Loading…
Loading…
Tender Value
₹5.5 L
EMD Value
₹5,500
Closing Date
10 Aug 2026, 4:00 pmClosed
DEPUTY EXECUTIVE ENGINEER, PATAN ELECTRICAL (R&B) SUB DIVISION, PATAN
Repairs to Street Light and Street Light Cable in Court Building Santalpur, Varahi, Dist. Patan.
328128
04/01 OF 2026/2027
Open
Electrical
Works
Patan
7 documents required · 7 mandatory
₹900
Executive Engineer, Mehsana Electrical (R&B) Division, Mehsana
₹5,500
28 Jul 2026
28 Jul 2026
28 Jul 2026
10 Aug 2026
28 Jul 2026
Name of Work:- Repairs to Street Light and Street Light Cable in Court Building Santalpur,
Varahi, Dist. Patan.
Quanti Rate at which the materials will
SR Perticulars Place of delivery
ty be charged to the contractor
( Signature of Contractor ) Deputy Executive Engineer
Patan Electrical Sub Division
Name of Work:- Repairs to Street Light and Street Light Cable in Court Building Santalpur, Varahi, Dist. Patan.
Item Qty. Unit Net Rate Amount
1 Replacing old & U/S by New Supplying and erecting Flexible PVC
insulated multi strand multi core 1.1 kv grade ISI marked copper
wires of following size to be erected as directed..e).1.50 Sq.mm 3 50 Mtr 46.46 Six And Paise
core round PVC sheathed (RR KABEL, FINOLEX, ANCHOR, Forty Six Only
HAVELLS, POLYCAB, KEI)
2 Replacing old & U/S by New Supplying and erecting LED street
light / Flood light fittings with High power White LEDs wattage of
3 Watt and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and heat
sink extruded aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company mark/name Rupees Three
engraved or embossed 160 to 270 V,Power Factor more than Thousand
0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Three Hundred
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 Forty Five And
%.( fittings required LM-79 & LM-80 certificates)(NOTE: Below Paise Twelve
description have shown ranges of Wattage capacity of LED Only
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.) (A) Street Light (IP-65), Surge
protection -4KV integral and ,Light must have 440VAC line supply
with over-voltage protection. (i) above 36 to 48 watts Cat.III
(PHILIPS, CROMPTON, JAQUAR, HAVELLS, LUKER, HALONIX)
(B) Flood Light (IP-65), Surge protection -4KV integral and ,Light Rupees Six
must have 440VAC line supply with over-voltage protection. Thousand
(iii) 90 watts Cat-lll (PHILIPS, CROMPTON, JAQUAR, Eighty Eight
HAVELLS, LUKER, HALONIX)
3 providing and erecting Miniature circuit breaker single pole 0.5A Rupees Two
to 2A system and having breaking capacity 10 KA to be erected in Hundred
existing box. confirming to IS 8828/1996 with ISI Mark 19 Nos 270.68 Seventy And
Cat.III (L & T, INDOASIAN, SWITCHER, HAVELLS,ABB, LEGRAND, C Paise Sixty
4 providing and erecting Miniature circuit breaker single pole 6A to
25A suitable to operate on 240 V A.C. system and having breaking
capacity 10 KA to be erected in existing box. confirming to IS 8 Nos 112.11 Twelve And
8828/1996 with ISI Mark Cat. III (L & T, INDOASIAN, SWITCHER, Paise Eleven
HAVELLS,ABB, LEGRAND, C & S) Only
5 Replacing old & U/S by New Providing , erecting , fabricating the
M.S. structure as per requirement on site incorporating proper
size of M.S. angles,square,round, flats, bars, channels, sections Seventy Seven
complete with cutting, welding, grinding & finishing duly painted 16 Kg. 77.77 And Paise
with one coat of red oxide with erection on site as per direction Seventy Seven
of engineer in charge with necessary grouting, cementing, Only
plastering & finishing complete.
6 Replacing old & U/S by New Providing and erecting XLPE
(IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with necessary clamps or 1060 Mtr 126.25 Twenty Six And
in existing trench / pipe of following size of cables(B) 4 core 6 Sq. Paise Twenty
mm (RR KABEL, FINOLEX,AVOCAB, ANCHOR, HAVELLS, Five Only
POLYCAB, KEI,ADCAB)
7 Providing & laying approved make Double walled corrugated
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required 780 mtr 62.62 Two And Paise
depth in existing trench for laying of cable. below ground / road Sixty Two Only
surface for enclosing cable (A)50 mm outer dia
8 Making trench in soft soil of suitable width of 90 cm deep for
laying cable or locating the fault all over the run and back filling Rupees Fifty
the same and making the surface as normal ground. 320 Mtr 55.55 Five And Paise
Fifty Five Only
9 Drilling the road without breaking the road surface (Asphalt) for Rupees Four
laying of cable for feeding power supply by making up to Hundred
following size of holes at both ends complete..(A) Up to 100 mm Ninety Two
bore dia And Paise
10 Making trench in Hard Murrum / Tar Road of suitable width of
cm or required depth for laying any size of cable or locating the Rupees Four
fault all over the run and back filling the same and making the Hundred Thirty
340 Mtr 432.28 Two And Paise
surface as normal ground. (B) If additional machinery like
hammer driller or JCB use [Add]
11 Replacing old & U/S by New Providing , erecting , fabricating the
M.S. structure as per requirement on site incorporating proper
size of M.S. angles,square,round, flats, bars, channels, sections Seventy Seven
complete with cutting, welding, grinding & finishing duly painted 24 Kg. 77.77 And Paise
with one coat of red oxide with erection on site as per direction Seventy Seven
of engineer in charge with necessary grouting, cementing, Only
plastering & finishing complete.
12 Providing and, fixing heavy duty flange type brass cable gland Rupees Thirty
with rubber ring for PVC insulated armoured cable complete with Eight And
out going tails, insulating tape etc for following size of cables. (B) 16 Nos 38.38
2 to 4 core 6 Sq. mm Eight Only
13 Solder less crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high Rupees Six And
pressure tool & connected to switchgear terminals with 64 Nos 6.06
brass/cadmium plated nut bolts in an approved manner. (A) 1.5/
14 Supplying & erecting approved make SMC press moulded
composite FRP. loop-in, loop-out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E),DIN rail for Rupees Five
mounting mob & hinged doors as per requirement having locking Hundred
arrangements with mounting clamp with nuts, bolts & washers 8 Nos. 515.1
suitable for erection on pole with cable clamps& earth bolt of Paise Ten Only
following size of box. (B) 250mm x 200mm x 100mm [deep] (
SINTEX,ESCO,EPP, NATIONAL)
Rupees Five Lakh(s) Forty Eight Thousand Eight Hundred Ninety Four And Paise Sixty Only
I / We am / are willing to carry out the work at ___________________________
above / below ______________________________________ percent ( should be written in figures and words )
below / above the tendered rates mentioned above.
Amount of my / our tender works out as under :-
Estimated amount Estimated amount
put to be tender Rs. _____________ put to be tender Rs. _____________
Deduct ______% below Rs. _____________ Add ______% above Rs. _____________
In words :- In words :-
* Please strike out whichever is not applicable.
1. I / We hereby declare that I / We have visited the site and fully acquited myself / ourselves
with the local situtaion regarding materials, labour and other factors pertaining the work
before submeeting this tender.
2. I / We hereby declare that I / We have carefully studied conditions of contractors,
specifications and other the tender documents of this work and agree to work execute that
same accordingly.
3. All Electricals items Used In This work, make approvel of all electricals items must be obtained from
the Executive Engineer (Electrical) before starting the education of the work.
Sign Of Contractor
Dy.Executive Engineer,
Patan Electrical( R & B ) sub. Div.
Dismental Material List
Name of Work:- Repairs to Street Light and Street Light Cable in Court Building Santalpur, Varahi, Dist. Patan.
ITEM DETAILS QTY Unit AMOUNT
NO. RATE AGE RATE
1 Damaged Allu. Cable 4 X10 860 Mtr 125 7 8.75
3 Street light 36 Watt 18 Nos 3184 4 127.36
4 Flood Light 6 Nos 5858 4 234.32
5 Fabrication Item 12 kg - - 30.00
Sign Of Contractor
Dy. Executive Engineer,
Patan Electrical sub. Div.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
G S T LTR.pdf
GR.pdf
Notice No 4.pdf
PQ REGULAR.pdf
scheduel a b and dm.pdf
STANDARD BIDDING DOCUMENTS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .