Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance BUS STAND ROAD BARARA AMBALA | BARARA | AMBALA | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance A 18 SECTOR 136 NOIDA UTTAR PRADESH 201304 | NOIDA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201304 | Admitted-Finance |
| 4 | Not Admitted-PreQual/Technical 3 3 2 BELLANDUR GATE SARJAPUR MAIN ROAD BANGALORE 560103 KARNATAKA | BENGALURU URBAN | KARNATAKA | 560103 | Not Admitted-PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹29.5 L
Closing Date
20 Apr 2021, 5:00 pmClosed
SE/Contracts
HVPNL, Sector-6, Shakti Bhawan, Panchkula
Construction of 66 kV and 132 kV transmission lines in Yamunanagar and Sonepat area
2021_HBC_155298_1
EPC-D-15 PD and C
Open Tender
Electrical Works
450 days
Yamunanagar Sonepat
As per bidding documents
8 documents required · 8 mandatory
₹11,800
₹29.5 L
Yes
2 Aug 2021
5 Jan 2021
28 Apr 2021
5 Jan 2021
20 Apr 2021
5 Jan 2021
Fabrication and supply of tower part with stubs, bolts & nuts, step bolts, U-bolts, hangers, D-shakle etc. of following type of Towers as per KRR design:- 66kV D/C “DA” KRR Design type Tower
+3 mtr. extn. only
+6 mtr. extn. only
66kV D/C “DB” KRR Design type Tower
+6m extn. Only
66kV D/C “DC” KRR Design type Tower
+3m extn. Only
+6m extn. Only
+9m extn. Only
66kV D/C “DD” KRR Design type Tower
+3m extn. Only
+6m extn. Only
+12m extn. Only
+15m extn. Only
Extra cross-arm only (Set of 3)
66KV D/C Gantry
66kV M/C “MA” KRR Design type Tower
66kV M/C “MB” KRR Design type Tower
66kV M/C “MD” KRR Design type Tower
Extra cross-arm only (Set of 3)
220kV D/C “DC” TATA Design type Tower
+18m extn. Only
Supply of earthing of towers:- Pipe Type
Supply of following Tower accessories:- Danger Plate
Number Plate
Phase Plate (set of 3)
Circuit Plate (set of 2)
Bird Guard (Set of 3)
Anti climbing device
Line Material:- Conductor (ACSR Zebra)
AL-59 Conductor (equivalent diameter of 0.2sq inch ACSR)
Earth wire (7/3.15mm)
66KV Anti-Fog type Disc Insulator or Silicon Rubber Polymer Insulator strings:-70 kN
66kV Post Insulator
Hardware Fittings for ACSR Zebra Condutor:- Single ‘I’ Suspension String
Single suspension pilot string
Single Tension string
Double tension string
Hardware Fittings suitable for ACSR Panether Conductor:- Single Tension String
Hardware Fittings of AL-59 Conductor(equivalent diameter of 0.2sq inch ACSR):- Single ‘I’ Suspension String
Single suspension pilot string
Single Tension string
Double tension string
AL-59 Conductor(equivalent diameter of 0.2sq inch ACSR)Accessories:- Mid Span Compression Joint for conductor
ii) Repair sleeves for conductor
iii) Vibration damper for conductor
Conductor & Earth wire Accessories:- Mid Span Compression Joint for ACSR Zebra conductor
Mid Span Compression Joint for earth wire
Repair sleeves for Zebra conductor
Flexible copper Bond
Vibration damper for ACSR Zebra conductor
Vibration damper for earthwire
Earth-wire Tension Clamp
Repair sleeves for earthwire
Earth-wire Suspension clamp
OPGW (24 Fiber) DWSM
Hardware Set for above 24 OPGW Fiber Optic cabling including all cable fitting & accessories except joint box
Joint Box 24 Fiber OPGW to OPGW (as applicable)
Joint Box 24 Fiber OPGW to OFAC (as applicable)
FODP 48F: In door type, rack mounted with FCPC Coupling and pig tails (5mtrs, each) as applicable (220KV S/Stn. Bakana&66KV S/Stn. Sector-16, Jagadhari ends)
Fiber Optic Approach Cable, 24 fiber (DWSM) along with PLB HPE Ducts of suitable size & strength and all accessories (220KV S/Stn. Bakana& 66KV S/Stn. Sector-16, Jagadhari ends)
Wideband Communication equipment and spares Telecom Equipment at 66KV S/Stn. Sector-16, HSVP Jagadhari. SDH Equipment (STM - 16 MADM upto 5 MSP protected directions). Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding (ii) & (iii) below
Optical Interface Cards/SFP:-S16.1 SFP (The quantities will be decided at the time of detailed engineering)
L16.2 SFP (The quantities will be decided at the time of detailed engineering)
S4.1 SFP (The quantities will be decided at the time of detailed engineering)
L4.2 SFP(The quantities will be decided at the time of detailed engineering)
Tributary Cards:- E1 Interface card ( Min. 32 interfaces per card)
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
Equipment Cabinet with DDF and all installation accessories
Network Manager System - Craft Terminal Hardware
Software
VOIP telephone instrument with one common switch(min. 8 port) compatible with SLDC
Integration of the Equipment with existing network
Mandatory Spares Telecom Equipment at 66KV S/Stn. Sector-16, HSVP Jagadhari. SDH Equipment (STM - 16 MADM up to 5 MSP protected directions). Optical Interface Cards/SFP:- S16.1 SFP (The quantities will be decided at the time of detailed engineering)
L16.2 SFP (The quantities will be decided at the time of detailed engineering)
S4.1 SFP (The quantities will be decided at the time of detailed engineering)
L4.2 SFP(The quantities will be decided at the time of detailed engineering)
Tributary Cards:-E1 Interface card ( Min. 32 interfaces per card)
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
Pre Connectorized Optical Patch Cards (10Mtrs.) – Pack of six Patch Cards
DISMANTLEMENT WORK to be included in Erection Part of BOQ Dismantlement of towers/poles and their transportation & proper stacking at any dedicated store of HVPNL. The dismantlement of tower/poles shall also include dismantlement of Stub concrete upto a depth of 1M (one meter) from Natural Ground level, back filling , compaction and clearing the site of debris:- a) H-Pole Structure.
4-Pole Structure
Dismantlement of existing of 0.2sq” ACSR Panther conductor complete with H/W fittings for above portion of line and their transportation proper stacking at any dedicated store of HVPNL.
Dismantlement of existing OPGW/Earthwire complete with H/W fittings for above portion of line and their transportation proper stacking at any dedicated store of HVPNL.
DISMANTLEMENT WORK to be included in Erection Part of BOQ:- Dismantlement of existing of 0.2sq” ACSR conductor complete with H/W fittings, Insulators for above line, their transportation & proper stacking at dedicated store of HVPNL and Erection of Dismantled Insulators for augmentation of lines.
CIVIL WORKS Detailed Survey
Furnishing bore log data
Construction of tower foundations as per HVPNL Drgs & Specs for 0 to 6 M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. 66kV D/C ‘DA’ type tower (KRR Design) classified as - - Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
66kV D/C ‘DB’ type tower (KRR Design) classified as - Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
66kV D/C ‘DC’ type tower (KRR Design) classified as - Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
66kV D/C ‘DD’ type tower (KRR Design) classified as - Dry(Drwaing & Quantity as per Annexure-A)
- Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
Construction of tower foundations as per HVPNL Drgs & Specs for 0 to 9M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. 66kV D/C ‘DC’ type tower (KRR Design) classified as - Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
Construction of tower foundations as per HVPNL Drgs & Specs for 0 to 15M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. 66kV D/C ‘DD’ type tower (KRR Design) classified as - Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
Construction of 66kV D/C gantry foundation as per KRR design (3 No. footings in onet) including excavation, concreting, supply and placement of steel reinformcement and back filling complete in all respect (Drawing & Quantiity as per Annexure-A)
Construction of tower foundations as per HVPNL Drgs & Specs for 0 to 6M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. 66kV M/C ‘MA’ type tower (KRR Design) classified as - Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
66kV M/C ‘MB' type tower (KRR Design) classified as - Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
66kV M/C ‘MD' type tower (KRR Design) classified as - Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
Construction of tower foundations as per HVPNL Drgs & Specs for 0 to 18M extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. 220kV D/C ‘DC' TATA Design type tower - Wet (w/out de-watering)(Drwaing & Quantity as per Annexure-A)
Protection Measure : Brick masonry in 1:4 cement sand mortar including excavation
Earth filling, compaction, leveling etc inside revetments
M-20 (1:1½ :3 mix) concrete for top seal cover, for revetment etc.
Lean concrete (1:4:8)
RCC 1:1.5:3 (M20) including all material, labour, excavation, cutting and placing of steel, centering & shuttering, concreting etc. complete in all respect.
K. Ramachandra Rao Transmission and Projects Pvt. Ltd.
R S INFRAPROJECTS PVT LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid