Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹66.5 LAdmitted-Finance | -13.62% | ₹66.5 L | L1 | Admitted-Finance |
| 2 | L2₹67.0 LAdmitted-Finance | -13.00% | ₹67.0 L | L2 | Admitted-Finance |
| 3 | L3₹67.6 LAdmitted-Finance | -12.18% | ₹67.6 L | L3 | Admitted-Finance |
| 4 | L4₹68.0 LAdmitted-Finance | -11.69% | ₹68.0 L | L4 | Admitted-Finance |
| 5 | Not Admitted-Fee/PreQual/Technical D 5 CC COLONY DELHI 7 | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹77.0 L
EMD Value
₹1.5 L
Closing Date
13 Apr 2026, 6:00 pmClosed
GM RSRDC LTD JAIPUR
GM RSRDC LTD SETU BHAWAN, JHALANA DOONGARI, JAIPUR
Construction of safety wall and others for protection of road at Village Mayeja on SH-34, Tonk -Nagar -Nainwan-K.Patan Road District Bundi (Rajasthan)
2026_RSRDC_550059_1
RSRDCC NIT 008/2026-27 Dated 02.04.2026
Open Tender
Civil Works - Roads
60 days
Tonk -Nagar -Nainwan-K.Patan Road District Bundi
PLEASE REFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹1,180
PD RSRDC UNIT KOTA THROUGH NEFT/RTGS/IMPS
₹1.5 L
17 Apr 2026
5 Apr 2026
15 Apr 2026
5 Apr 2026
13 Apr 2026
6 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthwork in excavation of foundation structures as per drawing and technical specifications (MoRTH specification : clause No. 304) By Mechanical Means ( dewatering is required) Marshy Soil | - | Cum | - | - |
| 2 | Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500]. With 20mm nominal size aggregate P.C.C. M-15 grade Below wall | - | Cum | - | - |
| 3 | Structural cement concrete (Design Mix) in open foundations, with form work, at any level. Cement concrete for plain/reinforced concrete in open foundations as per drawing and technical specification. [MoRTH Specification : Section 1700 & 1500]. With 20mm nominal size aggregate R.C.C. M-20 grade By using concrete mixer | - | Cum | - | - |
| 4 | Providing and laying steel reinforcement at any level in foundation complete as per drawing and technical specification. [MoRTH Specification : Section 1600]. HYSD bar reinforcement | - | Tonne | - | - |
| 5 | Providing A.C. pipe Weep holes 150mm dia in Masonry/plain Concrete/Reinforced Concrete abutment, wing wall/return wall complete as per drawing and technical specification. [MoRTH Specification : Clause 2205]. | - | Nos | - | - |
| 6 | Providing & Laying of Filter media with granular Materials/stone crushed aggregates satisfying (IRC-78) the requirements laid down in clause 2504.2.2 of MoRTH specifications to a thickness of not less than 600mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification. (MoRTH specification : Clause 710, 2200, 2504). | - | Cum | - | - |
| 7 | Providing, laying and spreading and compacting specified graded crushed stone in sub-base course including premixing the Material at OMC in mechanical mixer (Pug mill), carriage of mixed Material, laying in uniform layers with Motor Grader, F.E. Loader, on a prepared surface and compacting with Vibratory Compactor to achieve the desired density including all Material, labour, machinery, lighting barricading and maintenance of Driversion complete. (MoRTH specification clause 401). with all lead & lift | - | Cum | - | - |
| 8 | Providing and laying Reinforced cement concrete pipes NP-3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (MoRTH specification : clause 1000/2900). 750 mm dia | - | Rmtr | - | - |
| 9 | Providing and fixing of Reinforced Ferro-Cement Drain cover designed of class "A" & "AA" loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti-corrosive bitumen painted M.S. plate, Rim and on M.S. lifting hooks, admixture like plasticizer bond-improving compound, shrinkage resistance compound, abrasion resistant complete as per approved design etc.Span 1201 mm to 1500 mm Standard Size 2100 x 500 mm | - | Sqm | - | - |
| 10 | Provinding and laying of paver block as per IS 15658 : 2006 (Indian standerd for Precast concrete block for Paving -specification) and IRC :SP:63-2004(guidelines for the use of interlocking concrete blockPavement) (from BIS approved manufactrers M-40,80mm thick to be used in medium-traffic (Medium trafficis defind as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight , or an equivalent of 0.5 to 2.0 MSA for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc. Category 'B' denated only two side like I,Z,T shape etc. as per IRC SP 63:2004 including over if reflective paver block, manufactured with wet cast vibration system in two layers is used. including over if colored paver blocks are used | - | Sqm | - | - |
stage.html
html • 0.03 MB
technical_980577.pdf
techsummary_980577.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.28 MB
various_Circulars_Office_Orders.pdf
Tender Documents • 0.32 MB
agrement.pdf
Tender Documents • 0.45 MB
AnnexureABCD_RTPPAct2012_AnnexureC.pdf
Tender Documents • 0.10 MB
bankdetails.pdf
Tender Documents • 0.26 MB
BOQ_980577.xls
BOQ • 0.28 MB
spltc.pdf
Tender Documents • 0.23 MB
Download all tender documents and submit your bid