Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC 0 ARAMPORA AL HADEES MASJID NAWAKADAL SRINAGAR SRINAGAR JAMMU KASHMIR 190002 | SRINAGAR | JAMMU AND KASHMIR | 190002 | ₹37.3 L Quoted ₹38.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹51.2 LRejected-Finance COLABA MUMBAI | ₹51.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹56.0 LRejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹56.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹58.5 LRejected-Finance | ₹58.5 L | L4 | Rejected-Finance L4 |
| Sl No | Description | Qty | Unit | Veer High Tech Solution L2 | Shree Ayyappa Engineering L3 | Bharat Enterprise L1 | shubham construction L4 |
|---|---|---|---|---|---|---|---|
| 1.00Servicing of DG set by deputing OEM service representative to attend the DG set regularly to carrying out scheduled preventive maintenance checks on diesel generating set (of any Make and carryout the Starting system, Fuel injection system, Transmission system, generation system, Battery check up, Alternator check etc. check/works during the calender year all as directed by Engg-in-charge.Carry out maintenance/check as per maitenance schedule during every visit as per contract. Note 1 : All major spare parts costing above Rs. 500 will be measured & paid separately. Note 2 : Minor Spare parts costing upto Rs. 500 deemed to be included the rate quoted by the contractor for comprehensive/routine maint. Note 3 : Periodical testing register shall be maintained at site and produced to Engg-in- charge for sign on monthly basis. Note 4 : All Routine maintenance/testing shall be done through Specialist agency. Note for Servicing items of the Schedule ITEM NO 1 Note:- 1) The above Item Includes following a) Labour Charges tools/gauges for Major and Minor repairs including Overhauls b) Labour charges for all unlimited Breakdown Complaints related to Genset for a period of one year c) Preventive Maintenanace 4 visit in a Contract period to carry out Inspection of 61 Check points of DG sets Note:- 2) The above Item excludes following a) Cost of consumables and spares parts require for preventive or breakdown Visits b) Charges for external job works lke FIP-Starter-Charging alternator repairing, AC Alternator Repairing, Machining required for any part of Genset. Note :-3) The Spare Parts, engine Oil & Premix Coolant used for work under contract must be 'Greaves Lub Oil ' genuine / recommended by OEM Purchased from Authorised Greaves Cotton Ltd Service & Spare Dealership. Note:-4) All works under contract must be carried out by Kirloskar/Greaves Cotton Ltd Trained Service Engineers from Local Autorised Greaves Cotton Ltd Service & Spare Dealership to have a quick /urgent hastle free service to restore the system in minimum time frame Note:-5) The Minor Brakdown Complaints will be attended within 4 Hrs & should be rectified 24 Hrs by Trained Service Engineers from Local Autorised Service & Spare Dealership. Note:-6) Contractor has to collabrate with "Kirlskar/Greaves Cotton Ltd" Service Package from Authorised Dealer of Kirloskar/Greaves Cotton Ltd after acceptance of contract | |||||||
| 1.01 | All as per item No.1.0 diesel engine driving generating set of capacity 250 KVA located at (Junior/ Senior Sailor Block, NSB) - 02 Nos | 8 | Each Job | 5,999 ₹47,992 | 6,000 ₹48,000 | 4,900 ₹39,200 | 6,250 ₹50,000 |
| 1.02 | All as per item No.1.0 Diesel engine driving generating set of capacity 160 KVA, located at (NAE Hanger 343, NAE Hanger 343, Auditorium INS SP, NCN and DCN INS SP) - 05 Nos | 20 | Each Job | 5,302 ₹1.1 L | 5,300 ₹1.1 L | 4,300 ₹86,000 | 5,500 ₹1.1 L |
| 1.03 | All as per item No.1.0 diesel engine driving generating set of capacity 125 KVA located at (Golf Course Nofra,TS INS Sardar patel, Comcen)- 03 Nos | 12 | Each Job | 5,023 ₹60,276 | 5,500 ₹66,000 | 4,200 ₹50,400 | 5,000 ₹60,000 |
| 1.04 | All as per item No.1.0 Diesel engine driving generating set of capacity 100 KVA, located at (Logistic and Technical complex INS Sardar patel) - 02 Nos | 8 | Each Job | 4,744 ₹37,952 | 5,000 ₹40,000 | 3,600 ₹28,800 | 5,500 ₹44,000 |
| 1.05 | All as per item No.1.0 diesel engine driving generating set of capacity 75 KVA located at (Pump House INS Sardar Patel and Ward room) - 02 Nos | 8 | Each Job | 4,186 ₹33,488 | 4,500 ₹36,000 | 3,000 ₹24,000 | 4,800 ₹38,400 |
| 1.06 | All as per item No.1.0 Diesel engine driving generating set of capacity 62.5 KVA located at (Technical Storage Shed INS SP) - 01 No. | 4 | Each Job | 3,907 ₹15,628 | 3,900 ₹15,600 | 2,750 ₹11,000 | 4,400 ₹17,600 |
| 1.07 | All as per item No.1.0 Diesel engine driving generating set of capacity 50 KVA located at (MET Complex NAE) - 01 No. | 4 | Each Job | 3,767 ₹15,068 | 4,000 ₹16,000 | 2,750 ₹11,000 | 3,750 ₹15,000 |
| 1.08 | All as per item No.1.0 Diesel engine driving generating set of capacity 40 KVA (located at Hanger 343 NAE) - 02 No. | 8 | Each Job | 3,488 ₹27,904 | 4,000 ₹32,000 | 2,500 ₹20,000 | 4,500 ₹36,000 |
| 1.09 | All as per item No.1.0 diesel engine driving generating set of capacity 30 KVA located at (Navy House, Nofra) - 01 Nos | 4 | Each Job | 3,349 ₹13,396 | 3,750 ₹15,000 | 2,300 ₹9,200 | 4,000 ₹16,000 |
Updated dates
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
27 Nov 2025, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
REPAIR/ MAINTENANCE OF FIRE FIGHTING SYSTEM/ FIRE ALARM SYSTEM, EOT CRANES, DG SET AND ALLIED WORKS AT NAVAL BASE PORBANDAR UNDER GE (NAVY) PORBANDAR
2025_MES_737649_1
8920/E8
Open Tender
Electrical and Maintenance Works
273 days
PORBANDAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (N) PORBANDAR
₹92,000
10 Jan 2026
30 Oct 2025
29 Nov 2025
30 Oct 2025
27 Nov 2025
13 Nov 2025
Amount
Servicing of DG set by deputing OEM service representative to attend the DG set regularly to carrying out scheduled preventive maintenance checks on diesel generating set (of any Make and carryout the Starting system, Fuel injection system, Transmission system, generation system, Battery check up, Alternator check etc. check/works during the calender year all as directed by Engg-in-charge.Carry out maintenance/check as per maitenance schedule during every visit as per contract. Note 1 : All major spare parts costing above Rs. 500 will be measured & paid separately. Note 2 : Minor Spare parts costing upto Rs. 500 deemed to be included the rate quoted by the contractor for comprehensive/routine maint. Note 3 : Periodical testing register shall be maintained at site and produced to Engg-in- charge for sign on monthly basis. Note 4 : All Routine maintenance/testing shall be done through Specialist agency. Note for Servicing items of the Schedule ITEM NO 1 Note:- 1) The above Item Includes following a) Labour Charges tools/gauges for Major and Minor repairs including Overhauls b) Labour charges for all unlimited Breakdown Complaints related to Genset for a period of one year c) Preventive Maintenanace 4 visit in a Contract period to carry out Inspection of 61 Check points of DG sets Note:- 2) The above Item excludes following a) Cost of consumables and spares parts require for preventive or breakdown Visits b) Charges for external job works lke FIP-Starter-Charging alternator repairing, AC Alternator Repairing, Machining required for any part of Genset. Note :-3) The Spare Parts, engine Oil & Premix Coolant used for work under contract must be 'Greaves Lub Oil ' genuine / recommended by OEM Purchased from Authorised Greaves Cotton Ltd Service & Spare Dealership. Note:-4) All works under contract must be carried out by Kirloskar/Greaves Cotton Ltd Trained Service Engineers from Local Autorised Greaves Cotton Ltd Service & Spare Dealership to have a quick /urgent hastle free service to restore the system in minimum time frame Note:-5) The Minor Brakdown Complaints will be attended within 4 Hrs & should be rectified 24 Hrs by Trained Service Engineers from Local Autorised Service & Spare Dealership. Note:-6) Contractor has to collabrate with "Kirlskar/Greaves Cotton Ltd" Service Package from Authorised Dealer of Kirloskar/Greaves Cotton Ltd after acceptance of contract
All as per item No.1.0 diesel engine driving generating set of capacity 250 KVA located at (Junior/ Senior Sailor Block, NSB) - 02 Nos
All as per item No.1.0 Diesel engine driving generating set of capacity 160 KVA, located at (NAE Hanger 343, NAE Hanger 343, Auditorium INS SP, NCN and DCN INS SP) - 05 Nos
All as per item No.1.0 diesel engine driving generating set of capacity 125 KVA located at (Golf Course Nofra,TS INS Sardar patel, Comcen)- 03 Nos
All as per item No.1.0 Diesel engine driving generating set of capacity 100 KVA, located at (Logistic and Technical complex INS Sardar patel) - 02 Nos
All as per item No.1.0 diesel engine driving generating set of capacity 75 KVA located at (Pump House INS Sardar Patel and Ward room) - 02 Nos
All as per item No.1.0 Diesel engine driving generating set of capacity 62.5 KVA located at (Technical Storage Shed INS SP) - 01 No.
All as per item No.1.0 Diesel engine driving generating set of capacity 50 KVA located at (MET Complex NAE) - 01 No.
All as per item No.1.0 Diesel engine driving generating set of capacity 40 KVA (located at Hanger 343 NAE) - 02 No.
All as per item No.1.0 diesel engine driving generating set of capacity 30 KVA located at (Navy House, Nofra) - 01 Nos
All as per item No.1.0 Diesel engine driving generating set of capacity 20 KVA, (located at MES Complex)
Supply and fix in repairs replacement of following misc items capacities of 250 KVA DG Sets at NSB (02 Nos) :-
Fuel filter
Lub Oil filter
By pass oil filter
Air filter (inner and outer)
Fuel injector
Fuel connectors high pressure pipes
Radiator fan belt
Supply and fix in repairs replacement of following misc items capacities of 125 KVA to 160 KVA DG Sets ( DG sets 08 Nos) :-
Fuel filter
Lub Oil filter
By pass oil filter
CR filter plate & 'O' ring
Air filter (inner and outer)
V belt
Radiator fan belt
Turbocharger Hose pipe
Emergency stop switch
Supply and fix in repairs replacement of following misc items capacities of 62.5 KVA to 100 KVA DG Sets (05 Nos) :-
Fuel filter
Lub Oil filter
By pass oil filter
CR filter plate & 'O' ring
Air filter (inner and outer)
V belt
Radiator fan belt
Battery connectors with brass end
Supply and fix in repairs replacement of following misc items capacities of 20 KVA to 50 KVA DG Sets (05 Nos) :-
Fuel filter
Lub Oil filter
By pass oil filter
CR filter plate & 'O' ring
Air filter (inner and outer)
Supply and fix Battery suitable for 12 Volts DC supply 180 AH, complete all as specified & directed by EIC Make AMARON/Exide or equivalent
Supply and fix Battery suitable for 12 Volts DC supply 120 AH, complete all as specified & directed by EIC Make AMARON/Exide or equivalent
M&L for dismantling existing unserviceable exhaust pipe of 100/125 KVA/160 KVA /250 KVA DG set and supply and fix new exhaust pipe of exiting model complete including lapping asbestos rope making good all disturbed surface area to match the surrounding
Material and labour for manual scraping of old painted surface and providing spray painting with two coat of synthetic enamelled paint of aquostic enclosure of following size of DG Sets complete all as specified and directed by Engr-in-charge.
Supply and fix and topping up of lubricant oil of various capacity of DG sets at various location under GE Navy Porbandar complete all as specified and directed by Engr-in-charge.
Supply and fix and topping up of Coolant of various capacity of DG sets at various location under GE Navy Porbandar complete all as specified and directed by Engr-in-charge.
M & L for servicing Fuel injection pump of 100 to160 KVA DG Set by striping off complete and cleaning each part in volatile liquid cleaner / petrol removing scales, cleaning, injector, spray nozzle including replacement of wornout parts such as injector heads including re-calibration from authorised service centre for smooth functioning etc. including testing and refixing in the same position all as specified and as directed by Engineer-In-Charge.
Complete repair overhauling ,servicing of radiator ,cooling fan assembly , belts, bearings, cleaning of fins, leakage detection by high pressure fluid method and repair leakages in radiators incl replacement of complete repair kit required for the following capacities :-
S&F Battery Charger 230 V, AC Input and 24 Volt DC out put suitable for AMF panel as per exising make complete all as specified and directed by Engineer-In-Charge.
Supply and fix in replacement of defective automatic voltage rectifier of 30/ 75/125/160 KVA DG set complete all as directed.
M & L for complete servicing and rewinding of of Alternator of DG set upto 160 kVA capacity complete testing at site , Shifting to Workshop dismantling and refixing after rewinding and testing all as specified and as directed
S & F in repair/replacement of Power contactor current rating upto 225A fixed complete all as specified and as directed by the Engineer-In-Charge. Make L&T/C&S or equivalent
M & L for complete servicing of control panel of DG sets of any capacity , checking working of Display, Internal Circuits, ON-OFF system , Fuel indicators complete all as specified and as directed
Repair/Replacement of DG set control panel of 20-75 KVA capacity all as per standard OEM specification including removing unserviceable panel all as specified and as directed.
Repair/Replacement of DG set control panel upto 100-160 KVA capacity capacity all as per standard OEM specification including removing unserviceable panel all as specified and as directed.
Repair / Replacement of manual Change over switch panel of capacity 200 Amps manually operated for 160 KVA DG Set with enclosure SS of 1.6 Guage thickness all as specified and directed Make :L&T or equivalent
Repair / Replacement of manual Change over switch panel of capacity 400 Amps manually operated for upto 250 KVA DG Set with enclosure SS of 1.6 Guage thickness all as specified and directed Make :L&T or equivalent
Servicing of Fire fighting pumpsets electric driven including disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out the pump set from base after opening nuts/bolts, transporting from site to workshop, dismantling pump, removing worn out impeller, ball bearing, gaskets, assembling the pump with replacement of pulley key, gland packing rope, greasing, transporting back to site and fixing on the existing foundation, connecting the electric connection of motor and testing complete to entire satisfaction of Engr-in-charge for the following capacity. (Note :- Major spare parts shall be measured and paid separately, minor spares deemed to in rate quoted, spares like pump shaft, impeller and bearing only will be measured and paid separately under relevant items.
Fire pump set of capacity 80 HP at INS SP & NAE (02 Nos)
Jocky pump set of capacity 15 HP at INS SP & NAE (02 Nos)
Mono block pump set of 10 HP at NSB Blgs(12 Nos) and Nofra Bldg (06 Nos)
Repair and maintenance of of Diesel driven fire pump set, 90 HP horizontal end suction, centrifugal type with CI casing , stainless steel impeller and stainless steel shaft mounted on heavy duty bearings suitable for continuous operation of 440 V , 3 phase, 50 Hz AC supply 70 m Head. 2280 LPM discharge, disassemble and check machine assembly , Clean up the carbon deposits in the combustion chamber,exhaust pipe and muffler, Measure the quantum of wear and tear in the cylinder and change the piston ring and cylinder liner, Check the concurrence between the connecting rod bearing and the crankshaft main bearing, replace the bearing, check the axial concurrence of the camshaft and crankshaft, and acclimate , Check the miserliness of the stopcock seat and grind, Clean the cylinder block, oil painting visage and oil painting strainer, Clean the dirt on the heat exchanger and machine water tank, and check the function of the thermostat. ,Remove the pump, clean and change the oil painting; remove the dirt, Perform a pressure test of 1.5 times the rated outlet pressure of the channel affair system, complete paint the machine assembly, complete all as specified and directed.
Routine maintenance and testing of fire fighting system including fire pump and Hydrant system complete by attending fault testing of system, checking of system etc, including replacement of unserviceable component including preventive Maintanence by replacing parts other than mentioned in relevent item of this sch also for fire fighting system installed at Senior Sailor Block ( S1-S7 Building total 07 Nos), Junior Sailor Block ( J1-J5 Building total 05 Nos), at NOFRA (P-120 to P-122, total 03 Nos Building ) , INS SP, NAE serving of each floor of bldgs comprising following: (a) All cable connectors from main control panel to Zonal fire panel. (b) Pumpset Connection checking and 3 phase connection including minor maintainace in connections. (c) Complete oiling/ Greasing in bearing, couplers, fans. (d) Checking of all inlet outlet valves including routine serviceaing of valves and gland packing changing. (e) Making pumpset on and run pumpset for full capacity for at least 15 min. and checking hydrant system at each floor. all Minor maintainace part deemed to be included in rate. The Parts of higher cost measured and paid seperately. ( Total High rise Bldgs - 15 nos , INS SP -01 , NAE -03 Nos = 19 x 04 Job = 76 Job Note :All Routine maintenance/testing shall be done through Specialist Fire fighting agency.
