Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.8 LAccepted-AOC EKTA ENCLAVE PHASE 1 SEWLA KALAN CHANDERBANI ROAD DEHRADUN U K PIN 248171 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248171 | L1 | Accepted-AOC Acceptance of Contract | |
| 2 | L2₹44.8 L+₹5.0 L (12.6%)Rejected-AOC 36A 60 CIVIL LINE TELIYAR GANJ ALLAHABAD UTTAR PRADESH 211004 | PRAYAGRAJ | UTTAR PRADESH | 211004 | L2 | Rejected-AOC OK | |
| 3 | L3₹46.7 L+₹6.9 L (17.5%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹48.6 L+₹8.8 L (22.1%)Rejected-AOC 381 2 SATYA VIHAR MANDIR MARG VIJAY PARK DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC OK | |
| 5 | L5₹49.2 L+₹9.4 L (23.7%)Rejected-AOC 107 NEAR POST OFFICE PRENAGAR DEHRADUN 248 007 UK | DEHRADUN | UTTARAKHAND | 248007 | L5 | Rejected-AOC OK |
Tender Value
₹49.5 L
EMD Value
₹99,400
Closing Date
14 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
PROVN OF CERTAIN REVENUE WORK AT IMA DEHRADUN
2024_MES_654655_1
GE/IMA/T-41 of 2024-2025 9430/E8
Open Tender
Support/Maintenance Service
Item Wise
180 days
GE IMA Dehradun
Refer NIT
6 documents required · 6 mandatory
₹500
Yes
GE IMA Dehradun
₹99,400
Yes
3 Sept 2024
17 May 2024
17 Jun 2024
18 May 2024
14 Jun 2024
7 Jun 2024
Amount
Surface Excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil all as specified and directed.
M&L for 100 mm thick PCC 1:2:4 type B-2 (using 40mm graded crushed stone aggregate) as in sub base floor/floors and paving etc complete all as specified.
M&L for hardcore of guage exc 63mm but n exc. 100 mm, deposited,spread and levelled in layers n exc. 15 cm thick of broken stone or boulders, watered & rolled to true surface
M&L for 150mm thick PCC 1:2:4 type B-2 (using 20mm graded crushed stone aggregate) as in sub base finished even including spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green complete all as specified.
M&L for Providing, cement concrete 1:2:4 type B-O (using 12.50 mm graded crushed stone agg) in roof kerbs or mud stops, rounded or chamfered on edges
M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ Thickness of concrete slab in 150 mm
M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A complete all as specified.
Excavation in post holes (or similar holes) each n.exc 0.5 Cum getting, complete all as specified and directed.
Excavation in trenches n.exc 1.5 wide and n.exc 1.5m depth for foundation or for shaft etc n.exc 10sqm on plan and n.exc 1.50m in depth and getting out in soft/loose soil complete all as specified & directed.
Returning filling in with excavated soil including spreading levelling, watering and well ramming in layers not exc. 25cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material exc 500m but n.exc 1.5km and depositing where directed at a level n.exc 1.5m above the starting point.
M & L for PCC 1:5:10 type E-2 (using 40mm graded crushed stone aggregate) as in sub base filling and mass concrete complete finished even and fair all as specified and directed.
M & L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete etc for post,column, complete all as specified and directed.
M & L for machine cut Kota stone 18 to 20 mm thick laid and jointed with grey cement slurry and pointed in grout to match the shade of the slab including rubbing and mirror polishing complete up to desired finish over & including 20mm thick screed bed in cement mortar 1:6.
S&F 4 mm thick E-board false ceiling (Classic) including galvanised colour coated snap grid frame for false ceiling, size of grid 605 X 605 mm fixed with 1.6 mm dia GI wire suspenders one end tied to roof members and other end connected to main tee of grid framework by means of 4mm dia adjustable "J" hook consisting of two Nos washers and two nuts at 1.2 mtr centres all as specified and as directed by Engineer-in charge (size of main tee 38 mmX25 mmX 1.4 mm, cross tee 38 mm X 25 mm X 1.4 mm angle along walls 38 mm X 25 mm X 2.0 mm) and two coats of oil bound emulsion complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C-1(using 20mm graded crushed stone aggregate) as in plinth protection/ Path finished even and smooth without using extra cement including cutting 10mm grooves to full depth at an interval of 3m and at all corners & filling the same with sealing compoung grade 'A' complete all as specified.
S & F Rolled MS in joists, Channel, angle or TEE sections fixed independently without connecting plates complete all as specified and directed conforming to Fe-290 Gde E-165. Make:- Tata steel, JSW steel, Appolo steel.
S & F MS angle/TEE/Hollow/tubular section as in main and cross beams, hips, and jack rafter, purlins , doors ets where connected to common rafters and etc. all as directed by Engineer-In-Charge conforming to Fe-290 Gde E-165. Make:- Tata steel, JSW steel, Appolo steel.
M & L for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment Fe-290 (Gde E-165)
S&F for Welded steel wire fabric supplied and fixed complete to wood or steel members
S & F pre-painted galvalume aluminium zinc coating GI based AZ-150 grade corrugatged steel sheet 0.50mm thick any colour having tensile strength of 550 Mpa and 150 GSM as in roof covering/cladding to wall fixed with self tapping screws as specified.
S & F pre-painted galvalume aluminium zinc coating GI based AZ-150 grade Plain steel sheet 0.50mm thick any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.(sheet when used in ridges shall be pre profiled to match with roof sheet)
M & L for preparation of new or previously untreated steel surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M & L for brick work with sub class "B" bricks in cement mortar 1:6 straight or curved on plan exc 6.00m mean radius with old size bricks complete all as specified and directed.
M & L two coats of cement based paint on newly plastered surface over a coat of suitable primer including all preparation complete all as specified and directed.
M&L for 100 mm thick PCC 1:4: 8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of floor complete all as specified.
M&L for rubberised precast concrete interlocking paver block with grey cement and pigment any shape and size made by table vibratory method using PU mould of 80 mm thickness, M-35 Grade complete all as specified and directed. Make:- Tulip Infrastructure, Jain tiles Haldwani, NTC Panchkula.
M&L for sand filling 30mm under floor or in foundation including conslidation under interlocking paver block all as directed.
Removing excavated (soil) material out side IMA premises and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for 15mm thick ready mix cement plaster on brick, concrete surfaces and Ceiling surface finished even and smooth complete all as specified and directed. Make : ACC (Suraksha)/Ultratech (Readyplast)/Birla (Aerocom)/Unicrete.
M&L for Preparation of surface of wall / ceilling by mechanical sander/ scraper and applying 1mm to 1.5mm thick acrylic damp proof wall care putty as per manufacturer instruction complete all as specified and directed.
M&L for Preparation of surfaces of puttied wall / ceiling by and applying two coats of oil bound emulsion distemper over a coat of primer complete all as specified and directed. Note : 1. The work shall be executed from authorized applicator only as approved by GE. 2. After completion of distempering, contractor have to carry out following work whose rates to be included while quoting the rates. No extra payment will be done on this account and damage if any to be borne by the contractor. (i) cleaning of floor with floor cleaner and stain should be removed from wall/door/jaali. (ii) cleaning of curtain rod. (iv) shifting of furniture.
M&L for Preparation of wall/ ceiling surfaces of puttied wall / ceiling and applying two coats of weather coat exterior paint over a coat of primer over 1mm to 1.5mm thick acrylic damp proof wall care putty complete all as specified and directed (work to be carried upto a height of 7.5m). Note : The work shall be executed from authorized applicator as approved by GE.
M&L for Non skid ceramic coloured tiles 8 to 9mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in tile grout to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in cement mortar 1:6 including dismantling floor hearth or wall tiling including cement mortar bedding, complete all as directed. Note :- Colour & pattern as approved by GE.
M&L for Vitrified ceramic coloured tiles 7 to 8mm thick (Square or rectangular) polished, area of each tile n exceeding 0.36 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in tile grout to match the shade of tiles laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 including dismantling floor hearth or wall tiling including cement mortar bedding complete all as specified and directed. Note :- Colour & pattern as approved by GE.
S&F aluminium powder coated door fixed on aluminium frame of section 47.62mm x 44.45x1.6 mm thick, shutter glazed with tinted glass (Modi Guard) 5mm thick fixed with rubber gasket and aluminium strips as per standard method also rubber gasket at frame so as to make air tight with cast type handle aluminium anodised of 150mm size 2 Nos (One on each side of shutter) with shutter bottom rail 150mm x 44.45mm x1.6mm thick section, middle and top rail 83.5mm x 44.45mm x 1.6 mm thick section, side style 83.5mm x 44.45mm x 1.6 mm thick section all as per IS 737- 1986 fixed with aluminium (extruded section) hydraulic door closer regulated designation No-3 universal type and make with aluminium tower bolt arrangement of standard make with locking arrangement with 6 levers mortise lock(brass body) of size 100mm including butt hinges, door stopper etc complete all as specified and directed.
M&L for aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one Nos wire gauged shutter sliding type, with aluminum sections as per Series-B (18mm) 3 track of Jindal section numbers for sliding windows, and glazed with and including tinted glass 6mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type 2 Nos aluminium handle of size 75mm and locking system including aluminium grill of 5mm thick, average width of aperture 50mm and SS wire cloth 0.46mm dia of wire and 1.40 aperture and provision of space for AC etc complete all as specified and directed. Shutter Top & bottom size : 52.00 X 18mm X 1.45mm Section No 20737 Shutter inner lock size : 40.00 X 18mm X 1.55mm Section No 20736 Chowkhat bottom/ Top size : 92.00 X 31.75mm X 1.50mm Section No 20832 Chowkhat both sides size: 92.00X31.75mm X 1.50mm Section No 20831
S&F aluminium powder coated frame for fixed partition of section 47.62mm x 44.45x1.6 mm thick, shutter glazed with tinted glass (Modi Guard) 5mm thick fixed with rubber gasket and aluminium strips as per standard method also rubber gasket at frame so as to make air tight all as per IS 737-1986 complete all as specified and directed.
M&L for PCC 1:2:4 Type B-1 (using 20mm graded crushed stone aggregate) as in coping/benching including weathering, slightly rounded or chamfered angles and throating etc including necessary form work complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone agg) as in foundation, filling, mass concrete and sub base of floor complete all as specified and directed
M&L for heavy duty precast prepolished coloured cement concrete cobble stones paver block of size 100x100mm and 80 mm thickness of M-35 grade of fiber reinforced concrete (FRC) with approved colour, design and pattern, thickness & size / shape made by table vibratory method using rubber mould with strong vibratory compaction complete, all as specified and directed. Make:- Tulip Infrastructure, Jain tiles Haldwani, NTC Panchkula.
M&L for 20 mm thick Screed bed or bedding layer in cement mortar 1:6 for laying floor finishes complete, all as specified and directed.
M&L for Precast cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in kerb stones (road side edges) and the like of required shape and as in coping/benching including weathering slightly rounded or chamfered angles complete all as specified
Material and labour for point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in non rigid PVC Conduit fixed on surface of wall not less than 25 mm dia with all fitting and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including modular PVC l flush box and modular cover and frame for mounting modular switch, regulators etc complete for the following. Make of wire:- Havells, Polycab, Grandlay, SCI Make of conduit :- AKG, Polycab, Bhagwati plastic & Agriculture Ind. Note: Point wiring & earth wire shall be connected to each & every sunken box.
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No.44 above but with stranded copper conductor 2.5 Sq mm (nominal area), two single core, PVC insulated cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
Supply and fix modular switch 1 way 6A, 1 Module Make:- Legrand, Havells (Brand crabtree),Anchor
Supply and fix modular switch 1 way 16A, 1 Module with indicator lamp Make:- Legrand, Havells (Brand crabtree),Anchor
Supply and fix modular socket 6A, 2/3 pin combined 2 Module Make:- Legrand, Havells (Brand crabtree),Anchor
Supply and fix modular socket 6A/16A, 2/3 pin combined 2 Module Make:- Legrand, Havells (Brand crabtree),Anchor
Material and labour for ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed. Make: Anchor, Crab tree, SSK.
Supply and Fix LED batten light fitting 4 feet of lumens 2500 lumens, wall mounted ,high pressure die cast alluminium, fully diffused ,system efficacy 125L/W ,polycarbonated diffuser,IP-20 ,high bright LED lamp, colour temp not less than 5700 Cool Day Light,colour rending index not less than 80 ,life not less than 20000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 10 % with operating voltage 140-270V AC, 50 Hz, surge protection minimum 2.5KV including,connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed . Make: - PHILIPS /CROMPTON/HAVELLS.
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm thick GI wire by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to main switch board,including all necessary excavation & earth work in hard dense soill including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternate layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle and necessary testing complete all as shown in electrical plate No 3 of SSR part-I (2009) all as specified and directed.(one earthing for each DBl )
S and F sheet metal enclosure double door type ISI marked MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar all as specified and directed. Make:- Havells, Indo Asian, HPL.
S and F 240 Volts ,10KA” B” curve miniature circuit breaker (MCB SP) of single pole and current carrying capacity 6 to 32 A in the MCB DB complete with connection testing and commissioning all as specified and directed. Make:- Havells, Indo Asian, HPL.
S and F 240 Volts ,10KA” B” curve miniature circuit breaker (MCB SPN) of single pole and current carrying capacity 40 TO 63 A in the MCB DB complete with connection testing and commissioning all as specified and directed. Make:- Havells, Indo Asian, HPL.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) Make:- Havells, Crompton, Khaitan.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core in 50 mm dia LDPE pipe in trench up 45 cm depth all as specified and directed Make:- Havells, Polycab, Grandlay, SCI
Supply and Fix LED batten light fitting 2 feet of lumens 1000 lumens, wall mounted ,high pressure die cast alluminium, fully diffused ,system efficacy 100L/W ,polycarbonated diffuser,IP-20 ,high bright LED lamp, colour temp not less than 5700 Cool Day Light,colour rending index not less than 80 ,life not less than 20000 hrs, inbuilt electronic driver, PF not less than 0.90 and THD less than 10 % with operating voltage 140-270V AC, 50 Hz, surge protection minimum 2.5KV including,connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose complete all as specified and directed . Make: - PHILIPS /CROMPTON/HAVELLS.
S & F in repair wall mounted Fan 400mm sweep ,2100 RPM high speed and 105CMM Air Delivery,strudy base and thermal overload protection ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, etc i complete all as specified and directed. Make : BAJAJ/HAVELLS /Crompton
PRAGATI ENTERPRISES
M/s RAM RATAN AND SONS
Aron Water Proofing and Pest Control
M/s Vinod Singh Negi
M/S RAJESH KUMAR GOYAL
M/s RK ENTERPRISES
M/S S P BUILDERS
Meher enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .