Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.4 LAccepted-AOC P O P S UDALGURI WARD NO 2 DIST UDALGURI BTC ASSAM | UDALGURI | ASSAM | 784113 | L1 | Accepted-AOC L1 | |
| 2 | L2₹89.5 L+₹5,000 (0.06%)Rejected-AOC ASSAM AS | LAKHIMPUR | ASSAM | 784160 | L2 | Rejected-AOC L2 |
Tender Value
₹89.4 L
EMD Value
₹1.8 L
Closing Date
3 Dec 2022, 3:00 pmClosed
The S.E, PWD, Kokrajhar, Bldg, Circle
O/o the S.E, PWD, Kokrajhar, Bldg, Circle, Kokrajhar
Installation of Medical Gas Pipeline for 50 beds to make Oxygen supported bed in addition to their existing facility at Udalguri Civil Hospital in Udalguri District Pkg No.510_1
2022_BoTC_27795_1
No. TECH- 05/SE(B)/E-Tender/2021-22/49
Open Tender
Civil Works - Building
Item Rate
180 days
Udalguri
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,800
₹1.8 L
Yes
22 Dec 2022
17 Nov 2022
3 Dec 2022
17 Nov 2022
3 Dec 2022
17 Nov 2022
17 Nov 2022 - 3 Dec 2022
Amount
(A) Cost of MGPS Works: Supplying, Installation, Testing & Commission of Terminal Units ( Oxygen/Air/Vaccum Gas Outlets) with probes/Adaptors as per CE certified/ISO certified Organization.
Supplying, Installation, Testing & Commission of Oxygen flow meter, made with chrome plate brass body. Graduated flow tube anf cover made of polycarbonate unbreakable. Adjustable flow by needle valve knowb with micrometrical regulation. Humidifier bottle is made of unbreakable polycarbonate materials and is autoclavable.
Supplying, Installation, Testing & Commissioning of Ward Vaccum with Regulator alongwith vacuum gauge, Collection Jar of 600ml capacity reusable collection bottle with overflow safety tap wall mounted type with bracket co,plete all as specified and as directed.
Supplying fitting ad fixing of copper pipe solid drawn, seamless, deoxidized , non-arsenical, half-hard, temper and de-greased copper pipe comforming to latest BS EN 13348:2001 and manufactured as per BS: 2871, 1917 part-I Table X ( or as per EN1057). All copper pipe will be degreased and delivered capped at both ends. 4.1 12mm od x 0.7mm thickness
Supplying fitting ad fixing of copper pipe solid drawn, seamless, deoxidized , non-arsenical, half-hard, temper and de-greased copper pipe comforming to latest BS EN 13348:2001 and manufactured as per BS: 2871, 1917 part-I Table X ( or as per EN1057). All copper pipe will be degreased and delivered capped at both ends. 4.2 15mm od x 0.9mm thickness
Supplying fitting ad fixing of copper pipe solid drawn, seamless, deoxidized , non-arsenical, half-hard, temper and de-greased copper pipe comforming to latest BS EN 13348:2001 and manufactured as per BS: 2871, 1917 part-I Table X ( or as per EN1057). All copper pipe will be degreased and delivered capped at both ends. 4.3 22mm od x 0.9mm thickness
Supplying fitting ad fixing of copper pipe solid drawn, seamless, deoxidized , non-arsenical, half-hard, temper and de-greased copper pipe comforming to latest BS EN 13348:2001 and manufactured as per BS: 2871, 1917 part-I Table X ( or as per EN1057). All copper pipe will be degreased and delivered capped at both ends. 4.4 28mm od x 0.9mm thickness
Supplying fitting ad fixing of copper pipe solid drawn, seamless, deoxidized , non-arsenical, half-hard, temper and de-greased copper pipe comforming to latest BS EN 13348:2001 and manufactured as per BS: 2871, 1917 part-I Table X ( or as per EN1057). All copper pipe will be degreased and delivered capped at both ends. 4.5 35mm od x 1.2mm thickness
Supply and installation, Testing and commissioning of isolation valve with brass body nickel plate valven operating handle suitable for 12mm OD copper pipe to 42mm OD copper pipe with brass adapter as per standard specification and as pwe ISO 9001: 2015 & with digit CE mark and as directed for the following isolation valves. 15mm od x 0.7mm thickness
Supply and installation, Testing and commissioning of isolation valve with brass body nickel plate valven operating handle suitable for 12mm OD copper pipe to 42mm OD copper pipe with brass adapter as per standard specification and as pwe ISO 9001: 2015 & with digit CE mark and as directed for the following isolation valves. 22mm od x 0.7mm thickness
Supply and installation, Testing and commissioning of isolation valve with brass body nickel plate valven operating handle suitable for 12mm OD copper pipe to 42mm OD copper pipe with brass adapter as per standard specification and as pwe ISO 9001: 2015 & with digit CE mark and as directed for the following isolation valves. 28mm od x 0.9mm thick
(B) Cost of Electrical Works: Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.4Above 185 sq. mm and upto 400 sq. mm
Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required 11.1.3 Above 8.0 metre and upto 11.0 metre
G.I. Pipes 80mm dia
Supply of following size PVC/XLPE insulated and PVC sheathed 1.1 kv gd solid aluminium conductor upto 10 sqmm, balanced stranded conductor, XLPE insulated, cores laid up, PVC tape innersheathed, armour ( aluminium wire for single core up to 70 sqmm, balanced aluminium strip. Galvanised wire for cables upto 2 x 10 sqmm, 3 x10 sqmm, 4 x 6 sqmm and balanced all galvanised steel strip), extruded PVC type ST2 sheathed. 650/1100 v grade as per IS 7908 (part I) 1988 armoured UG cable as specified asnd directed by the deptt. (polycab. RR, or equivalent make as approved by this deptt.) 300.00 sqmm 3.5 core
Supplying, installation, testing and commissioning of the 250 KVA, 11/0.433 KV copper wound outdoor tyoe oil filled 4-STAR Level -2 transformer complete including all accessories like earthing therminal lifting lugs,drain valve, oil filling hole with plug, silicagel breather, First filling of oil as per IS 355, arcing hom Radiator . AQn release plug, conservator tank etc along with cost of load security, Meter security and making necessary arrangement of obtainning NOC for charging approval of the sub station from competent authority as directed and specified by the Department. Transformer should as per CEA guidelines as ammended upto date ( All required materials for the sub station will be measured and paid separately).
Supply, testing commission of 9.75 mtr PSC pole as per direction of the department.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required
Supplying and erection of 11 KV pin insulator complete with lange steel head G.I. Pin, nuts, washer etc. As required
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required
Erection of disc/ pin insulator for 11 KV over head lines as required.
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supplying including installation, commissioning of 11 KV CT/PT, 11 KV Energy Meter Cabinet, Supervision Charge to be to APDCL etc. (As per APDCL Estimate)
Payment of load Security of 120 KW ( As per APDCL )
Supplying including installation, teasting and commissioning of Wter Coolef Diesel Generator set coupled complies with current CPCB-II emission norms to suitable alternator of 220/415 V, AC, 1/3 Phase 0.8 p.f. Mounted on a I ) M.S. Fabricated base frame, 2) M.S. fuel tank of required capacity, 3 ) Residual silencer (stack height shall be minimum 6.0 mtrs above the building where the gen set is installed ) 4) AMF Control panel .5) Suitable batteries with lead, 5) First fill of lube oil, 6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the technical specification as per manufacturer. ( Range FROM 5 KVA TO 625 KVA. Kirloskar KOEL, 250 KVA Water Cooled Ciesel Generator set with AME panel.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 A, 16 KA,TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 250 A,50KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 400 A,50KA,FPMCCB
Supplying and fitting, fixing of 11KV DO fuse 150A, 11KV GOAB Switch 400 Amps (as per ASEB's Rate) (item no. 20)
Supplying including fitting fixing 11KV XLPE insulated ABC 3CX120 sqmm + 1CX95 sqmm
Supplying including fitting fixing 11KV XLPE insulated ABC 3CX150 sqmm + 1CX120 sqmm
Supplying including fitting fixing of 400A changrover switch in outder panel board
(C) Cost of Generator & Transformer Shed: Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 11.1.2 1:6 (1cement : 6 coarse sand)
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.4 Hot rolled deformed bars
FORM WORK Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9.3 Suspended floors, roofs, landings, balconies and access platform
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
15 mm cement plaster on the rough side of single or half brick wall ofmix : 13.2.1 1:4 (1 cement: 4 fine sand)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes kg 154.90
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required
SRI PRANAB BARMAN
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .