GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
COMPREHENSIVE MAINTENANCE OF CENTRAL TYPE AC PLANTS UPTO 30TR CAPACITY AND IMPROVEMENT SERVICING REPLACEMENT OF UNSV SPARE PARTS AND ALLIED WORKS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2026_MES_799369_1
8721/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹500
GE (I) DM Visakhapatnam
₹95,240
Yes
18 Nov 2026
18 Nov 2026
11 Dec 2026
18 Nov 2026
9 Dec 2026
2 Dec 2026
19 Nov 2026 - 30 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Preventive maintenance of central type AC plant by carrying out routine check of the Plant complete for smooth functioning all as per manufacturer's instructions and as directed for 15.0Tr *03 nos installed at 20 MOUT bldg including attending to under mentioned jobs to ensure its satisfactory performance:-
Note: Quoted Rates are deemed to be for carrying out checks as under.
(a)Contractor has to deploy manpower at the worksite to attend the breakdown calls received from representatives during two shifts throughout the week including sundays & holidays and on emergencies in third shift shall be attended ,preventive maintenance for the entire duration of contract.It is the contractors responsibility to make the unit functional and sufficient stock of spares shall be maintained to rectify the breakdown within scheduled period. | 11 | Per Month | - | - |
| 1.02 | Cleaning, stacking, sorting, handling and upkeeping of maintenance shall be carried out by contractor.
(b)checking the system for visual leaks at all flare fittings and arresting
(c)carrying out leak test with soap solution in case reports indicate frequent loss/recharging of refrigerant into the system whenever required
(d)checking operation ,suction& discharge pressures.In case of any abnormality identifying and correcting the same
(e)checking and setting of safety controls such as HP/LP cutouts,overload protections and thermostats etc.
(f)cleaning of pre air filters and replacing the same if necessary
(g)checking lubricating oil level at the sight glass if found below the normal level the problem shall be analyzed and rectified. | - | - | - | - |
| 1.03 | (h)Running of standby unit and observe for satisfactory performance.
(i)checking the incoming voltage and running currents and take appropriate measures
(j)checking for any abnormal noise/vibration from moving parts such as compressors,motors,fans etc in case of any abnormality,investigating and correcting the same
(k)checking and rectifying any water leaks and arresting them
(l)checking the operation of controls and making them functional
(m)checking and cleaning of fan,runner blades and replace if required
(n)cleaning cooling coils by cleaning agent (CFC free)
(o)checking the cooling tower water level
(p)checking the water level in the makeup water tank | - | - | - | - |
| 1.04 | (q)starting and checking the running condition of cooling tower fan
(r)starting the pump and checking the running condition including checking the NRVs
(s)cleaning condensate drain tray
(t)checking the cooling tower nozzles for proper spray and replacing the same if necessary
u)Descaling the condenser and replacing the condenser end shield gaskets
Record of these shall be maintained and submitted monthly to engineer in charge
The above quoted rate is inclusive of all spare parts apart from below mentioned spare parts which will be paid seperately to make the unit completely functional, T&P manpower required in the site | - | - | - | - |
| 2 | All as per item No. 1.00 above, but for 25 Tr x 3 Nos. at 43 central bldg | 11 | Per Month | 1 | ₹11 |
| 3 | All as per item No. 1.00 above, but for 20 Tr x 2 Nos. at 15 bldg | 11 | Per Month | - | - |
| 4 | All as per item No. 1.00 above, but for 11 Tr x 2 Nos. at 17 bldg | 11 | Per Month | - | - |
| 5 | Repairs, overhauling and servicing of upto 30 Tr AC Plant compressor by stripping out both end covers, cylinder head, cylinders, connecting rod, crank shaft, oil pump, side covers, bush bearings etc.,and refrigerant taking the cylinder for reuse (if available) of unserviceable worn out parts in the compressor, cleaning the system with CO2/Nitrogen gas for leak detection for minimum 24 Hrs, after flushing out the system, vacuumization and charging with refrigerant gas & compressor oil and testing the unit on no load and full load conditions all as specified and directed.
Note:- Supply only refrigerant gas, compressor oil and spare parts for the compressors will be measured and paid under relevant items of Schedule ’A’. | 10 | Job | - | - |
| 6Supply only following spare parts suitable for SMC 6-65 ‘Accel’ make or equivalent all as specified and directed. | |||||
| 6.01 | Bushing with collar standard | 2 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
BOQ_896855.xls
BOQ • 0.29 MB
8721Tender.pdf
Tender Documents • 0.89 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .