Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC J 16 RANJIT NAGAR JANTA FATAK ROAD JAMNAGAR 361005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L1 | Accepted-AOC L1 AND REASONABLE | |
| 2 | L2₹22.3 L+₹1.3 L (6.42%)Rejected-Finance | L2 | Rejected-Finance NOT L1 | |
| 3 | L3₹23.2 L+₹2.3 L (10.9%)Rejected-Finance 1ST COMPLEX RADHANPUR ROAD NEAR BYPASS CIRCLE OPP 1SQUARE MARKET MAHESANA GUJARAT 384002 | MAHESANA | GUJARAT | 384002 | L3 | Rejected-Finance NOT L1 | |
| 4 | L4₹23.7 L+₹2.7 L (12.9%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L4 | Rejected-Finance NOT L1 | |
| 5 | L5₹24.0 L+₹3.0 L (14.5%)Rejected-Finance | L5 | Rejected-Finance NOT L1 |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
26 Feb 2022, 6:00 pmClosed
OFFG GE A Jamnagar
INFANTRY LINES JAMNAGAR
SPL REPAIR TO ROOF TREATMENT AND ALLIED WKS IN OFFRSS MESS(P-140), QUARTER GUARD(P-102) AND JCOS SINGLE LIVING ACCN (P-446) AT MIL STN JAMNAGAR
2022_MES_504289_2
8875
Open Tender
Civil Works
Item Wise
180 days
Jamnagar
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE ARMY JAMNAGAR
₹43,000
Yes
11 Mar 2022
12 Feb 2022
28 Feb 2022
12 Feb 2022
26 Feb 2022
18 Feb 2022
Amount
Taking down all existing roof treatment and demolition of cement concrete padding/levelling course incl wire brushing and cleaning loose dust etc from surfaces of RCC roof incl flashing and juntion of parapet complete all as specified.
M&L cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified.
M&L 25mm thick PCC 1:2:4, type B0 (using 12.5mm size stone aggregate) as levelling course incl finished even and smooth using extra cement complete all as specified
M&L 10mm thick screed bed in cement plaster 1:4 on padding layer for roof treatment with WPC complete all as specified
Supply only Integral waterproofing compound
M & L for water proofing treatment to non-accessible roof slabs by applying one coat of bituminous primer conforming to IS-3384 @ 0.30 litre/sqm and laying Atactic Polypropylene (APP) modified membrance , reinforced with non woven ployester, of 3.50 Kg/sqm (minimum, 3mm thick (minimum), with minimum 75 mm side overlaps and 100mm end overlaps and applying one coat of bituminous aluminium paint over APP membrane all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on brick or stone walls incl raking out joints hacking for key, scrubing down with water etc.
M&L 10 mm thick rendering on internal wall surfaces in cement plaster 1:6 on fair faces incl finished even and smooth w/o using extra cement all as specified.
M&L for 5 mm thick rendering in CM 1:3 over ceiling surfaces complete incl finishing the surfaces even and smooth w/o using extra cement.
M&L 15 mm thick rendering in in two layers 5mm thick in CM 1:4,over 10mm thick cement plaster in CM 1:6 on fair face of brick work/Stone or concrete surface to be finished even and smooth without using extra cemen Including WPC compound 3% by weight of cement.(Note :a) integral WPC Compound shall be used in sencond layer,b) Intergial WPC shall be paid seperately on supply only..
Preparation of newly plastered surfaces of wall incl sweeping clean with brush to remove loose dust, sand, etc and applying two coats of heavy duty waterproofing coat (Dr Fixit Wounderproof-1 or equivalent) by mixing water @ 25-30% to make slurry coating and allow 4 to 6 hrs time for drying up of first coat before application of second coat in perpendicular direction of first coat and further left to dry for 4 hrs complete all as specified and directed as per manufacturer instructions.
Preparation of newly plastered surfaces of wall making surface smooth by application of 2mm thick wall care putty and applying two coat of oil bound distemper with roller finish complete all specified and directed.
M&L preparation of newly plaster surfaces of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M & L for preparation of new plastered surface of ceiling and applying two coats of white wash
M&L preparing old surfaces of ceilings by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss & efflorescent salts and trading oil and greasy spots and applying one coat of white wash on ceiling etc complete all as specified and as directed by Engineer-In-Charge.
M&L preparing the old distempered surfaces on walls including filling holes and undulations with putty and applying one coat of oil emulsion distemper on walls with roller finish complete as specified and as directed by Engineer-In-Charge.
M&L preparation of old painted surfaces of wood/ wood based materials of any description over 10Cm width or girth and applying one coat of synthetic enamel paint etc. complete all as specified and directed by Engineer-In-Charge.
M&L preparation of old painted surfaces of steel/ iron of any description over 10Cm width or girth and applying one coat of synthetic enamel paint etc. complete all as specified and directed by Engineer-In-Charge.
Material and labour for complete removal of existing treatment from plastered or unplastered surfaces of walls including cleaning with scrapers, any number of coats and any width or girth etc, the area of application should be cleaned thoroughly, remove all dirt, dust and uneven elements from the surface by washing and scraping and all the unevenness in the surface should be corrected by filling the exterior wallcare putty, surface should be sanded down with fine grade sand paper for smoothness applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces,as per manfecturars instructions complete all as directed and specified.
Removal of all loose/unsound/bad/damaged concrete or plaster existing RCC structure of slab/beams/walls by using chesel/hammar .Cut and remove unsound reinforcement bars, wires etc without damaging the sound reinforcement . clean loose rust from bars manually with brush . fixing new supplymentary bars if required,either by tying it with existing bars or by welding on it. Applying eppoxy bonding agent and making good with polymer modified plaster/micro concrete as required thickness over a coat of rust removing alkaline primer and match the finishing to the existing surface in ground floor including formwork complete all as specified and directed.
ABR Trading Co
MADHAV ENTERPRISE
Ravi enterprise
badri glass and construction
jitendra c joisar
SHELANI CONSTRUCTION
VINUBHAI P. CHANDRA
lakhanibrothers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .