| 1 | L1₹21.5 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹22.5 L+₹1.1 L (5.10%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹28.1 L+₹6.7 L (31.0%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹28.6 L+₹7.2 L (33.4%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹35.1 L+₹13.6 L (63.4%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
7 May 2024, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
REPAIR/MAINT AND REPLACMENT OF PERIMETER LIGHT, TARMAC LIGHT, HIGH MAST LIGHT, STREET LIGHTS AND ALLIED ITEMS IN TECH AREA AT AF STN AMBALA UNDER GE (AF) AMBALA
2024_MES_650180_1
GE AF/ AMB-T-102/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AF AMBALA
ALL AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE AF AMBALA
₹98,000
Yes
21 Jun 2024
16 Apr 2024
9 May 2024
16 Apr 2024
7 May 2024
30 Apr 2024
Amount
M&L for taking down high pressure SV/ MV/ MH /FTL/LED street light fitting and Flood Light fittings of any wattage / any height of pole/ walls/ any location for repairs or replacement of burnt out the accessories and rectifying the fault complete all as specified and directed. Note: - LED Drivers, Surge protection and cable shall be measured and paid separately under relevant items of this schedule
S&F in replacement energy efficient LED flood light fitting, 250W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers, 250W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete all as specified and directed.
All as per BOQ srl item No.2.00 here in above but 120W complete all as specified and directed.
All as per BOQ srl item No.2.00 here in above but 70W complete all as specified and directed.
S&F in replacement energy efficient LED street light fitting, 120W, input voltage 230VAC, 50Hz with ingress protection IP 65, CRI >70, PF>0.9, minimum 25000 burning hours,LM-80, lumen efficacy ≥100 lumen/watt, THD> 20, CRCA housing including all fixing arrengment like clamps, nuts, bolts, washers, 120W LED lamp with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc. for fixing at any locations including taking down the old unserviceable fittings complete all as specified.
All as per BOQ srl item No.5.00 here in above but 90W complete all as specified and directed.
All as per BOQ srl item No.5.00 here in above but 45W complete all as specified and directed.
S&F in replacement LED high / mid-bay light fitting 120W, 230V, PF 0.9, CRI >70, L 70, with pressure die cast aluminium housing, aluminium reflectors in commercial channel with powder coated CRCA sheet housing with clear diffuser, with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with suitable size rod including taking out and disposing old fitting any type complete all as specified and as directed
S&F in replacement 5 KV SPD for LED street light, 230 volts, 50 HZ compatible for industrial & outdoor LED Fixtures up to rated power of 120 W for fixing in repairs complete all as specified and directed.
All as per BOQ srl item No.9.00 here in above but 70W complete all as specified and directed.
S&F in replacement Drivers for LED street lights 90W/120W, 230 Volts, 50 HZ complete all as specified and directed.
S&F in replacement Drivers for LED street lights 45W, 230 Volts, 50 HZ complete all as specified and directed.
S&F in replacement Drivers for LED street lights 70W, 230 Volts, 50 HZ complete all as specified and directed.
S&F in replacement Drivers for LED Flood lights 70W/120W/250W, 230 Volts, 50 HZ complete all as specified and directed.
S&F in replacement PVC insulated copper conductor cable, 3 core 1.5sqmm, served with inner sheathing of PVC tape and overall PVC sheathed, 1100V grade heavy duty in connections complete all as specified and directed.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire one twin core flat of size 6 sqmm sold aluminium conductor complete all as specified and directed.
All as per BOQ srl item No.16.00 here-in-above but of size 10 Sqmm complete all as specified and directed.
M&L for painting the swaged steel tubular LT poles including cross arms,clamps and light bracktes surface of any description after preparation of old painted surface(removing old paint by paint removers and cleaning with scraper any number of existing coats) with one finishing coat aluminium paint and marking pole no. as per existing numbers and painting of lower portion of pole in alternate layer of black and yellow shades/colour complete all as specified and directed.
S&F end joint kit in replacement for 1.1 KV grade suitable for outdoor/indoor type terminal heat shrinkable type joints with jointing material for 3.5/4 core XLPE armoured aluminium conductor cable of size 16/25 Sqmm complete all as specified and directed.
All as per BOQ srl item No.19.00 here-in-above but of cable 3.5 core 35/50Sqmm complete all as specified and directed.
S&F jointing kit in replacement kit for 1.1 KV grade suitable for straight through heat shrinkable type joints with jointing material for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 50 Sq mm complete all as specified and directed.
Supply and Laying in replacement LT underground cable XLPE insulated and sheathed armoured cable 1100 volts 4 core 16 Sqmm aluminium conductor in trenches/poles and connecting with all accessories complete all as specified and directed by Engineer-in-Charge.
All as per BOQ srl item No.22.00 here-in- above but of cable 3.5 core 25 Sqmm complete all as specified and directed.
All as per BOQ srl item No.22.00 here-in- above but of cable 3.5 core 35 Sqmm complete all as specified and directed.
All as per BOQ srl item No.22.00 here-in- above but of cable 3.5 core 50 Sqmm complete all as specified and directed.
S&F lugs for UG cable for 3.5/4 core 16Sqmm to 50Sqmm complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth/width and getting out loose/soft soil for laying of under ground cable complete all as specified and directed.
Returning/ filling in including spreading, levelling and well ramming in layers not exceeding 25cm in thick complete all as specified and directed.
Removal of surplus soil to a distance not exceeding 50m away and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 08 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushioning after punning down ie 18cm only shall be measured for payment.
Supply and lay burnt brick of size 230x115x75mm for protection of cable, laying in trenches complete all as specified and directed.
M&L for Making bore to road/cement path/hard standing for providing GI pipe 50/40mm both end socketed for passing armoured cable incl making good the disturbed surface complete all as specified and directed.
S&F in replacement security light bracket with 40mm bore GI tubing, light grade, cut and bent to shape required, 1.2m long fixed with including bends, flat iron clamp made of FI 40x6mm, nuts, bolts, washers, etc. duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specfied and as directed
S&F in replacement Integral LED aviation light comprising of aluminium housing. with polycarbonate enclosure complete all as specified and directed.
S&F in replacement Metallic ERW steel conduit 20mm dia with adaptor to 15-20 Mtr High Mast light fitting complete all as specified and directed.
M&L for repairs and maintenance of LED Solar lights with necessary maintenance of solar panel with replacement clamps and worn out leads including taking down old one complete all as specified and directed.
S&F GI tubing of 50mm dia light grade at road cross for protection cable as per site requirement and sealing the pipe both ends with sealing compound complete all as specified and directed.
All as per BOQ srl item No.37.00 here-in-above but 40mm dia complete all as specified and directed.
S&F in replacement MCCB 4P 63A 16kA 50Hz with adjustable thermal release fixed magnetic protection complete all as specified and directed.
M&L for plain cement concrete 1:2:4 (type B-1) using 20mm graded mechanically crushed stone aggregate as in coping to poles, etc. complete all as specified and as directed
M&L for plain cement concrete 1:3:6 (type C-2) using 40mm graded mechanically crushed stone aggregate as in bases to poles, stays, plinths, etc. complete all as specified and as directed
S&F in replacement automatic street light switch using timer for automatic switching of street lights, 8kW, single phase, based on LUX level of natural light, infrared sensor based on nature switch along with contactor 40A, MCB SP for input and output 63A, wiring for main load with 3 core 16sqmm copper cable duly fixed to pole/wall, mounted on enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box of protection class IP 54 fixed at any location complete all as specified and as directed
S&F in replacement automatic street light switch using timer for automatic switching of street lights, 18kW equally distributed over 3 phases, based on LUX level of natural light, infrared sensor based on nature switch along with contactor 25A/phase, MCB SP for input and output 63A, wiring for main load with 3.5 core 16sqmm copper cable duly fixed to pole/wall, mounted on enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box of protection class IP 54 fixed at any location complete all as specified and as directed
M&L for digging of cable loop of LT XPLE cable of any size with all necessary excavation and returning filling in and replacing the end joint / straight through joint kit in replacement for 1.1 kV grade with provision of jointing material for 3.5 core XLPE armoured aluminium conductor cable of any size complete all as specified and as directed Note: End/straight through joint will be measured and paid seperately under respective items herein. All other requistes shall be deemed to be included in the quoted rate
S&F in replacement junction box thermoplastic polycarbonate enclosure, shock proof, IP66/IP67 (weather, rust, dust, water and vibration proof, outdoor type, internally embedded gasket with provision for all side cable entry through glands of size 300x200x105mm with 4Nos. aluminium bus bar of size 25x6mm, 8Nos. terminals with and including 01No. 10Amp MCB 10kA duly mounted fixed with MS clamps fabricated out of FI 40x3mm of required shape and size and fied at any location complete all as specified and as directed
M&L for taking down by manual / motorised handle high mast light fittings at 15 to 20m height and refixing after necessary repairs including all necessary staging, etc. for cleaning of perplex covers, etc., tightening of loose connections on poles / walls, and replacing worn out minor parts, etc. and making the fitting functional complete all as specified and as directed Note: Quoted rate shall be deemed to be inclusive of any minor spares / parts replaced for functioning.
M&L for taking out burnt winding of 3 phase power tool electric motor of high mast fittings from any position, rewinding with super enamelled copper wire of existing size/gauge and varnishing, providing insulating paper and sleeves, etc. and testing for proper functioning on reinstating complete all as specified and as directed Note: Quoted rate shall be deemed to be inclusive of any minor spares / parts replaced for successful functionality of the motor
S&F steel wire hemp rope 8mm dia by taking out damaged rope and other minor parts suitable for high mast fittings15-20m high, like 'D' clamps, nuts, bolts, washers, etc. replacing as needed and making the installation serviceable and testing for proper functioning on reinstating complete all as specified and as directed Note: Quoted rate shall be deemed to be inclusive of any necessities, T&P, etc. required for working at 15-20m heights, etc.. cost of necessary scaffolding and security measures for labours shall be deemed to be included in the quoted rate.
M/S Sonu Traders
Esha Engineers
Raman Electric Trading Co
M/s Prakash Enterprises
kapil enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .