Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹50.5 L+₹6.7 L (15.4%)Rejected-Finance H NO 352 SECTOR 1 CHANNI HIMMAT JAMMU J K 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance Other than L1 after deduction of sch of credit for Rs 98264.00 | |
| 3 | L3₹51.5 L+₹7.8 L (17.8%)Rejected-Finance | L3 | Rejected-Finance Other than L1 after deduction of sch of credit for Rs 98264.00 | |
| 4 | L4₹52.0 L+₹8.2 L (18.8%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L4 | Rejected-Finance Other than L1 after deduction of sch of credit for Rs 98264.00 | |
| 5 | Rejected-Technical | - | Rejected-Technical not considered for opening of financial bid being two class below |
Tender Value
₹64.0 L
EMD Value
₹1.2 L
Closing Date
22 Oct 2024, 6:00 pmClosed
SHRI AK MISHRA, IDSE, CWE
HQ CWE MAMUN C/O 56 APO
SPECIAL REPAIR TO TOILET BLOCKS OF CHILDREN SCHOOL AT MIL STN SAMBA
2024_MES_671097_2
CWE/M-21/2024-25
Open Tender
Civil Works
Item Rate
240 days
SAMBA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE SAMBA
₹1.2 L
Yes
9 Jan 2025
1 Oct 2024
29 Oct 2024
1 Oct 2024
22 Oct 2024
8 Oct 2024
Amount
Material and labour for brick work with subclass 'B' bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 including demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,drains etc, but excluding ashlars facings, dressed stone work and precast concrete articles and removing unserviceable material from the work site outside defence premises complete all as specified and directed by Engineer-in-Charge.
M&I Brick work with subclass 'B' bricks, old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 but except bricks including demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,drains etc, but excluding ashlars facings, dressed stone work and precast concrete articles and removing unserviceable material from the work site outside defence premises complete all as specified and directed by Engineer-in-Charge.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
Complete removal of existing roof treatment and roughening surfaces of old concrete floor by picking sweeping clean and washing down with water to remove dust, etc complete all as specified and directed.
M&L Rendering 10 mm thick on concrete surfaces in sunken/roof surfaces in CM 1.3 surfaces finished even and smooth (without using extra cement) but using WPC as per manufacturers instruction complete all as specified and as directed Note: WPC shall be measured and paid separately @200ml per 50Kg of cement.
M&L for cleaning of dust removal to all loose existing sunken floor any material manually and with heat tark gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repair all joints and cracks with highly elastic bituminous cold applied putty of tarplasic having penetration after setfing upto 8mm. Levelling of surface to give proper slope will be done as per site requirements with make of approved by GE. Cold applied Bituminous mortar and cold emulsion cum water proofing liquid of make as approved by GE, created SSD condition on surface with water. Prime the surface with make as approved by GE mixed with portable water in the ratio of 1:1 and apply @ 400gm per Sqm (as per surface condition). Apply first coat of water based bitumious liquid membrane of make as approved by GE alongwith 200% conforming to ASTM-C-412 & having crack bridging of 8mm conforming to ASTM-C-836 with tensile strength after 7 days 0.50mm conforming to ASTM-C-412 with no diluation water on primed surface while the surface is still tacky with consumption of 700gm /Sqm. Apply 2nd coat on and after curing of first coat with consumption @ 700gm/Sqm in opposite direction of 1st coat by brush or roller. Allow it to dry for 10-12 hrs after apply 3rd coat with consumption @ 700gm/Sqm. Ensure final curing time of 36 hrs before allowing/carrying out any further work. Conduct ponding test after minimum 7 days applying 2 coats of UV Resist and Elastomeric Exterior Axcrylic weather resistant water proof coating of make as approved by GE having elongation of 300% after curing of 14 days conforming to ASTM D-6083 for UV protection of bituminous Elastomeric Acrylic emulsified liquid membrance of make as approved by GE to give long life and prevent its deterioration from sunlight Note: Application of water proofing treatment will be done by authorised applicator only.
M&L for cement concrete type E-2, 1:5:10 (using 40 mm graded crushed stone aggregates) in sunkan filling and mass concrete complete all as specified and directed by Engr-in-charge.
S&F G.I. pipe 40mm bore tubing medium grade galvanised with all fitting fixed to wall, ceiling and laid in floors complete as in spout of sunken floor all as specified and directed
M&L for reinforced cement concrete M-25 as in fins, facias, louvers, parapets and railings exceeding 60cm in height and the like including demolition of existing cement concrete (reinforced) as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and as directed by the Engineer -in-Charge.
M&L for TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer in Charge
M&L for use and waste of formwork to fins, louvers, facias etc for fair finished surfaces complete all as specified and as directed by the Engineer in Charge.
Material and labour for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular joint free) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured or white cement laid over 15 mm thick screed bed in CM (1:6) including dismantling of existing floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles from site and rubbish off the premises and roughening surface of old concrete floor by picking, sweeping clean and washing with water complete all as specified & directed.
Material and labour for glazed coloured ceramic tiles joint free in vertical surfaces of wall of size 350x250x7mm/450 x300 x 7mm thick set & jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles over 10 mm thick rendering in CM 1.3 on brick /concrete surfaces including dismantling of existing floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles from site and rubbish off the premises complete all as specified & directed.
M&L for machine cut kota stone slab flooring 20-25mm thick jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete laid over 20mm thick screed bed in CM 1:6 including demolition of existing stone slabs and tiles of any description or thickness in floors, laid bedded pointed and in any mortor complete all as specified and as directed by the Engineer.
M&L Kota stone 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick cement screed in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including demolition of existing stone slabs and tiles of any description or thickness in floors, laid bedded pointed and in any mortor complete all as specified and as directed by the Engineer.
M&L for 10 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1.6 and finished even and fair without using extra cement including taking down of existing cement plaster/Dado(terrazzo) on brick/concrete or stone walls, ceiling etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick on fair faces of brick or concrete surface walls in cement mortar 1:4 over 10mm thick cement mortar 1:4 in two layers, rendering is to be finished even and fair (without using extra cement) but using with WPC as per manufacturers instruction including taking down of existing cement plaster/Dado(terrazzo) on brick/concrete or stone walls, ceiling etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer-in-Charge. Note - WPC shall be measured and paid separately @200ml per 50Kg of cement. Work shall be carried out upto 3rd storey with necessary scaffolding complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick on fair faces of brick or concrete surface ceilings, in cement mortar 1:3, rendering is to be finished even and smooth (without using extra cement ) including taking down of existing cement plaster/Dado(terrazzo) on brick/concrete or stone walls, ceiling etc, including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer-in-Charge.
Supply only of liquid water proofing compound ISI marked complete all as specified and directed.
M &L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified & directed.
Applying neat cement slurry @ 3.0 kg/ sqm including cleaning surfaces, complete all as specified and directed.
M&L PCC 1:2.4 type B-0 (using 12.5mm graded crushed stone crushed aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028 of SSR-Part-II 2020, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
Material & labour for APP modified roof treatment over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification complete all as directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufactured by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gms/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane, Physical property of membrane shall be as under :- (i) Membrane weight not less than 3.60 Kg/Sqm. (ii) Non woven polyester weight not less than 160 gsm/Sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650/Sqcm and transverse not less than 450/sqcm at 230 degree Celsius. (v) Tear strength - longitudinal not less than 300 N & transverse not less than 250N. (vi) Elongation of reinforcement not less than 30%. (vii) Impermeability under water pressure not less than 3 Kg/Sqcm. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap. (e) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
M & L for two coats of solar reflective bituminious aluminium paint on top of membrane shall be provided as prescribed by manufecturer complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1.00 Sqm and n.exc. 2.00 sqm each and refixing in the same opening complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutter (without taking off shutter from the frame) n.exc 1.5 Sqm each including cutting holes for taking out hold fast or dismantling brick work and removing from site complete all as specified and directed by Engineer-in-Charge.
Material & labour for pressed steel frames 105mmx60mm for door, made out of 1.25 mm thick MS sheet with one or more rebates including necessary fixing lugs, hinges, lock strike plate and back filling for chowkats in PCC (1:3:6) type C-0 (using 12.5mm graded crushed stone aggregate) tarring ends incl two coats of synthetic enamel paint over a coat of red oxide primer on exposed surface complete all as specified and directed.
Supply & fixing 35mm thick factory made 2nd class hard wood plain, framed, panelled shutters (two panels) with lock rail and panels of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial face veneers on both sides.The size of rail and style as per IS–1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified and directed.
S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specifications and drawing including making good to disturbed surface of walls, complete all as specified and as directed by Engr-in-Charge.
Matenal & labour factory made steel windows double shutter box type, outer frame made out of ERW TUBE 'P' section (60×45x25mm) and shutters of ERW TUBE 'P' section (50x35x20mm) operable shutters side hung including pistol hinges with two Nos of MS Tower bolts 150mm size on each shutter steel handle and stopper of 'Z' section as specified complete with sash bars devetailed or welded ready for glass fixing and wire gauzed fixing with suitable fittings/opening for cooler/AC where required. Steel windows will be double shutter external glazed and internal wire gauzed complete all as specifed and as per Drg No CEPZ/TD-324/07 1/3 to 3/3 all as specified and directed by Engr-in-Charge. NOTE: The quoted rate against the above item shall also include (i) 04 Nos MS Steel lugs of 20x5mm MS flat 20cm long over all welded to frames (ii) PCC block for embedding lugs.
All as per Srl Item No 30 here-in-above but in ventilators of any size complete all as specified and directed.
Repairs to steel window, ventilators of any size to make it functional (including slot pin, hinge, hook and eye of standard quality where required), resecuring of windows wire gauge and railings/grills by using welding equipments, complete all as directed.
S&F 4.00mm thick sheet glass ordinary qualty glazing with oil putty or any type of beads in square n.exc 0.5 Sqm each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site including hacking out old existing broken glass (any thickness, size qualily or description) from any types of wooden/steel/alum (up to 4th storey) frames or store concrete or brick surrounds glazed with putty or fixed complete all as specified (upto fourth storey with necessay scaffolding), complete all as specified and directed by Engineer-in-Charge.
S&F 4.00 mm thick figured glass, pin head type and glazing with oil putty or any type of beads in square n exc 0.50 Sq each pane in any type of frame of iron/Steel/Wood/Aluminium as required at site including hacking out old existing broken glass (any thickness, size qualily or description) from any types of wooden/steel/alum (up to 4th storey) frames or store concrete or brick surrounds glazed with putty or fixed complete all as specified (upto fourth storey with necessay scaffolding), complete all as specified and directed by Engineer-in-Charge.
M&L for securing glass of any description in existing wooden and iron frames glazed with putty/beads including removing loose or decayed putty/beads, painting/oiling one coat on rebates, grooves, reputtying and painting/oiling puttied surface to match existing work (New length of trame reputtied shall be measured and paid for).
Supply and fixing stainless steel wire cloth 0 36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple complete all as specified and directed by Engineer-in-Charge.
Supply & fixing galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or beading etc, complete all as specified and directed.
Supply & fixing in repair galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm fixed with tinned tacks, wire staples or beading etc, complete all as specified and directed.
S&F butt hinges of mild steel cold rolled medium weight of size 100mm as specified.
S&F aluminium anodised, barrel tower bolts size 150 mm of extruded section and fixed complete all as specified. (ISI Marked) complete all as specified & directed.
S&F Aluminium handles, fabcated type, anodised Size-100mm, anodised section and fixed complete all as specified. (ISI Marked) complete all as specified & directed.
S&F Aluminium alloy, anodised, sliding door bolt Size- 250 mm with hasp, staple (boll type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified.
S&F aluminium hanging floor door stopper, Twin rubber stopper, size 100mm, anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or dyed to required colour and shade, with necessary screws etc complete
Dismantling of Cl or Concrete drain pipes up to 150mm dia, jointed in cement mortar and taking out of trenches, if required complete all as specified & directed.
Dismantling of Cl or Concrete drain pipes up to 100mm dia, jointed in cement mortar and taking out of trenches, if reguired complete all as specified and directed.
Taking down eaves gutters and PVC rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc, including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessores) complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints, fixed to walls except pipes complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, fixed to walls except pipes complete all as specified and directed
S&F PVC (SWR) 110mm bore bends any radius complete, all as specified and directed.
S&F PVC (SWR) 110mm bore bends any radius with access door complete, all as specified and directed.
S&F PVC (SWR) 110mm bore branch piece, single (single Y) equal or complete, all as specified and directed.
S&F PVC (SWR) 75mm bore vent cowl complete all as specified and directed
S&F PVC (SWR) Floor trap, 75mm dia outlet, plain with grating inckuding jointing with solvent cement complete all as specified and directed.
S&F PVC (SWR) 75mm bore bends any radius complete all as specified and as directed.
S&F in repair C P Brass grating with hole 150mm dia as per sample to be fixed with white cement complete all as specified and directed.
S&F in repair Vitreous china, squatting pan 'Orissa' pattern size 580x440mm white with integral foot rest including all joints and making good to the floor, etc complete all as specified.
S&F in repair Vitreous china wash down water closet pan padestal pattern white, excluding fixing bolts, flushing cistern but including flush pipe, seat cover complete all as specified
S&F in repairs PVC valveless, 10 Itrs, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed
Taking down Gl pipe 15mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
Taking down GI pipe 20mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified and directed
Supply and fixing 20 mm nominal outer dia Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11, having thermal stability for hot & cold water supply, including all Plain CPVC SDR 11 fittings & brass threaded fittings on walls/ceiling or laying in floors including fixing the pipe with clamps. This includes jointing of pipes & fittings with one step CPVC solvent cement, complete as per direction of Engineer in Charge
Supply and fixing 25mm nominal outer dia Chlorinated Polyvinyl Chloride (CPVC) pipes SDR 11, having thermal stability for hot & cold water supply, including all Plain CPVC SDR 11 fittings & brass threaded fittings on walls/ceiling or laying in floors, including fixing the pipe with clamps. This includes jointing of pipes & fittings with one step CPVC solvent cement, complete as per direction of Engineer in Charge.
Cutting chases, pining in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing steps, cills, sunshades , shelves, lintels, etc., and cutting chases for concealed water tubing or concealed conduit wiring. etc, and making good cutting not exceeding 10 cm girth in brick walls complete all as specified and directed.
S&F in repair to bib Cock with wall flange cast copper alloy, chromium plated fancy type complete all as specified and directed.
S&F in repair 15mm bore angle valve with wall flange, cast copper alloy, chromium plated fancy type screwed for 15mm iron pipe, complete all as specified.
S&F in repair 15mm bore CP Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified.
Supply and fixing in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F in repair Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified.
S&F in repair stainless steel soap dish holder complete all as specified and directed.
S&F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and directed.
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified.
S&F in repair PVC connection 15 mm x 600 mm including brass check nut at both ends screwed for iron pipe of 15 mm bore complete all as specified and directed.
S&F in repair under counter basin white colour with fixing accessories set, size: 560 x 470x190mm, Oval shape, including CP Waste Coupling and PVC waste pipe complete all as specified.
S&F in repair Vitreous China, wash basin, white, flat back, of size 550mmx400mm including brackets of any size, including pedestal cutting for and pinning in ends of brackets of erecting stand including fixing and supply of waste pipe of 32 mm dia waste coupling of chromium plated brass complete all as specified and as directed by Engineer-in-charge
Supply and fixing of rotational moulded polyethylene water storage tanks of 1000 litres capacty. (cylindrical, vertical with closed top) with plastic lid cover, triple layered, white, hoisted and fixed in position all as specified in SSR Part-I including PTMT Ball valves high pressure with epoxy coated Aluminium rod & high density plastic ball complete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete including dismantling of existing unserviceable water tanks and removing to store of capacity 500 litres to 1000 litres complete all as specified and directed by Engineer-in-charge.
Supply and fixing of rotational moulded polyethylene water storage tanks of 500 litres capacity. (cylindrical, vertical with closed top) with plastic lid cover, triple layered, white, hoisted and fixed in position all as specified in SSR Part-l including PTMT Ball valves high pressure with epoxy coated aluminium rod & high density plastic ball complete, screwed for iron pipe or brass ferrule and fixed for 20 mm bore pipe, including making connections complete including dismantling of existing unserviceable water tanks and removing to store of capacity 250 litres to 500 litres complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 20 mm bore pipe, including making connections complete all as specified and directed.
Supply and fixing in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 15 mm bore pipe, including making connections complete all as specified and directed.
Supply and fixing in repair Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore pipe including making connections complete all as as specified and fixed (Minimum weight 20mm-210 gms).
Material and Labour for preparation of new plastered surfaces of walls, chajjas, fascia, face of columns. beams etc. and applying two coats of weather proof exterior emulsion (APEX) making good uneven surface/holes with wall care putty coloured in same shade where ever required etc (up to 2nd storey with necessary scaffolding) complete all as specified and directed.
M&L for preparation of new decorated brick/concrete/ plastered/unplastered surfaces of walls, Pillars, cornices etc by brooming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots, rubbing with sand paper and applying two coats of interior emulsion on walls, pillars cornices surface including making good uneven surface/holes with birla wall care putty coloured in same shade where ever required etc. complete all as specified and directed
M&L Preparation of new plastered surfaces and applying three coats of white wash on ceilings complete all as specified and as directed by Engr-in-Charge.
M&L for complete removal of existing treatment including washing, rubbing down with sand paper and stopping of distempered and painted surfaces including preparation of old plastered surfaces of walls and applying two coats of interior emulsion over and including one coal of primer over two coats of wall care putty 1 to 2 mm thick on plastered surfaces, preparatory to distempering complete all as specified and as directed by Engineer-in-charge.
M&L for complete removal of existing treatment including washing, rubbing down with sand paper and stopping of painted surfaces including preparation of old plastered surfaces of walls, chajjas, fascia, face of columns, beams etc. and applying two coats of weather proof exterior emulsion (APEX) making good uneven surface/holes with wall care putty coloured in same shade where ever required etc (up to 2nd storey with necessary scaffolding) complete all as specified and directed.
M&L Preparation of new painted wooden surfaces having width/girth exceeding 10 cm including necessary putty filling with knife of same colour where required to achieve smooth and even surface and applying two coats of synthetic enamel paint on wood surfaces over one coat of pink primer of any description (up to2nd storey with necessary scaffolding) complete all as specified and directed
M&L for preparation of new painted steel surfaces having width/girth exceeding 10 cm including necessry rubbing with sand paper or grinding by hand grinder to achieve smooth and even surface and applying two coats of synthetic enamel paint on steel surfaces over a coat of red oxide primer of any description (up to 2nd storey with necessary scaffolding) complete all as specified and directed
M&L for preparation of old painted wooden surfaces having width/girth exceeding 10 cm including necessary putty filing with knife of same colour where required to achieve smooth and even surface and applying one coat of synthetic enamel paint on wood surfaces of any description ( up to 2nd storey with necessary scatfolding) complete all as specified and directed
M&L for preparation of old painted steel surfaces having width/girth exceeding 10 cm including necessary rubbing with sand paper or grinding by hand grinder to achieve smooth and even surface and applying one coat of synthetic enamel paint on steel surfaces of any description (up to 2nd storey with necessaryscaffolding) complete all as specified and directed
S&F vitreous china urinal, half stall type, white, excluding flushing cistern, flush pipe but including CP waste fitting 32mm bore and PVC waste pipe and fixed complete all as specified and as directed by the Engineer in Charge
S&F vitreous china urinal squatting plate type, white, excluding flushing cistern, flush pipe and fixed in repairs complete all as specified and as directed by the Engineer in Charge
M&L for Granite 20mm thick table rubbed and polished in steps, jambs, pillars, window cills, cooking platforms, counter wash basins and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixure of pigment to match with black colour complete all as specified and as directed by the Engineer in Charge
Cutting holes in to or through brick walls built in cement mortar superficial area exceeding 400 sqcm but not exceeding 1000 sqcm complete all as specified and as directed by the Engineer in Charge
M&L for providing precast cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in louvers and jallies set in cement mortar 1:4, 35mm thick ( measured soild) including all moulding but excluding frame complete all as specified and as directed by the Engineer in Charge.
M&L for PCC 1:3:6 type C-2 (using 20 mm graded crushed stone aggr). 75mm thick as in plinth protection finished even and smooth without using extra cement layed in bays not exc. 2 00m and joints filled with bitumen sand mastic with ratio (1:3) complete all as spd & directed.
M&L for 25mm thick cement concrete 1:2:4, Type B-1 (using 20mm graded crushed stone aggregates) as in sub-base of floor for tiles/kota stone complete all as specified & directed.
Supplying, providing and applying waterproofing treatment to slab area with Paints SmartCare Damp Block 2k @1.5kg/sqm, Dampblock 2k is a two component elastomeric cementitious coating conforming to ASTM D 412 & ASTM D 4548.5 standards including all necessary surface preparation, etc. complete as per manufacturers specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1.0mm. The coating shall have a 100% elongation and crack bridging upto 1.2mm as per ASTM D4548.5 complete all as specified and directed.
Cleaning/ clearing of sewage line (including manholes) 150 mm to 300 mm main line from 1st manhole onwards bore of any description, underground at any depth, removing any type of blockage including Desludging descaling & decoking of drain as well as manholes with combined high pressure water jetting cum suction (vacuum) type machine mounted on LCV/HCV and having facilities of high pressure vacuum and provn of hydraulic through high pressure thermo plastic fiber based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same in the tank to a place outside cantonment at the place meant for the local municipality complete all as directed by Engr-in-Charge.
Cleaning of blocked WC, Gully traps, nahni trap, floor trap including and up to first manhole with manual labour as well flushing with water making the WC seat operational, including depositing sludge in borrow pits including digging of pits. Covering with excavated earth at a suitable depth all as specified and directed by Engr-in - charge
Cleaning of manholes completey by emptying semi solid, solid foul contents including cleaning inlets, outlets making the manholes clean for free flow of sewage water with combined high pressure water jetting cum suction (vacuum) type machine mounted on LCV/HCV and having facilities of high pressure vacuum and provn of hydraulic through high pressure thermo plastic fiber based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same in the tank to a place outside cantonment at the place meant for the local municipality, all as directed by Engr-in-Charge
M&L cement concrete type B1 1:2.4 (using 20 mm graded crushed Stone aggregate) as in surface channel and drain etc complete all as specified and as directed
Demolition and breaking up drain pipes 150/200 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified.
Excavating in trenches in any type of soil n.exc 1.5 m wide and n.exc 15 m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n.exc 1.5 m in depth and getting out complete, all as specified.
M&L 150 mm bore/inner Dia double wall corrugated HDPE Pipes (SN-8) with integral socket and necessary fittings, laid in trenches, including jointed and overlaping of pipe complete all as specified and directed.
Supply and fixing factory made precast 40 mm thick cover for Gully trap and similar work, area of each exc 0 04 Sqm and not exceeding 0.20 sqm complete all as specified and directed.
Grubbing up vegetation, small trees. from roots, Surface dressing, n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out clean adjacent to plinth protection of building for free flow to rainwater, all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete, all as specified.
Removing excavated material not exc. 50 m and depositing spreading and leveling where directed by Engr-in-charge.
M&L Providing precast cement concrete Type B-1, 1:2:4 (using 20 mm graded crushed stone aggregate) in landings, cover slabs (for man holes cover) similar articles with plain faces complete all as specified.
M&L for repairing of concrete surfaces such as balcony, chajjas, upward or downward facias ,column, pillar, ceiling and similar items with plain cement concrete 1 2 4 type B-0 (using 12.5 graded crushed stone aggregates) including minimum reinforcement or rendering 10-15mm thick as in bldg No P-12 site requirement in CM 1:3 (without using extra cement) finished even and fair complete all as specified and directed (Up to second storey bidgs and including necessory formwork and scaffolding and provision of minimum reinforcement required as per site condition also taking down or dismantling as required at site) Note Reinforcement will be measured separately
Taking down carefully copper/aluminium point wiring (light, fan, light & power socket) complete with fittings and fixtures such as switches, ceiling rose , pendents, regulators, socket, lamp holders brackets, bulk head fitting, etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and also making good disturbed surfaces of wall, floors etc all as specified and directed by Engr in Charge
M&L for point wiring with 1.5 sqmm copper conductor (Multistranded) PVC insulated and unsheathed FRLS electric cable 1100 volts grade and including PVC casing caping/conduit pipe of suitable size with all fittings accessories and including PVC insulated electric cable 1100 volts 1.5 sqmm (multi stranded) copper conductor single core (Green colour) cable as continuous earth wire connected to common earth dolly including sunk sheet terminal box made out of 1.6 mm thick MS sheet concealed on wall or on surface as per site requirement and making good disturbed surface of wall covered with 3 mm thick plastic laminated sheet for one light point/fan point/Bell point controlled by one, one way switch complete all as specified and as directed by Engr In Charge.
All as per Srl item no 118 here-in- above, but for one 3 PIN socket outlet 5 amp on the independent board complete all as specified and directed by Engr In Charge
All as per Srl item no 118 here-in-above, but for one 3 Pin socket outlet 5 amp on same board with other switches with 1.5 Sqmm cable complete all as specified and directed by Engr-in-Charge.
All as per Srl item no 118 here-in-above, but for one socket out let 15 amps on the independent board with 2.5 Sqmm copper conductor multistranded PVC insulated and unsheathed electric cable 1100 volts (ISI MARKED) including PVC insulated and unsheathed electric cable 1100 volt 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and directed by Engr-in-Charge.
S&F in replacement Sheet metal enclosure factory made (double door) shutter type for MCB DB SPN, 240 Volts, 4 ways with 200 Amps rated bus bar, neutral link, earth bar complete all as specified and directed by Engr-in-Charge.
S&F in replacement SPN 40 to 63 Amp, 10KA, 240 Volts complete all as specified and directed by Engr-in-Charge
S&F in replacement MCB SP 5 to 32 Amp, 10KA, 240 Volts complete all as specified and directed by Engr-in-Charge
S&F in replacement switch piano, flush type 5 Amp, One way complete all as specified and directed by Engr-in-Charge
S&F in replacement socket outlet 2-in-1, 3 pin 5 Amp flush type complete all as specified and directed by Engr-in-Charge
S&F in replacement switch socket combination 5 in 1, 5 & 15 Amp flush type complete all as specified and directed by Engr-in-Charge
S&F in replacement ceiling rose surface type 3 terminal size 65 x 50 mm surface type complete including complete all as specified and directed by Engr-in-Charge
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down existing old unserviceable complete all as specified and directed by Engr-in-Charge.
S&F sub main wiring with two run of 6 Sqmm (2x 6 Sqmm) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping/ PVC conduit ISI marked with all accessories etc with one run of 6 Sqmm (1x 6 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire and making good to match with existing surfaces including taking down old existing submain wiring complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6 Sqmm (2x 6 Sqmm), one run of 6 Sqmm (1x6 Sqmm) cable and one metre of PVC casing caping will be measured as one unit.
Material and labour for in replacement of earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point, etc, including taking down of old u/s earthing set and testing on completion complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 m GI earth lead. (iii) Item includes the cost of Charcoal and commercial salt ( For Main DBs )
S&F Factory made solid PVC Moulded door shutter 28 to 30 mm thick (Stiles) with particle board core with 2, 4 or 6 raised panel design with 2 mm thick moulded Prelam PVC sheet on the front face & 2 mm Prelam PVC sheet on back face, to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawing, complete all as specified and as directed by Engr-in-Charge.
M/S ARUN ANAND (BID ID -3139673)
BALI ENTERPRISES (BID ID -3136123)
M/s Sahib and Company (BID ID -3139951)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .