| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹6.5 L+₹67,996 (11.6%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹7.0 L+₹1.1 L (19.5%)Rejected-Finance A 16 SHIV LOK COLONY RAJPUR ROAD DEHRADUN 248 008 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248008 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹7.5 L+₹1.7 L (29.0%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹7.7 L+₹1.9 L (32.0%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
5 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RnD haldwani
AGE I RnD haldwanipo Arjunpur
REPAIR/REPLACEMENT OF INTERNAL ELECTRIC SUPPLY AND CONNECTED MISC WORKS AT FD STATION DIBER PITHORAGARH
2020_MES_375325_2
AGE I RnD/HLD/18 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
DIBER pithoragarh
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RnD haldwani
₹16,000
Yes
11 Dec 2020
8 Oct 2020
9 Nov 2020
8 Oct 2020
5 Nov 2020
24 Oct 2020
8 Oct 2020 - 21 Oct 2020
60 days
Amount
Contract Details
Taking down carefully Copper/Aluminium point wiring (Light fan socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc), removing materials from site and making good disturbed surface of walls, floors etc, complete all as specified and directed.
Taking down carefully by disconnecting electrical connection, main switches / distribution board / MCB DB with MCBs of any rating, removing dismantled material from site and making good disturbed surface of walls to match with existing all as directed.
Taking down Sub main wire /Service wire of any size, fixed in any position, complete all as specified and directed.
M&L for point wiring Concealed type with 1.5 Sqmm, single core (FRLS), PVC insulated with multistranded unsheathed copper conductor cable including rigid non- metallic PVC surface / concealed conduit 20 mm or higher dia, light grade ISI marked complete with all PVC conduit accessories / fittings and sunk switch boxes with 3 mm thick plastic laminated hard glossy surface sheet (white) top cover, including continuous earth wire of PVC insulated, unsheathed, green in colour 1.5 Sqmm multistrand copper conductor (FRLS) connected to all fittings, sunken boxes and common earth and connected to earth dolly , screwed with Brass screws, cup washers complete all as specified and directed for the following :-
(a) One light point//Ceiling Fan/ exhaust fan point/bell point controlled by one, one way switch of 5/6 Amps.
(b) One 3 pin socket outlet 5 Amp on same board with other switch
(c) One 3 pin 5/6 amps socket out-let point on independent board controlled by one, one way switch of 5/6 amps on independent board.
All as per item 4 herein above but with 4 Sq mm cable (FRLS) for one 15 Amp socket outlet controlled by one switch on independent board and 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable as continuous earth wire complete.
One light point controlled by two 2 way switches, with cables1.5 sq. mmsize
S & F in replacement of Switch piano, flush type, white finish, 5/6 amps, single pole, one way.
Ditto, but 15 Amp 2 way.
S&F in replacement of socket outlet 3 pin, 5/6 amps and 2 pin 5/6 amps flush type, complete all as specified and directed.
S&F in replacement of ceiling rose, surface bakelite, AC, 220/240 volts, 3 terminals, complete all as specified and directed.
S&F lamp holder, insulated body with back plate suitable for batten /angular fittings, fixed on with & including round block 8 cm dia, 4 cm depth, closed recessed type & making connection etc complete all as specified & directed.
S&F in replacement of Switch piano flush type, white finish, 15/16 amps, single pole, one way, complete all as specified and directed.
S&F in replacement of Socket outlet two in one 3 pin 5/6 amps and 3 pin 15/16 amps (multipurpose), flush type, non shutters, non inter locking type, complete all as specified and directed.
S&F in replacement of MCB DB sheet metal enclosure for DB, TPN, 4 way having protection with 200 amps bus bar, neutral bar, earth bar 415V double door, including grauting suitable for housing MCB's with separate netural & earth link complete all as specified and directed. Make-L&T and equivalent
S&F in replacement of MCB DB sheet metal enclosure for DB, SPN, 12 way having protection with 200 amps rated bus bar, 240 volts, double door type, suitable for housing MCB's and isolators,concealed in wall complete all as specified and directed. Make-L&T and equivalent
ditto, but 8 way. Make-L&T and equivalent
ditto, but 4 way. Make-L&T and equivalent
Supply and Fix in replacement of MCB single pole, 240 volts, 6-32 Amps of 10 KA complete all as specified and directed. Make-L&T and equivalent
Supply and Fix in replacement of MCB single pole, 240 volts, 40 Amps of 10 KA complete all as specified and directed. Make-L&T and equivalent
Supply and Fix in replacement of MCB single pole, 240 volts, 63 Amps of 10 KA complete all as specified and directed. Make-L&T and equivalent
Supply and Fix in replacement of MCB DP, 240 volts, 6-32 Amps of 10 KA complete all as specified and directed. Make-L&T and equivalent
Supply and Fix in replacement of MCB DP, 240 volts, 40 Amps of 10 KA complete all as specified and directed. Make-L&T and equivalent
Supply and Fix in replacement of MCB DP, 240 volts, 63 Amps of 10 KA complete all as specified and directed. Make-L&T and equivalent
Supply and Fix in replacement of MCB TP, 240 volts, 63 Amps of 10 KA complete all as specified and directed. Make-L&T and equivalent
S&F in replacement of MCB TPN 240 volts, 63 amps, of 10 KA Make-L&T and equivalent
S&F in replacement of single phase automatic changeover switch 30/30 amps Make-L&T and equivalent Make-L&T and equivalent
Supply and Fix in replacement of RCCB/ELCB DP, 240 volts, 40 Amps of 30 MA complete all as specified and directed. Make-L&T and equivalent
Supply and Fix in replacement of RCCB/ELCB DP, 240 volts, 63 Amps of 30 to 300MA lete all as specified and directed. Make-L&T and equivalent
S&F in replacement decorative ultra slim bedside light 3watt LED warm White with extruded energy efficient, complete all as specified and directed. Make - hilips 48042 or equivalent
S&F in replacement Oreva Power Link 4 Way Extension Cord - 4 Meter cable complete all as specified
S&F Regal Batten for LED tube (Universal Batten for T5 and T8 lamp) upto 1x22 watt and including Crystal Glass LED Tube Light 20 Watt (Double Side Connection) suitable for installation in T8 fitting with G13 Lamp Holders complete all as specified. Make- Havells, Item Description for Batten-REGALBATTENT8UPTO1X22WSSBSWH, Item Description for LED Tube-CRYSTAL1213T8 DSTLED 865S GLASS or equivalent
S&F surface mounted LED down light 12 watt complete all as specified and as directed Cat pt No crompton LCDSPLN-R-12-CDL/NW/WW
S&F surface mounted LED down light 40 watt complete all as specified and as directed Cat pt No crompton LCSUR6-40--CDL/TL/WW
S&F decorative wall mounted brushed nike finished fixture with opal glass diffuser including 12 watt LED bulb B22 based complete all as specified and as directed Cat pt No LHFOAJE2TZ1i060
M&L for replacement of Sub main wiring with two single run of 6 Sqmm (Normal cross sectional area) of single core unsheathed PVC insulated cable, 1100 volts grade multi stranded copper conductor drawn through with & including conduit of 25 mm dia or higher dia with and including necessary conduit accessories, surface/ concealed type including 4 Sqmm stranded copper conductor PVC insulated cable as earth wire connected to common earth dolly, complete all as specified and directed. Note :- The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface.
Disconnecting, dismantling and taking out the existing unserviceable items of any description, any make and in any position and refixing new supply & fix aluminium 1100 volt grade heavy duty cable PVC insulated aluminium conductor service connection cable twin core flat cable stranded conductor 10sqmm Make: plaza /Havells/Kalinga/ polycab
Disconnecting and taking out the existing energy meter from incoming outgoing supply fixed in box incl MCB DB of any size for repair and replacement of new C of size 400mm x 200mm x 180mm of 3mm thick made out of galvanise iron sheet suitable for housing MCB's and isolators, quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the new meter box to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface, removing materials to store for keeping in safe custody for reuse/ refix at site complete all as specified and directed.
Material and Labour for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 6.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 2009 part – I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 6 mm dia galvanized iron or steel wire including necessary excavation of hard standing/stone and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thck in RCC 1:2:4 type B1 duly reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and GI protection pipe light grade 15 mm dia beyond 7.5 mtr from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade & funnel etc. complete all as specified and directed. Note :- The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the GI wire pipe to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface.
Note :-Tenderers may be noted that amount of credit will be deducted from the total amount arrived, at the time of Acceptance of contract.
SIDDHIDATI CONSTRUCTION
Amit Engineering
M/S Pooja Construction
DIKSHA CONSTRUCTION CO
SEEMA ELECTRICAL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .