Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹24.0 L+₹5.6 L (30.5%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹24.5 L+₹6.2 L (33.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹24.6 L+₹6.3 L (34.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹29.8 L+₹11.4 L (62.2%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹97,120
Closing Date
13 Mar 2021, 6:00 pmClosed
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT - 133001
MANNING AND OPERATION OF WATER SUPPLY INSTALLATION IN SECTOR A UNDER GE UTILITY AMBALA CANTT
2021_MES_419640_1
GE(U)/AMB-56/2020-21
Open Tender
Civil Works
Item Rate
330 days
AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹97,120
Yes
19 Apr 2021
22 Feb 2021
15 Mar 2021
22 Feb 2021
13 Mar 2021
8 Mar 2021
22 Feb 2021 - 6 Mar 2021
Amount
SCHEDULE 'A' (SECTION-I) Manning and Operation of complete water supply System By Technically qualified Teams for round the clock (01 FGM per shift of 8 hrs) including Sunday and Holidays .The installation comprises of 50 HP submersible pump set and DG set 50 KVA and electric control panel etc. at TW-05 including operating of valves of OHT No 05 Sec A Area complete all as specified and directed by Eng-in-Charge. The scope of work primarily comprises of :-
(a) Running of pump set and to fill connected over head tanks complete round the clock all as directed by Engr -in-charge otherwise a panelty of Rs 500/- per day will be imposed for not running pump sets without any fault or over running the pump set resulting in overflow of OHT and wastage of water.
(b) Operation of chloronome plants.Contractor will be responsible for proper chlorination of water i.e 2 ppm at installation and maintain the register of daily results otherwise a panelty of Rs 250/- per day will be imposed for non operation of chloronome plants and Rs 350/- per day penalty will be imposed for not maintaining the results of 2.00 ppm at installation.
(c ) Minor repair Such as gland packing ,Nut Bolts if reqd at site otherwise a panelty of Rs 100/- per day will be imposed for not providing gland packing/ leakage of valves within the installation.
(d) Rectifying any electric complaints within the installation which is essential to run installation will be carried out by the contractor otherwise a panelty of Rs 500/- per day will be imposed for not rectifying the electric complaints within the installation.
(e) The contractor will submit Log Sheet of pump set, generator and chloronome plant per month to Engr-in -Charge. In case of non submission of log sheets a panelty of Rs 250/- per day will be imposed.
(f) Area of installation will be Kept neat & clean by removing growth of vegetation ,grass and bushes at of installation, at the path of installation and upto whole installation .Suitable endorsement for this will be made daily in a register kept at installation.Panel recovery at the rate of Rs 250/- per day will be recovered in case of installation and surrounding area found unsatisfactory.
(g) Proper accounting and security of Govt Assets. Any loss will be made good by the contractor. All the pumpsets installed in pump house will be sole responsibility of the contractor.Any damage or loss of the govt property will be made good by the contractor.
(h) All type of Stationary ,T&P for maintenance & operation will be provided by contractor .
(j) All safety provision contained in IE rules will be followed by the contractor.
Description all as per srl item No 1.00 here In before but in centrifugal pump sets and Generating set at Booster 288 Zonal sump instt booster of Sec A Area complete all as specified and directed by Engr-in-Charge.
Description all as per srl item No 1.00 here In before but in centrifugal pump sets and Generating set at Booster Alfa-2 Panipat line Zonal sump booster of Sector A Area complete all as specified and directed by Engr-in-Charge.
Description all as per srl item No 1.00 here In before but in 40 HP submersible pump set,-01 No centrifugal pump set 50 HP & 20 HP one no each DG set 50 kVA LT panel-01 No at TW No 15 including operationg of valves, OHT 15 & 16 Sector B area complete all as specified and directed by Eng-in-Charge.
Description all as per srl item No 1.00 here In before but in centrifugal pump sets and Generating set at TW No 40 of Sector A Area complete all as specified and directed by Engr-in-Charge.
a) Cleaning of valve pit. Rs.100 will be imposed for not cleaning of valve pit, a register will be maintained for the same.
b) Minor repair such as gland packing, tightening of nut bolts etc if required Rs.100 will be imposed for leaking of valve.
c) Area of installation below and upto 3 mtr surrounding over head tank , its path Rs.250 per overhead per day will be charged .will be kept neat & clean
d) Log sheet to be maint and submitted at the month end for Panelty of Rs.200
e) Proper accounting and security of Govt assests.
f) All type of stationary by contractor.
g) All safety provn to be maint by cont.
h) Manning person can be utilised at any other installation as per directed by Engr in Charge
The rates qouted by the contractor shall be inclusive all taxes like GST,EPF, ESI, LWC as applicable and also include contractor's profit etc. In this connection please refer Note 20 of Sch A/BoQ Notes mentioned in tender documents.
Note for contractor: (a) Providing summer and winter uniform along with proper shoes to the operators.(b) Providing T&P and display board of the firm along with minimum fare wages written on it. (C) Maintaining log sheets, duty roster, attendance register along with photo of the individual operator must be displayed at pump house or at the installation. (d) Rates of all above notes deemed to be included by the contractor in quoted rates. (e) If all above documents are not found during inspection of AGE or GE, the penalty of Rs.100/-per day will be imposed from the first date of the each month.
SCHEDULE 'A' (SECTION-II) Disconnecting all electrical connections from electric motor 25 to 40 HP and decoupling from pump assembly and dismantling from foundation and transporting to local workshop approved by Accepting Officer for opening the motor taking out of burnt winding and thorough cleaning of the slotes, rewinding the complete motor with supper enamaled copper wire of same size and provn of supper quality insulating materials, warnishing and drying and taking back from wksp including laths and other any type of machine work such as rotor work, welding, metalling, machining and grinding for bearing sheet etc and mounting, connecting all electrical connections alongwith reassembling pump set and testing complete all as directed by Engr-in-Charge.
Taking out US Centrifugal pump set of capacity 35/40 HP and deposit to MES Store and supply and fixing new centrifugal pump set including motor as per existing motor and connections, connected items with suitable 3 Phase star delta starter complete set (Motor Horizondal Split casing pump model DSM 100/36 ) including CI connection with CI impeller 40 C8- shaft complete set of capacity 35 to 40 HP including all connected items and foundation allignment all as specified and directed by the Engr in Charge.
Material and labour in repair run lead joints suitable for 80 mm bore CI/DI pipe and fittings including jointing material such as lead, spun yarn etc complete all as specified and directed by Engineer-in-Charge.
Description all as per serial item No 8.00 here-in-before but 100 mm bore pipe -ditto-
Description all as per serial item No 8.00 here-in-before but 150 mm bore pipe -ditto-
Description all as per serial item No 8.00 here-in-before but 200 mm bore pipe -ditto-
Description all as per serial item No 8.00 here-in-before but 300 mm bore pipe -ditto-
Repacking stuffing box of sluice valve spindle including taking apart and reassembling of size upto 300mm bore size all as specified and directed by the Engr-in-Charge.
Taking out sluice valves refacing, regrinding and refixing including replacing spindle and check nut and making serviceable of size 80 to 300mm bore size all as specified and directed by the Engr-in-Charge.
Note :- Amount of credit of Rs. 24200.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
m/s parmod kamar
MAYANK ENTERPRISES
Bal Singh and Sons
MAHESH GAUR AND CO.
G M CONSTRUCTION COMPANY
Raman Electric Trading Co
M/S Sonu Traders
singh traders
M/S VEDHANT ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .