Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 2ND FLOOR COMMERCE CENTRE KULUR KAVOOR ROAD KULUR MANGALORE D K 575 013 | DAKSHINA KANNADA | KARNATAKA | 575013 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹21.8 L
EMD Value
₹51,460
Closing Date
3 Oct 2024, 4:00 pmClosed
Executive Engineer Electrical
Electrical Division, Admin Building, NMPA Panambur Mangaluru
Electrification of two numbers covered Storage Sheds inside Wharf
2024_NMPT_825925_1
1/Trans-Shed/EE(E)II/2024 dtd.12.09.2024
Open Tender
Electrical Works
Works
90 days
NMPA Panambur Mangaluru
Please refer Tender documents.
2 documents required · 2 mandatory
₹560
Yes
FA and CAO NMPA
₹51,460
Yes
26 Nov 2024
13 Sept 2024
4 Oct 2024
13 Sept 2024
3 Oct 2024
13 Sept 2024
Supplying of 4Core x 4 sq.mm LT, UG cable having copper conductor XLPE insulated sheathed, Galvanized, Steel wire armoured cable with PVC outer sheathing 1.1 KV class
Supplying and drawing of 3C x 2.5sq.mm Flexible multi core cable manufactured flexible copper flexible PVC and insulated and sheathed 1100V grade cable from Marshaling box to lighting fixture
Supplying of PVC flexible conduit pipe 20mm dia for covering flexible cables fixing on wall using heavy gauge saddles using NF screws etc. complete
Labour charges for laying of 4core x 4 sq.mm armoured UG cable /on wall/ structure as required with necessary saddles/clamps etc. complete
Supplying and installation/ fixing provision of box for MCB and CBT connectors for 3ph/1ph connections with loop-in and loop-out for terminating 4C x 4 sq.mm branch out 3C x 2.5 sq.mm copper cable enclosed in a 260 x 210 x 116 mm thermo plastic polystyrene enclose it should be shock proof safe rust proof IP65 rust proof, dust proof, water proof having internally embedded Gasket with provision for cable entry through IP65 thermoplastic polyamide glands. Work including supply & fixing of 10A DP MCB and 5Nos. M6 CBT connector and terminating the incoming and outgoing cables by using suitable lugs
Supplying and fixing angle iron frame work fabricated out of MS angle iron of size 40x40x6mm and MS flat of 40x6mm with SS bolt, nuts washer etc. (or fixing as required at site), complete and painted with 2 coats of red oxide and then 2 coats of approved paint suitable for mounting light fitting
Supplying of 150W LED flood light fitting as per technical specification
Fixing of 150W LED flood light fitting over existing angle iron frame using SS bolts, nuts focusing to the working area wiring complete
Supplying of 4pole, 125A, 25KA, MCCB
Supplying of 16A, DP MCB’s
Supplying of 16A single pole MCB’s
Supplying of M6 CBT connectors.
Supplying of 3pole 60A contactors
Supplying of Electromechanical Time Switch 24Hour programmer
Supply, Installation and fixing of thermoplastic modular Panel enclosure of size 600x600x170mm with transparent polycarbonate lid, shock proof, IP65 weather proof, rust proof, dust proof, water proof, corrosion proof having internally embedded, gasket on both lid and flap with Hylum sheet (for fixing the component inside the box) suitable to fix 125A, 25KA, MCCB, MCBs and CBT connectors work including fixing the enclosure in the existing wall and fixing of CBT connectors. Work including supply of suitable rails (for fixing MCBs timer and CBT connectors) glands, fork busbar for MCBs neutral link (Bolt and nut type) and all wire and internal wiring in the enclosure by using suitable materials (such as wire and lugs) and provision for 3.5C x 95sq.mm cable gland for incomer and glands for 4R x 4C x 4sq.mm outgoing cable. The connection between MCCB to contactor and contactor to MCBs should be through 16sq.mm flexible copper wire and other wiring (from MCB to connector) through 6sq.mm copper wire with required lugs from MCB to connector, complete.
Supplying and fixing earth electrode for grounding of light circuits, using 40mm dia., 2.9mm thick, 2.5mtr long GI pipe with GI funnel with mesh and suitable –SBC reducer fixed on top of earth electrode. The funnel should be enclosed in CC chamber of 400x400x100mm with cast iron cover. The earth electrode shall have staggered holes of 12mm dia. And the electrode should be coved 150mm around pipe complete depth with alternate layers of salt and charcoal. The connection from the electrode is to be established through 25 x 3 copper flat using GI bolts and nuts
Supplying and running 25x3mm copper strip for grounding connection using fixing materials as required
Supplying and running 4sq mm PVC insulated multi strand single core copper wire in open system for grounding connection using fixing materials as required.
Supplying of LT UG cable of size 3.5C x 95 Sq mm having Aluminium conductor XLPE insulated, sheathed, galvanized, steel wire/steel tape armoured cable 1.1KV class
Labour charges for laying of 3.5C x 95 Sq.mm UG cable in existing trench
Digging of trench of size 0.6mtr x 0.5mtr of laying of LT cable and refill the trench. In some places paver blocks, concrete & asphalt in cable route, whenever removed, Refixed the paver blocks, re-concrete/ asphalt the road Hard soil.
Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm around the cable
Supplying & laying of RCC semi cut pipe (C-CUT) in existing trench over the cable. Size:150mm dia., 25 mm thick
Supply of following 2C, 4sqmm size 1.1KV grade XLPE insulated, PVC Sheathed, armoured copper conductor cable conforming to IS 7098(Part 1) amended upto date
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following up to 35 sq mm in ground including excavation, sand cushioning, providing protective covering and refilling the trench etc. as required
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, on surface, recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. 8way, Double door
Supplying and fixing 240V/415V, 10 KA, “C” curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as required. a. 6 Amps SP
Supplying and fixing 240V/415V, 10 KA, “C” curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as required. a. 16 Amps DP
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in the case of recessed conduit as required a) 19/20mm dia 2mm thick
Wiring for light point/exhaust point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS, PVC insulated copper conductor single core cable as required
Installation, testing and commissioning of pre wired LED fitting of all types, complete with all accessories and tube etc. directly on ceiling/wall including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Supply of indoor decorative surface mounted LED batten with polycarbonate diffuser, along with driver, system wattage of maximum 20watts, lumen output of luminaire greater than 2000, power factor > 0.9, rated life of L70 @ 25000 hours, system efficiency greater than 100 lumen/watt and including all the necessary accessories as required complete
Supplying and laying of 63mm dia (OD 63 mm & id 51 mm nominal) DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. confirming to IS 14930, Part-II complete with fitting and cutting, jointing etc. in existing trench, complete as required
Digging of trench for laying of LT cables and refill the trench, In some places concrete & asphalt whenever removed, refixed the paver blocks, re-concrete / asphalt the road in hard soil 1.5m deep x 0.5m wide (concrete cutting)
Supplying and laying of 100mm dia B class GI pipes for culverts/drain crossing/GI Pipe/trench and cable raising, work includes supplying collars, GI clamps and GI nuts, bolts, washers for fixing pipe to drain wall complete etc
Supply of 250 mm sweep, 900 rpm light duty exhaust fan in plastic body with self-opening louvers working on 230 V AC supply complete with all accessories as required
Installation, testing and commissioning of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing & commissioning etc. as required
GK Electricals (BID ID -3097277)
M/s Anugraha power services (BID ID -3095168)
M/s. Precision Electrical Works (BID ID -3097825)
J C Electricals (BID ID -3098284)
CIS GLOBAL INFRATECH PVT LTD (BID ID -3094599)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .