ASSISTANT EXECUTIVE ENGINEER
OFFICE OF THE EXECUTIVE ENGINEER , LSGD DIVISION, PALAKKAD
Electrification to the new class rooms attached to GHS Anakkara (Proj. 484/21)
2020_LSGD_388639_1
217/E/20-21
Open Tender
Electrical Works
Item Rate
180 days
LSGD DIVISION
PLEASE REFER TENDER DOCUMENTS
4 documents required · 4 mandatory
₹700
Yes
online
₹7,800
Yes
4 Dec 2021
30 Sept 2020
20 Oct 2020
30 Sept 2020
16 Oct 2020
30 Sept 2020
90 days
Amount
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties,tie mounts etc.as required(RoHS compliant modular accessories)
Single Control light point with 6A, plate ceiling rose - Short point (90.2.1.1 )
Single Control light point without ceiling rose - Short point (90.2.1.3 )
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point (90.2.1.4)
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points. (90.2.1.6)
Independent Plug - Short Point ( 90.2.1.7 )
Supply & installation of light fittings on flat iron bracket Supply,conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.
1200 mm 1X20W LED Lamp with box type fixture (90.3.22.3)
Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
1200 mm 1X20W LED Lamp with box type fixture (90.3.20.3)
Supplying and providing extra H.G/ ISI marked, steel conduit down rod of 19/20 mm dia 2 x 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required. (90.3.10)
Supply, conveyance, installation, testing and commissioning of pre-wired light fitting of LED Street light fitting IP 65,pressure die-cast housing with induvidual LEDs with modular secondary optics 25watts with driver and including all necessary all accessories etc in the existing GI pipe and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required - BAJAJ make BRLEP25W LED/Endura Citylite Platinum 25 LED/Osram strada plus/ phillips make.(od20530/2019_2020)
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps.(90.3.18.1)
Supply,conveyance,installation,testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
1200mm sweep - 5star rated ceiling fan complete with 300mm down rod,canopies, shackeles etc. working on 230V/240V single phase A/C (90.4.5.2)
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.(90.4.1)
Supply and providing every additional length of down rod of suitable size heavy gauge GI/WI pipe with 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming in relevant ISS or with original wiring extended including painting as required.(od31652/ 2018_ 2019)
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required. 20 mm dia light gauge.(od98698/ 2018_2019)
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required. 25 mm dia light gauge. (od15220/2019_2020)
Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
1.50 sq.mm 2 Run (1.17.2)
1.50 sq.mm 4 Run (1.17.4)
4.00 sq.mm 2 Run (1.17.20)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) (1.27.5)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm) (1.27.2)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet.(1.24.5)
Do - Do - 15/16 amp switch. (1.24.3)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc.as required.3 pin 5/6 amp socket outlet. (1.24.4)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc.as required.5/6 amp switch. (1.24.1)
Supplying and fixing DP enclosure for independent mounting of MCB DB sheet steel phosphatised, painted, dust and vermin proof enclosure on surface/recess complete with connections,testing and commissioning etc.as required. (2.16)
Supplying and fixing 6A to 32A ratings DP MCB "C" curve, 10 kA breaking capacity miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections,testing and commissioning etc.as required. (2.10.3)
S&F 4 Pole enclosure MCB DB sheet steel phosphatised , painted, dust and vermin proof on surface/ recess etc. as required. (od121450/2019_2020) .
S&F 5A to 32A rating,415 volts, "C" curve, MCB suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. TPN MCB (2.10.5)
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board,240v,on surface/ recess,complete with tinned copper bus bar, neutral bus bar,earth bar,din bar,interconnections,powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator,12 way, Double door.(2.3.3)
Supply and installation of sheet steel, phosphatised and painted,dust and vermin proof enclosure of MCB DB including copper /brass bus bar,neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc.as required. 4way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) (90.11.1.14)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Do - 63 amps 4 pole isolator. (2.13.2)
Do - 40 amps 2 pole isolator (2.12.1 )
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 amps,4 Pole,30mA RCCB. (2.15.3)
25A rating, 2 pole RCCB, 30 rnA (2.14.1)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
6 A. to 32 A. ratings , SP MCB, "C" curve,10 kA breaking capacity. (2.10.1 )
Do - 40 A to 63 A TP MCB, "C" curve,10 kA breaking capacity. (Data )
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2 metre long etc. with charcoal/coke and salt as required.(od15347/2019_2020)
Providing and fixing 25mmx3mm G.I strip earth lead from the test joint to the earth plate. (od15349/2019_2020)
Supply and drawing bare earthing conductors of the following sizes along with wiring / cables and giving connection as required. 2.00mm copper conductor (14 SWG) (od21804/2019_2020)
Do - 3.15 mm copper conductor (10 SWG) (od21806/ 2019_2020)
Do - 2.65mm copper conductor (12 SWG) (od21802/2019 _2020)
Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil) 3.15mm copper conductor.(10SWG) (od21872/2019_2020)
Suplying,threading,laying and jointing of 15mm B class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads.(od21874/ 2019_2020)
Supply of superior quality 2.00mm (14SWG) copper earth socket and including crimping etc.as required. (od21882/2019_2020)
Do - 3.15mm copper earth socket and including crimping etc. as required. (od21884/2019_2020)
Supply and providing12x3mm brass nut and bolt etc.as required.(od21888/2019_2020)
25 x 3 mm brass bolt & nut. (od21886/2019_2020)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable,1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages,colour washing etc.as required.
Do - 4 core 16 sq mm with factory made clamp - Do - - Do - (90.12.7.41)
Do - 2 core 6 sq mm with factory made clamp - Do - - Do - (90.12.7.2)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Do - 4 X 16 sq. mm (28mm) (9.1.33)
Do - 2 X 6 sq. mm (19mm) (9.1.1)
Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench.
50/38 mm or nearest size. ( 90.12.9.2)
Supply & installation of dust and vermin proof, 3 Phase Sintex Meter Board( GS-MB- 5628 (515 x 240 x145) including P/F 3 Nos 63 A HRC Fuse Base with HRC Fuse link ,63 A neutal link and to fix KSEB meters, etc as required including fixing it on wall, making good the damages colour washing etc. as required.(od15345/2019_ 2020)
Supply,fabrication,conveyance and fixing the following sizes of B class GI pipe bent to shape/cut and welded to shape and fixing the same to wall/parapet using clamps as noted along with each size,painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer,making good the damages,colour washing etc.as required.32mm dia with HG company faricated clamps.(90.3.18.2)
Supply and providing M8 anchor bolt hook in wall / parapet for binding support for service main.(od49117/2018_2019)
Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with 200mm Plastic shade and 7 W LED lamp and giving connection etc as required. (od15215/2019_2020)
Rafeeq P V
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_552532.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .