Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAccepted-AOC | ₹2.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.9 Cr+₹11.3 L (3.98%)Rejected-AOC ANJILIMOOTTIL ASOKAPURAM AE LSGD EDATHALA EDATHALA GRAMA PANCHAYATH EDATHALA PO | ₹2.9 Cr+₹11.3 L (3.98%) | L2 | Rejected-AOC L2 |
Tender Value
₹2.6 Cr
EMD Value
₹1 L
Closing Date
22 Mar 2022, 6:00 pmClosed
Project Director
Office of the Project Director Project Management Unit, Rebuild Kerala Initiative, LSGD, Ground Floor, Central Telephone Exchange, Near Government Press, Statue, Thiruvananthapuram, Pin-695001
Upgradation of Kallanchery Tharasseri Road in Kumbalangy GP Kochi LAC in Ernakulam District
2022_LSGD_479242_20
A1/142/2020/PMULSGD
Open Tender
Civil Works - Roads
Item Rate
300 days
Ernakulam
Please refer Tender documents.
6 documents required · 6 mandatory
₹7,500
Yes
₹1 L
Yes
21 Dec 2022
7 Mar 2022
25 Mar 2022
7 Mar 2022
22 Mar 2022
7 Mar 2022
7 Mar 2022 - 15 Mar 2022
Amount
Site Clearance
2.5.2.A : Dismantling of Structures<br> Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.<br>(II) By Mechanical Means <br> (A) Cement Concrete
2.5.2.B : Dismantling of Structures<br> Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202.<br> (II) By Mechanical Means <br>(B) Reinforced Cement Concrete
Roadway
3.4 : Construction of Embankment with Material Obtained from Borrow Pits <br> Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
3.14 : Construction of Subgrade and Earthen Shoulders<br> Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
4.1.A.3 : Granular Sub-base with Well Graded Material (Table 400.1) <br> (A) By Mix in Place Method <br> Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.<br> (iii) For Grading III Material
4.9 : Wet Mix Macadam <br> Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. <br> By Mechanical Means with 1 km lead
od1650985/2021_2022 : Construction of un-reinforced ,plain cement concrete pavement ,thickness as per design,over a prepared sub base,with 43 grade cement or any other type as per clause 1501.2.2 M 30 (grade),coarse and fine aggregates conforming to IS<br>383,maximum size of coarse aggregate not exceeding 25 mm,mixed in a concrete mixer of not less than 0.2<br>cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side<br>formwork(steel channel, laying and fixing of 125 micron thick polythene film, wedges,steel plates including<br>levelling the formwork as per drawing),spreading the concrete with showels,rakes,compacted using<br>needle,screed, and plate vibrators and finished in continuous operation including provision of contraction<br>and expansion ,construction joints, admixtures as approved,curing of concrete slabs for 14 days,using<br>curing compound(where specified) and water finishing to lines and grade as per drawing and Technical<br>Specifications clause 1501
od1653408/2021_2022 : Supplying and laying interlocking tile 100 mm or nearest size thickness, minimum strength M 40 including providing a layer of 6 mm aggregate for 5 cm thickness, then laying interlock cobbles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & conveyance charges etc.; complete. (As per morth 55.22)
75.8.1.1.A : Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate: 4 course aggregate) laid to required slope as required including compaction, finishing and tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)
Box Culver, Retaining walls & Drains
11.1.1.1 : Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I.Ordinary soil (i)Upto 3 m depth
od1429938/2021_2022 : Coconut Pile - Supplying and stacking well matured straight coconut post for driving<br>down throug various strata bellow bed level including cost coveyance labour charges etc complete. (Derived<br>from DAR 60.64.1)<br>
od1429769/2021_2022 : Cutting and removing the excess length of wooden piles to lines and levels and<br>removing the cut end of piles and stacking within 150m
od1429819/2021_2022 : Driving down coconut pile to lines and levels through variuos strata<br>including all hire charges and labour for fixing , staging platform and all other appliances necessary for pile<br>driving down after pointing the bottom end (Derived From DAR 60.64.4)
14.8 : Providing and laying of dry rubble flooring complete as per drawings and technical specifications Clause 1303.3
75.7.1 : DRY RUBBLE MASONRY _ Random rubble masonry with hard stone, including Through/Bond stone in foundation and superstructure including packing to compactness to lines and levels, cost and conveyance of all materials labour charges etc. complete as per approved drawing and relevant technical specifications.
11.4.1.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I.P.C.C grade M 10 (i)Nominal mix 1:3:6
11.4.2.1 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II.P.C.C grade M 15 (i)Nominal mix (1:2.5:5)
75.8.1.1.A : Providing Plain cement concrete for wearing coat CC 1:2:4 (1 cement: 2 fine aggregate: 4 course aggregate) laid to required slope as required including compaction, finishing and tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)
11.4.4 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203IV.R.C.C grade M 20
75.8.1.1 : Providing plain/reinforced concrete(1 cement:2 fine aggregate: 4 course aggregate) for substructure as per drawings and technical specifications Clause 802, 803, 1202 & 1203 as required including compaction, finishing and tamping etc .complete. Max. size of course aggregate not exceeding 25mm , mixed in concrete mixer etc complete as per specification (i) Nominal mix (1:2:4)a)Materials
11.2.1 : Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 I. Sand filling
od1431992/2021_2022 : Bailing out water Using 5HP Pump- Bailing out water with 5HP engine and pump<br>set including conveyance to site and erection,cost of fuel, lubrication oil and other<br>stores, pay of staff etc complete
od1653373/2021_2022 : RING BUND Type II Putting up ring bund with earth fille gunny bags of top width<br>1.0m bottom width 2.0m height 2.0 m side and filling in between with earth to<br>form ring bund and maintaining the same leak proof till the completion of the<br>work and clearing the site by dismantling the bund after completion of the<br>work.etc.complete.<br>
od1432048/2021_2022 : Supplying & laying of drainage composite for use behind walls, between two different fills, alongside<br>drains of road, below concrete lining of canals etc. Geocomposite for planar drainage, realized by<br>thermobonding a draining core in extruded monofilaments with two filtering nonwoven geotextiles that<br>may also be working as separation or protecting layers. The draining three dimensional core will have a<br>“W” configuration as longitudinal parallel channels. Minimum thickness to be 7.2mm, with two filtering<br>UV stabilized polypropylene nonwoven geotextile of minimum thickness of 0.75mm charecteristic<br>opening size (O90) of 110 micron and tensile strength of 8.0 kN/m that will be working as separation or<br>protecting layer, geocomposite having in plane flow capacity of 2.1 L / (m.s) at hydraulic gradient of 1.0 &<br>20 kPa pressure and tensile strength of 18 kN/m , with mass per unit area of 740 gsm, supplied in the<br>form of roll for easy transportation to site of work as per detailed specification all complete as per<br>directions of Engineer in charge. (modified item 26.16 of DSR)
11.4.5 : Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203V. R.C.C. grade M 25
11.7 : Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
12.5.4 : Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 For height upto 5 mIV.R.C.C. grade M 25
12.6 : Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
13.1.2 : Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5R.C.C M 25
13.2 : Supplying, fitting and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002,1010 and 1202
13.20.1 : Providing and laying parapet with PCC M 15 as per drawing & technical specifications Clauses 800 and 1208.4 II.Nominal Mix (1:2.5:5)
10.5 : Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
Traffic signs
10.2.A.1.2 : Traffic Signs<br>A. Retro-reflectorised Traffic Signs <br> 1 Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 <br> 2 600 mm Equilateral Triangle
10.2.A.1.3 : Traffic Signs<br>A. Retro-reflectorised Traffic Signs<br>1 Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801 <br> 3 600 mm Circular
od585131/2020_2021 : Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads on Bituminous Surface @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes. (Derived from 8.13 MoRTH Roads)
10.10.2 : Kilometre Stone Kilometre Stone Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703 2Ordinary Kilometer Stone (Precast)
10.10.3 : Kilometre Stone Kilometre StoneReinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703iii)200 m stone (precast)
od1653405/2021_2022 : Providing and erecting retro-reflectorised Object Hazard Marker 300mm x<br>900mm<br>Providing and erecting retro-reflectorised Object Hazard Marker sign with 07<br>years warranty, manufactured as per IRC 67 USING Type IV ASTM D 4956-09<br>micro prismatic retro reflective sheeting fixed over aluminium sheetig, 2 mm thick<br>/ aluminium composit material sheeting 4 mm thick with suitable back support<br>frame and supported on a mild steel angle iron post 75mmx75mmx6mm, firmly<br>fixed 30cm above ground level by means of properly designed foundation with M<br>15 grade cement concrete 30cmx30x45cm, 45cm below ground level including<br>painting all non-reflective faces with epoxy paint 2 coats over epoxy primer as<br>per approved drawing and clause 801.<br>300 mm x 900 mm(Data from MORTH 55.10.1)<br>
10.4.A.2 : Direction and Place Identification signs with size more than 0.9 sqm size board<br> A. Retro-reflectorised Traffic Signs <br>2 Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on dia GI Pipe firmly fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per approved drawing and Technical Specification Clause 1701
od1427339/2021_2022 : Providing and fixing guard post<br><br>Providing and fixing guard post of size 200mmx200mm, 1400mm long, 800mm above ground level and 600mm below GL. casted in M20 Grade concrete reinforced with 4 nos of 8mm dia longitudinal bars and 6mm dia stirrups @ 100mm c/c, firmly fixed in position by means of foundation of size 0.5mx0.5mx0.7m in M15 grade concrete below ground level including painting 2 coats on exposed surface with synthetic enamel paint in alternate white & black band 20cm wide
ABDUL RASHEED A I
Bidder Name
ABDUL RASHEED A I
K A SALAHUDHEEN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .