| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC Deducts after sch of credit | |
| 2 | L2₹6.1 L+₹65,982 (12.2%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
20 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Nagtalao
Military Engineer Services AGE I Nagtalao PIN 342037 c/o 56 APO
Preventive Corrective Maintenance and repairs to Central Air cooling system at Nagtalao under AGE I Nagtalao
2021_MES_426498_1
8141/20-21/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE I Nagtalao
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I Nagtalao
₹16,000
Yes
17 May 2021
1 Mar 2021
22 Mar 2021
1 Mar 2021
20 Mar 2021
8 Mar 2021
60 days
Amount
M&L for servicing of blower of Central Air Cooling System of capacity 12000 CFM by dismantling complete form enclosure of air cooling sysytem Air Blower, V Belts, Motor of Blower, Air Filters, Pulley & Shafts of Air Blower, expansion duct etc. replacement of all spares of air blower as required. Making alignment of pulley, motor and V Belts properly, oiling and greasing of bearings etc.Cleaning of complete body of central air cooling system with water and anti sealant solution, cleaning of dusts of filter by high pressure air blower, washing of fins evaporative air cooling pads by anti sealant solution. all as directed by Engineer-in-Charge.
All as per Item No 01 above but for 8000 CFM
All as per Item No 01 above but for 5000 CFM
All as per Item No 01 above but for 3000 CFM
M & L for painting to air cooling system incl air blower complete body inside and outside both of 12000 CFM two coats of synthetic enamel paint (First quality, shade silver grey of approved Make-Nerolac paint (hi gloss) Asian Paint (Apcolite) Berger paints (Luxol Higloss) all as directed by Engr-in Charge.
All as per Item No 05 above but for 8000 CFM
All as per Item No 05 above but for 5000 CFM
All as per Item No 05 above but for 3000 CFM
Dismantling old damaged Evaportive cooling pads from Central Air Cooling System and Supply and fix 150-200 mm thick Evaportive cooling pad complete and all as directed by Engr-in-Charge. Make:- Munters or equivelent.
Disconnecting existing electric motor and dismantling from foundation and trasporting the same to workshop for repairs and re-fixing the same on existing location after repair including taking out of burnt out winding & rewinding the motor with super enamelled copper wire as per existing guage and size and making electric connection including testing and commissioning complete of capacity 7.5 HP three phase induction motor all as directed by Engr-in Charge.
All as per Item No 10 hearin before but 5.5 HP Three phase Induction motor.
All as per Item No 10 hearin before but 3.5 HP Three phase Induction motor.
S & F in repair bearing as per existing size for 3 phase induction motor of capacity 7.5 HP Three phase Induction motor all as directed by Engr-in Charge.
All as per Item No 13 hearin before but 5.5 HP Three phase Induction motor.
All as per Item No 13 hearin before but 3.5 HP Three phase Induction motor.
Supply and fix in repair bearing of existing size of air blower as per existing make and size
Supply and fix in repair panel mounted type 3 pole power contactors 32 Amp 3 phase MNX type with suitable auxiliary contact top 2 NO + 2 NC type suitable for 3 phase induction motor of type MNX-18 Cat part No CS94111 of Make L&T/S&C
Supply and fix in repair panel mounted type on/off push Button with led glow type as per existing sample and all directed by Engr-in-charge.
Supply & fix in repair panel mounted type indicator lamp led glow type with colour code red and green type.
Supply & fix V Belts of Size A-44
Supply & fix V Belts of Size A-55
Supply & fix V Belts of Size B-78
Supply & fix V Belts of Size B-82
Supply and fix water lifiting pump of submersible type of Single Phase Electric Driven of 220 - 240 V ,50 Hz , 100 W,Head 7 Mtrs , Flow Rate 5000 LPH and delevery dia 20 mm all as directed by Engr-in-Charge. Make:- AKVO/Bajaj/CG or equivalent
Supply and fix in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass ferrule 20 mm bore weight not less than 210 gms complete.
Supply and fix in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe or brass ferrule 15 mm bore weight not less than 142 gms complete.
Supply & Fix MCCB 16 KA 63 Amp four pole 415 V. all as directed by Engr-in - chage
Supply & Fix MCCB 16 KA 100 Amp four pole 415 V. all as directed by Engr-in - chage
Supply & Fix single phase preventor in DOL strater of capacity 3.5 HP to 7.5 HP motor with necessary connection by flexible copper wire of suitable size. all as directed by Engr-in - chage
Supply & Fix AVM pad of size 100 X 100 X 75 mm all as directed by Engr-in - chage
Supply & Fix powder coated aluminium grill of existing size all as directed by Engr-in - chage
Taking down old unserviceble cable tray, M&L for Galvanised iron cable tray 600 x100 mm fixing on wall/roof or in floor with means of screw,welding at suitable height all as directed by Engr-in-charge .
S& F fabricated stand angle iron, size of angle 20X20 mm , 3.0 mm thicks and fixing on roof/floor as directed by engg in charge.
Repairs and replacement foundation of blower motor fitted in side the Central Air Cooling System of capacity 3.5 HP to 7.5 HP and supply and fix with new MS channel of size 75X40 mm, 3.15 mm thick and making the long groove of 10 mm wide and 200 mm long for slide the motor with center nut and long bolt ( 10 mm dia) arrangement for sliding the motor for tighten or loose the fan belt with complete all as directed by Engr-in-Charge.
Supply and fix PGI Sheet cover of size 900 mm X 900 mm and 1.219 mm (18 gauge) thick on induction motor in side the cooling system of any capacity with iron rivets of suitable size all as directed by Engr-in - chage
Supply and fix pad lock 7 levers with 3 Nos keys size 50mm to lock the cooling machine complete Make Godrej all as directed by Engr-in-Charge.
Taking down old unserviceble cable & M&L for PVC insulated aluminium conductor 1100 volts grade heavy duty electric cable with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of cross-sectional area 16 Sq mm 4 core.
Taking down 25 mm bore GI tubing any grade with all fittings laid in trenches all as directed by Engineer-in-Charge.
All as per Item No 41 above hearin before but for 20 mm bore.
All as per Item No 41 above hearin before but for 15 mm bore.
Supply and Laying 25 mm bore GI tubing of mediu grade with akk fittings laid in trenches all as directed by Engr-in-Charge.
All as per Item No 44 above hearin before but for 20 mm bore.
All as per Item No 44 above hearin before but for 15 mm bore.
Supply & fix GI nipple of size 15 mm dia in 150 mm length of medium grade with all fittings laid in trenches all as directed by Engineer-in-Charge.
S & F stop valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for of 25mm bore GI tubing
All as per Item No 48 above hearin before but for 20 mm dia.
All as per Item No 48 above hearin before but for 15 mm dia.
Supply and fix PVC flexible pipe heavy duty with 20 mm dia
Taking out panel door and air cooling machine door with old broken hinges and supply and fix with new MS hinges medium weight of 75mm long fix to panel & panel door and cooling machine & machine door with suitable nut & bolt /welding and painting to match the existing colour of panel & refixing the same complete all as specified and directed
M&L for painting of LT panel of size 2.56 Sqm approx not exceeding 3.24 Sqm incl angle iron frame. with two coats of synthetic enamel paint First quality approved Make all as directed by Engr-inCharge.
M&L for plate earthing for LT panel with galvanised mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other, earth strip encased in and including 40mm bore GI medium grade pipe with all fittings from top of electrode to body of equipment fixed with and including 40 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work , etc.complete all as specified and shown in electrical plate No 3 of SSR Pt-I.
Supply and lay of GI strip of 32x6mm burried in ground or drawn in conduit/pipe or fixed on wall/pole as required at site complete as directed by Engr-in-Charge.
M&L cement concrete in surface channels any thickness, size or shape including pilasters type (1:2:4), Type B-2 using 40mm graded stone aggregate (including caps and bases) incl formwork.
Supply and fix Tarpoline expansion duct connetion of existing size with nuts and bolts and iron strip or as per site requirement all as directed by Engr-in - chage.
Supply and fix in repair G I sheet of 1.829 mm ( 15 gauge) water storage tank in air cooling system including cut in to shape ,bending and gas welding corner of the tank and painting inside surface with rubber paint and outside with synthetic enamel paint etc including necessary fabrication work and confirm to no water leakage. complete all as specified and directed.
M&L for dismantling air blower parts and replacement of air rotor complete incl transportation of air blower from workshop and back and fixing in position including all necessary arrangement as directed by engg in charge for capacity 12000 CFM.
M&L for dismantling air blower parts and replacement of air rotor complete incl transportation of air blower from workshop and back and fixing in position including all necessary arrangement as directed by engg in charge for capacity 8000 CFM.
M&L for dismantling air blower parts and replacement of air rotor complete incl transportation of air blower from workshop and back and fixing in position including all necessary arrangement as directed by engg in charge for capacity 5000 CFM.
M&L for dismantling air blower parts and replacement of air rotor complete incl transportation of air blower from workshop and back and fixing in position including necessary arrangement such as key etc as directed by engg in charge for capacity 3000 CFM.
vinayandsons
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .