Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC PLOT NO 3 DIVINE SCHOOL ROAD NEAR BJP KARYALAY PORBANDAR KHAMBHALIYA HIGHWAY BOKHIRA PORBANDAR 360 579 | PORBANDAR | GUJARAT | 360579 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.2 L+₹28,330 (0.81%)Rejected-Finance SHREE NIVAS LIMDA LANE JAMNAGAR GUJARAT PIN 361001 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.3 L+₹34,730 (0.99%)Rejected-Finance HQ CWE SUBS MUMBAI | NAGPUR | MAHARASHTRA | 440001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹50.6 L+₹15.7 L (45.0%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L4 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
16 Jun 2025, 6:00 pmClosed
GE Navy Porbandar
GE Navy Porbandar Tija Mile Porbandar
PETTY REPAIRS / MAINT / REPLACEMENT OF FITTINGS AND FIXTURES, DBS, SUBMAIN WIRINGS, ELECTRIC GEYSERS, SOLAR WATER HEATERS AND OTHER ELECTRIC WORKS AT INS SARDAR PATEL, MES COMPLEX AND NCBUNDER GE NAVY PORBANDAR
2025_MES_701482_2
9300/PBR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Navy Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹90,000
Yes
22 Jul 2025
8 May 2025
26 Jun 2025
8 May 2025
16 Jun 2025
22 May 2025
8 May 2025 - 21 May 2025
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of walls, floors, etc
Taking down unservicable/partly unservicable light fittings any type, tube light fitting and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to match with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes.
M & L for Point wiring with PVC insulated unsheathed stranded copper conductor cable FRLSH of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified .Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
One light point controlled by one, one way switch
One ceiling /exhaust fan point controlled by one switch and regulator
All as per same in item No 3 above but for one 3 pin 5 amp socket out point on the same board with other switches using 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire.
All as per same in item No 3 above but for One3 pin 5 amps socket out let point on independent board with other switches using 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire.
One bell/buzzer point controlled by one bell push.
One light point controlled by two 2-way switches
All as per same in item No 3 above but for one socket outlet 15 amp on independent board with 4.0 Sq. mm cable and 4.0 Sq.mm. earth wire.
Material and labour point wiring with 1.5 sqmm (nominal cross section area) single core PVC insulated unsheathed cable of 1100 Volts grade (FRLS) multistrand with copper conductor drawn through and including non metallic, rigid PVC conduit of adequate size with all fittings and conduit accessories concealed in wall/ceiling/floor/roof etc. including 1.6 mm thick sunk mild steel terminal box with 3mm thick plastic laminated sheet top cover,modular plate and top cover, cadmium plated iron screws for housing the switches, socket outlets including provision of 1.5 sqmm green in colour PVC insulated copper conductor single core multistrand (FRLS) for earth continuity conductor and connected to common earth dolly all as specified for the following:-
One light point controlled by one, one way switch
One ceiling /exhaust fan point controlled by one switch and regulator
All as per same in item No 4 above but for one 3 pin 5 amp socket out point on the same board with other switches using 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire.
All as per same in item No 4 above but for One3 pin 5 amps socket out let point on independent board with other switches using 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire.
One bell/buzzer point controlled by one bell push.
One light point controlled by two 2-way switches
All as per same in item No 4 above but for one socket outlet 15 amp on independent board with 4.0 Sq. mm cable and 4.0 Sq.mm. earth wire.
Supply & Fixing Modular white cover plate with frame 2 module.
Supply & Fixing Modular white cover plate with frame 3 module.
Supply & Fixing Modular white cover plate with frame 4 module.
Supply & Fixing Modular white cover plate with frame 6 module.
Supply & Fixing Modular white cover plate with frame 8 module.
Supply & Fixing Modular Metal flush box 1/2 module.
Supply & Fixing Modular Metal flush box 3 module.
Supply & Fixing Modular Metal flush box 4 module.
Supply & Fixing Modular Metal flush box 6 module.
Supply & Fixing Modular Metal flush box 8 module.
S&F of damaged U/S phenolic laminated white sheet cover 3.0 mm thick, cut into required size suitable for fixing on existing boards / terminal boxes for mounting switches, sockets, regulators as required complete all as specified & directed.
S & F switch piano flush type single pole one way/ two 5 amps.
S & F Modular switch 1 way 6A, 1 module all as specified and directed by EIC.
S & F Modular switch 2 way 6A, 1 module all as specified and directed by EIC.
S & F Socket out let 2 in one, 5/3 pin 5Amp
S & F modular socket, Socket, 6A - 2/3 pin combined 2 module all as specified and directed by EIC.
S & F Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal .
S & F Switch socket combination 5 in 1, 5 pin 16 Amps flush type universal .
S & F modular socket 16A - 2/3 pin combined 2 module, all as specified and directed by EIC.
S & F Modular switch 1 way 16A, 1 module all as specified and directed by EIC.
S & F Ceiling rose, surface bakelite 65x50 mm three terminal
S & F Call bell AC-230 Volt single pole ding dong
S & F Bell push, flush type 5 Amps.
S & F Modular bell push 6A, 1 module all as specified and directed by EIC.
S & F Electronic regulator 100/120 Watt step type
S & F Modular fan regulator120Watt, 2- module , AC 240 Volts complete.
S & F Lamp holder insulated body with back plate for angle holder all as per specified
S & F LED tube light fittings 4 feet 1x20 Watt ,220V, Indoor decorative LED Engineering Plastic batten with opal diffuser, IP 20 and with System Efficacy of 100lm/W ,holder including LED Tube light connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rose complete all as directed by Engr-In-Charge.
S & F LED tube light fittings mirror type with high output diffuser 2 feet ,1x10 Watt ,220V, Indoor decorative LED Engineering Plastic batten with opal diffuser, IP 20 and with System Efficacy of 100lm/W, holder including LED Tube light connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rose complete all as directed by Engr-In-Charge.
S & F Inverter LED batten 20Watt with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours. connecting up with 3 core flexible cppper conductor cable with sutable size from ceiling rose complete all as directed by Engr-In-Charge.
Supply and fix High brightness IP65 LED strips with uniformity of light required for perfect outdoor application Flexion AC Rope 120DStrip 6500 K IP65 complete all as specified and as directed by Engr-In-Charge.Make:-Havells Cat Part No (LHEHBPP7TN6F325) or as specified in Appx 'B'.
S & F LED luminaire upto 600 mm x 600 mm 35/36 watt , 220 V AC recessed/surface type with high effficiency PMMA diffuser soft galre free light complete with driver, holderd & LED lamp suitable for roof ceiling including connecting up with 3 core flexible cppper conductor cable with suItable size complete all as directed by Engr-In-Charge.
S & F round/square shape 15 watt 220 V AC recessed /surface type with high efficiency PMMA diffuser soft galre free light complete with driver, holderd & LED lamp suitable for roof ceiling including connecting up with 3 core flexible copper conductor cable with suItable size complete all as directed by Engr-In-Charge.
S & F decorative wall light , gold finish fixture with white glass diffuser suitable for 7.5 W LED filament lamp E27 base including its lamp & connecting up with flexible copper conductor cable with suItable size complete all as directed by Engr-In-Charge.
S & F of LED indoor Wall light 3W, Aluminium, White, 220-240 V , wall mounted for study purpose complete all as directed by Engr-In-Charge.
S& F of LED Bollard light 8 to 10 Watt New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source. with neceesary mounting foundation and connecting with flxible copper cable of suitable size complete all as directed by Engr-In Charge
S& F of LED Bollard light 8 to 10 watt inverted Pyramid Tripod Type LED Bollard with soft 360 degree distribution with neceesary mounting foundation and connecting with flxible copper cable of suitable size complete all as directed by Engr-In Charge.
S& F LED post top lantern 35 watt with with die cast aluminium IP 65 5700 K alongwith neceesary mounting foundation and connecting with flxible copper cable of suitable size complete all as directed by Engr-In Charge.
Supply and fixing LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp & connecting up with flexible copper conductor cable with suItable size complete all as directed by Engr-In-Charge.
S & F LED street light fittings 1x25 Watt , 230V, AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, surge protector with intact and corrosion resistant including thermal management in muliple optics complete with IP65/66 protection including suitable size GI bracket of suitable length and clamps, nut ,bolts etc complete all as directed by Engr-In-Charge. Make:- Crompton Cat Part No:- LSTS-25 -CDLor as specified in Appx 'B'.
S & F Fabricate,supply & fix GI pipe light grade bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for security light fitting complete all as directed by Engr-In-Charge.
S & F earth enclosure with 2 pin earth plug sokcet complete with MCB SP 25 amp,flush mounting type
S & F triple pole and earth enclosure with a three pin and earth plug with sokcet complete with one triple pole MCB 32 Amp
S & F triple pole and earth enclosure with a three pin and earth plug with sokcet complete with one triple pole MCB 63 Amp
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 1.5 Sqmm, earth continuity conductor of size 1.5 Sqmm to be drawn through and including PVC CASING CAPING/PVC Conduit not less then 20mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 1.5 sqmm and one wire of 1.5 sqmm and one run of PVC casing caping/Conduit shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC CASING CAPING/PVC Conduit not less then 20mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 2.5 sqmm and one wire of 2.5 sqmm and one run of PVC casing caping/Conduit shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC CASING CAPING/PVC Conduit not less then 25mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC casing caping/Conduit shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC CASING CAPING/PVC Conduit not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 6 sqmm and one wire of 6.0 sqmm and one run of PVC casing caping/Conduit shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 10 Sqmm, earth continuity conductor of size 10 Sqmm to be drawn through and including PVC CASING CAPING/PVC Conduit not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i) Two wires of 10sqmm and one wire of 10 sqmm and one run of PVC ccasing caping/Conduit shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 4 Single core of size 4 Sqmm, earth continuity conductor of size 1X 4.0 Sqmm to be drawn through and including PVC casing caping/ PVC Conduit not less then32mm dia medium Grade all as directed by Engineer in Charge.Notes:- (i) four wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 4 Single core of size 6 Sqmm, earth continuity conductor of size 1X 6 Sqmm to be drawn through and including PVC casing caping/PVC Conduit not less then32mm dia medium Grade all as directed by Engineer in Charge.Notes:- (i) four wires of 6 sqmm and one wire of 6 sqmm and one run of PVC conduit shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 4 Single core of size 10 Sqmm, earth continuity conductor of size 1X 10 Sqmm to be drawn through and including PVC casing caping/PVC Conduit not less then 32mm dia medium Grade all as directed by Engineer in Charge.Notes:- (i) four wires of 10 sqmm and one wire of 10 sqmm and one run of PVC conduit /casing caping shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 1.5 Sqmm, earth continuity conductor of size 1.5 Sqmm to be drawn through existing steel/PVC conduit fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 1.5 sqmm and one wire of 1.5 sqmm shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through exsisting steel/PVC conduit fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 2.5 sqmm and one wire of 2.5 sqmm shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through exsisting steel/PVC conduit on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 4 sqmm and one wire of 4.0 sqmm shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through exsisting steel/PVC conduit fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 6 sqmm and one wire of 6 sqmm shall be measured as one unit.
S & F Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable FRLSH 2 Single core of size 10 Sqmm, earth continuity conductor of size 10 Sqmm to be drawn through exsisting steel/PVC conduit on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 10sqmm and one wire of 10 sqmm shall be measured as one unit.
Dismantling unserviceable main switch/ kitkat DBs/ MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces
S & F MCCB DB VERTCLE TYPE made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade ,Glazed door 415 Volts TPN with 4 way Double door
S & F MCCB DB VERTCLE TYPE made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade ,Glazed door 415 Volts TPN with 8 way Double door
S & F MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door
S & F MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 6 way Double door
S & F MCB DB made of sheet steel, powder painted with bus bar 200 A, neutral link, earth bar and Din rail , 240Volts SPN with 4 way Double door IP-43-IK09 protection grade
S & F MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail ,240Volts SPN with 8 way Double door , IP-43-IK09 protection
S & F MCB DB made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, earth bar and Din rail , 240Volts SPN with 12 way Double door IP-43-IK09 protection grade,
NOTE FOR ITEM NO 64 TO 70 -(1).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall./ DB tobe fixed on wall including frame made out of MS flat 40x5mm and for making good the disturbed surfaces including finishes to match with the adjoining surface. (2) Rate is also inclusive of cutting chaseS & F in repair lush to wall & making good to the disturbed surfaces of walls etc to match with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes making good disturbed surfaces of walls, etc )
S & F MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 40 to 63Amps
S & F MCB TP 415 Volts, 'C' series, breaking capacity 10 KA of rating 25 to 63 Amps
S & F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 40 to 63Amps
S & F MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps
S & F MCB SP 240 Volts 'C' series, breaking capacity 10 KA of rating 6-32 Amps
S & F RCCB DP 100 mA of rating 25 Amps
S & F RCCB DP 100 mA of rating 40 Amps
S & F MCCB 4P 63 Amps , 415Volts, 16 KA
S & F MCCB 4P 100 Amps , 415Volts, 16 KA
S & F MCCB 4P 125 Amps , 415Volts, 16 KA
Refixing of servicable MCB SP 6-32 AMPS
Refixing of servicable MCB SPN 32 -63 AMPS
Refixing of servicable MCB TP 25 -63 AMPS
Refixing of servicable MCB TPN 16 -100 AMPS
.M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing strip of 4mm x 25 mm dia galvanised iron or steel strip all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion
Taking down fan of any make/type/sweep,sealing cable end ,dismantling of blades and for repair /overhauling complete all as directed
M &L for Overhauling of ceiling fan /wall fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, and testing on completion all as specified and as directed .(Note- (A) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (B) The spares (bearing , bush,capacitor) required shall be measured and paid separately in the relevant items).
Repair of ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spare parts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and supply and fixing the following items and including necessary transportion to workshop, for 1200/1400/1500mm sweep fan :- (i) Split pin - 02 Nos (ii) Connection block - 1 No (iii) Insulation rubber bush - 01 No
Fixing or hanging only ceiling fan after overhauling/repair of winding above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
M &L for Painting of ceiling fan/Exhaust Fan/Wall mounted fan of any sweep complete including fan blade down rod with synthetic enamelled paint by spraying including cleaning and removing dust by polish paper and dirt and making smooth surface for painting ,filling cavities with filler
Taking down exhaust fan, of any size and type for cleaning/servicing by sealing cable end, dismantling blades and removing fan and dismantling all electrical connection and including necessary transportion to workshop/store complete all as specified and as directed.
M &L for Repair of exhaust fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spare parts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and refixing the same back to its origibal position including necessary transportion to workshop, 225 to 300 mm sweep
M & L for Fixing Exhaust fan after complete overhauling of exhaust fan as required at site and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
S & F gun metal bush of any size
S & F bearing suitable for ceiling fan /wall mounted fan any type
S & F fan condensor upto 2.5 MFD (Make – USHA / UNIVERSAL).
S & F fan condensor 4 MFD (Make – USHA / UNIVERSAL).
S & F canopy of ceiling fan bottom and upper side of size 1200/1400/1500mm
M& L for opening the geyser 25/50 ltr capacity and taking out inner tank and glass wool from inside the geyser , descaling & washing with acid to remove the scales, dirt etc if any and refixing the same after reassembly into geyser and proper filling of new glass wool around inner tank complete all as specified & directed ( NOTE:- Glass wool will be measured & paid separately under relevant item of the schedule)
S & F Glass wool pf any colour complete all as directed by Engineer-in-Charge
S & F of Geyser inner water storage tank of any type capacity 25 ltr make of metal stainless steel as specified and directed
S & F heating element 1000 watt make of Bajaj / Tosiba / Havells / as suitable for geysers make all as specified and directed by Engineer –in-Charge
S & F heating element 1500 watt make of Bajaj / Tosiba / Havells / as suitable for geysers make all as specified and directed by Engineer –in-Charge
S & F heating element 2000 watt make of Bajaj / Tosiba / Havells / as suitable for geysers make all as specified and directed by Engineer –in-Charge
S & F themostat for geyser make of Bajaj / Tosiba / Havells / as suitable for geysers make all as specified and directed by Engineer –in-Charge
S & F neone lamp for geyser yellow / red as directed by Engineer –in-Charge
S & F air realese valve for geyser as specified and directed
S & F geyser hot & cold water connection hose of size 450/600 mm long armoured type both side brass union type nuts complete including removal of old pipe as specified and directed
S & F anchor bolts 75mm long made out of stain less steel complete all as specified and directed
S & F PVC insulated and FR PVC Round Sheathed , copper conductor (flexible) industrial cable of size 1.5 Sqmm 3 core, 1100 volt, conforming to IS 694 complete all as specified and directed
S & F plug top 3 pin 15 Amps 240 V,ISI complete all as specified and directed
S & F wooden frame of suitable size and dimenssion for fixing of exhaust fan in exisiting hole includig fixing material requied at site complete all as specified & directed.
S & F PVC globe/gate valve with plastic knob, socket on both ends for UPVC pipe, ISI marked of size 25 mm bore complete all as specified & directed.
S & F PVC globe/gate valve with plastic knob, socket on both ends for UPVC pipe, ISI marked of size 20 mm bore complete all as specified & directed.
S & F 20 mm outer dia CPVC pipes ,SDR 11 & plain CPVC SDR11 fittings on walls/ceiling or laying on floors complete all as specified & directed.
S & F 25 mm outer dia CPVC pipes ,SDR 11 & plain CPVC SDR11 fittings on walls/ceiling or laying on floors complete all as specified & directed.
M & L for cleaning of solar water tank by removing all scale & dirt , etc from mouth of circulating pipes etc of tank capacity upto 500 Ltrs complete all as specified & directed.
Cutting of holes in wall for fixing of exhaust fan of size upto 450mm & making good damaged area by rendering in cement mortar 1:4 complete all as specified & directed.
M/s super construction (BID ID -3307689)
SHREE KEDARNATH ENTERPRISE (BID ID -3323015)
JAY BHARAT METAL SUPPLIERS (BID ID -3314963)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .