Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.2 LAccepted-AOC WARD NO 19 PO PURI PS KUMBHARAPADA DIST PURI PIN 752001 | PURI | PURI | ODISHA | 752001 | ₹79.2 L | L1 | Accepted-AOC The bidder has won the transparency lottery among the qualified bidder so that the work has been awarded to him |
| 2 | L1₹79.2 LRejected-AOC | ₹79.2 L | L1 | Rejected-AOC Rejected |
| 3 | L1₹79.2 LRejected-AOC AT BRAHMESWAR PATNA P O BADAGADA BRIT P S BADAGADA BHUBANESWAR | BHUBANESWAR | ODISHA | ₹79.2 L | L1 | Rejected-AOC Rejected |
| 4 | L1₹79.2 LRejected-AOC | ₹79.2 L | L1 | Rejected-AOC Rejected |
| 5 | L1₹79.2 LRejected-AOC BHATANA OSAKANA NAUGAON JAGATSINGHPUR | JAGATSINGHAPUR | ODISHA | 754102 | ₹79.2 L | L1 | Rejected-AOC Rejected |
Tender Value
₹93.2 L
EMD Value
₹93,204
Closing Date
24 Dec 2025, 5:00 pmClosed
Er.Soumya Ranjan Dwibedi
O/o the S E R and B Division Puri
Construction of Administrative Building-cum-Laboratory (G plus 1) with furnishing, peripheral Development at Coconut Research Station Konark
2025_EICCL_123465_1
TCN No 46 of 2025-26
National Competitive Bid
Civil Works - Buildings
180 days
Puri
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹93,204
Yes
30 Apr 2026
18 Dec 2025
26 Dec 2025
18 Dec 2025
24 Dec 2025
18 Dec 2025
Ground Floor
Providing & laying Granite Stone Flooring using 20 mm thick Granite Stone Slab of approved quality, colour and size between 0.4 Sqm. to 1.0 Sqm. & above in Stair Case Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443/1972 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade including cost of all labour, materials,royalties, loading and unloading, conveyance, sundries, watering and curing, making three nos horizontal grooves in treads etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of stone tiles shall be approved before procurement and use.)
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge.
Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.
Earth work excavation in ordinary soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of engineer-in-charge.
Up to 1.50 m Depth:
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge.
1.50 to to 3.00 m Depth:
Ground Floor
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge.
Filling in Foundation, Plinth and other low laying area with excavated materials including cost of all labour, T&P etc complete including watering and ramming as directed by the Engineer-in-charge .
Ground Floor
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge.
Supplying and filling in foundation and plinth with sand including watering and ramming, poking and compacting including cost, conveyance, royalties, taxes of the materials and cost of all labour, labour cess, T&P etc. required for the work complete as directed
Ground Floor
by the engineer-in-charge.
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge.
2.50sqmm flat cable
Providing and laying Plain Cement Concrete of proportion (1:3:6) using 4 cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including the cost of all materials, cost of labour, conveyance, taxes, royalties, loading, unloading, shuttering, centering, curing, labour cess, T&P, etc. all complete as per the direction of engineer-in-charge.
Ground Floor
Terrace Floor
Ground Floor
R.C.C. Foundation and Footing Bases of Columns Mass Concrete Pre-Cast Slab etc.
Ground Floor
First Floor
by the engineer-in-charge.
R.C.C. Grade Beams
Ground Floor
First Floor
by the engineer-in-charge.
Lintel
Ground Floor
First Floor
by the engineer-in-charge.
Staircase
Ground Floor
First Floor
Cutting, Straightening coiled or bent up M.S. rods or Tor steel welding or jointing if necessary, bending, binding, tying the grills as required for R.C.C. works, providing fan hooks where necessary and hoisting, lowering and placing in proper position according to approved designs and drawings including cost, conveyance, loading, unloading, taxes of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T&P and scaffolding complete in all respect as directed by the Engineer in charge (payment will be made according to the actual weight of M.S. rod / Tor steel consumed in the work and no separate payment will be made towards weight of binding wires which is to be borne by the contractor at his own cost).
Ground Floor
First Floor
Second Floor (Head Room)
RCC Columns & Beams, Roof Beam
Ground Floor
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge.
RCC Floor and Roof Slab, Landing, Balconie, Projecting Sun shades and Chajja up to 4.3 Mtr Height
Ground Floor
First Floor
by the engineer-in-charge.
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge.
Providing Fly-Ash Brick masonry work in F&P using Fly-Ash Bricks of size 250mm x 120mm x80mm having crushing strength not less than 75Kg/Sqcm in cement mortar (1:6) including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, royalties, labour cess, scaffolding, curing for required period, T&P, etc. all complete as per the direction of the engineer-in-charge.
Ground Floor
First Floor
Providing 12 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) and finished smooth to the rough surface of masonry walls after racking out joints including watering and curing, rounding of corners etc. complete with cost, conveyance, royalties and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge.
Ground Floor
First Floor
by the engineer-in-charge.
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge.
Providing 16 mm. thick cement plaster in all floors at all height with cement mortar of mix (1:6) and finished smooth to the rough surface of masonry walls after racking out joints including watering and curing, rounding of corners etc. complete with cost, conveyance, royalties and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. with providing grooves as directed by the Engineer in charge.
Ground Floor
First Floor
by the engineer-in-charge.
Providing 1st class Fly Ash Brick Masonry Work Using (250mmx120mmx80mm) Size Fly-Ash in Superstructure having crushing strength not less than 75Kg/Sqcm in Cement Mortar (1:6) after immersing the bricks for minimum 6 hours in water before use with all necessary projections, splays cutting, circular moulding, coFBelling etc as per drawings. including cost, conveyance, all taxes, royalties, loading and unloading of all materials, including cost of all labour, scaffolding, watering and curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge.
Ground Floor
First Floor
Providing 6mm thick Cement Plaster(1:4) to RCC surface finished smooth including closed deep chipping & slurry treatment with ordinary Portland cement (OPC) and with screened and washed sharp sand for mortar and finished smooth to the rough surface including watering and curing rounding of corners etc. complete with cost, conveyance, royalties and taxes of all materials, cost of all labour, T&P, sundries and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
Ground Floor
First Floor
by the engineer-in-charge.
Providing and laying Brick masonry work in Superstructure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge.
Ground Floor
First Floor
Provinding and fixing of WPC Door Frames having the density 1000kg/M3 ,Walnut or any type of surface colour treatment ,100% water proof, termite proof & environment friendly including fire Retardent ,UV Resistant with Rebate cuts and Finished cross section size 75mm X 45mm or 90mm x 50mm ,including cost of all materials,one coat primer,all labour, conveyance, taxes, loading, unloading, scaffolding, staging, T&P, etc.Complete as per the direction of the Engineer-in-charge.
Ground Floor
First Floor
Ground Floor
First Floor
Supplying and fixing W.I. clamps 33cm to 38Cm long of 35mm × 5mm size for doors, windows and ventilators including fixing in cement concrete (1:3:6) with 12mm, to 20mm hard stone chips or in cement mortar (1:3) including cost of all materials.
Ground Floor
First Floor
by the engineer-in-charge.
Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete as per the direction of Engineer-in-charge.
Ground Floor
First Floor
by the engineer-in-charge.
Supplying, fitting and fixing of Unplasticised Poly Vinyl Chloride (UPVC) (Fenesta/NCL VEKA Ltd) Sliding Windows -60 Series duly manufactured using UPVC reinforced profiles of 108mmx45mmx2.5mm for outer outer frames and window sash of 39mmx58mmx2.5mm capable of mounting single glazing system, structurally reinforced with hot dip galvanised upto 50 microns of minimum thgickness of 1.5mm prefabricated and wellded through fusion welding and the window frame shall be fitted with 6mm thick clear toughened glass of saint gobain make duly fiuxed with EPDM weathering seal resistant and the system is to be installed using reinforced large coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/deglazing at site, etc. including cost and conveyance of all materials, accessories, labour charges and product confirming to ASTMD 638-14,EN-477-95 and other applicable codes and standards.
Ground Floor
First Floor
by the engineer-in-charge.
Supplying, fitting and fixing of G.I. Grills in Gate & windows made out of G.I. square bars, angles, flats, etc painted with red oxide primer cost of all materials, labour, conveyance, taxes, loading, unloading, T&P, etc. all complete.
Ground Floor
First Floor
by the engineer-in-charge.
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, labour, T&P etc.as per the direction of engineer-in-charge.
Supplying and finishing the plastered surface of wall using Cement Based Wall Putty (Water Based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge.
Ground Floor
First Floor
by the engineer-in-charge.
Providing and Painting with Two Coats Weather Coat Paint (exterior grade) of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalent to make an even finished surface over a coat of water bound cement primer and wall putty in all heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete.
Ground Floor
First Floor
by the engineer-in-charge.
Providing and applying 2 Coats Plastic Emulsion Paint of approved quality and shade over a coat of wall primer of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance,royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use)
Ground Floor
Painting Two Coats of Synthetic Enamel Paint over Iron Works as per approved shade of approved quality over a coat of primer, sand papering, polishing the surface including cost, conveyance,labour, T&P, scaffolding etc. as required for the work complete as per direction of Engineer-in-charge. (The paints and primer are to be approved before procurement and use).
Ground Floor
First Floor
Supplying, fitting and fixing vitrified industrial floor tile of approved make and size (300 mm x 300mm) confirming to IS:4457 laid on 20mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.
Ground Floor
First Floor
Supplying, fitting and fixing Mattfinished vitrified tile in floors of size 600mm x 600mm (Plain/ivory) of approved make confirming to IS:13755 laid on 20mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.
Ground Floor
First Floor
Supplying, fitti
Ground Floor
First Floor
ng and fixing glazed Vitrified tile in Dado/Skirting and risers of steps on 12mm thick cement mortar (1:3) (1 Cement : 3 Coarse sand) jointed with neat cement slurry mixed with colouring pigments to match the colour and shade including the cost of washing, polishing, cost of materials, cost of all labour, conveyance, taxes, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.
Ground Floor
First Floor
Providing & laying Granite Stone Flooring in Floors and Landing using 20 mm thick Granite Stone Slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.
Ground Floor
First Floor
Providing & laying Granite Stone tiles in Dado/Skirting using 10mm thick Granite Stone Slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar (1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.)
First Floor
by the engineer-in-charge.
Providing and laying 25mm thick grading Concrete of proportion (1:2:2) using 6mm size crusher broken black hard granite chips from approved quarry, scraping and cleaning the surface, fininishing smooth to proper slope and gradient including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, curing,T&P, etc. all complete as per the direction of the engineer-in-charge.
Paver Road
Boundary Wall
Construction of granular sub-base by providing close graded Grading-VI material of table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with vibratory roller to achieve the desired density including cost of all materials, cost of labour, conveyance, taxes, loading, unloading, T&P, etc. all complete as per the clause of MoSRT&H specification for road and bridge work.
Internal & External E.I. Work
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, laying in uniform layers with paver in subbase/ base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per Clause 406 of MoSRT&H Specifications for Road & Bridge works (4th Revision).
Providing ,laying factory made 80 mm thick cement concrete interlocking paver blocks of M-30 grade made by block making machine with strong vibratory compaction of approved size and shape laid over 50mm thick compacted bed of course sand layer including filling sand in the interstics/ joints, including cost conveyance of all materials, labour, and (T&P) required for the work etc comple and as per direction of Engineer in charge.
Providing, lifting, hoisting and laying in position machine batched , machine mixed and machine vibrated design mix cement concrete of M-20 Including the cost of Centering and Shuttering (minimum cement content not less than 347 Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance,loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions (as per IS 9103) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement.
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)2 X 1.5 sq.mm +1 X 1.5 sq.mm in 20 mm dia
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB ) (4X6+2X4)
Supply and drawing of following sizes FR PVC insulated single core multistrand co
pper conductor in existing surface/ recessed/ STEEL / PVC conduit as required. 1 X 1.5sqmm inverter wiring
Aluminium alloy tubular bimetallic heavy duty cable socket
Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 3.5Cx50sqmm (2 run ) with end termination
Laying of one number of PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required.
Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1KV grade of size not exceeding 25 sq.mm on surface as required.
3.5Cx50sqmm
Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.
50 mm dia
SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2000 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years .
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 12 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 12 watt and lumen output of 1200 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
S/F of Street light- 45W,120 lm/w efficacy , new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (2Years Warranty) with Supply of fixing of 40 mm GI Brackt with 2 nos GI clamp & 4 nos 3'' Anchor fasteners for fixing of street light.
Supply and fixing 10 Watt LED B.H fittings (Make-Havells/ Cona/ Panasonic)
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colourceiling fan with aluminium blades and air delivery ≥215m3/min(Usha - striker/ Crompton - Super breeze Deco/ Havells - samraat/ Orient - pspo/ Or equivalent) ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 2 years.. .48" Ceilling fan
Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
6 Way(6+18) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door Warranty on DB is 3 years
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Supplying and fixing 25Amps rating,C series,10KA breaking capacity, DP 240 volts, MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 3 years.
Recessed wiring to light point/Fan point/ Exhaust fan point/Call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 6Amp, 250V Modular switch(Legrand mylinc/ Schneider clipsal/Hager insysta/Anchor Dura/ or equivalent) ISI marked and ceiling rose ISI marked mounted on metal box having front Modular cover of suitable size, metal box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accessories and connection.(Make of wire-L&T/Anchor/Havells/V-Guard/Great White/HPL)
Supplying and fixing 63Amps rating,C series,10KA breaking capacity, 4P 415 volts MCB Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The MCB should be Replacement Warranty will be 3 years.
Supply and fixing of G.I Earthing with G.I earth pipe 3mtr. Long 40mm dia ISI marked including accessories and providing masonary with charcoal and salt as required.
Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years
Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
Group-A
Group-B
Supply and fixing of Electronics step type Modular fan regulator. ( Legrand mylinc/ Schneider clipsal/Hager insysta/or equivalent)
Group-C
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. ( Legrand mylinc/ Schneider clipsal/Hager insysta/ or equivalent ) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supply and fixing of Modular switch ,Socket , ( Legrand mylinc/ Schneider clipsal/Hager insysta/ or equivalent)
16Amp socket.(Modular type )( Legrand mylinc/ Schneider clipsal/Hager insysta/ or equivalent)
32 A DP modular switch with indicator, ISI marked
Supply and fixing Modular base & cover
1/2 module
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable
size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. ( Legrand mylinc/ Schneider clipsal/Hager insysta/ or equivalent )
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.( Legrand mylinc/ Schneider clipsal/Hager insysta /or equivalent)
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. ( Legrand mylinc/ Schneider clipsal/Hager insysta/ or equivalent)
Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
PH WORK
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC/upvc pipes and pipe fittings of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge(Supreme/Ashirvad/Oriplast)
Ground Floor
20mm dia CPVC pipe
25mm dia CPVC pipe
Supply and fixing Modular G.I. Box
32mm dia UPVC ASTM-D Pipes
First Floor
20mm dia CPVC pipe
1/2/3 module
S/I/T&Commissioning of LT out door floor mounted cubical type electrical panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING EMERGENCY LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 3 years & compelete test certificate must be submitted along with panel board including component list. 20X 3MM Separate al Earth bus bar should be installed.In commer - 01 no 100 A 4P MCCB 25kA, with ROM & S. Link. ( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) (Icu=100%Ics)with shunt trip. Busbar- 04 numbers of 100Amps Electrolytic copper busbar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. Out going- 04 nos 63A 4P MCB 10kA,C series for power BDB. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 , 04 nos 32A rating,10KA breaking capacity,C series, 2P MCB UPS Light load for each floor.Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9 Instrument- (i) 03 numbers phase indicating lamp with toggle switch & HRC fuse. (ii) 01 set of 0-100Amps Ammeter Digital type & CTS.(DIGITAL) (iii) 01 set of 0-500 voltmeter Digital type.(DIGITAL)
Providing and Fixing ISI marked ABC stored pressure type Fire extinguisher of 6 Kgs. Capacity confirming to IS: 15683 with discharge hose, nozzle, Mono Amonium Phosphate base & ABC powder pressurised with nitrogen gas carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.
Ground floor
First floor
Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class K.B brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge
Fixing 2000Ltr Roto-moulded water storage tanks-In 2nd floor
Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.
G.F.--250mm thick wall
F.F.--250mm thick wall
Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge
Providing and Fixing of 4.5 Kgs. Capacity CO2 gas type ISI marked fire extinguisher (IS: 15683) fitted with high pressure 1 mtr. Long discharge hose & horn complete with refill gas, carrying handle and wall mounting bracket etc as required.Make-Safex/Fireshield/Ceasefire
25mm dia UPVC ASTM-D Pipes
25mm dia UPVC ASTM-D Pipes
15mm dia Pillar cock (Jaquar KUP-CHR-35001PM)
15mm dia Sink cock (Jaquar )CON-CHR-347KNM
25mm dia CPVC Ball valve(Supreme/Ashirvad)
32mm dia CPVC Ball valve(Supreme/Ashirvad)
15mm dia CP flange
15mm dia CP extension piece
15mm dia CP Health Faucet (Hindware Health Faucet-Cat No-F160002CP
Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge
250mm to 375mm thick wall
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge
110mm dia U-PVC SWR pipe(Supreme/Ashirvad/Oriplast)
110mm U-PVC door Tee
110mm dia U-PVC Plain Tee
110mm U-PVC door bend
110mm U-PVC plain bend
110mm dia U-PVC plain shoe bend
110mm dia U-PVC offset without ear
110mm dia. U-PVC socket plain
110mm dia U-PVC 'P' trap
110mm dia U-PVC cowl
125mm dia CP grating
PVC clamp suitable for 50mm to 110mm dia pipe
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge
European water closet with ‘S’ trap plain with seat cover(Parryware/Hindware/Kerovit/Somay)
Supplying all materials, labour T&P and and fixing 10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main etc all complete as per the specification and direction of the Engineer in charge
10 Liters capacity PVC cistern with 32mm dia flush bend (SLIMLINE WHITE (Parryware/Hindware/Kerovit/Somay)
Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with cast iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge
600mmx450mmx250mm size porcelain Sink
Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make), etc all complete as per specification and direction of the Engineer in charge
Wash hand basin with full pedestal((Parryware/Hindware/Kerovit/Somay)
Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.
Half Stall urinal (Hindware make -60002)
15mm dia urinal spreader
32mm dia C.P. dome waste
Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge
B.E.Mirror
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
25mmx600mm long CP towel rail(Plaza/Aquatic/Amber/Kerovit/Somany)
CP Towel Ring(Plaza/Aquatic/Amber/Kerovit/Somany)
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
CP soap holder
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to woden plugs with CP screws as per specification and direction of the Engineer in charge
600mmx125mm size glass shelf with C.P guard rail
Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge
Inside size 250mmx250mm
Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class KB brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to
worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
Inside size 760mmx760mmx460mm
R.C.P.C Cover(18" round man hole cover)
Supplying all materials, labour, T&P and constructing man hole chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class K.B brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
Inside size 910mmx910mmx910mm
R.C.P.C Cover(24" round man hole cover)
Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
Brick masonry soakway pit 1.40m dia x 2.00m deep
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.
110mm dia alround concrete
Construction of 10 users Brick septic tank- 1 No.
Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge.
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
Ground floor
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In ground floor
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
In Foundation & Plinth
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
R.C.C floor and roof slabs
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Second Floor
32 mm dia UPVC ASTM-D Pipes
15 mm dia CP long body Bib cock (Plaza/Aquatic/Amber/Kerovit/Somany Cera/ HGydro)
15mm dia CP angle stop cock(Plaza/Aquatic/Amber/Kerovit/Somany Cera/ Hydro)
Sinking of 125 size tube well through Hand Boring (Water Jet) Method with Sanitary/ Saline Sealing (in all kinds of soil)
Supplying all materials, labour, tools and plant and setting up boring equipments including erection of suitable staging for installation of the required size of tubewell, dismantling and removing the same after completion of the work, includifng transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc. levelling of site all complete as per direction of Engineer-in-charge.
Supplying all labour, tools and plants and transporting boring pipes, top casing, grouting pipes, PVC pipes and fittings, PVC well screens, cement bentonite and gravels etc to work sites including loading and unloading etc. complete as per the direction of the Engineer-in-charge
Truck load
Supplying all labour, tools and plants and drilling pilot bore not less than 102 mm dia without casing pipes in all kinds of soils for the following depths excluding supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per the direction of Engineer-in-charge
Labour for drilling 125mm dia pilot bore from 0 to 360 mtr
Supplying all labour, tools land plant and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer-in-Charge.
Reaming from 100 mm to 150 mm dia, 0 mtr to 360 mtr
Reaming from 150 mm to 200 mm dia, 0 mtr to 360 mtr
Reaming from 200 mm to 250 mm dia, 0 mtr to 360 mtr
Supplying all labour, tools and plant and jointing materials and lowering the 300mm dia top casing pipes into the positioin and removing the same after use all complete as per direction of Engineer-in-Charge.
Supplying all labour, tools and plant and packing the bore with washed gravel (size P-6) around the pipes in good quality excluding cost of gravel etc all complete as per the direction of the Engineer-in-charge
Supplying all labour, tools and plant and grouting with cement slurry for sanitary sealing in the bore around the upper most 3 metres of 150 mm dia PVC casing pipe properly as per the direction of the Engineer-in-Charge. (Excluding the cost of cement)
Supplying all labour, tools and plant and materials for cleaning and developing the tubewell with compressor continuously washed till clean and adequate discharge is obtained from the tube well including supply and use of necessary equipments and labour complete in all respect as per the direction of the Engineer-in-Charge.
Supplying all labour, tools and plant and jointing materials and lowering the pvc casing pipes, fittings and well screens in position including fitting and fixing of centraliser, cutter plug and washing the bore etc complete as per
the direction of the Engineer in charge
Cost of 125 mm dia casing Pipe
Cutting slots in 125mm dia Pipe
Cost of 50mm dia C.I.Cutter Plug
Cost of Bentonite powder
Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 1H.P singlr phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm
DOL Control panel
32mm dia steel short piece
Well cap
Well cap
stage.html
html • 0.09 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.42 MB
BOQ_572248.xls
BOQ • 0.45 MB
DTCN.pdf
Tender Documents • 2.36 MB
Download all tender documents and submit your bid