Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC TC 25664 RAJI OPP HOTEL AMRITHA THYCAUD THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.1 L+₹22,000.40 (4.52%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | Seven Seas Infotech Systems L1 | sudeesh babu v s L2 |
|---|---|---|---|---|---|
| 1.00SITC of AC | |||||
| 1.00 | OD244233/2025-2026:Supplying, installation, testing and commissioning of 1 TR and ISEER value grater than or equal to 5 rated inverter type split air conditioner unit complying to IS 1391: 1992 (Part 1 & II) with up-to-date amendments complete with indoor unit, outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410/R32 refrigerant gas. 230V.50 Hz. single phase AC supply, capable of performing- a. Cooling b. Dehumidifying. Air Circulating. d. Filtering including providing wireless remote control unit. 3 metre copper refrigerant piping, wiring, drain pipe suitable size Indoor and outdoor unit stand for condensate drain water all insulated with nitrile tubing from indoor unit complete. Make :- Hitachi/Daikin/ MITSUBISHI/ Blue star/carrier | 6 | each | 50,000 ₹3,00,000 Lowest | 51,315 ₹3,07,890 |
| 1.00 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top | 6 | each | 100 ₹600 Lowest | 125 ₹750 |
| 1.00 | 90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm | 70 | metre | 100 ₹7,000 Lowest | 113 ₹7,910 |
| 1.00 | OD244232/2025-2026:Supply and fixing of 25mm 10Kg/cm2 PVC drain water pipe line with necessary,supports, saddles,clamps, hangers, and fittings such as bends, tees etc and insulated the entire length of the pipe with 19/25 mm Nitrile or Rubber insulation and covered by a 120 G/nearest size polythene sheet ( max-5cm width) as cladding complete with type as per specifications and as required., all complete as per direction of Engineer-in-Charge | 70 | metre | 90 ₹6,300 Lowest | 94 ₹6,580 |
| 1.00 | OD244264/2025-2026:
Supply, and fixing of 5/8" +3/8" Refrigerant Copper Piping size in brazed construction having minimum 22 SWG gauge, including suitable rated elbows and other necessary fittings etc for interconnecting the air conditioning indoor and outdoor units and including insulated with minimum 9 mm thick insulation chemically cross linked closed cell Nitrile rubber tube insulation with mechanical protection coating/layer, duly clamped on wall /ceiling or and supported on GI perforated cable tray as per the drawing and site conditions for connection between outdoor and indoor units. | 64.7 | metre | 1,650 ₹1,06,755 Lowest | 1,722 ₹1,11,413.4 |
| 1.01 | OD244234/2025-2026:Charges for filling sufficient quantity of Refrigerant 410A gas for existing air conditioner unit including leak testing rectifying the defects leak arresting including breezing and make the compressor in good working condition for the following. 1TR/2TR/3TR AC unit | 14 | kg | 1,100 ₹15,400 Lowest | 1,330 ₹18,620 |
| 1.01 | OD244262/2025-2026:Supply,Installation, Testing and commissioning of Drain Pump | 6 | each | 3,500 ₹21,000 Lowest | 3,799 ₹22,794 |
| 1.01 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm | 75 | metre | 150 ₹11,250 Lowest | 161 ₹12,075 |
| 1.01 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm | 70 | metre | 140 ₹9,800 Lowest | 151 ₹10,570 |
Tender Value
₹5.1 L
EMD Value
₹12,710
Closing Date
23 Feb 2026, 6:00 pmClosed
AEE
PWD Electrical Sub Division Tvpm
DEPOSIT-SITC of Air Conditioning units in Memebers/Secretaries rooms at Pravaasi Bharatheeyar Commission office, 6th floor NORKA centre, Thycaud, THIRUVANANTHAPURAM-AC UNITS-Electrical AC Work
2026_PWD_836651_1
ESDT/ET-258/2025-26
Open Tender
Electrical Works
Item Rate
90 days
PWD Electrical Sub Division Tvpm
please refer tender documents
5 documents required · 5 mandatory
₹1,125
₹12,710
Yes
21 May 2026
16 Feb 2026
25 Feb 2026
16 Feb 2026
23 Feb 2026
16 Feb 2026
SITC of AC
OD244233/2025-2026:Supplying, installation, testing and commissioning of 1 TR and ISEER value grater than or equal to 5 rated inverter type split air conditioner unit complying to IS 1391: 1992 (Part 1 & II) with up-to-date amendments complete with indoor unit, outdoor unit (condenser and evaporator coil shall be of copper) etc. and operating on R410/R32 refrigerant gas. 230V.50 Hz. single phase AC supply, capable of performing- a. Cooling b. Dehumidifying. Air Circulating. d. Filtering including providing wireless remote control unit. 3 metre copper refrigerant piping, wiring, drain pipe suitable size Indoor and outdoor unit stand for condensate drain water all insulated with nitrile tubing from indoor unit complete. Make :- Hitachi/Daikin/ MITSUBISHI/ Blue star/carrier
90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
OD244232/2025-2026:Supply and fixing of 25mm 10Kg/cm2 PVC drain water pipe line with necessary,supports, saddles,clamps, hangers, and fittings such as bends, tees etc and insulated the entire length of the pipe with 19/25 mm Nitrile or Rubber insulation and covered by a 120 G/nearest size polythene sheet ( max-5cm width) as cladding complete with type as per specifications and as required., all complete as per direction of Engineer-in-Charge
OD244264/2025-2026: Supply, and fixing of 5/8" +3/8" Refrigerant Copper Piping size in brazed construction having minimum 22 SWG gauge, including suitable rated elbows and other necessary fittings etc for interconnecting the air conditioning indoor and outdoor units and including insulated with minimum 9 mm thick insulation chemically cross linked closed cell Nitrile rubber tube insulation with mechanical protection coating/layer, duly clamped on wall /ceiling or and supported on GI perforated cable tray as per the drawing and site conditions for connection between outdoor and indoor units.
OD244234/2025-2026:Charges for filling sufficient quantity of Refrigerant 410A gas for existing air conditioner unit including leak testing rectifying the defects leak arresting including breezing and make the compressor in good working condition for the following. 1TR/2TR/3TR AC unit
OD244262/2025-2026:Supply,Installation, Testing and commissioning of Drain Pump
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1408584.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewsbd.pdf
Additional Documents • 1.63 MB
Specificondtionsac-1.pdf
Additional Documents • 0.08 MB
BOQ_1408584.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .