Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹9.7 LAdmitted-Finance | -32.10% | ₹9.7 L | L1 | Admitted-Finance |
Tender Value
₹14.2 L
EMD Value
₹28,400
Closing Date
11 Aug 2026, 6:00 pmClosed
EXECUTIVE ENGINEER
KDA KOTA
Operation, Maintenance and Security of LED High mast Lights in Area of KDA Kota
2026_UITKo_582654_1
16/2026-27 (80)
Open Tender
Electrical Works
Percentage
365 days
KOTA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Online Through SSO Portal
₹28,400
Yes
17 Aug 2026
5 Aug 2026
12 Aug 2026
5 Aug 2026
11 Aug 2026
5 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Operation, Maintenance and Security of All Typee Of LED Street Light System With Fixtures and Perform Following Work.(i)Maintain power supply (underground and overhead) from kedl/jvvnl energy meter to auto on off pannel to feeder piller to pcc/tubular pole to led light.(ii)Repair , Rectification, Replacement of defective component of the Existing Led light or entire led light if required so to run led light system.(iii)Replacement of old led light with new led light if led found broken/damage/stolen.(iv)Replacement of damage or burnt cable/overhead line/fuse box with new cable/overhead line/fuse box from from kedl/jvvnl energy meter to auto on off pannel to feeder piller to pcc/tubular pole junction in supervision of engineer for this work payment shall be extra.(v)Repair of damage cable and overhead line from kedl/jvvnl energy meter to auto on off pannel to feeder piller to pcc/tubular pole.(vi) Replacement and repair of damage /burnt /stolen cable , wire or jumper from junction box to light and pcc pole to light .(vii)Operation maintenance and security of auto on off pannel installed by contractor as well as exist old pannel . If any part of pannel found defective/burnt/ stolen/damage contractor have to replace it with new parts and run the led system properly. ( 1450 LED Flood Light *12 Months = 17400) | 17,400 | Nos | 53 | ₹9,22,200 |
| 2Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 2.1 | 10.0 Sq. mm | - | - | - | - |
| 2.2 | 4 core * 10 sqm | 200 | Mtr | 192 | ₹38,400 |
| 2.3 | 3.5 core*25 sqm | 200 | Mtr | 256 | ₹51,200 |
| 3Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 3.1 | High Power LED Flood Light Minimum lumen output 18650 lm | 38 | Each | 10,857 | ₹4,12,566 |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.88 MB
CONDITIONS_E_80.pdf
Tender Documents • 0.38 MB
BOQ_1035142.xls
BOQ • 0.38 MB
Corrigendum16.pdf
PDF • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].