Routine maintenance and Testing and commissioning “FIRE ALARM CONTROL PANEL” system consisting of multi sensor detector, hooter, siren , manual call point, control panel complete in repairs including wiring and programming in bldgs ( Total High rise Bldgs - 15 nos , INS SP -01 , NAE -03 Nos = 19 x 04 Job = 76 Job) complete with the following: (a) Manual call point with electronic hooter (one in each floor) (b) Factory made vermin proof air tight zone control panel board made out of 16 SWG CRCA sheet enclosure 100mm x 100mm surface type duly powder coated (Red colour) (with arrangement comprising with annunciation system on each floor, indicating (16 zones) 12/24 VDC stand by power supply with trickle boost charger with auto charge over device, panel having test / fault / failure control and indication /annunciation PCB, sound indicator, Fire Smoke detector for each zone complete. Note: Complete system shall be Tested through specialist Fire fighting agency.
Servicing and reparing of unserviceable parts of Fire fighting terrace pump control panel indoor type 2.00 mm thick CRCA sheet having 40 Amps incoming MCCB and 10 HP starter with MCB TP 32 Amps as outgoing aceesories. including disconnecting the electric connection from motor terminal box including insulating the ends of the cable, taking out after opening nuts/bolts, transporting from site to workshop, serviceacing transporting back to site and fixing on the existing position connecting the electric connection of motor and testing complete to entire satisfaction of Engr-in-charge for the following capacity. (Note :- Major spare parts shall be measured and paid separately, minor spares deemed to in rate quoted, spares like pump shaft, impeller and bearing only will be measured and paid separately under relevant items.
Material and labour for cleaning of underground fire pump house sump by draining out the water after pumping by arranging de-watering pumps or by manual operation and wash the walls & bottom surface by high pressure spray with rotary water jet pumps and removing the sludge and foreign matters complete by and socking out the fixing with high pressure wet vacuum pumps scrubbing the wall and cleaning the entire sump including disinfectioning the tanks with spray of chemical approach by concerned authorities complete all as directed by the Engineer-in-Charge
Supply and fix in repair/replacement of manual call point ressetable type duly painted in red colour paint fitted with front glass (to be broken in case of fire) complete with hammer and test key to check the response with out breaking the glass with LED indicator all as specified . Make : Appolo/Agni Surksha
Supply and fix in repair/replacement electronic hooters complete all as specified and as directed by Engineer-in-Charge. Make : Appolo/Agni Surksha
Supply,fixing,in repair/replacement Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360. Make : Agni or eqivalent
Supply and fix in repair 63 mm dia 15 meter long RRL (Reinforced Rubber Lined) Fire hose with jacket 100% synthetic yarn fabric reinforced conforming to IS 8423:1994 complete with male and female coupling conforming to IS 903 complete all as directed by Engr-in-charge. Make:- NewAge / Essel / Swati / Safex/Agni
Supply and fix in repair 63 mm dia 30 meter long RRL (Reinforced Rubber Lined) Fire hose with jacket 100% synthetic yarn fabric reinforced conforming to IS 8423:1994 complete with male and female coupling conforming to IS 903 complete all as directed by Engr-in-charge. Make:- NewAge / Essel / Swati / Safex/Agni
Repair replacement rubber hose reel including reel drum of swivelling type of 20 mm size of 30 mtr length including nozzle complete all as specified and directed at site by Engineer-in-Charge. Make:- NewAge / Essel / Swati / Safex/Agni
Repair/replacement of “FIRE ALARM CONTROL PANEL” system complete in repairs including wiring in high rise building upto G + 08 stories complete with the following: (a) Manual call point with electronic hooter (one in each floor) (b) Factory made vermin proof air tight zone control panel board made out of 16 SWG CRCA sheet enclosure 100mm x 100mm surface type duly powder coated (Red colour) (with arrangement comprising with annunciation system on each floor, indicating (16 zones) 12/24 VDC stand by power supply with trickle boost charger with auto charge over device, panel having test / fault / failure control and indication /annunciation PCB, sound indicator for each zone complete. Make : Agni or equivalent
Repair replacement for single out let fire hydrant with gun metal body having 63mm dia out let with valve and instantanious type female coupling with cap on outlet suitable for fixing on 80/100/150mm flange including taking down of the old fire hydrant complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repairs internal hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800mm X 600nun X 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside and concealed in wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend " FIRE HOSE" painted prominently in graphic style and all as specified and directed
Supply and Fix in repairs outside hose box cabinet made out of 18 gauge MH sheet of size as per site reqirement but not less than 800mm X 600nun X 250mm with double leafed glazed shutters (glazed with 4mm thick transperent fiber sheet) and door frame made out of 16 guage MS sheet painted fire red outside and brilliant white inside and concealed in wall complete all as specied and directed for housing two number RRL hose each 15m long, one number branch pipe with nozzle , first aid hose and single outlet hydrant valve etc and must have the legend " FIRE HOSE" painted prominently in graphic style and all as specified and directed
Supply & fix fire hydrant operating GI wheel suitable for operating 63/80 mm dia outlet valve all as specified and directed by Engineer-in-Charge.
Supply & fix brass blank cap and hose lock with 15 cm MS chain suitable for single/double fire hydrant including taking down the old cap & lock complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair steel lock pin (lugs) for 65/80 mm dia complete all as specified and directed by Engineer-in-Charge.
Repair replacement blank MS flange of size 100 mm made out of MS 12 mm thick including flange joint complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair brass nozzle suitable for 20 mm dia rubber hose pipe complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs brass hydrant valve nut as per existing size complete all as specified and directed by Engineer-in-Charge.
Repair replacement PVC blank cap of hydrants with GI chain complete all as specified and directed by Engineer-in-Charge.
Servicing complete to hose reel drum by applying greasing, oiling etc for making free rotation complete and painting two coats of synthetic enamel red paint over a coat of metalic primer complete all as directed.
Servicing complete to twin out let/single out let hydrant by applying greasing, oiling etc for making free rotation complete and painting two coats of synthetic enamel red paint over a coat of metalic primer complete all as directed.
Servicing complete to Sluice valve of size 80/100/150 mm dia (in position) in existing position at site by applying greasing, oiling , packing , Checking threaded rod, etc for making free rotation complete and painting two coats of synthetic enamel black paint over a coat of metalic primer complete all as directed.
Material and labour for repair/replacement of cast iron sluice valve with flanged end class PN 1.6 including all joints with rubber gasket, bolts, and nuts washer complete all as specified of sizes :- Make : Kirloskar/Zoloto/Kartar
150 mm bore
100 mm bore
80 mm bore
Supply and fix in repairs Foot valve cast iron body both ends flanged suitable for 100 mm bore CI pipe connection all as specified and directed. Make -Kirloskar/Kartar/Zoloto/AUDICO
Material and Labour for painting of fire hydrant/fire hose box of any size with one coat of red oxide and two coats of synthetic enamelled paint of FIRE RED colour complete with all fittings etc all as specified and directed by Engineer-in-charge.
Taking down old GI tubing 80 mm bore heavy class fixed on wall etc including making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Repair replacement GI tubing 80 mm bore heavy Class complete with fittings like; Tee, bends, flanged etc to be fixed on wall or laid in trenches complete with drilling, welding, bending shaping etc all as specified and directed by Engineer-in-Chage.
Taking down old GI tubing 100 mm bore heavy class fixed on wall or laid in trenches including making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Repair replacement GI tubing 100 mm bore heavy Class complete with flange type fittings like; Tee, bends, flanged etc to be fixed on wall or laid in trenches complete with drilling, welding, bending shaping etc all as specified and directed by Engineer-in-charge.
Material and labour for painting in existing position at site of GI/ MS pipe of size 80/100/150 mm dia, not exceeding 60 cm girth (in position), with one coat of red oxide and two coats of synthetic enamelled paint of FIRE RED colour complete with all fittings etc all as specified and directed by Engineer-in-Charge.
M&L for renewal of valve pit of size up to 80 cm x 80 cm x 80 cm (internal diamension), stone / brick construction including all necessary excavation and earth work in any type of soil, returning, filling in disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, PCC in foundation for mix (1:2:4) type D2 brick mansonary in cement mortar (1:4) rendering 12 mm duck in cement mortar (1:4) internally ,finished even and fair and polishing flush externally as the work proceeds in the same mortor. Mild steel angle iron 40 x 40 x 6 mm frame MS sheet cover 3.15 mm thick with handle and locking arrangement, painting all exposed MS work with two coats of synthetic enamel paint of the that as approved by the Engineer - in - charge over a coat of red oxide primer and painting all the MS embeded in PCC with two coats of black bitumenous paint complete all as specified.
Repair / Replacement of Contactor for starter for 10 HP pumpset tarrece fire fighting. Make L&T Model MNX-12 or equivalent in other make
Repair / Replacement of single phase preventor 240 V for starter of 10 HP at fire fighting panel Make : Minilec or equivalent
Supply and fix in repair Pressure gauge of 4" dial 0-14 kgs rating with ball valve including taking up / down old unserviceable pressure gauge from any position and any addition / alteration for fixing required complete all as specified and as directed. Make: FIEBIG/ H. GURU/ BAKER MERCER/ DANFOSS
Supply and fix in repair/replacement Fire brigade inlet connection 2way complete all as specified and as directed
Repair / Replacement indicating Lamp (Red,Green,orange or blue) for indicating ON,OFF,TRIP all as specified and as directed. Make : L&T or equivalent
Repair / Replacement digital voltmeter for fire fighting pumpset panel all as specified and as directed.Make : Schneider or eqivalent
Repair replacement digital Ammeter for fire fighting pumpset panel all as specified and as directed.Make : Schneider or eqivalent
Srapping and Painting, filling cavities of rusted parts and two coat exposed body surface with synthetic/Oil paint over one coat of red oxide paint 10 HP Pumpsets of any capacity. Colour of pumpset shall be Blue all as specified and directed by Engr-in-charge.
Srapping and Painting, filling cavities of rusted parts and two coat exposed body surface with synthetic/Oil paint over one coat of red oxide paint Fire fighting panel of any capacity. all as specified and directed by Engr-in-charge.
Repair / Replacement PVC insulated, heavy duty electric cable with copper conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core from fire fighting panel to Pumpset all as specified and directed.Make : Polycab or equivalent
Repair / Replacement of PVC insulated PVC sheathed cable galvanized steel strip or wire armored, electronic control cables (Heavy Duty) with stranded Copper conductor of size 2.5 sq mm 4 core 1100 Volts grade.
Repair / Replacement of CI Non return valve of 100 mm Butterfly size all as specified and directed. Make Balaji or equivalent
Comprehensive maintenance of electrically operated travelling (EOT) crane of 02 Ton capacity (02 Nos), Span 10 meter approx, Bay length 35 meter approx, height of lift 7 meter approx, floor operated through pendent puch button, comprising of hoist motor, micro motor, long travel, cross travel motor, gear box, control panel and other connected accessories installed at Technical Complex INS Sardar Patel Notes :- (a) Inspection checking decarbonising & tightning of electrical connection in total system including replacement of thimbles etc. (b) Inspection & checking of gear motor, setting, greasing, Oiling and tightning the same as per their capacity. (c) Inspection & setting of voltage system including replacement of fused indicating lamp etc. (d) Spares for EOT crane will be measured and paid seperately. (e) Contractor will carry out comprehensive maintenance once in a month for the duration of contract period and maintain the record of the same as per the performa and as directed by Engh-in-charge (f) Any breakdown during concurrency of contract shall be repaired by contractor within 48 hrs without any extra cost
Comprehensive maintenance of electrically operated travelling (EOT) crane of 05 Ton capacity, Span 44 meter approx, Bay length 35 meter approx, height of lift 6 meter approx, floor operated through pendent puch button, comprising of hoist motor, micro motor, long travel, cross travel motor, gear box, control panel and other connected accessories installed at Hanger 314 NAE (01 No) Notes :- (a) Inspection checking decarbonising & tightning of electrical connection in total system including replacement of thimbles etc. (b) Inspection & checking of gear motor, setting, greasing, Oiling and tightning the same as per their capacity. (c) Inspection & setting of voltage system including replacement of fused indicating lamp etc. (d) Spares for EOT crane will be measured and paid seperately. (e) Contractor will carry out comprehensive maintenance once in a month for the duration of contract period and maintain the record of the same as per the performa and as directed by Engh-in-charge (f) Any breakdown during concurrency of contract shall be repaired by contractor within 48 hrs without any extra cost
Supply & fixing in repair/replacement Pendant Push button control suitable for existing crane complete all as specified and directed by Engr-in-Charge.
Material for painting of EOT crane upto 05 ton capacity completely with two coats of golden yellow paint including preparation of existing surface by scrapping detorioted paint etc. complete all as directed by Engr-in-charge.
Supply and fixing in repair/replacement limit switch assembly for EOT crane upto 05 ton capacity all as per existing at site complete all as specified and directed.
Supply and fixing in repair/replacement of cabling for fire detection and alarm system with 2 core annealed tinned copper conductor PVC sheathed, flexible, 2 core x 1.5 sq mm armoured cable as per specifications complete all as specified and as directed.Repair replacement 1.5 sqmm 2 core flexible wire for fire alarm system drawn in PVC conduit all as specified and directed Make : Polycab/Finolex or equivalent
M&L for fire point made of MS angle, MS sheet as suitable size and including fixing arrangement. The fire point shall be consists with the following items to be provided with no extra cost: (i) Hook - 03 Nos (ii) Fire bucket with handle - 01 Nos
Material and labour for rewinding the electric motor of capacity 30 HP capacity at swimming pool filteration plant, disconnecting the electric connection of motors, earth connections, decoupling motor and pump, removing foundation nuts/bolts and removing the motors from its existing position to workshop (Note : following work are to be deemed in rate quoted). (a) Removing the split case/body cover of motor, separate stator/rotor and cutting the complete burnt/defective copper winding. (b) Cleaning the stator body complete by rubbing sand paper remove all carbons. (c) Insert insulating materials such as insulating paper sleeves. (d) Rewinding the stator with existing size of super enameled copper winding, varnishing and heating up at desired temp. For achieve the particular Ohm resistance. (e) Clean the rotor and assembling in motor. (f) Connection/coupling the motor with pump, connect all electric/earth connection foundation nuts/bolts at its original position and testing on load complete all as specified and directed.
Maint/Cleaning of Pump house stations inside and out side area and removing of creepers and vegetation raised along with fire fighting supply installation including surface dressing around the E/M installation from out side fencing and removing the all waste material from site and Chemical spray inside and out side area of Sub station. Note:- T & P will be arreanged by contractor
Supply and fixing in replacement First aid box PVC body with complete kit/accessories wall mounting type all as specified and directed.
Repair replacement of unserviceable /burnt starter of fountain motor including replacement of defective capacitor,MCBs, Enclosure etc. at Sandhika
Repair replacement of XLPE insulated armoured and pvc sheated heavy duty electric cable , aluminium conductor 1100 volt 3-1/2 core 120 Sqmm cross sectional area grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts including testing complete for following size note- rate is inclusive of cable gland & cable lugs Make- Havells/FINOLEX/CCI/Polycab/KEI
Repair replacement of XLPE insulated armoured and pvc sheated heavy duty electric cable , aluminium conductor 1100 volt 3-1/2 core 70 Sqmm cross sectional area grade as per IS 7098 (Part-1) 1988 with latest amendment laid in tranches passing through pipes /ducts including testing complete for following size note- rate is inclusive of cable gland & cable lugs Make- Havells/FINOLEX/CCI/Polycab/KEI
Excavation in trenches in hard /dense soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Repair and replacement of laying of Double Walled Corrugated (DWC) HDPE pipe 90/75 mm outer/inner dia of following size of conforming to IS 16205 Part -24 including necessary bends,coupling ,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge Make:-ASTRAL TELEREX /eqivalent as approved by GE
GI Tubing light grade 80mm for cable protection, laid under plinths/floors /roads /culverts or fixed on walls or concealed in walls or along the steel poles by means of M.S.F.I clamps with necessary bolts nuts washers etc complete all as specified.
M & L for Cutting the existing PCC floor/road/foot path not exeeding 15cm width,30 cm depth for laying of UG cable/protection of pipe all as directed.
M & L for PCC type B1,1:2:4 using 20 mm graded stone aggregate all as specified and directed.
M & L in replacement of Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to galvanized iron strip 32 x 6 mm by means of GI bolts nuts, check nuts and washers etc all as shown in electrical plate No. 3 of SSR part 01 1996 including earth work PCC pit with cover, funnel with watering pipe, wire mesh and GI protection pipe light grade all as specified and directed.
Veer High Tech Solution (BID ID -3477528)
Shree Ayyappa Engineering (BID ID -3477998)
shubham construction (BID ID -3478442)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_825956.xls
BOQ • 9.49 MB
Tenderdocus.pdf
Tender Documents • 0.93 MB
Download all tender documents and submit your bid