Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC GRAM RAKSHAWARA THANA KARARI TAH MANJHANPUR KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹45.6 L+₹98,552 (2.21%)Rejected-AOC | L2 | Rejected-AOC Become L2 | |
| 3 | L3₹46.2 L+₹1.6 L (3.54%)Rejected-AOC KALAPAHAR BIMALANAGAR GUWAHATI 781016 DISTT KAMRUP ASSAM | KAMRUP METRO | ASSAM | 781016 | L3 | Rejected-AOC Become L3 | |
| 4 | L4₹47.0 L+₹2.4 L (5.33%)Rejected-AOC | L4 | Rejected-AOC Become L4 |
Tender Value
₹49.7 L
EMD Value
₹99,400
Closing Date
26 Aug 2020, 6:00 pmClosed
GE SOUTH TEZPUR
GE SOUTH TEZPUR MISSION CHARALI
SPECIAL REPAIR TO BLDG NO P-67 AND P-15 (1-4) QTRS OR MD ACCN AT CERTAIN UNIT OF SAA UNDER GE (S) TEZPUR
2020_MES_364937_1
8520
Open Tender
Civil Works
Item Rate
240 days
GE SOUTH TEZPUR
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE SOTH TEZPUR
₹99,400
Yes
22 Oct 2020
29 Jul 2020
28 Aug 2020
29 Jul 2020
26 Aug 2020
12 Aug 2020
Amount
B/R WORKS:- Taking down chowkats or frame with shutters (without taking off shutters from frame) exceeding 1.50 Sqm and not exceeding 4.0 Sqm each including dismantling of PCC bed block for hold fast all as directed.
Taking down chowkats or frame with shutters (without taking off shutters from frame) not exc. 1.5 sq. m each including dismantling of PCC bed block for hold fast all as directed.
Taking down shutters of any description n exc 1sq. m each all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level all as directed.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floors), beams, staircases, landing,chajjas and similar suspended work complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
Taking down cement plaster, of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises all as directed.
Dismantling plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed.
Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.(Note:-(a) All coping’s, corbels, cornices and other projections shall be included with the wall measurements. (b) The rates include taking down walls, etc, with plaster but the measurements will be exclusive of plaster thickness. (c) Honeycomb brickwork and hollow concrete blocks shall be measured solid. (d) Item shall be applied to brickwork and stone masonry other than in roofs and pavings/floors).
Taking down eaves gutters and rainwater pipes (any size or dia or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store complete all as specified and directed. (Note:-Measured overall as fixed along the centre line over fittings and accessories).
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil all as specified and directed.
Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as directed.
Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as directed.
Material and labour for providing Plain Cement Concrete (1:3:6) type C1 using 20mm graded aggregate as in bed block or hold fast all as specified and directed.
Material and labour for Reinforced cement concrete M-25(design mix)in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like all as specified and directed.
Material and labour for brickwork with fly ash/concrete bricks old size bricks built in cement mortar 1:6 , straight or curved on plan exc 6m mean radius, all as specified and directed.(Note:- (a) Fly ash bricks shall be burnt clay flyash building bricks as per IS- 13757.(b) The unit rates for work curved or polygonal on plan include for all extra cutting and extra waste in the body of the work. It shall be measured as mean length of wall. (c)Unit Rates are for bricks of class designation 75 (Kgf/cm2).
Material and labour for formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including supports,overhangs,etc. also splays between floors and beams, etc. for rough finished surfaces of flat concrete complete all as specified and directed.
Supply and fix pressed steel frames of size 125 mm x 60 mmx 1.6 mm with one or more rebates including necessary fixing lugs, hinges, lock strike, plate etc complete all as specified and directed
Supply and fix pressed steel frames of size 105 mm x 60 mmx 1.6 mm with one or more rebates including necessary fixing lugs, hinges, lock strike, plate etc complete all as specified and directed
Supply and fix, factory made not less than 30mm thick, flush shutters, solid core construction, with block board core and plywood face panels both faces decorative laminated type on both sides all as specified and directed.
S & F 30 mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, guage etc (without sash bars) edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part I, section 8,clause 8.24 (a) supplied and fitted to chowkats complete.
S&F solid PVC door frame of size 50mm X 47mm, made out of 5mm plain colour PVC sheet reinfoced with M.S. square tube, supply and fixing in opening as per specification.
S&F factory made solid panel PVC moulded door shutter 28 to 30mm thick (style) with woth particle board core 2 , 6 or 6 raised panel with 2 mm thick moulded PVC sheet on the front face & 2 mm Plain coour PVC sheet on back face supplynig & fixing at site all as specified and direced
S&F 100mm size type B-21 Butt hinges extruded aluminium alloy with galvanised MS sheet hinges pin anodised all as specified and direced.
S&F Aluminium anodised barrel tower bolts of extruded section 150mm long and fixed with screws all as specified and direced..
Supply and fix in repair, floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with 150mm overall length of cover plate complete all as specified and directed.
S & F in repairs 300 mm MS ordinary type pattern springs, including roller and roller plate complete all as specified and directed
Supply and fix, 150 mm extruded aluminum alloy handles, fabricated type, anodized complete all as specified and directed.
Supply and fix, 300 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and directed.
S & F Continuous (piano) hinges,mild steel, bright finish or electrogalvanised of 30mm width of flaps (when open) complete all as specified and directed.
Supply and fix in repair, curtain rods not less than 20mm dia and wall thickness not less than 1.00mm, mild steel, chromium plated with fixing brackets,stops, rollers etc. all as specified and directed.
Supply and fix, stainless steel wire cloth 0.36 nominal dia wire and average width aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Supplied and fixed Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.(Note:-The rates include for fixing and for bracing, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it).
S & F rolled mild steel Fe 410 -W (Gde-E- 250)quality-A in joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) all as specified and directed.(Note:-(a) All rolled steel section (Beams, channels, angles, tees, etc.) shall be of dimensions and weights as indicated and of one length within the usual rolling limits.(b) The unit rates also include for drilling the members for site connections; but site drilling to existing steel work shall be measured and paid separately).
S & F framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 all as specified and directed.(Note:-(a) The unit rates include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete).
S & F hard drawn steel wire fabric (Weight N exc 4kg per square metre) cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia and fixed in reinforcemnt all as specified and directed.(Note:-The rates include for straightening, raking or circular cutting and waste).
S&F false ceiling with powder coated exposed G.I. grid suspension system Everest E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner (3600 mm long, 0.25 mm thick, 38mm height) Cross Tee (1200mm/600mm long, 0.25 mm thick, 27 mm height) and Wall Angle (3000 mm long, 0.4 mm thick, 22 mm height). The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 6 mm dia G.I. wire from purlins/soffit. 4 mm thick High Pressure Steam Cured Everest Non Asbestos Fibre Cement Designer Ceiling Board or equivalent quality having Density>1200 Kg/m3, size 595mm x 595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7&8, should be placed in the Grid module to form a False Ceiling.
S & F anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.(Note:-(a) The unit rates include for provision of PVC protected sheeting and its removal after fixing the frame work. (b) Weight of joining cleat shall be added to main frame. (c) Hinges, shutters and lugs shall be measured and paid for separately).
S & F anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.(Note:-(a) Glass and other filling material in panels shall be measured and paid for separately. (b) Area of opening shall be measured to the nearest 0.5 sq.cm. (c) The unit rates does not include for anodised aluminium hard wares as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames. (d) Fixing of shutters with fittings shall be as per manufacturers instructions).
Material and labour for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strenght of 550 MPA as in roof covering/claddiing to wall, fixed with self tapping screws as specefied all as specefied and directed.
Material and labour for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strenght of 550 MPA as in roof covering /cladding to wall fixed with self tapping screws all as specefied and directed.
M&L fixed in repairs 19/20mm thick block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face,fixed with screws to timber frame-work as specefied all as specefied and directed.
Material and labour for providing 75 mm thick cement concrete (1:3:6) type C1 using 20 mm graded stone aggregate as in plinth protection surfaces finished even and smooth without using extra cement including making construction joint of not less than 15mm width x 75mm depth at interval of 1.5m and filled with bituminous filler comlete all as specified and directed.
Material and labour for Non - skid Ceramic Coloured tiles tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layers 15 mm thick in cement mortar (1:4) for laying floor finishes all as directed.
Material and labour for Non - skid Ceramic Coloured tiles tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting /dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over rendering 10 mm thick in cement mortar (1:4) for laying floor finishes all as directed.
Material and labour glazed ceramic coloured tiles of size not less than 450mmx350mmx7 to 8 mm thick coloured tiles on vertical surfaces set and jointed in neat cement slurry @ 3 Kg/Sqm and pointed in white or coloured cement to match the existing surface complete all as specified and directed.
M&L for Endura coloured ceramic tiles of size not less than 300 x 300 x 9 to 10 mm thick, set and jointed and pointed in neat cement slurry in floors laid over & including 15 mm thick screed bed in cement mortar 1:6 all as specified and as directed.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair complete all as specified and directed.
Material and labour for 10 mm thick rendering in cement mortar (1:6) on fair face of brick or concrete surface finished even and fair all as specified and directed.
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as on ceiling and finished fair and even complete all as specified and directed.
Material and labour for applying three coats of white washing on walls including preparing new plastered or unplastered surfaces complete all as specified and as directed.(Note:-The unit rate includes for:- (a) Use of all scaffolding, trestles, ladders, cradles, etc.necessary for execution of work and protective measures. (b) Removing of nails, making good holes, cracks, etc. (c) Work in patches, and in narrow widths. bands,cornices, pilasters, etc. and cutting in edges to line,where necessary. (d) Spreading and removing coverings to doors,windows, floors, fittings, etc., to protect them from splashes. (e) Removing and replacing furniture, movable cupboard, chicks, blinds, etc. (f) Washing floors, cleaning glass, joinery, electric fittings, wiring, etc. of drops and splashes and leaving premise, clean and tidy).
Material and labour for applying three coats of white washing on ceiling including preparing new plastered or unplastered surfaces complete all as specified and as directed.(Note:-The unit rate includes for:- (a) Use of all scaffolding, trestles, ladders, cradles, etc.necessary for execution of work and protective measures. (b) Removing of nails, making good holes, cracks, etc. (c) Work in patches, and in narrow widths. bands,cornices, pilasters, etc. and cutting in edges to line,where necessary. (d) Spreading and removing coverings to doors,windows, floors, fittings, etc., to protect them from splashes. (e) Removing and replacing furniture, movable cupboard, chicks, blinds, etc. (f) Washing floors, cleaning glass, joinery, electric fittings, wiring, etc. of drops and splashes and leaving premise, clean and tidy).
M&L for preparation of new surfaces and appplying two coats of weather coat (Apex) over two primer coats of damp shield to new plastered walls as per manufacturer instruction and applied by approved applicator complete all as specified and directed.
M&L complete removal of existing treatment and appplying two coats of weather coat (Apex) over two primer coats of damp shield to old plastered walls as per manufacturer instruction including properly filling of cracks and applied by approved applicator complete all as specified and directed.
Material and labour for preparation of new surfaces and applying two coats of distemper oil emulsion over a coat of primer and a thin layer(not less than 1mm) of wall care putty on wall complete all as specified and directed.
Material and labour for complete removal of existing treatment applying two coats of distemper oil emulsion over one coat of primer and a thin layer(not less than 1mm) of wall care putty, white or tinted on plastered surfaces of wall including preparation of surfaces all as specified and directed.
Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
Material and labour for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed.
Supply and fix, 3mm thick Sheet glass,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane all as specified and directed.
Supply and fix, 4mm thick Sheet glass,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane all as specified and directed.
Taking up or down 15mm bore of steel tubing and connections,including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm bore of steel tubing and connections,including cleaning for refixing or removal to store complete all as specified and directed.
S & F 15mm bore steel water tube,'medium grade',galvanised, with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S & F 20mm bore steel water tube,'medium grade',galvanised, with all fitting and fixed to walls and ceilings or laid in floors complete all as specified and directed.
Supply only, 15 mm bore pillar tap, fancy type cast copper alloy, with capstan head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe or for brass ferrule all as specified and directed.(Note:-Pillar tap shall be fixed with WHB).
Supply and fix in repair, 15 mm bore bib taps, cast copper alloy, cromium plated , fancy type,with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed.
Supply and fix in repair Stop valve for 15mm dia bore of pipe of PTMT any colour high pressure screwed for iron pipe and fixed(Minimum weight 15mm-90gms complete all as specified and directed.
Supply and fix, as in repairs, CP Towel Rail of 20mm dia not less than 600mm long between flanges all as directed.
Supply and fix, as in repairs,Soap dish of size not less than 160x160x90mm, any type, fixed to plugs with chromium plated brass screws all as specified and directed.
Supply, and fix 15 mm bore galvanized iron water tubing medium grade including all fittings and fixed complete to walls for water heater all as specified and directed.
Supply, and fix 25mm bore galvanized iron water tubing medium grade including all fittings and fixed complete laid in trenches including taking up or down old steel tubing all as specified and directed.
Supply, hosting and fix, 1000 liters rotational moulded polythene water storage water tanks three layer (cylindrical vertical with closed top) hoisted and fixed in position all as described in SSR Part I all as specified and directed.
S & F PTMT fittings shall be of approved makes for ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 2 0 m m - 2 1 0 g m s ) 20mm Bore dia of pipe in mm all as specified and directed.
S & F PTMT fittings shall be of approved makes for Nipple suitable for HDPE water tank (Minimum 20mm-45gms ) 20mm bore dia of pipe in mm all as specified and directed.all as specified and directed.
Dismantling Exc 500litre & n exc 1000litre water tanks and removing to store all as specified and directed.
Supply and fix , stop valve, cast copper alloy, cromium plated, fancy type, screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions all as specified and directed.
Supply and fix , 25mm dia gun metal gate valve conforming to relevant IS with iron wheel head screwed both ends for iron pipe all as specified and directed.
Supply and fix,as, as in repair, 75 mm dia of outlet PVC(SWR) floor trap, plain with granting including jointing with solvent cement all as specified and directed
Supply and fix as in repair, 20mm dia gun metal gate valve conforming to relevant IS with iron wheel head screwed both ends for iron pipe all as specified and directed.
Supply and fix in repair, vitreous china wash basin, white, flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed.
Supply and fix in repair, vitreous china squatting pan of Orrisa pattern size 580mm x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection making good to floor all as specified and directed.
Supply and fix , 10 ltrs capacity PVC valve less syphonic action type, low level flushing cistern, white, with inlet, ball valve float and handle including brackets complete all as specified and directed.
Supply and fix, as in repair, over head shower not less than 150 mm x 150mm square shape single flow (Brass chromium plated) with shower arm not less than 300mm long, including fixing to steel pipe or union of 15mm bore complete all as specified and directed
Supply and fix sinks with drainage board made of stainless steel not less than 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size not less than 915mm x 460mm and bowl size not less than 410mm x 330mm x 160mm complete all as specified and directed.
Supply and fix in repair ,stainless steel kitchen Plate Rack made out of not less than 0.63 mm thick stainless steel sheet and overall size not less than 800mm x 900mm x 250mm complete all as directed.Make:-Suyog/ Prayag or equivalent make as approved by HQ Eastern Command .
Supply and fix, as in repairs, 15 mm dia 600mm long connection pipe with two PVC PTMT nuts at each ends with rubber washer complete all as specified and directed.
Supply and fix, as in repair, sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
Supply and fix,as in repair 32mm dia PVC 610mm long waste pipe suitable for WHB complete all as specified and directed.
Supply and fix,as in repair 40mm dia PVC 610mm long waste pipe suitable for sink complete all as specified and directed.
Supply and fix,as in repair, waste coupling CP 32 mm dia for glazed ware basins etc with fly nuts flanged etc complete all as specified and directed.
Supply and fix,as in repair, CP 40mm dia waste coupling for stainless steel sink with inlet and outlet screwed for pipe or connections including packing , union and cap etc. complete all as specified and directed.
Supply and fix 110mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls all as specified and directed.
All as per item No 95 here-in-before but 75 mm bore.
Supply and fix PVC (SWR) bends (any radius) for 110 mm bore PVC pipes all as specified and directed.
All as per item No 109 here in before but 75 mm bore.
S & F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
Taking down existing damagedEWC/ IWC alongwith complete PCC and lime concrete from sunken floor and providing newEWC/ IWC and water proofing treatment to sunken floor as per following stage :- (i) 15mm thick plastering in CM (1:2) with water proofing compound as per manufacturers instruction at all around and base of sunken floor with proper slope. (ii) Applying a coat of 85/25 gde hot bitumen @ 0.7Kg/Sqm over a coat of bituminous primer @0.5Kg/Sqm and then pasteing of polythene film, 150 micron, natural colour with cold cut back adhessive. (iii) Fixing of 25mm dia GI pipe (med gde) spout of length 45 cm (iv) Supply & fixing of vitreous china squatting pan, "ORISSA" pattern, size 580x440mm white with integral footrest, P/S trap etc complete including providing PCC lean concrete in Mix 1:5:10 complete. NOTE: The integral waterproofing compound will be measured and paid under relevant item of BOQ.
(i) Demolition of old damaged existing water proofing compound on RCC roof of any description and specification and cleaning the surface thoroughly including 15 mm thick in cement mortar (1:4) on existing roof surface true to level after applying cement slurry @ 3 kg/sqm and applied coat of hot blown bitumen of graded 85/25 @ 1.2 Kg/Sqm.with laying 3mm thick APP based polymeric membrane of approved manufacture with weight not less than 3.60 kg per Sqm reinforcement with non-woven polyster febric weight not less than 150 gms per Sqm. The overlap shall be not less than 100 mm on transverse direction and 75mm on longitudinal direction and sealing overlaps and applying evenly one coat of aluminium paint @0.10 liter per square metre over the APP based polymeric membrance including taking down of water tank of any capacity and size with connections etc. and refixing the same in position complete all as directed.(Note:-Any damage to tank or pipe connection etc. will be replaced by new one by the contractor without any extra cost).
E/M WORKS:- Taking down carefully copper / alluminium point wiring (Light, fan, socket or power socket) complete including fixtures and fittings such as switches , ceiling reses, pendents, regulators, socket light fitting etc removing materials to store for keeping in safe custody for taking credit (credit for avobe items should be made as per condition seperatly) and making good desturbed surfaces of walls, floor, ceilings etc.
Taking down light fittings any wattage and any type complete all as directed.
Taking down DB/main switch of any size and making good disturbed surface of wall /floor complete all as directed.
Taking down submain wiring of any size complete all as directed.
Taking down fan, sealing cable end,dismantling blades and removing fan and blades to store complete all as directed.
Material and labour for concealed point wiring for fan / light / exjaust fan/ bell point controlled by one switch with 1.5 sqmm (nominal area) FR PVC insulated stranded copper conductor single core including non metalic PVC conduit medium grade of appropriate size concealed in wall, pressed steel concealed terminal boxes of required size and with top cover 3 mm thick of plastic laminated sheet of reqd colour, painting terminal boxes inside and out side with one coat red oxide primer complete with all accessories and all as specified including 1.5 Sqmm FR PVC insulated unsheathed multistranded copper earth conductor to common earth and connected to earth dolly for fan / light / exjaust fan/ bell point controlled by one switch all as specified and directed. Note:- Material and labourfor cutting chases on walls / ceiling and making good disturbed surfaces including finishing with cement mortar (1:3) etc; are deemed to be included in the quoted rate.
All as per item No 107 here-in-before but wiring with 1.5 sqmm for one 3 pin 5 Amps socket out let on independent board.
All as per item No 107 here-in-before but wiring with 1.5 sqmm for one 3 pin 5 Amps socket out let on sameboard.
All as per item No 107 here-in-before but wiring with 2.5sqmm including 1.5 sqmm PVC insulated, unsheathed multistranded copper conductor cable 1100 volts grade, single core, earth continuity conductor connected to common earth dolly for one15 Amps socket out let on independent board.
All as per item No 107 here-in-before but one light point conrolled by 2 way switches with cable 1.5sqmm size.
Supply and fix, switch piano, flush button, single pole, one way, 5 Amps, complete all as specified.
Supply and fix,Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified.
Supply and fix, switch socket combinatin 2 in 1, 3 pin, 5 Amps flush type all as specified and directed.
S & F Bell, AC, 230 volts, single pole complete all as specified and directed.
S & F Bell push, flush type, 5 amp complete all as specified and directed.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and directed.
Supply and fix, socket outlet 2 in 1, 5 pin, 5/6 Amps flush type all as specified and directed.
Supply and fix, switch socket combinatin outlet universal type 5 pin, 5/16 Amps flush type all as specified and directed.
Supply and fix, electronic type ceiling fan regulator, step type,120 W-2 module, suitable for 240 volts AC 100 watt all as specified and directed.
Supply and fix, LED Light Bulbs,Lumen output upto not less than 20watt and not less than 2000 lm of following specification:-(i) Colour rendering index (CRI) exceeding 80(ii)Lamp life (hours) not less than 15000 hours (iii)Colour temperature (kelvin) of 6500 K (iv)Light effect of Cool Daylight (v)Start up time not exc. 2 s (iv)Average lamp life (years) of 25 years (2.74 h/day usage time (IEC 60064))(v)Rated luminous flux light output (Lumens) of not less than 2000 lm complete all as per manufacturer's instruction.
Supply and fix, LED tube light fittings complete suitable for not less than 1 x 20 watts 230 volts 50 Hz wall mounted batten type with intregrated electronic driver complete with all acessories internally pre -wired and including connecting up with copper cable of suitable size and required length completeall as specified and directed.
Supply and fix,not less than 30 W ( 3000 System Lumens ),high efficacy LED street lights Class I,IP66,IK07 with efficacy of greater than 105 lm/W ,wide Voltage Operating Range of 140 V - 270 V,wide temperature operating range of -10 °C to +50 °C,surge Protecion of 4 kV driver builtin surge protections and additional 10 kV surge protecion device complete all as per manufacturer''s instruction.
M&L for Sub main wiring with two run of 4 Sqmm PVC insulated copper cable 1100 volts grade stranded copper conductor cable drawn through and including PVC casing capping pipe medium grade suitable size with all fittings and accessories including one run of 2.5 Sqmm stranded PVC unsheathed copper cable for earth continuity and connected to common earth dolly. Note : Two run of 4 sqmm wire with one run of 2.5 sqmm and one run of casing capaing shall be measured against one unit and paid to contractor.
Supply and fix, sheet metal enclosure powder coated single phase DB vertical type for fixing of MCBs, SPN DB 8 ways double door with bus bar 200 Amps including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
Supply and fix, Loadline TP&N vertical loadline DB fitted with Bus Bars, Neutral Links, Blanking Plates (without MCCB), 4ways ,Double door type,suitable for TP/FP complete all as specified and directed.
Supply and fix,MCB C Curve ,Single pole + Neutral 240 V,Nominal Rating 6-32 Amps, 10 kA ISI marked as per IS/IEC 60898-1 2002 Integrated label holder sliding bottom clamp, improved air channels, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters, DC-80 V per pole - 1 kA all as specified and directed.
Supply and fix,MCB C Curve ,Single pole 240/410 V,Nominal Rating 6-32 Amps, 10 kA ISI marked as per IS/IEC 60898-1 2002 Integrated label holder sliding bottom clamp, improved air channels, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters, DC-80 V per pole - 1 kA all as specified and directed.
Supply and fix,MCB C Curve ,Single pole 240/410 V,Nominal Rating 40 Amps, 10 kA ISI marked as per IS/IEC 60898-1 2002 Integrated label holder sliding bottom clamp, improved air channels, color coded On/Off indication on dolly, biconnect lower terminals, IP 20 protected terminals, sliding shutters, DC-80 V per pole - 1 kA all as specified and directed.
M & L MCCB 3 Pole .415 V. fixed type,25 to 100 Amps with breaking capacity 16 KA all as specified and directed.
Supplied & fixed 240 V , 20amp single pole enclosure with a two pin and earth plug and socket complete with one single pole MCB complete all as specified and directed.
Supply,laying,jointing,commissioning and testing underground XLPE insulated armoured (heavy duty) LT electric cable with stranded aluminium conductor suitable for working voltage 1100 V grade 4core cross sectional area 25Sqmm confirming to IS:7098 PT-I cable laid in trench or passing though pipe or fixed to pole all as specified and directed
Materials and labour for sand cushioning with dry course sand to UG cables (8 cm deep before laying of cable and 15cm deep over the cable) in trenches including punning thickness up to 18 cm and consolidation, complete all as directed. (Note :- Punned thickness only will be considered for payment).
Material and labour for for brick protection over cables inside the trench by using common burnt clay building bricks,sub-class"B" designation 75mm,laid dry and flat and widthwise along the axis of the trench complete all as specified and directed.
M & L Painting of ceiling fans complete, in situ with synthetic enamel paint(white paint) by spraying including filling cavities with filler, one coat including writing of MES No. of fan in capital letters with black synthetic enamel paint of height not less than 20mm on fan body in approved pattern after cleaning all dust etc. all as specified and directed.
M & L Painting of exhuast fans complete, in situ with synthetic enamel paint(gray paint) by spraying including filling cavities with filler, one coat including writing of MES No. of fan in capital letters with black synthetic enamel paint of height not less than 20mm on fan body in approved pattern after cleaning all dust etc. all as specified and directed.
M & L Painting of wall mounted fans complete, in situ with synthetic enamel paint(gray paint) by spraying including filling cavities with filler, one coat including writing of MES No. of fan in capital letters with black synthetic enamel paint of height not less than 20mm on fan body in approved pattern after cleaning all dust etc. all as specified and directed.
Supply and fixing as new exhaust fan size of sweep not less than 300 mm heavy duty energy saving single phase, 230 volts, 50 HZs complete all connecting accessories including making suitable size of brick wall to be fitted louver of fan and all electric connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed.
M & L for rewinding of ceiling fan 1200mm any make and any type of model after taking burnt out old winding wire complete nd cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG varnishing baking in oven and reasssembling with new bearings both complete all as specified and directed.
Hanging only ceiling fan (M.D.supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed.(Note:-The unit rates includes for clamps, hooks, holdfasts etc. for hanging fans).
Material and labour for earthing complete with galvanized steel plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level with top edge of earth plate not less than 1.5 mtr deep below normal ground level and connected to galvanized iron or steel earth wire lead 4 mm dia by means of bolts nuts, check nuts and washers protected by galvanized iron pipe 15 mm bore (medium grade) and connected to main switch board or main control board as directed with and including concrete pit in PCC (1:3:6) type CI and pre cast RCC 1:1.5 : 3 type A1, cover slab of size 30 cm cx 30 cm x 5 cm reinforced with 8 mm dia deformed bars both ways @ 10 cm C/C with one lifting handle made out of 8 mm dia MS bar, funnel wiremesh, 20 mm bore GI pipe light grade for watering, charcoal or coke and salt in alternate layers, necessary excavation and earth works in any type of soil complete all as shown on electrical plate No 3 MES schedule part – I and testing on completion all as specified and directed.
Supply & fix water heater (Gyser) storage type, single phase, energy saving 5 star rated 230 volts grade 5 star rated 25Ltrs storage capacity including nut bolts , washers and other site required accessories including taking down old gyser along with accessories complete complete
Chinmay Traders
M/S M.S. ENTERPRISE
THE BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .