Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.1 LAccepted-AOC 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | ₹27.1 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹27.5 LRejected-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | ₹27.5 L | L2 | Rejected-AOC Other Than Lowest Bidder |
| 3 | L3₹33.3 LRejected-AOC HOUSE NO 3363 SECTOR 27 D CHANDIGARH | NA | NA | 160001 | ₹33.3 L | L3 | Rejected-AOC Other Than Lowest Bidder |
| Sl No | Description | Qty | Unit | M/S MATLOOB AHMED L1 | M/s Super Trading Corporation L2 | His Construction Company L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down Cement plaster or cement lime plaster on brick or stone walls including raking out joints, hacking for key & scrubbing down with water etc including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. | 276 | SQUARE METRE | 35 ₹9,660 | 40 ₹11,040 | 45 ₹12,420 |
| 2.00 | Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas,facia and similar suspended work including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. | 1 | CUBIC METRE | 900 ₹900 | 1,000 ₹1,000 | 800 ₹800 |
| 3.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. | 445 | SQUARE METRE | 15 ₹6,675 | 33 ₹14,685 | 40 ₹17,800 |
| 4.00 | Demolition of Cement concrete unreinforced as in Ground Floor and paving n. exc. 15cm thick (above or below G.L.) complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. | 7 | CUBIC METRE | 800 ₹5,600 | 396 ₹2,772 | 48 ₹336 |
| 5.00 | Demolition of cement concrete of any description and in any position including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge. | 2 | CUBIC METRE | 900 ₹1,800 | 800 ₹1,600 | 800 ₹1,600 |
| 6.00 | Taking down chowkhats or frames n.exc 1.5 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts complete all as specified and directed by Engineer-in-Charge. | 20 | EACH | 250 ₹5,000 | 225 ₹4,500 | 300 ₹6,000 |
| 7.00 | Taking down chowkhats or frames exc 1.5 sqm but n.exc 4 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts etc complete all as specified and directed by Engineer-in-Charge. | 8 | EACH | 250 ₹2,000 | 250 ₹2,000 | 200 ₹1,600 |
| 8.00 | Taking down shutters of any description exc 1.0 sqm but n.exc 2 sqm each and removing from the site complete all as specified and directed by Engineer-in-Charge. | 6 | EACH LEAF | 80 ₹480 | 48 ₹288 | 85 ₹510 |
| 9.00 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc, removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge. | 12.3 | 10 SQUARE METRE | 125 ₹1,537.50 | 150 ₹1,845 | 150 ₹1,845 |
| 10.00 | Demolition and breaking up pipes (PVC,Salt glazed ware, AC or Reinforced concrete) set in cement mortar from any situation complete all as specified and directed by Engineer-in-Charge. | 60 | RUNNING METRE | - | 25 ₹1,500 | 25 ₹1,500 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
6 Oct 2025, 6:00 pmClosed
GE CHANDIGARH
GE CHANDIGARH N AREA OLD AIRPORT CHOWK CHANDIGARH 160003
GE CHD T 34 2025 26 MAINT AND MISC REPAIR WORKS TO CERTAIN MD, OTM ACCN AT N AREA AND OFFICES AND MESSES OF CECZ ,GE CTL AND GE CHANDIGARH UNDER GE CHANDIGARH
2025_MES_724590_2
GE/CHD/T-34/2025-26
Open Tender
Civil Works
270 days
CHANDIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE CHANDIGARH
₹50,000
Yes
30 Dec 2025
15 Sept 2025
8 Oct 2025
15 Sept 2025
6 Oct 2025
23 Sept 2025
16 Sept 2025 - 20 Sept 2025
Amount
Taking down Cement plaster or cement lime plaster on brick or stone walls including raking out joints, hacking for key & scrubbing down with water etc including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floors) beams, slabs, staircases, landing, chajjas,facia and similar suspended work including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Demolition of Cement concrete unreinforced as in Ground Floor and paving n. exc. 15cm thick (above or below G.L.) complete including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete of any description and in any position including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames n.exc 1.5 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhats or frames exc 1.5 sqm but n.exc 4 sqm each (without taking off shutter from the frame) and removing from the site including dismantling brick work of hold fasts etc complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1.0 sqm but n.exc 2 sqm each and removing from the site complete all as specified and directed by Engineer-in-Charge.
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc, removing rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up pipes (PVC,Salt glazed ware, AC or Reinforced concrete) set in cement mortar from any situation complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections of 15mm bore in pipe, including cleaning for re-fixing or removal from site to store complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections of 20mm bore in pipe, including cleaning for re-fixing or removal from site to store complete all as specified and directed by Engineer-in-Charge.
Dismantlling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings in any position complete all as specified and directed by Engineer in Charge.
Disconnecting existing tanks of capacity exc. 250 ltr & n. exc. 500 ltr,, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning, repairing, complete all as specified and directed by Engineer-in-Charge.
Dismantling existing tanks of capacity exc 250 ltr but not exc 500 ltr and removing to store complete all as specified and directed by Engineer-in-Charge.
Dismantling existing tanks of capacity exc 500 ltr but not exc 1000 ltr and removing to store complete all as specified and directed by Engineer-in-Charge.
Demolition of brick work or stone/boulder masonary built in cement mortar incl all quions arches, pillar or any other descrption etc including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Demolition of cement plaster,loose concrete,pointing,old loose foreign particles,old APP,vegetation with roots if any including brushing with wire brushes for removing caked mud etc. sweeeping with brooms and finally fanning the cleaned surface with gunny bags or air blower to remove all loose dirt etc(excluding mud phuska ),preparing surface for screed bed for APP membrane including removal of any existing treatment including disposal of unservicable rubbish outside Cantt area all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new onescomplete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete, all as specified and as directed by Engr-in-charge.
Plain cement concrete (1:4:8) type D-2,using 40 mm graded stone aggregate as in subbase,path,foundations, filling and mass concrete, sub base etc complete all as specified and directed by Engineer-in-Charge.
Plain cement concrete 1:2:4 type B-0 using 20mm graded crushed stone aggregate as in cement concrete in roof kerbs,roof padding or mud stops,back filling of chowkats, coping,bed plates rounded or chamfered on edges with and including using necessary use and waste of formwork for fair finished surface complete all as specified and directed by Engineer-in-Charge.
Reinforced Cement Concrete nominal mix 1:2:4 type b-1 using 20mm graded mechanically crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
Hardcore of Broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled with mechanical means to a true surface complete, all as specified and directed by Engineer-in-Charge.
TMT steel bars 10mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
TMT steel bars 6mm to 8 mm dia and over, of grade Fe-500D cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge.
Mild Steel Framed work as in guard bars/grills, gratings, etc.. with ends of bars shouldered/welded and/or riveted, or forged into spikes; framed guard bars/grills conforming to Fe-290 (Gde E-165) complete all as as specified and directed by Engineer-in-Charge.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws,hooks etc complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE
Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws,hooks etc complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE
Vitrified ceramic tiles double charged light shade 10 mm thick (Square/rectangular) polished, area of each tiles exceeding not exceeding 0.36 Sqm, in floor,skirting etc set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and including 15mm thick screed bedding layer in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
First quality Non - skid coloured Ceramic tiles 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm as in floors etc. set and jointed with 4 mm spacer and grouting the joint of flooring with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 laid over and inculding 15 mm thick screed in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
Glazed ceramic digital coloured tiles 450 x 300 x 7mm thick on vertical surface such as skirting , dado etc. over and including 10 mm thick rendering in CM 1:4 thick set and jointed with 4 mm spacer and grouting the joint of walls with epoxy grout mix of organic coated filler of desired shade,hardener ,resin in the ratio of 8:1:2 complete all as specified and directed by Engineer-in-Charge.
Factorymade rubberized prepolished vibratory compacted chequered tiles 300mm x 300mm x 25 mm thick set,jointed and pointed in neat cement slurry with grey pigment over and inculding 20 mm thick screed in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Marble work 18 to 20mm thick shade of marble green (table rubbed and polished) as in flooring,tread,Riser and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, laid over & including 20 mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing as in cooking platform,jamb,cill,steps,risers complete all as specified and directed by Engineer-in-Charge.
Fixing only Marble work 18 to 20mm thick shade of marble green (table rubbed and polished) as in flooring,tread and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, laid over & including 20 mm thick screed bed in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing as in cooking platform,jamb,cill,steps,risers complete all as specified and directed by Engineer-in-Charge.
Machine cut Kota stone slab flooring 22-25 mm thick,SIZE 55 CM x 55 cm laid over & including 20 mm thick screed bed in cement mortar 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed by Engineer-in-Charge.
Machine cut Single piece Kota stone slab 22-25 mm thick as in skirting,steps, dado and pillars etc , laid over & including 10 mm thick rendering in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and directed by Engineer-in-Charge.
Granite jet black shade, 18-20 mm thick, (table rubbed and polished) in single piece (in one direction) machine cut, machine polished, bedded and jointed with adhesive suitable for granite/stone & pointed with grout of matching shade including necessary cutting over & including 10 mm thick (average thickness) cement mortar (1:3) screed, as in cooking platform, jamb,step,riser, shelves, RCC counters, window cills & similar situations, complete including grinding,rounded and chamfered edges and granite polishing all as specified and directed by Engineer-in-Charge.
Brick work with sub class 'B' bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
Brick work with sub class 'B' bricks, class designation 100, old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6 EXCEPT BRICKS complete all as specified and directed by Engineer-in-Charge.
Water proofing roof treatment/Sunken treatment using APP polymeric water proofing membrane minimum 3 mm thick and weighting not less than 3.6 Kg/Sqm black finish reinforced with non-woven polyster matt wt not less than 150 gms/Sqm with thermo fusable finish laid over compatible bitumen primer at the rate of 0.40 Ltr/Sqm over cleaned surface including parapet,applying a coat of blown bitumen 85/25 grade @ 1.2 kg per square metre over priming coat torching over laps with a propane or butan gas torch with a over lap of 100 mm at the side and 150 mm at the ends and sealing all as per manufacturers instructions incl wire brushing and cleaning the top surfaces of concrete, roof surfaces etc. with water including flashings and junction of parapets etc complete all as specified and directed.
Providing and laying cool roof temp shield tiles 300mm x 300mm x 10 mm thick as in terraces,roof pavement as in horizontal and slant/vertical surfaces with 4 mm groove filled with epoxy joint filler over and including 15 mm thick screed in cement mortar 1:6 set jointed and pointed in neat cement slurry in floors complete, all as specified and as directed by Engineer-in-Charge.
Rendering 15 mm thick in cement mortar 1:3, on roof surfaces including flashings and junction of parapets,brick or concrete surfaces mixed with water proofing compound , trowelled to even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. NOTE: Water proofing compound shall be measured and paid separately.
Rendering 15 mm thick in cement mortar 1:6, on fair faces of brick or concrete surfaces , trowelled to even and smooth surface without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Rendering 15 mm thick in cement mortar 1:4, on wall/,brick or concrete surfaces of building upto 10 mtr in height mixed with water proofing compound on top layer, trowelled to even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge. NOTE: Water proofing compound shall be measured and paid separately.
Supply only liquid water proofing comound ISI Marked complete all as specified and directed.
Rendering 10 mm thick in cement mortar 1:3 as in ceiling/soffits of slabs/Chajja/ Sunshade finishing the plastered surface even & smooth without using extra cement etc complete all as specified and directed by Engineer-in-Charge.
Preparation of surfaces of walls brooming down, applying one coat of white cement based wall care putty 1 mm thick etc complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatment,preparation of surfaces of wall and applying two coats of oil bound distemper on walls including one coat of white cement based wall care putty 1 mm thick and a coat of primer complete all as specified and directed.
Preparation of new plastered surfaces of wall and applying two coats of oil bound distemper on walls over and including one coat of white cement based wall care putty 1 mm thick and a coat of primer including preparation of surface complete all as specified and directed.
Preparation of new plastered surfaces and applying two coats of cement based paint over a coat of primer etc including properly filling the cracks with putty complete all as specified and directed by Engineer-in-Charge.
Preparation of plastered or unplastered new surfaces of ceilings and applying three coats of white wash including preparation of surface complete all as specified and directed by Engineer-in-Charge.
Preparation of old Plastered or un-plastered surfaces of walls etc by brooming down or steel wire brushing, scrapping down smoke soot moulds, moss, efflorescence salts treating oil and greasy spots etc and applying two coats of oil bound distemper etc including properly filling the cracks with putty complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatment,preparation of surfaces of ceiling and applying two coats of white wash on ceiling including one coat of white cement based wall care putty 1 mm thick and a coat of primer complete all as specified and directed.
Complete removal of existing treatmen,preparation of surfaces of walls brooming down, applying one coat of white cement based wall care putty after applying emery paper or sand paper and two coats of cement based paint over a coat of primer etc complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatmen,preparation of surfaces of walls brooming down, applying one coat of white cement based wall care putty after applying emery paper or sand paper and two coats of weather proof exterior emulsion paint(Ist quality) Apex over a coat of primer on damp surfaceas per manufacturers instructions etc complete all as specified and directed by Engineer-in-Charge.
PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site including cover fillets complete all as specified and directed
PVC louvers wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site including cover fillets complete all as specified and directed
Supply and fixing in PVC prelaminated Gypsum Ceiling board laminated with texure vinyl coated paper tiles of size 595mm x 595mm x 10mm thick with and including anodised aluminium snap grid framework for ceiling having grid size 605 x 605 mm comprising of wall angle of size 25 mm x 25 mm x1.3 mm,main runner of size 38 mm x 25 mm x1.3 mm. The grid system shall be suspended at every 1200 mm c/c in both directions by using 3.5 mm dia aqualine wire fixed to purlin or RCC roof with suitable fasteners to withstand the load of grid system with ceiling board complete all as specified and as directed by Engr-in-charge.Colour to be decided by GE
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles),With Wood free EPS with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification to be fitted in the MS frame welded/scaled to the stiles & rail with suitable PVC sheet beading & jointed together with solvent cement supply & fixing in the frame at site as per specification & drawing.
35 mm thick factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
Solid PVC door frames of size 50mm x 47 mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube, and edges will be painted to match with printed sheet, supply & fixing in opening as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
Factory made box type steel windows with pressed steel frame min 1.25 thick complete including mild steel acessories like lugs, door stopper, holdfasts, pintol hinges, handles( minimum One for each shutter), and ISI marked tower bolt 150mm size (minimum 2 for each shutter) etc. with glazing bars and without glazing bars (Double shutter ) dovetailed or welded with one shop coat of zinc chromate primer, complete all as shown on drawing No. TD-276(R), Sheet No 1/4 to 2/4, 3/4, 4R/4 and as specified and directed by Engineer-in-Charge. Note: (i) Fabrication as per TD-276 (R) SH 1/4 to 2/4, 3/4, 4 (R) /4 (ii)Mode of measurement Unit will be for the complete window except Glass/ Gauge but incl fittings, ISI marked iron mongery complete as per TD. (iii) The PCC back filling in chowkhat of window, Grills,Sheet glass and wire gauge will be measured and paid separately against respective items.
Factory made box type steel ventilator with top hung or fixed half glass and half wire mesh portion shutter including projecting type hinges, steel peg stay, complete all as specified and directed by Engineer-in-Charge.Note:Sheet glass and wire gauge will be measured and paid separately against respective items
Powder coated aluminium (minimum thickness of powder coating 50 micron) frame work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge.
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per drawings and the directions of Engineer-in-Charge
Aluminium anodised,barrel tower bolts of extruded section with length of bolt 150 mm and dia of bolt not less than 10 mm,ISI marked complete all as specified and directed by Engineer-in-Charge.
100 mm Butt hinges, medium weight, cold rolled stainless steel, and fixed with screws or with welding to existing MS frames complete all as specified and directed by Engineer-in-Charge.
125 mm long Aluminium handles, cast type,anodised complete all as specified and directed by Engineer-in-Charge.
100 mm long Aluminium handles, cast type,anodised complete all as specified and directed by Engineer-in-Charge.
Peg stays of aluminium alloy anodised 150 mm complete all as specified and directed by Engineer-in-Charge.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
Sheet glass 5.5 mm thick, tinted and glazing with linseed oil pane putty & spring glazing clips using Silicon for fixing of glass in addition to glazing putty, in squares not exceeding 0.5 Sq. mtr in each pane, complete all as specified and directed by Engineer-in-Charge.
Sheet glass 4 mm thick, plain and glazing with linseed oil pane putty & spring glazing clips using Silicon for fixing of glass in addition to glazing putty, in squares not exceeding 0.5 Sq. mtr in each pane, complete all as specified and directed by Engineer-in-Charge.
4 mm thick figured glass pin head type and glazing with oil putty in square not exc 0.5 sqm each and using Silicon for fixing of glass in addition to glazing putty complete all as specified and directed by Engineer-in-Charge.
Preparation of old or previously treated wooden surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Preparation of old or previously treated steel and iron surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs Vitreous China wash down water closet pan (pedestal pattern), white with plastic seat cover (excluding fixing bolts, flushing cistern and flush pipe) and making connections complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs Vitreous China Wash down water closet single piece of size 365 x655 x765 mm white including 10 ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float ,connection pieces,P or s trap (closed pattern) including all necessary accessories like rag bolts,kit/gel gasket,PVC seat cover,Jet and flush pipe complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs Ball valves for 20 mm bore high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs hydrolica plastic water closet seat cover white coloured closed pattern with flat bottom with mild steel chromoum plated hinge device for pedestal pani complete all as specified and directed by Engineer-in-Charge.
10 ltr capacity PVC valveless, syphonic action dual flush type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, 32 mm dia flush pipe complete all as specified and directed by Engineer-in-Charge.
Vitreous China bowl urinal half style white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and Union for discharge pipe. complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs vitreous china oval shaped wash hand basin white of size 560x470mm including fitting in granite shelf /RCC slab , chromium plated waste coupling, waste pipe etc., (incl all waste fittings) complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs vitreous china wash hand basin white with pedestal ,flat back of size 550x440mm including galvanised iron brackets , chromium plated waste coupling, waste pipe etc., (incl all waste fittings) complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs 15 mm fancy type chromium plated fancy type bib tap brass long body with flange screwed down high pressure CP cast copper alloy with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union complete all as specified and directed by Engineer-in-Charge.
15 mm fancy type chromium plated fancy type Pillar taps, cast copper alloy, with capstan heads,chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs 15mm bore stop valves/angle valve fancy type cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repair Brass chromum plated wash hand basin mixer with spout for mixing hot and cold water fancy type with long screwed shanks and flynuts screwed down for 15mm dia iron pipe complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs PVC waste pipe 32 mm dia,800 mm long flexible for Sink and WHB complete all as specified and directed by Engineer-in-Charge.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore including jointing to waste pipe in cement concrete type B-1 (1:2:4) fixed in repair complete all as specified and directed by Engineer in Charge.
75mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts complete all as specified and directed by Engineer-in-Charge.
110 mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with and including MS clamps made out of flat iron of size 25 mm x 3 mm including nuts,bolts complete all as specified and directed by Engineer-in-Charge.
PVC(SWR) bends (any radius), for 75 mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge.
PVC(SWR) bends (any radius), for 110mm bore pipes, with access doors, complete all as specified and directed by Engineer-in-Charge.
15mm bore steel water tubing medium grade, galvanized with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors complete all as specified and as directed. all as specified and directed by Engineer-in-Charge.
20 mm steel water tubing medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs complete all as specified and directed by Engineer-in-Charge.
Fixing only 15mm bore steel water tubing medium grade, galvanized with all fittings and fixture fixed & concealed in wall/ceiling or laid in floors complete all as specified and as directed. all as specified and directed by Engineer-in-Charge.
Fixing only 20 mm steel water tubing medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including in short lengths standard clamps and screws fixed on rawal plugs complete all as specified and directed by Engineer-in-Charge.
CPVC(SDR-11) of outer dia 25 mm with and including CPVC SDR-11 fittings on walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge.
CPVC(SDR-11) of outer dia 20 mm with and including CPVC SDR-11 fittings on walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 brass elbow fittings, ISI marked for CPVC pipe outer diameter 20 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 brass TEE fittings, ISI marked for CPVC pipe outer diameter 20 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 brass UNION fittings, ISI marked for CPVC pipe outer diameter 25 mm bore complete all as specified and directed by Engineer-in-Charge.
CPVC SDR- 11 Female Brass Threaded Adaptor (FTA/ FBTA) fittings, ISI marked for CPVC pipe outer diameter 20 mm bore complete all as specified and directed by Engineer-in-Charge.
Note: For the purpose of arriving at Net contract sum amount, the amount of credit schedule i.e Sch 'A' section II (i.e Rs 39265.00 shall be deducted from the total amount arrived.
Total of Schedule 'A' Rs.
M/s Super Trading Corporation (BID ID -3438714)
His Construction Company (BID ID -3444052)
Bidder Name
M/S MATLOOB AHMED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid