Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.8 L+₹89,680.66 (4.29%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
27 Jan 2024, 3:00 pmClosed
The Executive Engineer, KWA, P H Division,Thrissur
The Executive Engineer, KWA, P H Division,Thrissur
Construction_Renovation of Civil structures of KWA_state plan2023_24 Rennovation of office building _Wadakkanchery Sub division and Section Office_General Civil Work
2024_KWA_647376_1
122/EE/PHD/TSR/2023-24
Open Tender
Civil Works - Others
Item Rate
90 days
Wadakkanchery
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹50,000
21 Feb 2024
20 Jan 2024
29 Jan 2024
20 Jan 2024
27 Jan 2024
20 Jan 2024
20 Jan 2024 - 27 Jan 2024
Amount
1- APPENDIX-A-RENOVATION WORKS OF OFFICE BUILDING.
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
5.9.4:Centering and shuttering including strutting, etc. and removal of form for:Shelves (Cast in situ)
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
5.36:Providing and placing in position precast reinforced cement concrete waffle units, square or rectangular as per design and shape for floors and roofs in 1:11/2:3 ( 1 cement : 1 1/2 coarse sand : 3 graded stone aggregate 10 mm nominal size), including flush or deep ruled pointing at joints in cement mortar 1:2 (1 cement : 2 Fine sand), making necessary holes of required sizes for carrying through service lines etc., providing steel hooks for lifting etc, form work in precasting, handling, hoisting, centering and erection complete for all floor levels but excluding the cost of reinforcement .
5.22.3:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelCold twisted bars
50.9.2.3:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction of Engineer in -charge. using Vengai wood
10.30.1:Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
50.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
50.14.1.1:Removing and refixing door shutters after necessary repairs for easy opening and closing etc complete as per the direction of site Engineer-in-charge.
13.41.1:Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work ( Two or more coats) over and including priming coat with water thinnable cement primer
14.43:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
13.52.1:Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
10.3:Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer .
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
18.10.6:Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work- Exposed on wall50 mm dia nominal bore
10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
12.51.1:Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05%) total coated thickness, zinc coating 120 grams per sqm as per IS:mm(+0.05%) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete:Ridges plain (500-600 mm)
18.12.7:Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work65 mm dia nominal bore
18.38.6:Painting G.I pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work:50 mm diameter pipe
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.21:Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
OD231577/2022-2023: Providing & installing Work station tables made out of 17mm prelaminated board for top & verticals,drawer sides, 9mm thk. prelaminated particle board for drawer bottom, all exposed edges should be covered with .8 x 22mm PVC edge band.The rates are including cost of Keyboard tray,Wire manager, etc. complete as per design and directions of the architect/consulting engineer
OD150443/2023-2024:Providing & installing Work station tables made out of 17mm prelaminated board for top & verticals,drawer sides, 9mm thk.prelaminated particle board for drawer bottom, all exposed edges should be covered with .8 x 22mm PVC edge band.The rates are including cost of Keyboard tray,Wire manager, etc. complete as per design and directions of the architect/consulting engineer.
OD150442/2023-2024:Watchman Ledge
OD150456/2023-2024:Revolving Chairs - Damro/Godrej Damro Low Back Chair [Product ID : OCL 020 Black] / Godrej Sally Mid Back Chair [Product ID : 56101522SD04098]
13.47.1:Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
13.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
2-APPENDIX-B-All Electrical components replacing , repairing etc
OD243650/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. GROUP A 1.10.1
OD243710/2023-2024:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. GROUP B 1.10.2
OD243718/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet.1.24.4
OD243725/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp Switch outlet.1.24.1
OD243734/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch outlet.1.24.3
OD243739/2023-2024:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet.1.24.5
OD243784/2023-2024:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
OD243783/2023-2024:Supply and wiring points according to IS 732- 1989 using rigid PVC condust of minimum size 20mm with specially conforming to IS 3419 – 1988 fixing the condust using metal sadels spacing not exceeding 50cm or concealed suitable and 2.5 sq mm PVC insulated standard single core copper conductor cable 550V grade and continuous earthling with 2:5 sq mm green colored FR PVC insulated standard single core copper conductor cable 650V grade generally conforming to IS 694-1990 complete with suitable size industrial type plug and suitable size Modular Metal switch boxes and all the termination in the switch board and DBY shall be tinned and wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. a) Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
OD243782/2023-2024: Supply and wiring points according to IS 732- 1989 using rigid PVC condust of minimum size 20mm with specially conforming to IS 3419 – 1988 fixing the condust using metal sadels spacing not exceeding 50cm or concealed suitable and 2.5 sq mm PVC insulated standard single core copper conductor cable 550V grade and continuous earthling with 2:5 sq mm green colored FR PVC insulated standard single core copper conductor cable 650V grade generally conforming to IS 694-1990 complete with suitable size industrial type plug and suitable size Modular Metal switch boxes and all the termination in the switch board and DBY shall be tinned and wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. b)Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 1.12
OD243781/2023-2024: Supply and wiring points according to IS 732- 1989 using rigid PVC condust of minimum size 20mm with specially conforming to IS 3419 – 1988 fixing the condust using metal sadels spacing not exceeding 50cm or concealed suitable and 2.5 sq mm PVC insulated standard single core copper conductor cable 550V grade and continuous earthling with 2:5 sq mm green colored FR PVC insulated standard single core copper conductor cable 650V grade generally conforming to IS 694-1990 complete with suitable size industrial type plug and suitable size Modular Metal switch boxes and all the termination in the switch board and DBY shall be tinned and wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. c)Supply and fixing plug point with 25A 3 pin socket controlled by 25A switch in independent position.
OD243780/2023-2024:Supply and fixing plug point with 32Amp. Metal clad 3pin socket, Top and controlled by 32A. Switch (industrial type) in independent position. Supply and wiring points according to IS 732- 1989 using rigid PVC condust of minimum size 20mm with specially conforming to IS 3419 – 1988 fixing the condust using metal sadels spacing not exceeding 50cm or concealed suitable and 2.5 sq mm PVC insulated standard single core copper conductor cable 550V grade and continuous earthling with 2:5 sq mm green colored FR PVC insulated standard single core copper conductor cable 650V grade generally conforming to IS 694-1990 complete with suitable size industrial type plug and suitable size Modular Metal switch boxes and all the termination in the switch board and DBY shall be tinned and wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.
OD250060/2023-2024:Supply and drawing 640/110V grade PVC insulated standard copper conductor cable conforming to IS 694 part 1 – 1990 in the existing surface/recess condust as required including giving necessary connection of the following sizes. a)4 sq mm copper conductor
OD250129/2023-2024:Supply and drawing 640/110V grade PVC insulated standard copper conductor cable conforming to IS 694 part 1 – 1990 in the existing surface/recess condust as required including giving necessary connection of the following sizes. a)2.5 sq mm copper conductor
OD250133/2023-2024:Supply and drawing 640/110V grade PVC insulated standard copper conductor cable conforming to IS 694 part 1 – 1990 in the existing surface/recess condust as required including giving necessary connection of the following sizes. a)1.5 sq mm copper conductor
OD250148/2023-2024:Supply and fixing the following size PVC conduct conforming IS 9537/1983 part III along with all required accessories on surface including making good the damages etc. as required. a) 20 mm dia medium guage 1.21.1
OD250362/2023-2024:Supply and fixing the following size PVC conduit conforming IS 9537/1983 part III along with all required accessories on surface including making good the damages etc. as required. a) 25 mm dia medium gauge 1.21.1
OD243774/2023-2024:Supply and installation of sheet steel, photophaitised and painted, dust and vermin proof enclosure of MCB DB including copper/brass bus bar, neutral link, earth bus and Din rail suitable anchor or fixed in recess including cutting hole on the wall, making good damage, colour washing etc. Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.2
OD243796/2023-2024:Supply and installation of the following accessories suitable for 50HZ AC supply conforming to IS 8828 – 1995/ICC 60898 of the following current ratings in the existing enclosure and giving connection as required. A) 100A, 25/35kA, 4pole MCCB setting 80-100% with adjustable OL
OD243795/2023-2024:Supply and installation of the following accessories suitable for 50HZ AC supply conforming to IS 8828 – 1995/ICC 60898 of the following current ratings in the existing enclosure and giving connection as required. 32A 10KA, TP MCB (C curve) 2.10.4
OD243794/2023-2024:Supply and installation of the following accessories suitable for 50HZ AC supply conforming to IS 8828 – 1995/ICC 60898 of the following current ratings in the existing enclosure and giving connection as required. c ) 5-32A 10KA, SP MCB (C curve)
OD243793/2023-2024:Supply and installation of the following accessories suitable for 50HZ AC supply conforming to IS 8828 – 1995/ICC 60898 of the following current ratings in the existing enclosure and giving connection as required. d) 100A, 4 pole 415 volts RCCB having sensitivity upto 300mA
OD243792/2023-2024:"Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required"
OD243791/2023-2024:Supply and drawing copper earth conductor from main panel to earth pit a ) 10 SWG copper conductor 50+50 100
OD243790/2023-2024:Supply and fitting 100 A TPN 415 volts Main switch with HRC fuse
P SUNILKUMAR
Bidder Name
PREMJITH K.K
P SUNILKUMAR
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_992772.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .