Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹88.4 LAccepted-AOC A P PADINJATTIL HOUSE ARUVIKKARA ROAD CHERIYAKONNI P O THIRUVANANTHAPURAM 695013 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695013 | L1 | Accepted-AOC L1 | |
| 2 | L2₹93.7 L+₹5.3 L (5.96%)Rejected-Finance BANKERS GREEN VILLA MMRA 95 01 MELETHUMELE VATTIYOORKAVU TRIVANDRUM 695013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | L2 | Rejected-Finance L2 | |
| 3 | L3₹97.3 L+₹8.9 L (10.0%)Rejected-Finance BANKERS GREEN VILLA MMRA 95 01 MELETHUMELE VATTIYOORKAVU TRIVANDRUM 695013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | L3 | Rejected-Finance L3 |
Tender Value
₹88.4 L
EMD Value
₹50,000
Closing Date
31 May 2022, 5:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy Manager (PED)
STEEL INDUSTRIALS KERALA LTD. ATHANI P.O THRISSUR- 680 581
Repair and Maintenance of High School Block and Higher Secondary Block at AMMRS Nalloornadu, Wayanad.
2022_SILK_490396_1
SILK/PED/S-003/2022-23/369
Open Tender
Miscellaneous Works
Item Rate
180 days
Nalloornadu
As per the tender documents
6 documents required · 6 mandatory
₹2,950
₹50,000
Yes
7 Nov 2022
16 May 2022
1 Jun 2022
16 May 2022
31 May 2022
16 May 2022
16 May 2022 - 31 May 2022
Amount
HIGHER SECONDARY BUILDING
15.2.2 : Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
15.52 : Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead
15.3 : Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.9.2 : Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
15.12.1 : Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
15.18 : Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,boltd, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
15.23.1 : Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
15.28.2 : Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos Sheet
14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
od56734/2021_2022 : Providing and fixing single scaffolding system on the exterior side, up to seven story height made with 40 mm dia M.S. tube, verticals and horizontals placed at 1.5 m and 1.2 m centre to centre, tube connecting wall and vericals/horizontals are pleced at 1.2m centre to centre joining with scaffold clamp system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. (Ref. : DSR 14.72 )<br>'Details of cost for area 22.5m x 9.0m = 202.5 sqm
10.12 : Extra for providing and fixing steel beading of size 10 x 10 x 1.6 mm (box type), approved shape and section with screws instead of glazing clips and metal sash putty, in steel doors, windows, ventilators and composite units.
10.30.1 : Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows all complete with :4.0 mm thick glass panes
10.31 : Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer In charge.
14.75A : Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
od56744/2021_2022 : Filling the major cracks by providing and applying approved products like Asian Paints-Smartcare Hybrid PU Sealant in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable method including cutting of nipples after curing etc. complete as per directions of Engineerin- Charge.
od56736/2021_2022 : Providing & applying one componet polyurethene, waterproofing liquid memberane on terrace. PU is applied by brush or roller in two layer. Epoxy primer should be dry and surface moisture should be less than 4% before PU application. The first layer is applied 2-3 hours after primer and while PU epoxy primer is still dried. The second layer should be applied crosswise after 8-24 hours, depending on the weather conditions. ( Epoxy primer - 200 gm per sqm and PU per coat should be 650 gm/sqm). The rate shall include all labour, material and coveyance charges etc complete.
od56737/2021_2022 : Supplying &fixing alkali resistant fiberglass mesh 110 GSM to improve elongation at failure and crack-bridging on horizontal surfaces as per the manufactures specifications. Size of mesh - 5x5 mm. Weight of raw mesh - 100 g/m2
od56738/2021_2022 : Providing & applying second layer two component acrylic polymer-modified both positive & negative side waterproofing cementitious high performance coating applied by trowel or roller for waterproofing balconies, terraces, bathrooms and swimming pools in 2 layer @26.91 kg/sqm must be applied in at first coat by brush or with a roller within 60 minutes of it being mixed, to give a final thickness of at least 2 mm. To improve elongation at failure and crack-bridging on horizontal surfaces, The first layer must be at least 1 mm thick. While it is still fresh, carefully lay on the surface, and press it in using a flat-bladed trowel to make sure that it is perfectly buttered. first coat as a primer coat @1mm thickness / 1.345kg per Sq.mtr
od56740/2021_2022 : Providing & applying first layer two component acrylic polymer-modified both positive & negative side waterproofing cementitious high performance coating applied by trowel or roller for waterproofing balconies, terraces, bathrooms and swimming pools in 4 coats @26.91 kg/sqm must be applied in at first coat by brush or with a roller within 60 minutes of it being mixed, to give a final thickness of at least 2 mm. To improve elongation at failure and crack-bridging on horizontal surfaces, The first layer must be at least 1 mm thick. While it is still fresh, carefully lay on the surface, and press it in using a flat-bladed trowel to make sure that it is perfectly buttered. first coat as a primer coat @1mm thickness / 1.345kg per Sq.mtr
26.31.1 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
od56745/2021_2022 : Preparation of surface for waterproofing. All surfaces to be plastered should be made sound, clean and dry. Concrete surfaces should have a light steel-trowel followed by a fine hair-broom or equivalent finish, which is dry and free of dust, oil and other contaminants. Sharp projection, moss and lichen must be removed physically followed by treatment with fungicidal wash to kill any spores and inhibit further growth.
15.56 : Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
22.14.1 : Grading roof for water proofing treatment with:Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
26.28.2 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge50mm average thickness
26.28.3 : Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness
26.29.1 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter
26.29.2 : Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars above 12 mm diameter
26.31.2 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
26.32.1 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).12 mm average thickness.
26.32.2 : Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).25 mm average thickness in 2 layers.
od56743/2021_2022 : Providing & applying 30mm thickness factory designed pourable,<br>non shrink, repair microconcrete , concrete should be required sufficient water drain slope,finish, complete in all respects as per drawings & specifications (excluding Steel reinforcement) including curing, machine mixing & pouring etc. complete. It should be mixed both in paddle type and slow speed grouting mixture or drum type concrete mixer. In both the cases the Microcrete is to be added to water and mix till a pourable consistency is obtained with recommended water –powder ratio as per technical data.
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
50.18.9.19.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall
50.18.9.22.4 : Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.7.1 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.50.1 : Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work (hard and soft wood)
13.50.3 : Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron /steel works
13.80 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
11.40 : Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer) of Ist quality conforming to IS: 15622 of approved make in all colours, shades, except white, Ivory, Grey Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
12.50 : Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
SCHOOL BUILDING
14.1.1 : Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
15.56 : Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
od56731/2021_2022 : Surface preparation for waterproofing. All surfaces to be waterproofed should be made a sound, clean, and dry. Concrete surfaces should have a light steel-trowel followed by a fine hair-broom or equivalent finish, which is dry and free of dust, oil and other contaminants. Sharp projection, moss, and lichen must be removed physically followed by treatment with a fungicidal wash to kill any spores and inhibit further growth. ,labour,tools, complete.
22.14.1 : Grading roof for water proofing treatment with:Cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
od56738/2021_2022 : Providing & applying second layer two component acrylic polymer-modified both positive & negative side waterproofing cementitious high performance coating applied by trowel or roller for waterproofing balconies, terraces, bathrooms and swimming pools in 2 layer @26.91 kg/sqm must be applied in at first coat by brush or with a roller within 60 minutes of it being mixed, to give a final thickness of at least 2 mm. To improve elongation at failure and crack-bridging on horizontal surfaces, The first layer must be at least 1 mm thick. While it is still fresh, carefully lay on the surface, and press it in using a flat-bladed trowel to make sure that it is perfectly buttered. first coat as a primer coat @1mm thickness / 1.345kg per Sq.mtr
od56740/2021_2022 : Providing & applying first layer two component acrylic polymer-modified both positive & negative side waterproofing cementitious high performance coating applied by trowel or roller for waterproofing balconies, terraces, bathrooms and swimming pools in 4 coats @26.91 kg/sqm must be applied in at first coat by brush or with a roller within 60 minutes of it being mixed, to give a final thickness of at least 2 mm. To improve elongation at failure and crack-bridging on horizontal surfaces, The first layer must be at least 1 mm thick. While it is still fresh, carefully lay on the surface, and press it in using a flat-bladed trowel to make sure that it is perfectly buttered. first coat as a primer coat @1mm thickness / 1.345kg per Sq.mtr
od56737/2021_2022 : Supplying &fixing alkali resistant fiberglass mesh 110 GSM to improve elongation at failure and crack-bridging on horizontal surfaces as per the manufactures specifications. Size of mesh - 5x5 mm. Weight of raw mesh - 100 g/m2
13.7.2 : 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand)
26.31.1 : Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
od56736/2021_2022 : Providing & applying one componet polyurethene, waterproofing liquid memberane on terrace. PU is applied by brush or roller in two layer. Epoxy primer should be dry and surface moisture should be less than 4% before PU application. The first layer is applied 2-3 hours after primer and while PU epoxy primer is still dried. The second layer should be applied crosswise after 8-24 hours, depending on the weather conditions. ( Epoxy primer - 200 gm per sqm and PU per coat should be 650 gm/sqm). The rate shall include all labour, material and coveyance charges etc complete.
13.88 : Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
13.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.61.1 : Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
15.7.4 : Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
6.1.1 : Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)
5.1.3 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
4.6.1 : Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), including the cost of required centering, shuttering complete.1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mm nominal size)
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od56746/2021_2022 : Providing & fixing PALRUF sheet roofing up to any pitch, including fixing with polymer-coated 'J' or 'L' hooks, bolts & nuts 8 mm dia G.I plain/ bitumen washers complete but excluding the cost of purlins, rafters, trusses, etc. The sheets shall be manufactured out of 2400 TEX panel rovings incorporating minimum 0.3% ultra-violet stabilizer in the resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866. The sheets shall be opaque or translucent, clear or pigmented, textured, or smooth as specified.<br> 2 mm thick corrugate 2.5"or 4.2" or 6") or step-down (2' or 3" or 6") as specified.
Bankers Construction
DIMEBAG SOLUTIONS PRIVATE LIMITED
Bidder Name
Bankers Construction
RAJESH N D
DIMEBAG SOLUTIONS PRIVATE LIMITED
stage.html
html • 0.05 MB
technical_704391.pdf
PDF • 0.50 MB
techsummary_704391.pdf
PDF • 0.54 MB
finance_704391.pdf
PDF • 0.43 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_704391.pdf
PDF • 0.60 MB
490396WO.PDF
PDF • 0.98 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .