Loading…
Loading…
Tender Value
₹12.3 L
EMD Value
₹12,500
Closing Date
17 Jun 2026, 6:00 pm
Chief Officer, Mahuva Nagar Palika, Mahuva
AUGMENTATION OF SEWER LINE AND CONTROL PANEL BOARD IN VARIOUS HEAD WORKS AT MAHUVA TOWN, MAHUVA DIST. BHAVNAGR UNDER 15 PERCENTAGE VIVEKADHIN SCHEME ( 6th ATTEMPT )
310987
20250302R06
Open
Electrical - All
Bhavnagar
2 documents required · 2 mandatory
₹900
Mahuva Nagarpalika Mahuva
₹12,500
3 Jun 2026
3 Jun 2026
3 Jun 2026
17 Jun 2026
3 Jun 2026
NAME OF WORK: - AUGMENTATION OF SEWER LINE AND CONTROL PANEL BOARD IN VARIOUS
HEAD WORKS AT MAHUVA TOWN, MAHUVA DIST. BHAVNAGR UNDER 15% VIVEKADHIN SCHEME (
SR. NO. DISCRIPTION AMOUNT
SCHEDULE AUGMENTATION OF SEWER LINE AND CONTROL PANEL BOARD IN VARIOUS
B-1 HEAD WORKS AT MAHUVA TOWN, MAHUVA DIST. BHAVNAGR UNDER 15%
VIVEKADHIN SCHEME ( 6th ATTEMPT )
I/We am/are willing to carry out the work at % above/below percent (should be written in figures and words) of the tendered amount
mentioned above.
Tendered amount put to tender Rs.12,26,179.00 Tendered amount put to tender Rs.12,26,179.00
Deduct. % below Rs. Add.: % Above Rs.
President, Chief Officer
Signature of Contractor. Mahuva Nagarpalika Mahuva Nagarpalika
MAHUVA NAGARPALIKA
NAME OF WORK : - AUGMENTATION OF SEWER LINE AND CONTROL PANEL BOARD IN VARIOUS HEAD
WORKS AT MAHUVA TOWN, MAHUVA DIST. BHAVNAGR UNDER 15% VIVEKADHIN SCHEME ( 6th
Qty Unit Description Rate
Excavation for pipe line trenches for water supply, sewerage line,
manhole etc. all with shoring and struting if required as per required
1 gradient and line including safety provisions using site rails and stacking
excavated stuff including up to all required lead cleaning the site etc.
complete for all lifts and strata as specified.
Upto 0.00m to 1.50m
2.52 Cum In all sorts of soil and soft murrum 102.35
2.52 Cum In hard murrum, boulders 155.25
2.52 Cum In Soft Rock 187.45
17.64 Cum In Hard Rock 427.80
RCC pipes( horizontal cast) : Providing and supplying ISI standard RCC
pipes (of sulphate resistance cement) in standard length of following
class and diameter suitable for rubber ring joints, including all taxes,
insurance, transportation, freight charges, octroi, inspection charges,
loading, unloading, conveyance, to departmental stores, staking etc.
Note: One collar should be supplied with each full length plain ended
RCC pipe, cost included in rates below. One rubber ring should be
supplied with each full length socketed pipe, cost included in rates
20.00 Rmt 5) Class NP3 test pressure 0.7 kg/sq.cm 300 mm Dia 755.00
Lowering, laying and jointing, RCC pipes in C:M 1:1 1/2 of following
diameters in proper position grade alignment, as directed by engineer in
charge, including, conveyance from store to site work, layout giving
hydraulic testing as per ISI code.
Refilling the pipeline trenches incl. ramming, watering, consolidating
desposal of surplus stuff as directed within a radius of 3 km.
S.I.T.C of LV ATS - MCC Panel totally enclosed, dust & bermin proof,
indoor type, minimum degree of protection - IP 52 as per IS:
operation on 3- Phase, 4 Wire, 415V, 50Hz, Neutral effectively
grounded, with instrumentation compartments accomodating LED type
indicating lamps, control contactors as per IS: 13947, CT of accuracy
class- I as per IS: 2705, relays, meters & control MCBs, air insulated
electrolitic grade Aluminum busbar for three phase & neutral system
with incomming breaker- microprocessor based Air Circuit Breakers
(electrically operated drawout type)/ air break fixed type MCCB with
trip free mechanism, current limiting type as per IS: 8828, Motor
Contractor (as per type -2 coordination), Overload Relay with built-in
single phasing prevention feature & auxiliary feeders as per SLD
drawings, momentary contact type push buttons, equipment fittings, bus
bars, cable boxes, cable gland, incoming & ougoing cable connection for
1100V grade, Aluminium/ Copper conductor XLPE/ PVC insulated &
PVC sheathed armoured cable, 10% spare terminals, power wiring using
1100V grade, FRLS insulated copper conductor wires conforming to IS:
694 & 8130, cable compartments/ alleys of minimum 300 mm size, GI
earth bus bar for entire length. With required capacity of fixed / dynamic
APP type capacitor banks in MCC panels.
Each capacitor shall be provided with capacitor duty (AC 26 B)
contactor and MCB (only D Curve) of required amperage. The fixed
capacitor bank type panels should be suitable to improve power factor
from 0.85 lag to 0.95 considering total working load MCC shall be
fabricated from cold rolled, coled annealed (CRCA) sheet steel &
minimum thickness of various members shall be as follows: Base Frame/
Channel/ Gland Plate - 3 mm, Load Bearing Members/ Doors - 2 mm
and Internal Partitions - 1.6 mm - as per Technical Specification with
Encloser size of Minimum Depth 1500mm with 600 mm L x 2175 mm
H) or as per requirement ATS Strater minimun - 10 Kw incomming &
KW Two outgoing Working Feeder & Extra feeder 63 A - 1 No + 5KW
- 3 Nos. for Auxilary load + 32 A -2 No.
Microprocessor based Soft Starter with built-in by pass
contactor,Semiconductor Fuses, Harmonic Filters, cast resin type CT,
Digital MFM Analog Ammeter & minimum 10 Channel Temperature
Scanner with RS 485 communication port
3.00 No. 700 x 600 x 2175mm- 95HP Motor at Compose Pumping Station 275000.00
1.00 No. 700 x 600 x 2175mm- 25HP Motor at Gaghati Pumping Station 143000.00
1.00 No. 700 x 600 x 2175mm- 25HP Motor at Kishan Pumping Station 143000.00
1.00 No. 700 x 600 x 2175mm- 10HP Motor at Meldi Mata Pumping Station 88000.00
Total Net Cost in Rs.
I/We am/are willing to carry out the work at % above/below percent (should be written in figures and words) of the tendered amount
mentioned above.
Tendered amount put to tender Rs. 12,26,179.00 Tendered amount put to tender Rs.
Deduct. % below Rs. Add.: % Above Rs.
President, Chief Officer
Signature of Contractor. Mahuva Nagarpalika Mahuva Nagarpalika
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.Tender.pdf
02 Form B-1.pdf
03 SCHEDULE B.pdf
4.Term and condition-4.pdf
05 ELECTRICAL WORK SPECIFICATION.pdf
06 Finance Dept GR.pdf
07 GR All.pdf
Download all tender documents and submit your bid