficiency level of IE 2.0 or heigher suitable for operation on the data given below i/c the cost of all the accessories in all leads and lifts & carriage at the site sites as per direction of Engineer-in - charge. :- | 2 | Per SET | - | - |
| 1.02 | Total Head - 420.2 mtrs | - | - | - | - |
| 1.03 | Capacity of pump - 13.79 LPS | - | - | - | - |
| 1.04 | Dia of R/Main - 150 mm | - | - | - | - |
| 1.05 | Length of R/main - 1527 mtrs | - | - | - | - |
| 1.06 | 2 X 130 HP =260 HP | - | - | - | - |
| 2 | Supply & erection of suitable direct on line/oil immersed star delta /ATS/stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/Larson & Tubro conforming to BIS-8544-1979 latest with up to date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot,time lag,under voltage release with initial oil filling . | 2 | each | - | - |
| 3 | Providing M.S. sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle Iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessories with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-Charge. tc. make:-Reputed ISI marked make or approved by the technical committee of the department 1 No. | 1 | each | - | - |
| 4 | Ammeter AC supply, 100mm circular dial Auto electric/AE/IMP/Havells make of suitable range for above motor with selectro switches conforming to BIS 1248-1983 latest with upto date ammendments. | 2 | each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.75 MB
Form_6_LISGuddiSharlipmm.pdf
Tender Documents • 0.31 MB
Terms_con_lisSharli.pdf
Tender Documents • 0.13 MB
Specification_LIS_Sharli.pdf
Tender Documents • 0.05 MB
BOQ_207024.xls
BOQ • 0.35 MB
Form_8.pdf
Tender Documents • 0.64 MB
Corrigendum_2_LIS_SHARLI.pdf
PDF • 1.11 MB
Corrigendum_LISSHARLI.pdf
PDF • 1.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .