Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹20.8 L
EMD Value
₹21,000
Closing Date
5 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Executive Engineer Ukai Division No.1, Ukai
Providing and Erecting to LED Street Light Fittings for the Down Stream Area at Madhuban Dam
367910
E Tender Notice No.27 of 2026-27
Open
Electrical - All
Works
Tapi
10 documents required · 10 mandatory
₹900
Executive Engineer Ukai Division No.1,Ukai
₹21,000
21 Nov 2026
21 Nov 2026
21 Nov 2026
5 Dec 2026
21 Nov 2026
120 days
Name of work:- Providing and Erecting to LED Street Light Fittings for the Down Stream Area at Madhuban Dam
Sr.No Qty Item rate rate in words Per Amount
Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv
1 grade ISI marked copper wires of following size to be erected as directed.
(e) 1.50 Sq.mm 3 core round PVC sheathed
Rupees FiftyEight
Paise FiftyEight Only
Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free High pressure
die cast aluminum housing with smooth finish powder coated and heat
sink extruded aluminium with diffuser and Polycarbonate optics/ lenses,
with toughened glass with company mark/name engraved or embossed
160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must
have 440VAC line supply with over-voltage protection.
(iii) Above 60 to 90 watts
94 5080.30 Thousand Eighty Ea
Paise Thirty Only
providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Rupees One Hundred
3 94 Mark (B) cat-(III) 123.22 TwentyThree Paise Ea
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size of cables
(A) 4 core 16 Sq. mm
Rupees One Hundred
1900.00 184.83 EightyFour Paise Mtr
EightyThree Only
(B) 4 core 25 Sq. mm
Rupees Two Hundred
30.00 229.27 TwentyNine Paise Mtr
TwentySeven Only
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or
required depth for laying any size of cable or locating the fault all over the Rupees SeventyFour
5 1810.00 run and back filling the same and making the surface as normal ground. 74.74 Paise SeventyFour Mtr
Providing & laying approved make Double walled corrugated pipes
(DWC) of polyethylene(conforming to IS 14930 II )with necessary
connecting accessories of same material at required depth in existing
trench for laying of cable. below ground / road surface for enclosing
(A)50 mm outer dia
Rupees SixtyTwo
Paise SixtyTwo Only
Solder less crimping type Aluminium lugs conforming to IS suitable for
cable of following size evenly crimped with high pressure tool & connected
7 to switchgear terminals with brass/cadmium plated nut bolts in an
approved manner.
Rupees Fifteen Paise
Supplying and erecting approved make Octagonal pole made from HR
sheet steel. The pole should be made as per IS. and shall be coated with
hot dip galvanizing as per IS 2629/2633/4759, suitable suspend local wind
speed with integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting,
8 stud type terminal and arrangement for cable termination to be erected
With Suitable foundation (Included) as per details given by manufacturer
considering site requirement.
(D) 6 Mtr. Long 70 mm Top X 135 mm bottom dia, 3 mm thickness with Rupees Nine
200mmX200mmX12mm base plate, 4-M20 Bolts and 600mm long with Thousand Eleven
94 necessary G.I. J Bolts .Approx Pole weight 59 kg 9011.22 Nos.
Paise TwentyTwo
Providing and erecting street light pole bracket comprising main B Class
GI pipe of 4.2 cm/require outside dia. complete with suitable B Class G.I
sleeve tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. /
require size pole top having sufficient fasteners for fixing the brackets and
having spread of 1 mtr. length with suitable rise as per site condition &
suitable welded stiffener reducer and nipple with check nut complete
painted with one coat of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of arms.
[A] Single Arm bracket 1 Mtr
Rupees Six Hundred
94 614.08 Fourteen Paise Eight Nos.
Supplying & erecting approved make IP 55 grade Company fabricated
Timer Panel of following capacity for switch On-Off street lights on time
scheduling basis made from 16G CRCA sheet duly epoxy power painted
inside and outside with hinged doors and locking arrangement consisting
10 of suitable size of 4 Pole MCB and 4 pole contactor (cat-III)with analog
time switch, auto manual switch of same make and suitable input and
output Bakelite terminals and with door earthing approved by Engineer in
Rupees Seventeen
1 17059.91 Thousand FiftyNine Ea.
Paise NinetyOne Only
Supplying & erecting earth pit of minimum bore dia.150mm size approved
make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS
3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe
dia of 50mm having 80-200 Micron galvanising, Inner pipe dia of 25 mm
having 200-250 Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive compound with
high charge dissipation suitable for following type of applications with
chamber and heavy duty cover. (A)(approved make OEM has to submit
test certificate including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to ensure the
value of earthing resistane mentioned in test Certificate) & having back
11 filling compound of (B) Inner chemical (CCM Compound)- Resistivity:-
ohm / meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing
compound should be capable to retain moisture for long time Necessary
test report must be submitted by Agency.
(a) For Electrical Installation up to 440V in normal soil
4 Length of pipe - 1 Mtr 4591.46 Ea
Hundred NinetyOne
Back filling compound - 1 Nos Bag of 15 Kg.
Paise FourtySix Only
Providing and erecting HOT deep Galvanised iron strip/wire 4.064mm to
1.626mm. Rupees SeventySeven
12 10 77.77 Paise SeventySeven Kg.
I/We am/are willing to carry out the work at ……………………………………………% above/below percent (shouldbe written in figured and words)
of the estimated rates mentioned above. Amount of my/our tender works out as under.
Estimated amount Estimated amount
Put to tender Rs______________ Put to tender Rs______________
Deduct : ___________ % Above RS__________ Deduct : ___________ % Below RS__________
*(Please strike out whitchever is not applicable).
Note 1 – All work shall be carried out as per public works department handbook and other specification of Division ot as directed.
Note 2 – All the columns is schedule should be filled in ink and the total of the entries in the last column should be struck by the contractor
under his signature.
Note 3 – Rates quoted include clearance of site (prior commencement of work and at its close ) in all respects and hold good for work under
all conditions, site, moisture,weather etc.
Note 4 – To be continued on additional sheets, if found necessary.
Note 5 - The rates quoted by the Contractor must be inclusive of all taxes prevailing on due date of bid submission except GST. However, any
subsequent changes in the tax structure by Government after due date of bid submission will be compensated (+/-) on availability or submission
of actual documentation. Contractor will have to intimate Engineer regarding changes occurred in the tax structure after bid submission. If the
contractor fails to provide such information and if any financial obligation may arise due to change in tax structure, same will be recovered from
the contractor. GST will be paid separately on the bills. Hence, it is the responsibility of the contractor to pay the GST to the concerned
Deputy Executive Engineer Executive Engineer
Electrical sub Division Ukai Division No.1
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
FINAL _ SBD street light fittings down streem madhuban .pdf
Sch B Madhuban Street Light.pdf
2.0 Special condion Electric (5).pdf
5.0 Approved make list 2013 2014 Part 1.pdf
6.0 Approved make list 2013 2014 Part 2.pdf
E-Tender Notice No.27 of 2026-27.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .