Loading…
Loading…
Tender ID
Tender Value
₹5.9 Cr
EMD Value
₹5.9 L
Closing Date
16 Mar 2026, 5:00 pmClosed
Deputy Municipal Commissioner, North Zone
CONSTRUCTION OF WARD OFFICE BUILDING AT F.P.NO. 158 , T.P.S.NO. 65 - SAIJPUR BOGHA IN THKKAR NAGAR WARD, NOTH ZONE, AHMEDABAD.
283342
E Tender Notice No.18/2025-26 Tender No.02
Open
Civil Works
Works
Ahmedabad
4 documents required · 4 mandatory
₹12,000
Municipal Commissioner, Ahmedabad
₹5.9 L
6 Mar 2026
6 Mar 2026
6 Mar 2026
16 Mar 2026
6 Mar 2026
Name of Work:- CONSTRUCTION OF WARD OFFICE BUILDING AT F.P.NO. 158
T.P.S.NO. 65 - SAIJPUR BOGHA IN THKKAR NAGAR WARD, NOTH
ZONE, AHMEDABAD
Bill of Quantities
Sr. No. Qty Items Unit Rate Per Amount
Civil Work Estimate
1 Demolition & Dismantling work
Demolition of RCC work using Hydra
Breacker including stacking of
servicable materials and disposal of
a 12.00 unservicable materials with all lead 1047.38 Cu.M.
and lift.Removal Of Existing Building
Foundation and Super Structure If
Demolition of Brick work and stone
masonry including stacking of
serviceable materials and disposal of
b 14.00 unserviceable materials with all lead 544.95 Cu.M.
and lift.(ii) In Cement Mortar.Removal
Of Existing Building Foundation and
Super Structure If Any.
Dismentaling of sheet roofing
including ridges, Hips, Valleys,
Gutters etc. stacking of serviceable
materials and disposal of
unserviceable materials with all lead
i 5.00 (i) G.I.sheet roofing. 47.25 Sq.mt
ii 5.00 (ii) A.C. sheet roofing. 53.55 sq.mt
Dismentling steel work including
d 1000.00 distempering and stacking the 3.63 Kg.
materials with all lead and lift.
Dismentling doors, windows,
ventilators etc. (wood or steel)
shutters including chowkhats
e 2.00 architraves, hold fasts and other 185.85 Each
attachment etc. complete and
stacking them with in all lead and lift.
(i)Notexceeding 3 Sq.M. in area.
Removing & Scrapping of Old
deteriorated Plaster of any thickness
f 63.00 from Masonary / R.C.C. member 19.38 Sq.M.
including stacking of serviceable
material & disposal of un serviceable
from site of work with all lead & lift.
Dismentaling any type tiled of stone
floors laid in mortar including stacking
g 45.00 of serviceable materilas and disposal 47.25 Sq.M.
of unserviceable materials with all
Excavation for foundation including
sorting out stacking of useful material
2 & disposing of excavated stuff upto
mt. lead. Loose & Soft soil.Excexuted
With Mechanical Effort
a 1545.00 up to 1.5 mt. depth 115.92 Cu.M.
c 1725.00 3.0 to 5.0 mt. depth 141.11 Cu.M.
d 296.00 above 5.00 mt. depth 162.02 Cu.M.
Add extra for Disposing off the
e 50.00 excavated stuff of above items for 17.28 Cu.M.
lead of (A) 50 m to 100 m
Add extra for Disposing off the
f 50.00 excavated stuff of above items for 34.56 Cu.M.
lead of (B) 100 m to 200 m
Add extra for Disposing off the
g 50.00 excavated stuff of above items for 51.84 Cu.M.
lead of (C) 200 m to 300 m
Add extra for Disposing off the
h 50.00 excavated stuff of above items for 76.80 Cu.M.
lead of (D) 300 m to 400 m
Add extra for Disposing off the
i 50.00 excavated stuff of above items for 128.00 Cu.M.
lead of (E) 400 m to 500 m
Providing and installing cast in situ
single under reamed piles of specified
diameter and length below pile cap,
excluding the cost of Concrete, steel
reinforcement but including the cost of
boring with bentonite solution and the
length of the pile to be embedded in
pile cap etc. all complete. (Length of
pile for payment shall be measured
upto to the bottom of pile cap) :
i 10.00 400 mm dia. Piles 644.63 Rmt.
ii 20.00 450 mm dia. Piles 705.03 Rmt.
Extra over single under ream for
providing additional bulbs in under
reamed piles, under specified
diameter excluding the cost of
Concrete, steel reinforcement (only
the nos. of extra bulbs are to be paid).
t 1.00 400 mm dia. Piles 813.05 Each
ii 2.00 450 mm dia. Piles 1103.43 Each
Provdg. & laying cement concrete
1:5:10 (1 cement : 5 course sand :
hand broken aggregates 40 mm
nominal size) and curing complete,
excluding cost of form work in
foundation & Plinth.
Provdg. & laying cement concrete
1:3:6 (1 cement : 3 coarse sand :
3b hand broken stone aggregates 40 mm
nominal size) and curing complete
excluding cost of form work in
284.00 (A) Foundation and plinth 2976.00 Cu.M.
Supplying of graded hand brocken
3c 136.00 stone size of 90 mm to 127 mm at site 983.93 Cu.M.
(Rubble or Spoul)
Labour charges for spreading the
spouls 90 mm to 127 mm thick layer
good earth filling in voids correcting
3d 592.00 the grade & camber comp. with 26.79 Sq.mt.
rolling, watering, incl. preparing
thesurface by brushing for removing
all loose or dirts ect.comp.
Provdg. & laying cement concrete
1:4:8 (1 cement : 4 coarse sand :
hand broken stone aggregates 40 mm
nominal size) and curing complete
excluding cost of form work in
foundation& plinth.
Filling available excavated earth
(excluding rock) in trenches, plinth,
sides of foundations etc. in layers not
exceeding 20 cm. in depth
consolidation each deposited layer by
ramming and watering.
Conveyance charges of earth lime,
6 murrum, building rubbish, manure,
garbage, sludge, excavated rock, fly
ash, aggregate of any kind etc. comp.
a 200.00 Conveyance charges upto 1 km 320.20 Cmt
b 200.00 Conveyance charges upto 2 km 347.73 Cmt
c 7500.00 Conveyance charges upto 5 km 408.41 Cmt
d 7500.00 Extra For Lead on Above Item Above 9.26 Cmt
5 km & upto 6 km
e 7500.00 Extra For Lead on Above Item Above 9.26 Cmt
6 km & upto 7 km
f 7500.00 Extra For Lead on Above Item Above 9.26 Cmt
7 km & upto 8 km
g 7500.00 Extra For Lead on Above Item Above 9.26 Cmt
8 km & upto 9 km
Extra For Lead on Above Item Above
Filling in plinth with sand under floors
including watering, ramming,
consolidating, compacting and
dressing etc. completed.
Filling in foundation and plinth with
murrum or selected soil in layers of
7b 150.00 cm. thickness including watering, 286.20 Cmt
ramming and consolidating etc.
Brick work using common burnt clay
building bricks having crushing
8 strength not less than 35 kg/Sq. cm. in
cement mortar 1:6 (1 cement : 6 fine
sand) conventional brick
a 88.00 (a) in foundation & Plinth 3981.21 Cu.M.
b 288.00 Super structure Upto Floor Two Level 4253.46 Cu.M.
Super structure Above Floor Two
I.Half brick masonry in common burnt
clay building bricks having crushing
9 strength note less than 35 Kg/Sq. Cm.
in cement mortar 1:4 (1 cement :
coarse sand) using conventional brick
in Super structure upto floor Four level
a 308.00 All Floor Level 646.70 Sq.M.
Providing and laying controlled
cement concrete of M-25 Grade and
curing complete, Excluding the cost of
10.1 form work, Scaffolding, cost of
reinforcement for reinforced concrete
work For any Height up to any
Foundations,Raft,Footings,Mass
b1 2.00 RCC Retaining wall at All Floor 4519.88 Cu.M.
Tie-Beam, Lintel , Beam- Bracket,
c1 16.00 Stair Case & Landing, Coping ,Slab, 4496.07 Cu.M.
balcony, weather shed, loft , any
cantilever etc All Floor
d1 13.00 Columns,Pillars, posts and struts at 4593.91 Cu.M.
Providing and laying controlled
cement concrete of M-20 Grade and
curing complete, Excluding the cost of
10.2 form work, Scaffolding, cost of
reinforcement for reinforced concrete
work For any Height up to Floor Four
Foundations,Raft,Footings,Mass
Tie Beam , Lintel , Beam- Bracket
Coping ,landing, Slab, balcony,
weather shed, loft , any cantilever etc
c1 2.00 Column at All Floor 4558.20 Cu.M.
d1 1.00 Stair Case All Floor 5418.91 Cu.M.
Providing and laying in position Ready
Mixed M250 grade concrete for
reinforced cement conctere work
using cement content as per approved
Design Mix manufactured in fully
automatic batching plant and
transported to site of work in transit
mixer for all lead having continuous
agitated mixer, manufactured as per
mix design of specified grade for
reinforced cement concrete work
including pumping of R.M.C. from
10.3 1393.00 transit mixer to site of laying with all 4853.56 Cu.M.
lead and lift, excluding the cost of
centering shuttering finishing and
reinforcement including cost of
admixtures in recommended
proportions as per IS: 9103 to
accelerate/ retard setting of concrete,
improve workability without impairing
strength and durability as per direction
of the Engineer - in charge. Without
Fly Ash (Min cement level as per
latest IS 456 shall be maintained)
(Cement level 450 kg )
Providing and laying in position Ready
Mixed M200 grade concrete for
reinforced cement conctere work
using cement content as per approved
Design Mix manufactured in fully
automatic batching plant and
transported to site of work in transit
mixer for all lead having continuous
agitated mixer, manufactured as per
mix design of specified grade for
reinforced cement concrete work
including pumping of R.M.C. from
10.4 3.00 transit mixer to site of laying with all 4793.10 Cu.M.
lead and lift, excluding the cost of
centering shuttering finishing and
reinforcement including cost of
admixtures in recommended
proportions as per IS: 9103 to
accelerate/ retard setting of concrete,
improve workability without impairing
strength and durability as per direction
of the Engineer - in charge. Without
Fly Ash (Min cement level as per
latest IS 456 shall be maintained)
(Cement level 400 kg )
Drilling suitable holes in reinforced or
plain cement concrete with power
driven drill machine to a minimum
depth of 80mm upto 250mm in RCC
beams, lintels, columns and slabs to
10.5 introduce steel bars for
sunshades/balconies including fixing
the steel bars in position using Hilti
Chemical HY200-R but excluding the
cost of reinforcement, all complete as
per direction of Engineer-In-Charge.
a 140.00 8 mm Dia in 80 mm Deep & 12 mm 183.52 Each
b 1100.00 10 mm Dia in 100 mm Deep & 14 mm 263.66 Each
c 1100.00 12 mm Dia in 120 mm Deep & 16 mm 343.80 Each
d 120.00 16 mm Dia in 160 mm Deep & 20 mm 608.63 Each
e 45.00 20 mm Dia in 200 mm Deep & 25 mm 1024.44 Each
f 20.00 25 mm Dia in 250 mm Deep & 32 mm 1938.54 Each
Providing and laying controlled
cement concrete 1:2:4( 1cement :
coarse sand : 4 Graded stone
11 aggregate 20 mm nominal size ) and
curing complete, Excluding the cost of
form work and reinforcement for
reinforced concrete work in:
Foundations, footings, base of
a 1.00 columns,grade slab and mass 3923.53 Cu.M.
slab, landing shelves, Balconies,
b 1.00 lintels, beams, girders, and cantilever, 4012.47 Cu.M.
up to aany floor level.
P/A Trimix with dewatering machine
c 984.00 and floater machine on constructed 54.00 Sqmtr
R.C.C. work incl. cost of machine and
labour etc. comp. as directed.
Making 15 mm Groove in R.C.C work
d 320.00 on road and filling it with poly sulfied 30.00 Rmt
selant and finished it good incl. all
labour charges etc. comp. as directed
Providing and laying and fixing 25 mm
thick expansion joint by hydrocell semi
e 26.00 rigid UV resistance with high 738.13 Sqmt
performance laminated closed cell
polythene foam joint filler in sheet
foam as directed, etc. complete.
Providing form work in ordinary timber
planking so as to give a rough finish
including centering, shuttering,
strutting and propping etc. height of
12 propping and centering below
supporting floor to celling not
exceeding 4 M & removal of the same
for in situ reinforced or plain concrete
a 461.00 (A) Foundation, footings, bases of 171.68 Smt
columns etc. and mass concrete.
b 1917.00 (B) Flat surface such as soffits of 252.00 Smt
slabs, landing and the like
c 2153.00 (C) Vertical surfaces such as walls 229.95 Smt
(any thickness) partitions.
(D) Columns, pillars, posts & struts.
d 1483.00 (1) Square, rectangular, polygonal in 297.68 Smt
e 20.00 (2) Circular or curved in plan. 422.10 Smt
(H) (1) Sides and soffits of beam,
f 2655.00 haunchings cantilevers, girders, 192.15 Smt
bressumers, Coping and lintels not
exceeding 1 M in depth.
(2) Sides and soffits of beam,
haunchings cantilevers, girders,
bressumers and lintels exceeding 1 M
h 164.00 (L) chullah hoops, weather sheds, 155.78 Smt
chhajas, carbels etc including edges.
(M) Staircase with-sloping or stepped
i 200.00 soffits incl. risers & strings excluding 242.55 Smt
Extra for additional height of propping
and centering where the height of
propping and centering exceeds 4 .O
M between supporting floor to ceiling
including temporary brick or stone
pillars for supporting as required.
(i)Height more than 4.0 M.and upto
Extra for additional height of propping
and centering where the height of
propping and centering exceeds 4 .O
M between supporting floor to ceiling
including temporary brick or stone
pillars for supporting as required.
(i)Height more than 6.0 M.and upto
Providing T.M.T Fe 500D bar
reinforcement for R.C.C. work
13 including bending, binding and placing
in position complete up to any floor
a 173770.00 All Floor Level 75.46 Kg.
Providing and laying polished Kota
stone slab (Polished / River Finish,
Green colour ) flooring over 20 mm.
(average) thick base of cement mortar
1:6 (1 cement : 6 coarse sand) or lime
mortar 1:1.5 laid over and joined with
grey cement slurry including rubbing
and polishing complete.25 mm th.
Providing and laying polished Kota
stone slab 25 mm. thick in Platform
,Riser of Stair , Skirting, Tread , dado
and pillars laid on 10 mm. thick
15 45.00 cement mortar 1:3 (1 cement : 3 1176.03 Sq.M.
coarse sand) jointed with grey cement
slurry including rubbing and polishing
and MAking groove where it is
Required etc. compl
Providing and laying white/Colur
glazed tiles 6 mm thick in flooring
16 3.00 treads of steps and landing laid on a 908.17 Sq. M.
bed of 12 mm thick cement mortar 1:3
(1 cement : 3 coarse sand) finished
with flush pointing in white cement.
Providing and layingWhite / Colour
glazed tiles of size 600 mmx300mm x
8 mm / 300 mmx 450mm x 8 mm in
17 275.00 skirting, risers of steps, Floor and 1426.95 Sq. M.
dedo on 10 mm. thick cement plaster
1:3 (1 cement : 3 coarse sand) and
jointed with white cement slurry.
Providing and laying marble stone
slab flooring over 20 mm. (Average)
base of cement mortar 1:6 (1 cement:
6 coarse sand) or L.M. 1:1.5 laid and
jointed with grey cement slurry
including rubbing and polishing
complete: (A) Marble slab 25 mm.
Providing and laying Vitrified tiles 8 to
10 mm thick , 24'' x 24'' in flooring
19a 850.00 treads of steps and landing laid on a 1062.50 Sq. M.
bed of 12mm thick cement mortar 1:3
(1-cement : 3-coarse sand) finishing
with flush pointing in white cement.
Providing and laying Vitrified tiles 8 to
10 mm thick , 24'' x 24'' in skrting
risers of steps and dedo on 10mm
thick cement plaster 1:3 (1cement : 3-
coarse sand) and jointed with white
P & L 24" x 24" vitrified 8 mm thick tile
20 mm (average) base of cement
mortar 1:6 ( 1cement: 6 coarse sand)
on new surface or fixing on existing
19c 100.00 flooring by adhesive material including 1383.99 Sq.M.
dismentaling of existing flooring and
jointed with color cement slurry
including finised with flush pointing &
cleaning the surface etc. complete for
Providing and laying Ceramics tiles
to 8 mm thick in flooring, treads of
steps, landing and dedo on 12 mm.
thick cement plaster 1:3 (1 cement :
coarse sand) and jointed with white
Providing & Laying 18 mm thick Mirror
polish granite For flooring , counter
stair -riser , tread , skirting , dedo
Jambs etc. machine cut or chiselled
21 520.00 on bed of cement mortar 1:1 pointing 2385.71 Sq. M.
with neat cement slurry incl. moulding,
Making grooves where it is required
etc. comp. as per instruction of
engineer in charge.
Provdg. 20 mm. thick Finish / Mala
cement plaster in single coat on fair
side of brick / concrete walls for
interior plastering upto any Floor level
and finished even and smooth in
i 3793.00 All Floor Level 190.58 Sq.M.
Provdg. 20 mm. thick Finish / Mala
cement plaster in single coat
plastering on ceilings, Beam side and
sofits of stairs upto any Floor level
and finished even and smooth in
i 2071.00 All Floor Level 215.15 Sq.M.
Providing & fixing 23 cm wide chicken
mesh jali with nails & then application
c 644.00 of 15 mm plaster on R.C.C. & 315.15 Sq.mt
masonary joints as per dir. of engg. In
Providing and mixing water proofing Per Bag
materials in cement mortar in of 50 Kg
d 200.00 proportion recommended by the 48.77
manufacturer. etc. comp. as per Cement
instruction of engineer in charge.
Providing 20 mm th. Double coat
Sand face / Mala Cement Plaster on
Walls upto any Height Above Ground
level consisting of 12 mm th. Backing
coat of C.M. 1:3 ( 1 cement : 3 Ssand
) & 8 mm th. Finishing coat of C.M.
1:1 ( 1 cement : 1 sand ) ets.
White / Color washing with lime on
undecorated wall surfaces (two coats)
to give an even shade including
thoroughly brooming the surface to
remove all dirt, dust mortar drops and
other foreign matter.
Providing & Applying 3 mm thick
External Wall Rustic Type Texture as
24b 950.00 per Design & Make as Approved by 424.92 Sq.M.
Consultants / Engineer in Charge.
Work Includes All Necessary
Scaffolding Work upto Any Height.
Finishing walls with Acrylic Smooth
exterior paint of required shade :New
work (Two or more coat applied @
1.67 ltr/10 sqm over and including
priming coat of exterior primer applied
P./L. METALIC HERITAGE
SURFACE TEXTURE
Providing and fixing of HERITAGE
textured homogeneous wall finishing
system from BAKELITE HYLAM LTD
or equivalent make consisting of a two
component system of (25 kgs per
Pack) made of 92% silica particles
coated with fade resistant pigments,
100% acrylic polymer bonding agent
(5kgs per pack) with the applied
24d 25.00 thickness of the coating being 637.38 Sq.M.
between 0.8mm-1.2mm to be applied
on acured, smooth level plaster
without keying, as per the
shades/combinations approved, as
per the manufacturer directions, for
usages, tobe applied by an approved
applicator of the manufacturer, as per
the directions / supervision of the
engineers in charge, all complete.
Includes All Necessary Scaffolding
Work upto Any Height.
Providing and Fixing 18 mm thick
concrete base exposed brick cladding
including surface waterproffing,
polymer modified tile adhesive and
polymer modifies tile grout ( grey /
white) with neccesary scafolding etc
compl. As per direction of engg.
Wall Painting (two coats) with plastic
emulsion / Oil paint of approved brand
and manufacture and of shade
required on undecorated wall surfaces
to give an even shade, over and
including a priming coat with alkali
25a 4500.00 resistance primer of approved brand 78.44 Sq.M.
and manufacture after thoroughly
brushing the surface free from mortar
droppings, and other foreign matter
and also including preparing the
surface even and sand -papered
Extra over above item for every
subsequent coat of of wall painting
with plastic emulsion / Oil paint of
approved brand.
Applying two coats of Birla (white
cement based) or Asian (acrylic lapy-
putty) or equivalent & two coats of
primer of approved brand and
manufacture on new wall surface to
give an even shade including
thoroughly brushing the surface free
from mortar dropping and other
foreign matter and sand papered
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
2.0 mt.,refilling, trasporting the pipe to
work site, unloading, lowering in
trenches, laying and jointing the pipes
26 in c.m. 1:1 incl. all jointing materials
such as cement, sand, hemp, bitumen
as dire. testing the pipe line to a head
of 1.5 mt. and hydraulic test as dire
incl. watering trenches, spreading
and carting away of surplus earth
within 100 mt.lead as dire. etc. comp.
a 30.00 23 cm dia. 344.64 Rmt
Providing & Laying & Jointing glazed
stoneware pipes incl. excavation up to
2.0 mt.,refilling, trasporting the pipe to
work site, unloading, lowering in
trenches, laying and jointing the pipes
in c.m. 1:1 incl. all jointing materials
such as cement, sand, hemp, bitumen
as dire. testing the pipe line to a head
of 1.5 mt. and hydraulic test as dire
incl. watering trenches, spreading
and carting away of surplus earth
within 100 mt.lead as dire. etc. comp.
b 25.00 15 cm dia. 288.23 Rmt
c 15.00 10 cm dia. 211.05 Rmt
Constructing brick masonry chamber
for under ground C.I. Inspection
chamber and bends with bricks having
croshing strength not less than 35 Kg.
Cm2 in C.M. 1:5 C.I. cover with frame
(Lightduty) 455mm x 610 mm intenal
dimensions total weight of cover with
frame to be not less than 38 Kg. (Wt.
of cover 23Kg.) and Wt. of frame
27 8.00 15Kg.) (R.C.C.top slab with 1:2:4 mix 3863.85 No.
(1-cement:2-coarse sand:4-graded
stone aggregate 20mm size)
foundation concrete 1:5:10 inside
plaster 15 mm thick with cement
mortar 1:3 finished smooth with a
floating coat of neat cement on walls
and bed concrete etc. complete.(i)
Inside dimensions 455 mm x 610 mm
and up to 850 mm deep
Constructing Manhole with R.C.C. top
slab in 1:2:4mix (1-cement: 2-coarse
sand:4-graded stone aggregate
mm nominal size) foundation concrete
1:3:6 mix (1-cement:3-coarse sand:6-
Brick bats 40+50mm size) inside
plastering 15mm thick with Cement
Mortar 1:5 (1-Cement:5-coarse sand)
finished with a floating coat of neat
cement and making channels in
cement concrete 1:2:4 mix (1-
Cement:2 -Coarse sand:4-stone
aggregate 20 mm nominal size)
finished smooth complete including
curing and festing (i) Inside size
900mm x 1200mm and up to 1.5M.
deep including C.I. cover with frame
size 560 mm diameter total weight of
cover and frame to be not less than
128kgs. (Wt. of cover 64Kg. and Wt.
of frame 64Kg.) (A) With 230 mm thick
walls of brick masonry using brick
having crushing strength not less than
35Kg./Sq.cm. in Cement Mortar 1:5
(1-Cement: 5-Coarse sand) (2)B type
depth up to 1.50 Metre
Providing and fixing white vitreous
china flat back or wall corner type
lipped front urinal basin of
340x280x470 mm sizes respectively
with standard flush pipe, Waster Pipe,
29a 12.00 Waste Coupling, PVc Connection and 3344.35 No.
G.I clamps complete, including
painting of fittings and brackets,
cutting and making good the walls and
floors wherever required : Cera Model
No. S4020103 or Equivalent
Providing and Fixing of C.P. Brass
BIB Cock of 15 mm Dia of Jaquar
b 40.00 make florentine series model no. 1564.17 No.
5047n or equivalent make with all
necessary fittings. as approved by
Engineer - in - charge.,
Providing and fixing brass screw down
Angle stop tap.(A) 15mm dia. Of
c 40.00 Jaquar make florentine series 1160.57 No.
modelno. 5053n or equivalent make
with all necessary fittings. as
approved by Engineer - in - charge.,
Providing and fixing C.P. brass
d 1.00 shower rose with 15mm or 20mm inlet 279.37 No.
Shower Arm.(A) 100mm dia. Each
Provding and Fixing of autoclosing
pressmatic pillar cock / bib cock with
all necessary fittings of Polished
e 20.00 Bright Chrome Finish of Jaquar make 3280.52 No.
model no. 031L65 or equivalent make
as approved by Engineer in Charge.
Rate including of cost of labour,
material etc. in complete manner.
Providing and Fixing of C.P. Brass
Two Way Bib Cock of 15 mm Dia of
Jaquar make model no. 041kn or
equivalent make approved make with
all necessary fittings. as approved by
Engineer - in - charge.,
Providing and Fixing of C.P. Brass
urinal Valve Auto Closing System
With Full Built in Control Cock & Wall
Flange of 15 mm Dia of Jaquar make
model no. 077 or equivalent make
approved make with all necessary
fittings. as approved by Engineer - in -
Provdg. & laying S.W. Gully trap with
C.I. garting brick masonry chamber &
30 8.00 water tight C.I. cover with frame of 1234.57 No.
300 mm x 300 mm size ( inside) with
standard weight. sqare mouth trap
size 150 x100 mm P trap
Providing erecting and fixing double
coated ISI water tank of required
31 2000.00 capacity each with all necessary 3.91 Litre
fittings and connection etc. complete
Extra rate over item of excavation of
earth for excavation of asphalt
pavement/RCC of thickness up to
0.20 meter including demolishing the
asphalt carpet, metal, soiling / cutting
Reinforcement etc.comp. with
stacking the material as directed.-up
to 0.20 meter thickness
Providing and fixing PVC SWR Nahni
trap IS 14735 for drain - 100 mm
diameter with jali of the following
33 30.00 nominal diameter of self cleansing 565.43 No.
design with C.I scread down or hinged
grating including the cost of cutting
and making good the walls.
Provdg. And fixing Concealed / Open
to wall, ceiling & floor in true line and
level UPVC pipe Schedule- 40 of
make as approved by engg. incharge.
pipe shall be fix on wall with the help
34a of clamp at every twi meter center to
center of shall be concealed as
directed in cluding neccesarry fitting
etc. in cluding testing of pipe and
jointd and fixing the same with
adhesive solvent , including cost of all
materials of following nominal bore
iii 30.00 32 mm 117.97 Rmt
Providing and fixing concealed center
point to wall ceiling & floor CPVC
(SDR 13.5) PIPE having National
Sanitation Foundation (NSF) seal for
potable water of following dia. nominal
bore tube fittings and clamps including
making good the wall, ceiling and floor
iii 5.00 25 mm 247.25 Rmt
Provdg. And fixing to wall ,ceiling and
floor 10.00 kg. F/Sq.Cm2 working
pressure polythelene pipes of the
following outside diameter, low,
density, complete with special flange
compression type fittings, wall clips
etc. making good wall ceiling and
b 75.00 (A) 75mm dia 274.68 Rmt
Providing and fixing water closet
squatting Pan ( Indian type W.C. Pan)
36 6.00 size 580mm (A)VitreousChina. (I)Long 1351.49 No.
pattern = White colour with Trap and
Pair of Foot Rest
Providing and fixing white vitreous
china extended wall mounting water
37a 17.00 closet of Cera Make S1043101 Carat 12613.27 No.
Model Or Equivalent Model With EWC
Soft Close Seat Cover, Chair Bracket,
nuts, bolts and gasket etc complete.
Providing and Fixing of C.P. Brass
Flush Cock / Concealed Cock of
mm Dia of Jaquar make model no.
081 or equivalent and Outer Body of
Jaquar make model no. 5083KPM or
equivalent approved make with all
necessary fittings. as approved by
Engineer - in - charge.,
Providing and fixing Health Faucet of
Jaquar make model no. 573 oe
c 17.00 equivalent make as approved by 1543.36 No.
engg. In charge with flexible tube upto
1 metre long etc. complete.
Providing and fixing 24"x18"x8"
Carysil Elegance or Equivalent Make
of Single Bowl Sink S.S. Matt Finish
With Waste Coupling, Waste Pipe,etc.
cutting and making good the walls
wherever required.
Providing and fixing Under counter
Wash basine including 15 mm C.P.
Brass Pillar tap, 32 mm C.P. Brass
Waste of Standard make, Cutting &
b 8.00 Making good the wall / granite 6641.14 No.
Wherever Required in White Color :
Model S2030101 of Cera Clair Series
or Equivalent make Wash basine of
size : 520x450 mm
Providing and fixing Wall Hung wash
basin Including 32 mm C.P. brass
waste of standard pattern, cutting and
c 5.00 making good the walls / granite 3825.20 No.
wherever require:In White Color :
Cera Cadal Or Equivalent Make Wash
basin of size 515 x 410 mm
Provdg. & fixing 600mm x 450 mm
Bevelled edge mirror of superior glass
mounted of .6 mm th. A.C. sheet or
plywood sheet and fixed to wooden
pluge with C.P. brass screws and
Providing and fixing mirror of superior
glass (of approved quality) and of
required shape and size with plastic
b 1.00 moulded frame of approved make and 1773.73 No.
shade with 6 mm thick hard board
backing : Rectangular shape
Provdg. & fixing C.P..Brass towal rail
40 10.00 complete with C.P. brass brackets 597.22 No.
fixed to wooden plugs with C.P. Brass
screws.(600 mmx 20 mm size)
Providing and fixing ball valve (brass)
41 of approved quality, High or low
pressure, with plastic floats complete :
ii 1.00 20 mm dia 1099.94 No.
iii 15.00 25 mm dia 1552.93 No.
iv 8.00 40 mm dia 3312.60 No.
Providing and fixing Full Way valve
42a (HEX) with wheel of approved quality
i 2.00 15 mm Full Way valve (HEX) 1461.17 No.
ii 2.00 20 mm Full Way valve (HEX) 1924.61 No.
iii 6.00 25 mm Full Way valve (HEX) 2535.55 No.
iv 1.00 32 mm Full Way valve (HEX) 3377.64 No.
v 8.00 40 mm Full Way valve (HEX) 4661.10 No.
vi 2.00 50 mm Full Way valve (HEX) 6675.14 No.
Providing and Fixing of C.P.Brass
43a 1.00 Pillar Cock of 15 mm Dia of approved 1725.21 No.
make with all necessary fittings. as
approved by Engineer - in - charge.,
Providing fixing of SS grab bar with all
b 3.00 hardwares for Physically Handicap 1937.24 No.
Providing and laying integral cement
based water proofing treatment
including preparation of surface as
required for treatment of roofs,
balconies, terraces etc consisting of
following operations:
(a) Applying a slurry coat of neat
cement using 2.75 kg/sqm of cement
admixed with water proofing
compound conforming to IS. 2645 and
approved by Engineer-in-charge over
the RCC slab including adjoining walls
upto 300 mm height including
cleaning the surface before treatment.
(b) Laying brick bats with mortar using
broken bricks/brick bats 25 mm to
mm size with 50% of cement mortar
1:5 (1 cement : 5 coarse sand)
admixed with water proofing
compound conforming to IS :
and approved by Engineer-in-charge
over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 coarse
sand ) admixed with water proofing
compound conforming to IS :
and approved by Engineer-in-charge
to required slope and treating similarly
the adjoining walls upto 300 mm
height including rounding of junctions
of walls and slabs.
(c) After two days of proper curing
applying a second coat of cement
slurry using 2.75 kg/ sqm of cement
admixed with water proofing
compound conforming to IS :
and approved by Engineerin- charge.
(d) Finishing the surface with 20 mm
thick jointless cement mortar of mix
1:4 (1 cement :4 coarse sand)
admixed with water proofing
compound conforming to IS :
and approved by Engineerin- charge
(e) The whole terrace so finished shall
be flooded with water for a minimum
period of two weeks for curing and for
final test.“All above operations to be
done in order and as directed and
specified by the Engineer-in-Charge
:and shall be guaranteed for minimum
period of 10 years after handing over
the completed building by the main
contractor to be finished as directed.
Stamp paper guarantee 10 years to
be furnished before receiving any
payment from the client.
With average thickness of 120 mm
and minimum thickness at khurra as
Providing and laying broken chine
mosaic flooring for terrace using
mm to 20 mm broken pieces of glazed
tiles to be laid over cement mortar 1:3
b 450.00 to plain or slope and to be tempered 739.89 Sq. M.
to bring mortar creme out upto surface
using white cement including rounding
off junctions and extending them upto
15 cm along the wall,clearing with
water and oxalic acid etc. as directed.
Providing and applying fibre
reinforced elastomeric liquid water
proofing membrane with resilient
acrylic polymers having Sun
Reflectivity Index (SRI) of 105 on top
of concrete roof in three coats @10.76
litre/ 10 sqm. One coat of self-priming
of elastomeric waterproofing liquid
(dilution with water in the ratio of 3:1)
c 360.00 and two coats of undiluted elastomeric 562.40 Sq. M.
waterproofing liquid (dry film thickness
of complete application/system not
less than 500 microns). The operation
shall be carried out after scrapping
and properly cleaning the surface to
remove loose particles with wire
brushes, complete in all respect as
per the direction of Engineer-in-
Filling in Sunken Portion with good
Quality Aerated light weight concrete
block having crushing strength not
less than 35 kg/sqcm and where
d 37.00 directed by the Architect / Engineer-in- 4559.61 Cmt
charge, in sunk in layer. including
watering, ramming where it is required
etc. complete, as directed by the
Architect / Engineer-in-charge .
Providing and laying cement concrete
flooring ( I.P.S.) 1:2:4 (1-cement : 2-
45 200.00 coarse sand : 4-graded stone 348.08 Sq.M.
aggregate 20mm nominal size) laid in
one layer and finished with a floating
coat of neat cement. (B) 50mm thick.
Providing and fixing M.S. grills/ Gate
of required pattern to wooden/ Granite
frames of windows etc. with M.S. flats
at required spacings and frame
46a 4500.00 alround, square or round bars with 100.17 Kg.
round headed bolts and nuts or by
screws all complete as per the
structural designs and directions of
Engineer in charge
Providing & Fixing Structural steel
work ( Confirming to IS 4923-1997)
riveted, bolted or welded in builtup for
all type sections, in framed work,
b 2000.00 including cutting, hoisting, fixing in 126.68 Kg.
position and applying a priming coat
of approved steel primer all complete
as per the structural designs and
directions of Engineer in charge
Applying priming coat over new steel
and other metel surface after and
including preparing the surface by
throughly cleaning, oil, grease, dirt
and other foreign matter and scoured
with brushes fine steel wood, scrapers
and sand paper with ready mixed
priming paint brushing red lead.
Painting two coats (excluding priming
coat) on new steel and other metal
surface with enamel paint, brushing,
interior to give an even shade
including cleaning the surface an even
shade including cleaning the surface
of all dirt, dust and other foreign
Providing & Fixing 1.50 mm Thick
S.S.-304 Grade 1150 mm High S.S.
Railing having Hand Rail Member of
50 mm Dia., 4 No. of Horizontal Pipe
e 15.00 of 16 mm Dia. & Baluster Suppprt of 2270.21 R.Mtr.
40 mm Dia. At Every Third Step as
per Detail Given. Rate Includes All
Work Complete as per Description &
as per Direction of Engg. in Charge.
Providing and fixing in position
collapsible steel shutters with vertical
channels 20x10x2 mm braced with flat
iron diagonals 20x5 mm size with top
& bottom rails of T-iron 40x40x6 mm
with 38 mm dia. Steel pulleys
complete with bolts , nuts , locking
arrangement , stoppers , handles
including applying a priming coat of
red lead paint.
Providing corrugated 0.80 mm (22
gauge) thick G.I. sheets roofing fixed
with galvanized iron ‘J’ or ‘L’ hook
bolts, and nuts 8 mm. dia with
bitumen and G.I. limpet washers filled
with white lead complete excluding
the cost of purlines, rafters and
Providing valleys 900 mm. overall in
plain 1.6 mm. thick G.I. sheet Class –
c 3.00 3 fixed with ‘J’ or ‘L’ hook bolts and 1042.78 Sq.mt.
nuts galvanized from ‘J’ or ‘L’ hook
bolts and bitumen washers complete.
Providing and fixing rolling shutters of
approved make made of 80 mm wide
M.S. laths inter-locked together
through their entire length and jointed
together at the ends by end locks
48a 9.00 mounted on specially designed pipe 3468.72 Sq.M.
shaft with bracket plates, guide
channels and arragements for inside
and outside locking with push-pull
operation including the cost of hood
cover and spring etc. complete.(A)
Shutters having width below 3.5 M.
Providing and fixing 27mm domal
Series - 1.2 mm Th. Alluminium
Section Three track Sliding window
With Metalic Powder Coating and
MM Clear Glaas(Non Tuffen) Include
All Accessaries and Fixture etc.
complete as per the direction of
Engineer-in-charge.
Providing and fixing 27mm domal
Series - 1.2 mm Th. Alluminium
Section Two track Sliding window
With Metalic Powder Coating and
MM Clear Glaas(Non Tuffen) Include
All Accessaries and Fixture etc.
complete as per the direction of
Engineer-in-charge.
ALUMINIUM DOOR WORK
Providing and fixing Aluminium Door
work (Single Shutter OR Double
Shutter with fix glass) made from
Jindal or equivalent make Powder
Coated (50 micron pure polyester
coating ) ,aluminium section frame
built up standard tubular and other
section of approved make confirming
to IS 733 and IS 1285 , member size
with shutters of horizontal member
vertical member Confirming to IS733
and IS 1285 fixed with rawl plug abd
screws or fixing clips or with
expansion hold fasteners including
necessary filling up of gaps at
junctions at top bottom and sides with
required PVC/ Neoprene felt, 8/12 mm
c 16.00 toughened glass of approved make 5401.70 Sq. M.
etc. Aluminum sections shall be
smooth, rust free, straight.mitred and
jointed mechanically wherever
required including Door Hardware
such as cleat angles aluminum snap
beading for glazing /paneling, CP
Brass/ Stainless steel screws,
Stoppers, heavy duty floor hing, S.S.
Hinges, aldrop , Locking system,
heavy duty Floor Springs, Pivot and
fixtures and transparent silicon
sealant glass fixing to frame as per
details all complete as per
architectural drawings and the
direction of Engineer in Charge. rate
incl. all type of alumnium sections for
doors as per the detail Architectural
Providing and fixing standared
extruded of alluminium section of size
(Section:2434, @ Wt.0.643Kg/mt )
with colour anodized alluminium frame
for ventilation with 5 mm thick frosted
glass as details etc complete for
Providing and fixing standared
extruded of alluminium section of size
63.50 x 38.10 x 1.95 mm ( Section no:
4605, @Wt 1.094 Kg / Rmt with colour
anodized alluminium frame with 5 mm
thick transparent bronze colour tinted
float glass as details etc complete for
Providing Fixing 1.2 mm thick
Alluminium Section Partition -Fully
Glazed / Partly Panelled Partly Glazed
/ Fully Panelled , Having Size of
50c 43.00 Section of 2.1/2 x 1.1/2 with 4 mm 3124.44 Sq.mtr.
Compact Sheet / 5 mm thick Glass
Fixing with 4 mm thick EPDM Rubber
etc. Complete as per Direction of
Consultant / Engg.incharge.
Providing Fixing 1.2 mm thick
Alluminium Section Partition Door -
Fully Glazed / Partly Panelled Partly
Glazed / Fully Panelled , frame
Having Size of Section of 2 .1/2 x
.1/2 and Door Section Having Size of
Tips Vertical 1 .3/4 x 1 .3/4, Top Rail
50d 13.00 4 x 1 .3/4, Middle Rail 1 .3/4 x 1 4061.77 Sq.mtr.
.3/4, Bottom rail 4 x 1 .3/4 with 4 mm
Compact Sheet / 5 mm thick Glass
Fixing with 4 mm thick EPDM Rubber
Including Lock, Handle, Door Closer,
Door Stoper, Stopper etc Complete as
per Direction of Consultant /
Providing and fixing Structural Glazing
with using the 17 Micron anodised of
approved colour alluminium section as
transium, mullium of size 63mm x
38mm x 2 mm with using 6 mm thick
reflective structural glass of approved
make, colour / Tinted, toughned and
shade and fixed with silicone sealant
and spacer tap and at corner sealed
neoprene foam dust and Air sealed
gasket mirred including scaffolding,
cleaning of glass etc.complete at all
heights anf lifts with all necessary
fitting and fixtures, anchore fasteners,
necessary M.S. or Aluminium
brackets, suitable design for openable
or sliding window as per Architectural
drawing and as directed by Engineer-
in-charge. Grooves between the
glasses to be filled with sealant of
Dow corning - structural sealant
weather sealant 789. The entire
facade should be water proof. The
mullions are to be connected to
bracket by SS-304 nut bolts.
Measurement shall be given as per
actual execution of the work. (Rate
are included providing & fixing of MS
structure steel work wherever
Design supply & installation of
suspended Spider Glazing system
designed to withstand the wind
pressure as per IS 875 (Part-III). The
Suspended System held with Spider
Fittings of SS-316 Grade Steel of
approved manufacturer with glass
panel having 12 mm thick clear
toughened glass held together with
SS- 316 Grade Stainless steel Spider
& bolt assembly with laminated glass
fins 21 mm thick. The Glass fins and
glass panel assembly shall be
connected to Slab/ beams by means
of SS- 316 Grade stainless steel
brackets & Anchor bolts and at the
bottom using SS channel of
50x25x2mm using fastener & anchor
bolts, non staining weather sealants of
approved make, Teflon/ nylon bushes
and separators to prevent bi-metallic
contacts, all complete to perform as
per specification and approved
drawings. The complete system to be
designed to accommodate thermal
expansion & seismic movements etc.
The joints between glass panels (6 to
8 mm) and gaps at the perimeter & in
U channel of the assembly to be filled
with non staining weather sealant, so
as to make the entire system fully
water proof & dust proof.
The rate shall include all design,
Engineering and shop drawing
including approval from structural
designer, labour, T&P, scaffolding,
other incidental charges including
wastage, enabling temporary services
all fitting fixers nut bolts, washer,
Buffer plates, fastener, anchors, SS
channel laminated glass etc. all
complete. For the purpose of
payment, actual elevation area of
Glazing including thickness of joints
and the portion of Glass panel inside
the SS channel shall be measured.
Providing and fixing 12 mm thick
Toughened Glass Door with / Without
Fix Portion Including Floor Spring
51c 4.00 Lock, 300 mm Long Door Handle, Nut 6449.86 Sq.mt.
Bolt, Clamp, Connector and All
accessaries as approved by Engg.
Providing and fixing ISI marked
mm thick flush door shutters
conforming to IS : 2202 (Part I)
decorative type, core of block board
construction with frame of 1st class
hard wood and well matched teak
ply veneering with vertical grains or
cross bands and face veneers on both
faces of shutters with 1.00 mm thick
Decorative Laminated Sheet on both
faces of shutters including ISI marked
Stainless Steel butt hinges, bright
/matt finished 125 mm Stainless Steel
handles of approved quality & make,
ISI marked oxidised M.S. door latches
/ Aldrop Conforming to IS:5930 with
necessary screws etc. complete as
per direction of Engg. incharge.
Providing wood work in frames of
Doors, windows cleare story windows
b 314.00 and othersimilar works wrought, 602.04
framede and fixed in position. (A)
Indian Teak Wood
Providing and fixing 35 mm th.
Shutters for doors windows &
clearstory windows incl. wood
frames as specified 12 cm. x 7cm.
size incl. anodised alluminium fixtures
and fastenings including primer coat
of approved quality and two coats of
oil paint etc. complete.
a 3.00 Fully glazed 4788.50 Sq. M.
b 3.00 Fully panelled 5478.89 Sq. M.
c 3.00 Partly panelled and partly glazed 5133.69 Sq. M.
Providing and fixing FRP frame size
100x50 mm and 28mm thick FRP
depress panel shutter having extra
reinforcement on sides & edges in Gel
coat finish. The core of the shutter &
frame is to be filed up with injected fire
retardant grade polyurethene foam
done in situ alongwith embedded
54 39.00 wooden pieces for stiffening & also 2354.22 Sq.M.
taking hinges & fintures. The whole
FRP frame & shutter is to be water
proof weather proof, termite proof &
resistance to mild acid/alkali. Rates
are to be inclusive of S.S hinges with
necessary screws & alluminium
fixtures & fastenings & fastener
Making connection to the ex.M.H.in
running sewer incl. Dewatering and
other required machinery etc. of
55 following dia pipes at any convenient
time. All damaged work shall be well
repaired as per instructions.
a 1.00 For Pipe 150 mm to 300 mm diameter 1339.29 No.
b 1.00 For Pipe 400 mm to 600 mm diameter 2232.14 No.
Making connection of galvanised Mild
steel distribution branch with
galvanised mild steel main 50mm to
80mm nominal bore by providing and
fixing tee including cutting and
threading the pipes complete
Providing throating or plaster drip,
57a 1100.00 grooves and moulding to Wall , R.C.C. 41.25 Rmt
chajja and slab.
Providing & Laying cement vatta
cm x 10 cm in size quarter round in
c.m. 1:1 ( 1 cement, 1 coarse sand)
laid in one layers finishing with a
floating of neat cement watering etc
complete as dire.
Carring out plinth treat ment to post
construction/ existing structure by
spraying chemical solution for termite
control treatment including labour and
material consist ment withI.S.I
specification. Using Chlordene and
58 700.00 Chiorpur files 20EC. As Per 6131_ 104.90 Sq.mt
paret- II Consentration Weight one
percent is recommended i.e one litre
20EC chemical emulsion with19 liter
give1% concrentration inclusive of
one litre chemical emulsion appication
at the rate of 5 Litre chemical/ Sqm of
surface is recommended as per I.S
Carring out timber treatment to all
wood work including drilling holes and
spraying oil based chemical solution
on surface of timber work for termite
control including labour and material
etc. complete. Using Chlordene 20EC.
As Per 6113_part III Consentration
Weight 1.00 percent is recommended
one litre chemical emulsion dillute with
9 liter of kerosene precent
concentration. Total dillute
concrentration will be10litre inclusive
of the litre chemical emulsion
application 0.75/Litre chemical per
one Sqmt printed two coat wood
Paver Block Providing and laying shot
blasted Non - interlocking, Paver
blocks of specified thickness, size,
grade of concrete and colour machine
made and blasting by automatic shot
blasting machine and high density of
as per approved sample of approved
make for footpath, parking areas,
service lanes,cross over and other
areas as mentioned in the drawing.
Including providing and laying 50 mm
thick averave bedding layer of coarse
sand below paver block as per
required grading and specification.
Laid paver block shall be
mechanically compacted. The work of
the paving blocks shall be executed in
60 120.00 line and level by skilled mason of 758.93 Sq.mt.
flooring work only. Small size of paver
block with same specification shall be
used at residue or at end. It should be
laid in such a way that the no cutting
of the paver block to be necessary. If
cutting of paver block shall be
required , than cut by machine only
and laying to be done by skilled
flooring mason. The finished surface
of the paver block shall have coarse
sand Texture Finish. Pave blocks
shall be compacted and shall be re-
laid if necessary. Actual laid area shall
be measured and paid without any
wastage. (A) 80 mm thick M-35 grade
Grey Paver block of size 200mm x
200mm. As per approved rate
Providing and fixing pre-cast concrete
kerb stone of gray cement based
concrete block 30cm length,30cm
height and 15cm thick of M250 grade
61 185.00 concret as per approved design and 358.06 R.mt.
including excavation for fixing in
proper line and level,filling the joint
with C:M 1:3 (1cement:3fine sand) etc
Providing and fixing double action
hydraulic floor spring of approved
brand and manufacture conforming to
IS : 6315, having brand logo
embossed on the body / plate with
double spring mechanism and door
weight upto 125 kg, for doors,
62a 5.00 including cost of cutting floors, 4558.89 No.
embedding in floors as required and
making good the same matching to
the existing floor finishing and cover
plates with brass pivot and single
piece M.S. sheet outer box with slide
plate etc. complete as per the
direction of Engineer-in-charge. With
stainless steel cover plate minimum
1.25 mm thickness
Providing and fixing aluminium
extruded section body tubular type
universal hydraulic door closer
(having brand logo with ISi, IS :
embossed on the body, door weight
upto 36 kg to 80 kg and door width
from 701 mm to 1200 mm), with
double speed adjustment with
necessary accessories and screws
Designing, fabricating, testing,
installing and fixing in position Curtain
Wall with Aluminium Composite Panel
63 70.00 Cladding, with open grooves for linear 3061.95 Sq.mt.
as well as curvilinear portions of the
building , for all heights and all levels
etc. including:
(a) Structural analysis & design and
preparation of shop drawings for
pressure equalisation or rain screen
principle as required, proper drainage
of water to make it watertight including
checking of all the structural and
functional design.
(b) Providing, fabricating and
supplying and fixing panels of
aluminium composite panel cladding
in pan shape in metalic colour of
approved shades made out of 4mm
thick aluminium composite panel
material consisting of 3mm thick FR
grade mineral core sandwiched
between two Aluminium sheets (each
0.5mm thick). The aluminium
composite panel cladding sheet shall
be coil coated, with Kynar 500 based
PVDF / Lumiflon based fluoropolymer
resin coating of approved colour
andshade on face # 1 and polymer
(Service) coating on face # 2 as
specified using stainless steel screws,
nuts, bolts, washers, cleats, weather
silicone sealant, backer rods etc.
(c) The fastening brackets of
Aluminium alloy 6005 T5 / MS with
Hot Dip Galvanised with serrations
and serrated washers to arrest the
wind load movement, fasteners, SS
316 Pins and anchor bolts of
approved make in SS 316, Nylon
separators to prevent bi-metallic
contacts all complete required to
perform as per specification and
drawing The item includes cost of all
material & labour component, the cost
of all mock ups at site, cost of all
samples of the individual components
for testing in an approved laboratory,
field tests on the assembled working
curtain wall with aluminium composite
panel cladding, cleaning and
protection of the curtain wall with
aluminium composite panel cladding
till the handing over of the building for
occupation. Base frame work cost for
ACP cladding is included in this item
rate. The Contractor shall provide
curtain wall with aluminium composite
panel cladding, having all the
performance characteristics all
complete , as per the Architectural
drawings, as per item description, as
specified, as per the approved shop
drawings and as directed by the
Engineer-in-Charge. However, for the
purpose of payment, only the actual
area on the external face of the
curtain wall with Aluminum Composite
Panel Cladding (including width of
groove) shall be measured in sqm. up
to two decimal places.
Providing and Fixing Box type metal
letters forming composite box made
from 1mm thick stainless steel plate of
grade 304 having brush finish of
following font size to be fixed at Main
Gate in english and or Gujrati and
including fixing charges. etc.
complete as per direction of Engg.
incharge. for Payment Purpose Height
of Letter will be measured.
a 960.00 Upto 300 mm Height 93.85 R. Inch
Providing and Fixing MURAL made
out of 2mm thick s.s. plate grade
including making necessary design as
per Architect dwg. Through laser
65a 15.00 cutting including connection to the 6804.07 Sq.mt.
R.C.C./Masonary with necessary
frame,anchor fastnuts,M.S.Plate etc.
complete as per direction of Engg.
Providing and Fixing Sinage - internal
and external signage boards with
65b 7000.00 Vinyle Text on ACP sheet / 2 mm th. 9.38 Sq.Inch
S.S. Plate etc. complete as per
direction of Engg. incharge.
Providing and fixing retro Reflective Hi
Intensity Micro Prismatic Grade Board
using 2mm Aluminum / 4mm ACP,
angle iron 75 x 75 x 6mm. Descaling
and degreasing the board as per
requirement using epoxy reflactive
process by screen painting as
directed etc. complete including
transporting and fixing in C.C. 1:2:4
65c 12.00 with necessary excavation curing etc. 7535.31 Sq.mtr.
complete as per I.R.C. 67-2012
design. A warranty for 7 years for the
Retro reflective sheeting from original
manufacturer & a certified copy of
year outdoor exposure test report
from third party test lab for the product
offered shall be submitted by
contractor. (B)Class B Type-
4(MDR/ODR) retro reflective sheeting
Road marking with hot applied
thermoplastic paints with reflectorising
glass beads on bitumin surface
providing and laying a hot applied
thermoplastic compound 2.5 mm thick
including reflectorising glass beads @
250gms per sqm area, thickness of
2.5mm is excluding of surface applied
glass beds as per IRC:35-2015. The
finished surface to be level, uniform
and free from streaks and holes.
zebra patta /bump patta lane/center
65d 140.00 line/ edge line/cut patta. The white 364.08 Sqmt
color marking should provide
liminance coefficinet on cemend road
shalll be min 130 mcd/m2/lux and
Asphalt road shall be min
mcd/m2/lux during the service life
during the day time. The marking
should meet the performance criteria
for night time reflectivity, wet
reflectivity and skid resistance as
mentioned in the section-15 of IRC
352015. Warranty for the Retro
reflectivity should be two years.
CAT EYE/Pavement Marker(MNC two
nail) made out of acrylic
StreneAcrylonitrile or hi-impact poly
Steren fitted with moulded of
metheacrylate(MNC)reflector cube
corner reflector design,filled with
tightly adhering pooting compound as
per ASTMD-788 size 11.5x7x1.60
cms or 10x10x1.75 cms provided with
bituminous adhesive in sufficient
quantity with each unit fixing with two
shrank .Reflector on both side.Co
efficient of lumination as per
specification and compressive strenth
13 tones at 23 degree centigrade
etc.B) Double side lenses.
Providing and fixing eco-friendly light
weight calcium silicate false ceiling
tiles having T egular edge & 15mm
Thick Densified edges on the Tile
Periphery for Extra Strength The Light
weight calcium silicate ceiling tiles
shall have, light reflection 85% non-
combustible as per B.S.476 part IV,
100% humidity resistance and also
having thermal conductivity 0.043°
w/m KC. for the best thermal
The Light weight calcium Silicate tile
shall be of approved texture Fine
fissured/ Spintone/ Cosmos having
NRC value of 0.5 & Globe having
NRC value of 0.75 NRC or equivalent
of size 595X595 mm to be laid on true
horizontal level suspended inter
locking metal grid of hot dipped
galvanized steel sections (galvanizing
@ 120 grams per sqm including
bothside) consisting of main ‘T’ runner
suitably spaced at joints to get
required length and size of 24X38 mm
made from 0.30 mm thick (minimum)
sheet, 1200 mm centre to centre, and
cross ‘T’ of size 24X28 mm made out
of 0.33 mm (Minimum) sheet spaced
1200 mm along spaced between main
‘T’ at 600 mm centre to centre to form
a grid of 1200X600mm and secondary
cross ’T’ of length 600mm and size
24x28mm made of 0.30 mm thick
(Minimum) sheet to be interlocked at
middle of the 1200X600mm panel to
form grid of size 600X600mm resting
on periphery walls / partitions on a
perimeter wall angle pre-coated steel
of size (24X24X3000mm made of
0.40mm thick (minimum)
sheet with the help of rawl plugs at
450mm centre to centre with 25mm
long dry wall screws @ 230mm
interval and laying 15mm thick
Densified edges light weight calcium
silicate ceiling tiles of approved
texture (Fine Fissured/
Cosmos/Spintone) in the grid
including, cutting /making opening for
services like diffusers, grills, light
fittings, fixtures, smoke detectors etc.,
wherever required, Main ‘T’ runners to
be suspended from ceiling using G.I.
slotted cleats of size 25X35X1.6mm
fixed to ceiling with 12.5mm dia and
50mm long dash fasteners, 4mm G.I.
adjustable rods with galvanized steel
level clips of size 85X30X0.8mm,
spaced at 1200mm centre to centre
long main ‘T’ bottom exposed with
24mm of all T-sections shall be pre-
painted with polyester baked paint, for
, as per specifications, drawings and
as directed by engineer-
incharge.Note:- Only calcium silicate
false ceiling area will be measured
from wall to wall. No deduction shall
be made for exposed frames/ opening
(cut outs) having area less than
sqm. The calcium silicate ceiling tiles
shall have NRC. Value of
(Minimum) for Fine fissured/ Spintone/
Cosmos and 0.75 NRC for Globe,
light reflection 85% noncombustible
as per B.S. 476 part IV, 100%
humidity resistance and also having
thermal conductivity. 0.043° w/m
KC.for the best thermal Insulation
Providing and fixing single layer water
proof gypusm board 12.5 mm thick of
the make New good Group Co.Ltd. or
equivalent & New good Group Co.Ltd.
company sections using water proof
board of size 1220 mm x 1830 mm x
8.0 mm suspended by G.I suspender
of size 25 mm x 3 mm with
intermediate channel of size 18mm
x40mm x0.80mm at 1220 mm center
66b 205.00 to center ceiling section of size 600.94 Sq.mt.
40mmx 35mmx 0.55mm at 457 mm
center to center and perimetre chanel
A of size 20mm x 27mm x 30mm x
0.50mm at edges & drops including
paper taps and sofit cleat, anchor
fastener, scoch bolt connecting cleat
joining compound top coat on ceiling
including making necessary opening
for light fitting, diffuser etc. complete
as per detail drawing as directed.
Providing and Fixing 6 mm thick
Lexan Polycarbonate multi wall
67 10.00 roofing sheet fixed with hilti screw and 1427.62 sq.mt.
rubber silicon sealer and alluminium
strip of size 50 x 3 mm etc complete
as directed by Engineer in charge
Manufacturing,testing ,supplying
loading,,transporting to work
site,loading unloading lowering in
trenches,laying and jointing RCC NP3
class pipes in C:M 1:1 including all
jointing materials such as
cement,sand,hemp bitumen as
directed testing the pipe line to a head
of 1.5 mt and hydraulic test as
directed etc comp.
a 80.00 300 mm Diameter 616.07 Rmt
b 20.00 450 mm Diameter 806.25 Rmt
Constructing Bombay Pattern Type
Catch Pit of size
x 0.60 depth up to 1 mt including
excavation, B.B.C.C.
(1:5:10), 23 cms thick brick maso. wall
in the prop. of CM
69 8.00 (1:6) with 40 mm thick IPS flooring in 3125.00 No
the prop M15 at
bottom and 15 mm thick cement
plaster inside the catch pit in the
proportion of CM (1:3) with out jali etc.
CatchPit Jali Fixing P/F FRC catch pit
70 8.00 jali with frame 600mm x 600mm clear 1383.93 No
opening etc. comp.. As directed by
engineer in charge.
PERCOLATION WELL
71 120.00 Drilling of pilot bore hole in Alluvial 694.64 Rmt
Strata by direct Rotary Rig of 250 mm.
72 120.00 Reaming 400 mm 212.50 Rmt
73 1.00 Electro Logging charges with carting 16071.43 Job
Providing and Installing 200 mm dia
74 60.00 IS:12818 upvc Casing Pipe "CM" 1193.75 Rmt
class plain Pipe
Providing and Installing 200 mm dia
75 1.00 IS:12818 upvc End Cap, with Air Vent 669.64 Set
200 mm dia Regular with 1.5 mm
sloted size cage type trapezoidal
76 60.00 shape wire wound little carbon 1146.43 Rmt
galvanized screen confirming to
77 15.00 Supply of Pea sized Gravel 2029.46 Cmt
78 1.00 Air Vent of 50 mm Bend 401.79 Unit
79 120.00 Lowering and Removing of Dropline 147.32 Rmt
up to Depth 186 mtr.
80 1.00 Air Compressor 60 CFM/150 PSI 22205.36 Ls
Estimate For Civil Work With Total Rs.
Percolation Well
I. No. Qty Items Unit Rate Per Amount
Electrical Work Estimate
1 INTERNAL WIRING
Point wiring for Light / Bell with 2-1.5
sq.mm & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV
grade ZHFR/HRFR PVC insulated
multi strand copper wires up to 10 mtr
length , in below type of pipe erected
with 6A Modular type switch / bell
1.1 push & accessories and earth
continuity of following type, erected
on PVC / Metallic/Wooden box, single
mounting base frame covered with
textured/metallic/white front plate
modules erected on / in wall / ceiling
as per pipe erected, with necessary
Lamp holder/ceiling rose /
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe
205.00 and accessories erected concealed in 505.05 Pt
wall/ceiling complete
Point wiring for FAN with 2-1.5 sq.mm
& earth wire of 1.5 sq.mm (Green)
both are of .ISI marked 1.1 KV Grade
ZHFR/HRFR PVC insulated multi
strand copper wires up to 10 mtr
length, in below type of pipe erected
with 6A Modular type switch and hum
free EME four or more step type
electronic fan regulator with
separately mounted and accessories
with earth continuity of following type
erected on PVC / Metallic/Wooden
box, single mounting base frame
covered with textured/metallic/white
front plate modules erected on / in
wall / ceiling as per pipe erected. with
necessary ceiling rose /
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe
85.00 and accessories erected concealed in 701.40 Pt
wall/ceiling complete
Point wiring for secondary light point
with 2-1.5 sq.mm & earth wire of
sq.mm (green) both are of ISI marked
1.1 KV grade ZHFR/HRFR PVC
insulated multi strand copper wires, in
below type of pipe to be erected
complete with earth continuity and
necessary connection with primary
1.3 light with accessories erected on
Metal / PVC / wooden box covered
covered with appropriate front plate
modules erected on / in wall / ceiling
for open / concealed wiring. with
necessary Lamp holder / ceiling rose /
H.D.Connector as directed.as per pipe
erected with following type of
Note:- Maximum up to 6 mtrs length,
excess will be considered as Mains
for Secondary Point.
(f) with medium class Rigid PVC pipe
145.00 and accessories erected concealed in 174.30 Pt
wall/ceiling complete
Point wiring for Individual Plug with &
earth wire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade
ZHFR/HRFR PVC insulated multi
strand copper wires up to 10 mtr
length, in below type of pipe erected
1.4 complete with Modular type switch &
pin Plug erected on PVC /
Metallic/Wooden box covered with
appropriate front plate modules
erected on / in wall / ceiling as per
pipe erected with following type of
[I] For 6A Plug and 6 a switch with 2-
1.4.1 90.00 1.5 sq.mm Cu. Wire from nearby 530.25 Pt
switchboard/mcb db board
(f) with medium class Rigid PVC pipe
and accessories erected concealed in
wall/ceiling complete
[II] For 16A Plug and 16 amp switch
1.4.2 15.00 with 2-2.5 sq.mm Cu. Wire from mcb 774.90 Pt
(f) with medium class Rigid PVC pipe
and accessories erected concealed in
wall/ceiling complete
[III] For 16A Plug and 16 amp switch
with 2-4 sq.mm Cu. Wire with
sq.mm ( green) earthing wire from
(f) with medium class Rigid PVC pipe
and accessories erected concealed in
wall/ceiling complete
Point wiring for on board Looped Plug
with 6A Modular type switch & 5 pin
socket erected on PVC /
Metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate modules
erected on / in wall / ceiling with
following type accessories
Point wiring for Two Way Controlled
Light Point with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (green) both are of
.ISI marked 1.1 KV grade
ZHFR/HRFR PVC insulated multi
strand copper wires erected in below
type of pipe with 6A Modular type
switches and following type of
accessories erected on PVC /
Metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate modules
erected on / in wall / ceiling as per
pipe erected. with necessary
batten/angle holder or ceiling rose or
H.D.Connector as directed.
(f) with medium class Rigid PVC pipe
6.00 and accessories erected concealed in 627.90 Pt
wall/ceiling complete
Providing following type of Modular
Type Accessories mounted with PVC /
metallic/Wooden box, single mounting
base frame covered with textured /
metallic/white front plate , modules
erected with necessary connections
as per site situation directed by
Engineer In charge.
1.7.2 60.00 (2) One No 5 pin plug 150.00 E.a.
1.7.3 60.00 (7) Blank Plate Single 25.00 E.a.
1.7.4 32.00 (8) Computer RJ-45 socket 159.00 E.a.
1.7.5 4.00 (9) 16 Amp. SP one way switch 179.00 E.a.
1.7.6 4.00 (10) 6/16Amp. Universal socket 198.00 E.a.
pole Modular MCB Switch
Double Pole Modular MCB Switch
Providing and erecting ISI mark
Medium class RIGID PVC PIPES of
following size complete to be erected
on/in wall or ceiling erected with
necessary PVC fittings & Junction
boxes fixed with adhesive solution &
Clamps with following dia of pipes, in
approved manner as directed
Providing & erecting PVC Corrugated
1.9 Flexible Conduit with required nos. of
coupling, PVC bushes, Check-nuts
etc. complete of following sizes.
providing and erecting Mains with ISI
marked electrolyte stranded copper
conductor, Non PVC Zero Halogen
free fire retardant insulated copper
1.10 conductor, insulated wire (HRFR)
conforms to IS-694, erected in
existing pipe with 1.5sq. mm copper
conductor of same specifications for
earth continuity of following size.
In Existing medium class Rigid PVC
pipe and accessories
providing and erecting Mains with
KV grade FRLS PVC insulated ISI
marked stranded Copper conductor
wire in following type of pipe to be
1.11 erected in / on wall / ceiling with
sq. mm copper conductor FRLS PVC
insulated stranded wire of green
colour for earth continuity of following
(A) with medium class Rigid PVC pipe
and accessories
(use earth wire of 4 sq.mm )
providing and erecting Mains with ISI
marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor
with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected
in existing pipe of following size
(Specifically for control panel, relays,
power switchgears, motor starters &
control wiring) with required size of
copper lugs, nuts and bolts if required.
1.12.1 20.00 (e) One wire 6.00 sq. mm 56.00 Mtr
1.12.2 20.00 (f) One wire 10.00 sq. mm 91.00 Mtr
1.12.3 10.00 (g) One wire 16.00 sq. mm 141.00 Mtr
1.12.4 5.00 (h) One wire 25.00 sq. mm 234.00 Mtr
1.12.5 40.00 (i) One wire 35.00 sq. mm 298.00 Mtr
1.12.6 10.00 (j) One wire 50.00 sq. mm 466.00 Mtr
Supplying and erecting Flexible PVC
insulated multi strand multi core 1.1 kv
1.13 grade ISI marked copper wires of
following size to be erected as
1.13.1 80.00 e) 1.50 Sq.mm 3 core round PVC 46.00 Mtr
1.13.2 40.00 h) 2.50 Sq.mm 3 core round PVC 77.00 Mtr
1.13.3 20.00 k) 4.00Sq.mm 4 core round PVC 175.00 Mtr
Supplying & erecting M.S. Box having
16 Gauge painted with red oxide or
1.14 Heavy duty PVC box erected flushed
on wall or concealed in wall with
necessary plastering & finishing as
directed of following size.
Supplying and laying UPVC cable
trunking system comprising
unplasticised polyvinyl, chloride rigid
material with ignition free and flame
1.15 proof confirming BS with necessary
end caps Internal and external bend,
flat bends, coupler, tee etc..All
necessary accessories and measuring
of following sizes
1.15.1 5.00 (2) 100 mm x 50 mm trunking 424.00 Mtr
(4)100 mm x 50 mm trunking with
1.15.2 5.00 TWIN compartment With clip in 1309.00 Mtr
Supply & installation of surface
mounted U PVC snap-on adaptable
trunking raceways, fabricated out of
U-PVC to Off-White or approved
shade as per IS 733 of thickness
1.16 2.0mm for the base and sides with all
accessories like removable covers,
joints ,height spacer,angles complete
with necessary bends, suitable sized
junction boxes and tees etc,
(a)Size: 50x80mm PVC Raceways for
5.00 Power & Data with 2 compartments 1052.00 Mtr
above specifications.
Supply & installation of modular type
accessories for U PVC snap-on
1.17 adaptable trunking/Pop up Box with
required items erected with
necessary connection. As desired by
Engineer In charge
1.17.1 4.00 i) 6 A SP 1 Way Switch 204.00 No
1.17.2 2.00 ii) 16A SP 1 Way Switch 351.00 No
1.17.3 4.00 iv) 6A universal socket shuttered 347.00 No
1.17.4 2.00 iv) 6/16 A universal socket shuttered 458.00 No
1.17.5 2.00 vi) Cat-6 LAN Socket 561.00 No
Supplying & erecting approved make
Telephone Cable electrolytic copper
conductor PE insulation twisted in two
pairs, & wrapped with FRLS PVC
tape & sheathed with FRLS PVC or
HFFR outer Jacket suitable for
telephone wiring & confirming to C-
DOT erected in existing pipe. of
following size of conductors & nos.of
pairs. With necessary connections.
(b) Armoured [Jelly Filled]
30.00 1) Ten Pairs 124.00 Mtr
1.19 LAN NETWORK
SITC of CAT6 UTP 24AWG PATCH
CORD:1M,Plug 30U' Snag less
(Including Five year free maintenance
with guarantee)
SITC of CAT6 UTP 24AWG PATCH
CORD:2M,Plug 30U' Snag less
(Including Five year free maintenance
with guarantee)
1.20 LAN SWITCH
SITC of 24 x 10/100/1000BASE-T
ports 4 x Gigabit RJ45/SFP Combo
ports Advanced L2 switching and
1.20.1 2.00 security features L2+ Static Routing 15247.00 No
Optional “standard mode” or
“surveillance mode” management
SITC of Patch Panel UTP Keystone-
1.20.2 2.00 24 Port- Unloaded (Cat 5e,Cat 6 & 1485.00 No
Cat 6 A ) (Including Five year free
maintenance with guarantee)
Providing & erecting main Distribution
1.21 (MDF) indoor type, back mounted
frame as per DoT standard approved
with krone strips
1.00 (a) Suitable for 10 pair 985.00 E.a.
Providing & Erecting Netwrok rack
with following capacity with Necessary
1.22 cooling fan,Cable manager,6A
PDU,equipment rack with necessary
mounting accessories.
Supplying & erecting approved make
1.23 LAN cable of following size in existing
pipe as per direction
SUB - TOTAL OF INTERNAL
2 Switchgears , Panels , MCBDBs &
Providing and erecting Approved
make Four pole moulded case circuit
breaker having breaking capacity ICU
of 35 KA. at 415 V. having Normal
current rating 200A.with variable
2.1 Thermal & magnetic release suitable
to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned
copper & complete erected in existing
16 G.M.S.housing. Overload release
Range: 84 - 125Amp
2.00 ICS=100% of ICU only 17667.10 No
Providing and erecting Approved
make Four pole moulded case circuit
breaker having breaking capacity ICU
of 35 KA. and above at 415 V .
having normal current rating 250A.
with variable thermal & magnetic
release suitable to work on A.C.supply
50 c/s. with all internal connections,
spreader tinned copper & complete
erected in existing 16 G.M.S. housing.
Overload release Range: 108 -
1.00 ICS=100% of ICU only 22812.90 No
2.3 FABRICATION AND BUSBARS
Fabricating the box type items made
from M.S. Sheet with A.I. supports,
wings, doors, handles other hardware
materials as per requirement design
2.3.1 18.00 with finishing by three tank powder 179.00 Kg
coating processed inside and outside
painted, erected as directed including
minor civil work. to install above
Providing and erecting busbar
chamber confirming to IS-375
fabricated from 16 G.M.S. sheet, dust
& vermin proof having hinged door
with rubber gasket and necessary
busbar supports with COPPER
busbar having current density not
more than 1.6 Amp. / sq.mm (Rated
current / cross section area) duly
wrapped with colour insulation tape
for phase sequence, three phase &
neutral each suitable for following
current capacity with necessary
painting mounted on wall or pedestal
frame of required size with necessary
1.50 (C) Suitable for 300 Amp. capacity 8455.00 RnMtr
providing and erecting Approved
make Earth fault Relay suitable to
mount with inter connection suitable to
following size of moulded case circuit
2.3.3 breaker having CT ratio & MCCB
rating as following along with shunt
trip 220V AC. with all internal
connections & complete erected in
existing M.S.housing..
Design, fabrication, assembling,
supply, installation, testing and
commissioning of cubicle type, wall /
Floor mounted LT panel suitable for
415 V 3 phase, 4 wire 50 Hz AC
supply system fabricated in
compartmentised design from CRCA
sheet steel of 2 mm thick for frame
work ,Doors and partitions IP 42 and
covers,3 mm thick for gland plates i/c
cleaning and finishing complete 9 tank
process in house facility for powder
coating in approved shade,
extendable type FP aluminium alloy
busbars of high condectivity,
DMC/SMC busbar supports, entire
panel shall have a common copper
2.4 earthbar of size 25mm X 5 mm at the
rear with 2 Nos. earth studs, solid
connection from main busbar to
switchgears with require size of
aluminium busbar & control wiring
with 1.5 sqmm FRLS insulated copper
conductor cable, cable alleys, cable
gland plates i/c accessrories as per
specification and providing
switchgears, metering instruments
etc. for following panel.G.A.Drawing to
be approved by EIC or consultant. (
Outgoing connectors must be nut-bolt
type. Outgoing mains for 63Amp
MCBs must be of 4 x 16sqmm cu
flexible wires).Incomers Mains for
MCBs shall be always from the
( a ) Providing cable clamps /
supports within distribution boards
( b ) All hinged door shall be earthed
through 2.5 sq mm tinned b raided
( c ) Pad locking of MCCB’s handles
in “OFF” Position.
( d ) All the C.T.s should be auto short
( e ) All the MCCB's should be with
( f ) All incoming and outgoing air
circuit breakers shall be placed on
middle portion of the vertical in single
tier formation.
( g ) Any descripancy found in SLD &
Boq , it should be brought in the
notice of the client / consultant, and
the decision will be taken final by
Client / consultant.
Providing and erecting Approved
make Four pole moulded case circuit
breaker having breaking capacity ICU
of 35 KA. at 415 V. having Normal
current rating 200A.with variable
2.4.1 Thermal & magnetic release suitable
to work on A.C.supply 50 c/s. with all
internal connections, spreader tinned
copper & complete erected in existing
16 G.M.S.housing. Overload release
Range: 84 - 125Amp
1.00 ICS=100% of ICU only 16061.00 No
providing and erecting Approved
make Earth fault Relay suitable to
mount with inter connection suitable to
following size of moulded case circuit
2.4.3 breaker having CT ratio & MCCB
rating as following along with shunt
trip 220V AC. with all internal
connections & complete erected in
existing M.S.housing..
providing and erecting Miniature
circuit breaker single pole 0.5A to 2A
system and having breaking capacity
10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI
providing and erecting Miniature
circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C.
2.4.5 4.00 system and having breaking capacity 111.00 No
10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI
Providing & erecting 240 V MCB
double pole switch for motor &
inductive load (C Curve) having
KA breaking capacity & confirms to IS
: 8828 in existing box having following
Providing & erecting 415 V MCB Four
Pole for Motor & Inductive Load (C
2.4.7 Curve) having 10KA breaking capacity
& confirms to IS :8828 in existing box
having following capacity
Providing and erecting following
2.4.8 additional parts for panel mounting
(A)Extended operating rotary handle
with pad lock with three position
trip,off,on suitable for 25A to 250 A
Supplying and erecting approved
make panel mounting type Digital
Voltmeter having 3 digits LED display,
2.4.10 1.00 0 to 750 AC Volts range erected on 1263.00 No
existing panel board with all
connection, wiring etc .with
manufacturers calibration certificate.
Supplying and erecting approved
make panel mounting type Digital
Ammeter having 3 digits LED
display, external CT operated,
2.4.11 1.00 calibrated for 0 to 1000 Amps suitable 1543.00 No
to operate on 500 Volt AC , erected
on existing panel board with all
connection, wiring etc .with
manufacturers calibration certificate.
Supplying and erecting Ammeter /
2.4.12 2.00 Voltmeter selector switch for 3 phase 314.00 No
AC Supply 500 V on existing panel
board with necessary connections.
Providing & erecting L.T. Current
Transformer with bar primary 50/5 to
2.4.13 6.00 1000/5 ratio 15 VA burden erected in 272.00 No
existing CRCA box duly secured with
insulating materials connected to the
Supplying & erecting approved make
Power Factor Meter 150mm dia
flush/projection type/ balanced &
unbalanced load to work with
2.4.14 1.00 appropriately provided CT’s 100/5A to 5052.00 No
400/5A ratio & other accessories
complete erected in M.S. box &
connected to the circuit by means of
PVC copper Core leads.
Supplying and erecting approved
2.4.15 6.00 make suitable panel indicator LED 43.00 No
type lamp, lens cover, complete
erected with necessary connections.
Providing and erecting metallic
vitrified danger notice board as per
language suggested by engineer
incharge for MEDIUM VOLTAGE
installation to be erected as per IS-
Providing and erecting required size
Aluminium strip for earthing of H.T.
2.4.17 2.00 OCB / ACB / Transformer, LT panel 223.00 KG
board, Motors etc. using copper
Providing and erecting required size
2.4.18 3.00 Copper strip for earthing of H.T. OCB 787.00 Kg
/ ACB/ Transformer, LT panel board,
Motors etc. using copper clamp.
providng and erecting Approved make
energy meter 3 phase 4 wire
2.4.19 1.00 unbalanced load 500 V. 5 to 10A 2179.00 No
complete erected as directed with
necessary earth wire.Class-1
Providing , erecting , fabricating the
M.S. structure as per requirement on
site incorporating proper size of M.S.
angles,square,round, flats, bars,
channels, sections complete with
2.4.20 90.00 cutting, welding, grinding & finishing 77.00 Kg
duly painted with one coat of red
oxide with erection on site as per
direction of engineer in charge with
necessary grouting, cementing,
plastering & finishing complete.
Supplying and erecting triple pole &
neutral 440V / 500V panel mounting
Copper Busbars with four equal Nos.
of electrolyte bus having current
density not more than 1.6 Amp. /
sq.mm (Rated current / cross section
area) duly wrapped with colour
insulating tape for phase sequence of
following current carrying capacity,
erected with necessary bus bar
supports /insulators, main cable
socket to each bar, erected in existing
cubical panel with necessary
4.00 (B) Suitable for 200 Amp. capacity 3171.00 RnMtr
Providing & erecting weather proof,
dust & vermin proof, floor mounted
front operated indoor type cubical
panel board necessary IP-42 and
above protection as per approval
from engineer incharge made from
SWG thick CRC M.S. sheet for outer
2.4.22 body & doors, 16 SWG thick CRC
M.S.sheet for internal partitions with
necessary accesories , supporting
angles/ flats channel including
cutting, bending, drilling, welding,
riveting with internal partitions & cable
alley as per requirements & instruction
of engineer-in-charge with erection of
supplied switch gears, BUSBARS,
suitable size of inter connecting PVC
copper wire / copper-aluminium strips,
rubber grommets, rib, bakelite control
fuses/MCB for measuring
instruments, earth bus & earth bolts,
foundation flange - bolts-base Plates,
sufficient nos. of hinged doors,
handles with locking arrangement and
rubber gasket,heavy duty end terminal
connection,danger notice
board,necessary ventilation,earthing
strip complete. The Panel shall be
painted with epoxy powder coating.
(The rates excludes the cost of
switchgears, bus bars, inter
connecting mains & Copper
Aluminium strips, meters, Fuses etc.
The dimension shall be measured
excluding base beams) The panel
shall be supplied with following
approved manufacturers with
following size.
(B) The standard companies switch
gear shall be used and only
manufacturers at CPRI approved
3.00 (i) with 350mm depth 14755.00 Sqmtr
Supplying & erecting
XLPE(IS:7098)(I)-88 ISI unarmoured
copper cable 1.1 KV grade to be
erected as directed of following size.
a (N) 4 core 16 Sq. mm
b (M) 4 core 10 Sq. mm
c (L) 4 core 6 Sq. mm
d (C) 2 core 6 Sq. mm
e (B) 2 core 4 sq.mm
providing and erecting Mains with ISI
marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor
with heat resistant PVC insulated
conforms to IS 694, IEC - 227 erected
in existing pipe of following size
(Specifically for control panel, relays,
power switchgears, motor starters &
control wiring) with required size of
copper lugs, nuts and bolts if required.
a (a) One wire 1.00 sq. mm
b (b) One wire 1.50 sq. mm
c (c) One wire 2.50 sq. mm
Design, fabrication, assembling,
supply, installation, testing and
commissioning of cubicle
type,20KVAR, Voltage Rating 415V
2.4.25 1.00 A.C.,3-Phase , APFC Panel having 5- 110035.00 No
steps ( 2x1 -3x1 -5x3 kvar heavy duty
can type capacitors ) with suitable
rating of Incomer MCB, CT. as per
approved by engineer incharge.
Supplying & erecting approved make
IP 55 grade Company fabricated
Timer Panel of following capacity for
switch On-Off street lights on time
scheduling basis made from 16G
CRCA sheet duly epoxy power
painted inside and outside with hinged
2.4.26 doors and locking arrangement
consisting of suitable size of 4 Pole
MCB and 4 pole contactor (cat-III)with
analog time switch, auto manual
switch of same make and suitable
input and output Bakelite terminals
and with door earthing approved by
Engineer in charge.
MCBDBs and MCBs
providing and erecting Miniature
circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C.
2.5 150.00 system and having breaking capacity 111.00 E.a.
10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI
Providing & erecting 240 V MCB
double pole switch for motor &
inductive load (C Curve) having
KA breaking capacity & confirms to IS
: 8828 in existing box having following
Providing & erecting 415 V MCB Four
Pole for Motor & Inductive Load (C
2.7 Curve) having 10KA breaking capacity
& confirms to IS :8828 in existing box
having following capacity
Sheets steel powder coated enclosure
2.8 4.00 suitable for incorporating One/Two 175.00 E.a.
Providing and erecting Sheet Steel
powder coated MCB distribution board
- flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN
2.9 rail, Conforms to IS 8623-1 & 3, IEC
61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs
should be used of same company of
MCB to be used) suitable for
(A) single phase incoming and
horizontal single phase outgoing
(b) sheet steel double door (IP-43)
2.9.1 4.00 (i)4 way ( concealed manner ) 747.60 E.a.
2.9.3 4.00 (iii)8 way ( concealed manner ) 1369.20 E.a.
2.9.5 3.00 (iv)12 way ( concealed manner ) 1773.60 E.a.
(B) three phase incoming and single
2.10 phase horizontal type outgoing Per
phase isolation type (PPI)
(b) sheet steel double door
2.10.1 4.00 (i)4 way ( concealed manner ) 2779.20 E.a.
2.10.3 3.00 (ii)6 way ( concealed manner ) 3462.00 E.a.
2.10.5 5.00 (iii)8 way ( concealed manner ) 4054.80 E.a.
Supplying & erecting Sheet Steel
powder coated Cable end termination
Box to be mounted on Top or Bottom
2.11 of the MCB Distribution Box for
housing/covering Extra wires &
Cables, suitable for following size of
2.11.1 8.00 (G) Three Phase 8 Way ( concealed 819.60 E.a.
2.11.2 8.00 (G) Three Phase 8 Way 683.00 E.a.
providing and erecting Approved
make ELCBs / RCCBs conforming to
IS: 12640 and having sensitivity of
mA and Short Circuit withstand
capacity of 10 KA and suitable for
2.12 operation on single phase
V,50Hz. having characteristic of quick
action & tripping with all advance
feature & do not incorporate any
electronic component. for following
Max. rating erected as directed
Providing and erecting metallic
vitrified danger notice board as per
language suggested by engineer
incharge for MEDIUM VOLTAGE
installation to be erected as per IS-
Providing & erecting Medium Voltage
Danger Notice Board sticker as per
2.14 15.00 language suggested by engineer 26.00 E.a.
incharge of standard size as per IS-
SUB - TOTAL OF Switchgears ,
Panel and MCBDBs.
Follow IS code :3043 is the guideline
for the earthing
Providing and erecting required size
HOT deep Galvanised iron strip for
3.1 180.00 earthing of H.T. , OCB/ ACB/ 77.00 KG
Transformer LT panel board, Motors
etc. using proper clamp.
Providing and erecting required size
3.2 15.00 Copper strip for earthing of H.T. OCB 787.00 KG
/ ACB/ Transformer, LT panel board,
Motors etc. using copper clamp.
3.3 15.00 Providing and erecting Annealed bare 787.00 KG
Copper wire 8 to 16 SWG.
Providing and erecting HOT deep
3.4 45.00 Galvanised iron strip wire 8 to 16 77.00 KG
Supplying & erecting earth pit of
minimum bore dia.150mm size
approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion
free hot dipped G.I.Pipes having
Outer pipe dia of 50mm having 80-
200 Micron galvanising, Inner pipe dia
of 25 mm having 200-250 Micron
galvanising, connection terminal dia of
12mm with constant ohmic value
surrounded by highly conductive
compound with high charge
3.5 dissipation suitable for following type
of applications with chamber and
heavy duty cover.(approved make
OEM has to submit test certificate) &
having back filling compound of (B)
Inner chemical (CCM Compound)-
Resistivity:- 0.2 W/ meter testing as
per IEC 62561-2017, Voltage drop:- <
1 volt at no load & dry form, Sulphar
content:- <2%(C) Back fill Compound
:- Earthing compound should be
capable to retain moisture for long
time Necessary test report must be
(a) For Electrical Installation up to
440V in normal soil
3.5.1 3.00 Length of pipe - 1 Mtr 4546.00 E.a.
Back filling compound - 1 Nos Bag of
(c) For Electrical Installation covering
Transformer Neutrals, Lightning
arrester Earthing, A.C.Plant &
Sensitive Computer System(like
3.5.2 1.00 Automation, SCADA) i.e independent 8551.00 E.a.
Earthing in normal soil.
Length of Pipe : 3.00 mtrs
Back filling Compound :2 nos Bags of
Supply, installation,testing and
commissioning of Chemical Earthing
with UL Certified 17.2mm Dia. X
3000mm Long 254 Micron-Copper
bonded M.S. Rod manufactured as
3.6 2.00 per IEC 62561-2 with 25Kg Bentonite 12230.00 No
powder plus " U " bolt rod clamp
complete with Lockable high
performence chamber suitable &
tested for 5000T capacity with SS
Hardware.or equivalent
SUB - TOTAL OF Earthing
4 CABLES, Cable Termination and
Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium
4.1 conductor for 1.1 KV. to be laid on
wall with necessary clamps or in
existing trench / pipe of following size
Sq.1/2 mm core)
Providing and erecting XLPE
(IS:7098)(I)-88 ISI armoured cable
multistrand / Solid Aluminium
4.2 conductor for 1.1 KV. to be laid on
wall with necessary clamps or in
existing trench / pipe of following size
Providing and erecting XLPE
(IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for
1.1 KV. to be laid on wall with
necessary clamps or in existing trench
/ pipe of following size of cables
Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper conductor
4.4 for 1.1 KV. to be laid on wall with
necessary clamps or in existing
trench / pipe at road crossing or floor
of following size of cable.
Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand / Solid Copper
conductor for 1.1 KV. to be laid on
wall with necessary clamps or in
existing trench / pipe at road
crossing or floor of following size of
Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper conductor
4.6 for 1.1 KV. to be laid on wall with
necessary clamps or in existing
trench / pipe at road crossing or floor
of following size of cables.
20.00 (C) 4 core 10 Sq. mm 670.00 Mtr
Making trench in soft soil of suitable
width of 90 cm deep for laying cable
4.7 190.00 or locating the fault all over the run 55.00 Mtr
and back filling the same and making
the surface as normal ground.
Covering of cable with second class
bricks or cement tiles laid cover the
cable crosswise & also on both sides
with covering of 7. 5 Cm. layer of sand
above & below cable (16 bricks per
( A )Making trench in Hard Murrum /
Tar Road of suitable width of 90 cm or
4.9 15.00 required depth for laying any size of 74.00 Mtr
cable or locating the fault all over the
run and back filling the same and
making the surface as normal ground.
4.10 5.00 (B) If additional machinery like 354.00 Mtr
hammer driller or JCB use [Add]
Drilling the road without breaking the
road surface (Asphalt) for laying of
4.11 cable for feeding power supply by
making up to following size of holes at
both ends complete.
4.11.1 5.00 (A) Up to 100 mm bore dia 488.00 Mtr
4.11.2 5.00 (B) Up to 150 mm bore dia 610.00 Mtr
Supplying following size of Light duty
4.12 “A” Class G.I . Pipe & erecting as
directed by Engineer-in-charge.
10.00 (A) 25 mm dia 171.00 Mtr
Providing & laying. R.C.C. Hume pipe
for cable to be laid 90 cm. below
ground across the road crossing or on
floor with necessary material in an
approved manner and making the
ground as per original.
Providing & laying approved make
Double walled corrugated pipes
(DWC) of polyethylene(conforming to
IS 14930 II )with necessary
4.14 connecting accessories of same
material at required depth in existing
trench for laying of cable. below
ground / road surface for enclosing
4.14.1 90.00 (A)50 mm outer dia 62.00 Mtr
4.14.2 200.00 (B)63mm outer dia 73.00 Mtr
4.14.3 50.00 (C))90 mm outer dia 95.00 Mtr
4.14.4 40.00 (D)120 mm outer dia. 136.00 Mtr
Providing & laying approved make
ISI marked Rigid PVC pipe having
6Kg / cm2 (Class-3) to be erected at
4.15 road crossing on or floor as directed
for laying of cable. The pipes as
following size of dia & weight per
4.15.1 15.00 (D) 75 mm inner Dia. (5.5 Kg/6RMT) 124.00 Mtr
(F) 110 mm inner Dia. (11.63 Kg/6
Providing and, fixing heavy duty
flange type brass cable gland with
rubber ring for PVC insulated
armoured cable complete with out
going tails, insulating tape etc for
following size of cables.
Providing and, fixing heavy duty
flange type brass double compression
type cable gland with rubber ring for
4.17 PVC insulated armoured cable
complete with out going tails,
insulating tape etc for following size of
Solder less crimping type Aluminium
lugs conforming to IS suitable for
cable of following size evenly crimped
4.18 with high pressure tool & connected to
switchgear terminals with
brass/cadmium plated nut bolts in an
approved manner.
Solder less crimping type Copper lugs
conforming to IS suitable for cable of
following size evenly crimped with
4.19 high pressure tool & connected to
switchgear terminals with
brass/cadmium plated nut bolts in an
approved manner.
Providing and fixing approved make
Perforated C type cable tray. Made
from sheet steel. The cable tray
should be single or double bended as
per required and as per IS 2062/1079
and shall be coated with hot dip
4.20 galvanizing as per IS 2629/4759. with
max 17.5% perforation with coupler
plate / Fish plate and GI hardware like
nut - bolt and washers etc. erection
with necessary support( included) as
per Specification and as per
instruction of engineer in charge..
SUB - TOTAL OF Cables,Cable
Terminations & Cable Trenches
5 Light Fixtures & Fans
Supply , Installation, testing and
commissioning of pre-wired, LED
fitting/post top luminaries etc of all
types, complete with all accessories
and tube etc. directly on ceiling/ wall,
including connection with 1.5 sq. mm
FRLS PVC insulated, flexible, copper
conductor, single core cable with
flexible conduits and coupler and
earthing etc. as required. Note:- The
LED Light fixtures should comply all
international standards third party (
LM 79 for complete fixture, LM 80 for
individual LED ). The Manufacturer /
Channel Partner of the Manufacturer
has to submit 4- Years unconditional
free Replacement Guarantee for
complete fixture.
Supplying and erecting LED indoor
fittings with LEDs of wattage 0.2 Watt
to 0.5 Watt assembled on single
MCPCB, with housing used as a heat
sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA/
aluminium die cast powder coated
and high U.V. & corrosion resistance
with diffuser with company
mark/name 160V to 270V, Power
Factor more than 0.95, THD <
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %( fitting
required LM-79 & LM-80
Certificates)(NOTE: Below description
have shown ranges of Wattage
capacity of LED fittings.The Engineer
incharge may select any wattage
capacity between the ranges shown.)
5.1.1 ( A ) Tube Light with integral / non
integral driver
5.1.1a 25.00 (iii) 18-20 Watts, Surge - 2KV,IP-20, 293.00 No
conventional 2/ 4 feet
5.1.1b 65.00 (v) 36-40 Watts, Surge-2 KV, IP-20, 530.00 No
conventional 4 feet
(B) LED Panel Light with provision for
5.1.2 Plane front frame with translucent
cover fixed to housing complete.IP20
5.1.2a 4.00 (i)up to 8 Watts,4" x 4", Surge-2 KV 271.00 No
5.1.2b 100.00 (iii) 12-15 watts, 6" x 6", Surge-2 KV 462.00 No
(iv) 18 to 20 watts, 8" x 8", Surge-
5.1.2d 40.00 (vi) 36 watts, 24" x 24", Surge- 2KV 1777.00 No
(G) Spot Light 425 Lumens, Surge-
5.1.4 2.00 (H) Mirror Light 9 Watts, wall mounted 309.00 No
minimum 1 feet long
(I) Adjustable spot light with COB led
5.1.5 having aluminium reflector of following
Providing & erecting Approved make
Power Saving 50 Watt Ceiling Fan
with double ball bearing ISI mark with
Condenser 230 volt A.C. 50 Hz
5.2 60.00 mm sweep complete having 3blades 1929.00 No
with aluminium blades with , canopy &
30 cm. down rod erected with
earthing.(Make shall be approved by
Engineer in charge))
Providing & erecting Approved make
Ceiling Fan with double ball bearing
ISI mark with condenser A.C.230V
5.3 15.00 50c/s. 1400 mm. sweep complete, 1721.00 No
canopy erected on existing hook or
clamp with earthing [ Make shall be
approved by Engineer in Charge]
Providing & erecting Approved make
Ceiling Fan with double ball bearing
with Condenser 230 volt A.C.50 Hz.
5.4 1.00 900 mm sweep complete having 3 1963.00 No
Aluminium blades, canopy erected
complete. [ Make shall be approved
by Engineer in Charge]
Supplying and erecting approved
make oscillating type medium duty
bracket fan with Aluminium Blades
A.C. 23OV. 50cy/s wall mounted with
height adjustment and rotary tilting
device complete with guard, mounting
accessories kit, pull cord for speed
and oscillation flexible Core plug top
complete erected with lead wires as
directed. 400MM.
Supplying & erecting approved make
low noise decorative exhaust fan
5.6 30.00 having size 200mm with 1350 RPM 1687.00 No
with square frame ABS body with
inbuilt lowers & square frame.
Supplying & erecting approved make
230 V , 50 Hz Operating Voltage low
noise decorative Roof Mounting
5.7 Exhaust fan having square frame and
Slitted guard with mounting
accessories, necessary pipings and
Supplying & erecting fan hook box of
10 mm M.S. round bar bounded to the
RCC bars up to 50mm length each
5.8 76.00 side and pierced through a 16 Gauge 107.00 No
M.S. box / Heavy Duty PVC box
complete erected concealed in Ceiling
with necessary finishing.
Providing 2.5mm.thick laminated
5.9 76.00 acrylic sheet to cover the fan hook or 18.00 No
Supplying and erecting 19 / 20 mm.
nominal bore Medium Class M.S. Pipe
5.10 76.00 down rod erected duly painted for fan 107.00 Mtr
complete with proper insulation
without leakage and earthing.
Supplying & erecting single phase
approved make industrial exhaust fan
5.11 suitable for medium duty ring mounted
low noise operation suitable for
medium duty having following dia size
and maximum speed in RPM
5.12 1.00 Providing suitable M.S. louver shutter 365.00 No
of the Exhaust fan.
Supplying & erecting electro
galvanised G.I. wire micro mesh jali
cover of grade 304 required size with
suitable wooden frame duly fitted in
wall outside of exhaust fan for insect
Providing and erecting PVC body
surface or pendent mounting LED
Bulk type 9 watt Lighting Fitting with
electronic driver. And lumen output
from luminaire 720lm , input voltage
range 90-300VAC , 50Hz cool
white(3000 to 6500k), inbuilt driver, -
20degC to +60degC working
temperature, AL frame with Beam
SUB - TOTAL OF Light Fixtures &
6 External lighting
Supply , Installation, testing and
commissioning of pre-wired, LED
fitting /post top luminaries etc of all
typesof external lights, complete with
all accessories and tube etc. directly
on pole / pole bracket , including
connection with 1.5 / 2.5 sq. mm
FRLS PVC insulated,3 core flexible,
copper conductor, with flexible
conduits and coupler and earthing etc.
Supplying and erecting LED street
light / Flood light fittings with High
power White LEDs wattage of 3 Watt
and above assembled on single
MCPCB, efficiency more than
lm/w and corrosion free High pressure
die cast aluminum housing with
smooth finish powder coated and heat
sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with
toughened glass with company
6.1 mark/name engraved or embossed
160 to 270 V,Power Factor more than
5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt .
LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80
certificates)(NOTE: Below description
have shown ranges of Wattage
capacity of LED fittings.The Engineer
incharge may select any wattage
capacity between the ranges shown.)
(A) Street Light (IP-65), Surge
protection -4KV /5000K integral and
10 kv non integral ,Light must have
440VAC line supply protection. It
should withstand 48 hours for
440VAC line supply.
10.00 (f) Above 60 watts to 90 watts ( 5917.00 No
(B) Flood Light (IP-65), Surge -
4KV/5000K ,Light must have 440VAC
6.1.2 line supply protection. It should
withstand 48 hours for 440VAC line
6.1.2.a 4.00 (c) Above 60 watts to 100 watts 6028.00 No
6.1.2.b 4.00 (v) above 120 to 160 watts 8370.00 No
Supply of approved make frp/grp pole
having followiing specifications :
FRP/GRP pole made by centrifugal
moulding process using thermoset
resin polyester/epoxy resin system
having minimum glass content
45.0%.The pole should be in one
pieceand tapered round in
shape,having smooth outside surface
finish and should be totally fre from
corrosion as well as non conductive
and shock proof. Pole should be
provided with FRP/GRP base bracket
6.2 dully fabricated from metal(M.S) and
dully claded with FRP/GRP material to
avoid any metal exposer and painted
Pole should mechanical properties i.e
1. Specfic gravity (ASTM D 792) 1.3‐
1.8 Kg/m3, 2. Glass Content % by
weight (ASTM D 2584) 45.0 ‐55.0%,
3. Water absorption (ASTM D 570)
<0.5%, 4. Tensile Strength(ASTM D
638) 200+/‐50Mpa, 5. Flexural
strength (ASTM D 790) 250+/‐50Mpa,
6. Compressive Strength (ASTM D
695) 200+/‐50MPa, 7. Yeild
Strength(ASTM D638) 250 +/‐50MPa.
Pole should be flame retardant as per
IS 6746.Resin used shall be UV
resistance and pigmented. Pole
should be painted with first coat of
epoxy primer and then two coat of
highly weather resistance polyurethen
paint to ensure proper addhesion of
the paint.Minimum thickness shall be
80 to 100 micron.Defelection of the
pole shall not exceed more than
% of the length of the pole for the
given load.Pole should be generally
made as per the dimensional
data,performance criteria and some
interchagebility features of poles as
per the standard ANSI C123.20 latest
version of ASTM D 923/01 including
cable termination box with necessory
accessories.The size of pole and type
of installation with foundation , Anchor
Base & Internal junction box as per
the manufacturer details and site
requirement . The cost of 6 Mtr &
Mtr pole's Flood light mounting ring is
(3) 'B' class (Heavy Duty) frp/grp pole
suitable for base plate mounting
[D] Overall Length of 6.0 meter,
Average thickness : 7mm, Top/Bottom
Outside Dia. 76/176mm +/‐2.Weight of
Pole 25.0 Kg approx. (Without base)
Metal Anchor Base dully frp claded
(Size : 340 Ø * 12mmthk , Mounting
hole PCD 285mm * 6 nos. of 20 Ø
Providing FRP/GRP arm bracket of
having 15˚ arm with 50 mm OD pipe
*5 mm thk,1000mm long from pole
6.3.1 8.00 (a) Single arm bracket 1882.00 No
6.3.2 1.00 (b) Double arm bracket 2390.00 No
Supplying & erecting sintex make
SMC press moulded composite FRP.
loop-in, loop-out approx. 2mm thick
box complete with bakelite connector
6.4 2.00 strip 4way & hinged doors having 472.00 No
locking arrangements with mounting
clamp with nuts, bolts & washers
suitable for erection on wall (
c)150mm x 125mm x 100mm [deep].
Providing cement concrete.for
foundation or for concrete filling in
1:2:4 ratio with 20 to 25 mm stone
metal duly plastered with necessary
curing for pole muffing or any other
B' class galvanised iron pipe 32 mm
outside dia 45 cms long duly welded
on 20 cms x 20 cms x 3 mm thick
6.6 2.00 M.S. base plate, erected on wall or 340.00 No
corner for mounting street light
luminaire with necessary hardware
materials duly painted.
SUB - TOTAL OF External Lighting
Supplying & erecting approved make
Automatic liquid level controller 6A.
with sensor testing as per instruction
7.1 1.00 of Engineer in charge on site 2332.00 Job
complete with wiring connection with
existing wires , with copper conductor
from pump to upper and lower tank.
Supplying and erecting Flexible PVC
insulated multistrand multicore 1.1 kv
7.2 grade ISI marked copper wires of
following size to be erected as
90.00 e) 1.50 Sq.mm 3 core round PVC 46.00 Mtr
Providing and erecting ISI mark
Medium class RIGID PVC PIPES of
following size complete to be erected
on/in wall or ceiling erected with
necessary PVC fittings & Junction
boxes fixed with adhesive solution &
Clamps with following dia of pipes, in
approved manner as directed .
Providing & erecting water cooler
having storage capacity 150 Ltr. &
cooling capacity 150 Ltr.per hour @
an ambient temp of 45˚ C. The outlet
temp. of the water should drop by
15˚C within a hour, The water cooler
7.4 3.00 should be comprising of hermetically 55340.00 No
sealed compressor, fan motor,
condensing unit, water tank
surrounded by evaporating, coil,
thermostats, relay etc.complete with
necessary inlet & outlet connection.
The body of water cooler will be made
from Stainless Steel.
Supplying and erecting water filter
cum purifier with ultra violate
7.5 3.00 technology. (Aquaguard / waterdoc 5371.00 No
model or equivalent symphony/
crystal/videocon model)
Providing & erecting open well
7.6 horizontal mono block pump set with
cast iron body, complete for three
phase submersible motor having
[D] For 5 HP 3 phase open well
horizontal mono block pump set
7.6.1 1.00 suitable for 1350 LPM to 310 LPM @ 18561.00 No
10 to 42 Mtr head suitable for 50/65
mm dia delivery pipe
[C] For 3 HP 3 phase open well
horizontal mono block pump set
7.6.2 2.00 suitable for 85 LPM to 270 LPM @ 11 15552.00 No
mtr to 33 mtr head suitable for 50/65
mm dia delivery pipe
Supplying & erecting approved
make motor control cubical panel
(Direct - on - line) made from 16 G.
CRCA sheet duly epoxy powder
painted inside and outside with hinged
doors and locking, arrangement
consisting of suitable size of ON- OFF
isolator (AC - 3/23duty) main fuses,
single phasing preventer, indicating
lamps for R- Y - B phases, overload
relay, Automatic water level controller,
Ammeter, Voltmeter each with two
way selector switch incoming, wires
duly socket crimped, main contactor &
overload relay, start - stop push
buttons, to be erected on angle iron
frame grouted on wall as directed.
The isolator, overload relay &
contactors will be of L & T, Siemens
or BCH make only.
2.00 (a) DOL up to 5.0 H.P. 7646.00 No
Supplying & erecting approved make
3 phase motor control cubical panel (
Star - Delta) made from16 G. CRCA
sheet duly painted with epoxy powder
painted inside and outside with hinged
doors and locking arrangement,
consisting of suitable size of ON- OFF
isolator (AC - 3/23 duty) main fuses,
single phasing preventer cum water
level. Guard (Complete unit), Toggle
switch to by pass Single phase
preventer cum WLG, indicating lamps
for R- Y- B phases, over load relay,
Automatic water level controller,
Ammeter & Voltmeter each with two
way selector switch incoming wires
duly socket Crimped, Panel to be
erected on angle iron frame grouted
on wall as directed. Star Delta & main
contactor, overload relay, thermal /
Electronic Star delta cutoff timer, start
- stop push buttons. The isolator
overload relay & contactors of L& T,
Siemens or Cuttler Hamer make only.
Panel to be erected on angle iron
frame ground on wall.
2.00 (A) S/D up to 7.5 H.P. for sewerage 12865.00 No
pump in basement
Charges for doing liasioning work for
obtaining the necessary clearances
from the Electrical inspector /
competent Authorities for the total
Electrical installation,co-ordinating
with various agencies. All necessary
drawings, calculations, test
certificates, etc. as required by these
7.9 1.00 authorities shall be prepared and 25423.73 No
furnished by the EPC Vendor. Any
modification/rectification as required
by these authorities shall be carried
out by theEPC Vendor at free of cost.
The fees required to be paid to these
authorities for inspection shall be
borne by Owner on production of
documentary evidences.
7.10 online Un-interruptible Power Supply
Supplying and erecting approved
make online Un-interruptible Power
Supply system comprising flat cum-
boost charger with IGBT base rectifier
& Inverter & sealed maintenance free
SMF batteries. The charger having
operating capacity for input 160-270V
AC & inverter having output 230V,50
Hz Ac with 0.8 load power factor with
battery, over/under voltage output with
over load & short circuit protection
equipment. The system housed in
CRC sheet duly powder coated paint
with following power backup.with MS
painted batteries stand, 10% Overload
capacity for momentary load.
1.00 [E] 6 KVA with 1Hr Backup 177211.00 No
SUB - TOTAL OF MISC. Work
8 PASSENGERS ELEVATOR
Supply ,installing , commissioning and
testing of M.R.L. Passengers
Elevator 8 to 10 passengers as per
R & B S.O.R ( Category - Premium )
having following specifications:-
Ground+ 3 upper floor
Supplying, Erecting, Testing &
Commissioning the passenger lift
having following main features:
[1] GEAR LESS LIFT DRIVE
comprising of High Starting torque Lift
3 phase 440 V A. C. Permanent
Magnet Synchronous motor of proper
rating with high efficiency shall be
[2] Micro processor based / PLC,
ACVVVF, vector control drive with
encoder feedback closed loop system
shall be used for lift car and door
operation which shall be full collective
selective operation hall call demand
response, UP/DOWN hall stops, Main,
Up/ Down Contactor with overload
and phase reversal relay and safety
[3] Car with M S platform with
bracings of adequate size and to
sustain the impact load cabin +
passenger with safety factor of fire for
steel and side panels of Stainless
steel of sheet of grade 304 duty. Car
ceiling will be S.S. finishes with
aesthetic appearance with LED ceiling
lights. Car flooring shall be of anti skid
PVC with choice of colour of engineer
in charge. Car doors shall be of
stainless steel grade 304, hairline
finish with centre opening / telescopic
automatic doors. Car panel will also
be S.S. 304 finished with emergency
stop device, mechanical door safety
device, facility of auto/ attended
mode. All car panel buttons and all
floor switches must be with brail
language as per lift act.
[4] All landing doors must be fire rated
for 2 hour shall be fully automatic
centre opening/ telescopic opening
made of hairline finish steel grade of
304 with key holes and infrared
curtains with Unlocking facility from
[5] Appropriate battery operated
emergency light in the car along with
alarm switch shall be provided. Also,
Emergency Light & Fan should start
immediately without any Time Delay
as soon as power fails.
[6] Digital scrolling indicator system
for up-down arrow along with floor
position indicator shall be provided
inside the car and at all floors.
[7] Full height infra red curtain with
multiple cross / crossing light beams
shall be provided.
[8] Automatic Rescue Device (ARD)
shall be provided accordingly of
passenger capacity with Manual
Rescue Operation ( Manual Cranking
[9] Audio visual indication in the lift car
showing over loading shall be
provided such that doors kept open till
excess load is removed.
[10] Spring buffers/PU Buffers shall be
[11] Car fan as per passenger
capacity with automatic sleep timer
shall be provided.
[12] Voice annunciator with suitable
music shall be provided in lift car.
[13] Self diagnostics system for
operational and safety parameters
shall be provided in control panel.
[14] Mechanical over speed governor
with governor calibration as per actual
site parameters and submission of
calibration certificate submission, door
key holes in the floor doors, fireman
switch shall be provided.
[15] Lift machine hoisting arrangement
in the lift machine room and monkey
ladder for lift pit should be provided by
the lift agency, along with the other
steel structure works, foundations for
the machine etc…
[16] In the hoist way fascia plate shall
be provided without any extra cost,
where ever required as / if directed by
engineer in charge.
[17] Permanent wiring with necessary
safety devices like RCCB in all circuit,
Over Voltage Under Voltage
protection and THD eliminator in
circuit for lift machine room and lift
well with proper numbers of light
points, with fixtures, exhaust fan and
plug points shall be provided by the
agency. Only 3 phase Power Supply
shall be made available by
department in lift machine room.
Necessary Earthing as per Lift
Act/Rules shall be arranged by Lift
[18] Any civil/ electrical works for
additional and alteration in lift shaft
and machine room related to erection
of lift shall be made by lift agency
without any extra cost. (granite/marble
fixing around all landing door
openings are not in lift agency’s
[19] Agency has to provide all working
drawings and documents and liaison
services for obtaining all necessary
permission from lift inspector and
other authorities.
[20] acrylic transparent licence/display
A4 size holder in lift car
[20A] As per statutory requirement of
Govt. Of Gujarat lift & escalator act
2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at
4.carrying out third party lift
inspection during/after lift erection and
provide report by third party
authorized by concern licensing
authority 5.agency has to provide
third party insurance upto completion
of free maintenance period and
submit the document for the same.
[21] Car Panel Operating Buttons with
floor position indicator/buttons must
be of Auto Glow type clearly visible
when view from inside cabin.
[22] For Physically Handicapped
person Full Length Handrails of
hairline finish steel grade of
should be provided at appropriate
height on the Rear & Side Wall
Panels in Lift Car.
[23] With Necessary KVA rating
voltage controlled Stabilizer suitable
for your controller, drive and all
equipments of lift.
[24] Necessary rating of DP Elcb and
FP Elcb required for lift is in scope of
work which rating is sugested by
CEICED Department (electrical
(B) SPECIAL FEATURES
DESCRIPTION OF LIFTS for
PREMIUM category
1. Advanced control system dual
bit embedded microprocessor with
CANBUS Serial Communication mode
including Regenerative power efficient
operation,on site programming facility,
Anti nuisance, Pte-opening,
BMS/RMS with necessary online real
time monitoring system having
necessary connectivity for remote
monitoring & other suitable
supporting hardware & software
devices to fulfil the purpose.
2. Floor Indication LCD Display with
call registration & brail mark with
arrival gong and hall lantern & TFT
Screen in the car with MP3 Voice
3. CAR Panel should be Scratch
resistive SS Moonrock finish / Hair
Line / Honeycomb for car and all
Doors, All landing doors must have
fire rating up to 2 hours and car door
must have multi-level crisscross beam
door protection.
4. To & fro communication system &
wiring (i.e. car , control room & guard
room ) and Each elevator are
equipped with remote monitoring
system.agency has to provide mobile
app and user id and password for
8/10 passengers Ground + 3 upper
floors with Rated Speed of
AMC LOGO design as per given by
department to be embossed inside the
lift car wall opp. To door.
(C) With General PLUS ADDITIONAL
1.00 SPECIAL FEATURES attached 1560017.00 No
herewith. Prem. Cat.
SUB TOTAL of Passengers
Providing and erecting approved
make split air-conditioning unit
consisting of copper condensing unit
with fan motor, hermetically sealed
rotary compressor with accessories
etc. duly connected separately
9.1 erected evaporating unit and blower
motor with its accessories by means
of extra supplied proper insulated
copper tubing,drain PVC pipes
suitable for ( cost includes powder
coated Stand, Eco Friendly green gas
charging, 15A plug top & Remote
Control) with necessary core cutting.
(1)For ISEER Range (KWH/KWH)(3.1
to 3.99) Premium Category
9.1.1 1.00 [a] For 0.8 to 1.0 Ton Capacity 38986.00 No
9.1.2 5.00 (b) for 1.5 ton capacity 51923.00 No
9.1.3 5.00 (c) for 1.7 to 2.0 ton capacity 58706.00 No
Supplying and installing MS angle
powder coated / Painted standard
type of wall/floor stand mount for
outdoor unit of split AC of following
capacity, erected with necessary
hardware materials as directed.
(A) 25mm*25mm*3mm thick M.S
9.2.1 6.00 angle suitable for upto 2 TR. Capacity 1305.00 No
(B) 35mm*35mm*5mm thick M.S
9.2.2 5.00 angle suitable for above 2 TR to 4 TR 1496.00 No
Capacity of ac machine
Supplying and erecting insulated pair
of soft copper tubing including power
9.3 110.00 and control cable,necessary PVC 956.00 RMT
drain pipes for Split AC machine up to
Rigid UPVC drain pipe of 10 Kg/cm2.
9.4 rating with 9 mm thick.nitrile rubber
Supplying & fixing 50mm thick TF
quality expanded polystyrene for
9.5 105.00 underdeck insulation on slab/wall 409.00 Sqmtr
/shaft exposed to sun/atmosphere as
per specifications.
SUB TOTAL of HVAC WORK
10 COMPREHENSIVE Maintenance
Annual Comprehensive Type
Maintenance Contract of
ELECTRICAL + HVAC System and
passenger Elevator For 1-Year DLP +
Annual comprehensive Type
10.1 1.00 Maintenance Charges only During FREE Year
Guarentee / Defect Liability period.
Annual comprehensive Type
Maintenance Charges for 1st Year
after Guarentee / Defect Liability
SUB-TOTAL Of ANNUAL
Comprehensive Maintenance
contract Of Electrical /HVACand
passenger Elevator
I. No. Qty Items Unit Rate Per Amount
Final specification and block diagram
shall be submitted by CCTV camera
SITC of 1/2.8" CMOS 3MP IP Fixed
Lens IR rugged DOME Camera
having progressive scanning system
Pixels 3MP (2304 x 1296),Lens
mm, Fixed, F1.4, Minimum
Illumination color / BW: Color:
Lux @ F1.6, BW 0 Lux IR ON,IR
Distance 40 Mtrs,Wide Dynamic
Range 130 Db,Privacy Masking
Off/On (5 Areas),Local Storage Micro
SD/SDHC/SDXC card slot (2TB),Gain
Control 0 ~ 100%,Angle of View (H x
V) H:87.2° V:49.1°,Ethernet 10 Base-
T/100 Base-TX Ethernet (RJ-
45),Protocols:IPv4, IPv6, TCP/IP,
1.1 20.00 HTTP, HTTPS, RTSP/RTP/RTCP, 13222.00 No
IGMP/Multicast, SMTP, SNMP,
DHCP, NTP, DNS, DDNS, CoS,
QoS,802.1X, UPnP, mDNS(Bonjour),
UDP, ICMP, ARP, TLS, SFTP,Body
Material Aluminium +
Polycarbonate,Number of Video
Streams 4,Ingress Protection IP66,
IP67, Event Notifi cation HTTPS,
HTTP, SMTP, ONVIF, Bit Rate 100 K
~ 6 Mbps Certificates: FCC PART
CE (EN 55032), ICES-003,CE (EN
55035),UL listed to UL/CSA 62368-1,
BIS IS 13252 (Part 1)/IEC 69050-
1,RoHS, REACH, WEEE,BIS ER,
SITC of 1/2.8" CMOS 3MP IP Fixed
Lens IR rugged Bullet Camera having
progressive scanning system , Pixels
3MP (2304 x 1296),Lens 3.6 mm,
Fixed, F1.4, Minimum Illumination
color / BW: Color: 0.002 Lux @ F1.6,
BW 0 Lux IR ON,IR Distance
Mtrs,Wide Dynamic Range
Db,Privacy Masking Off/On (5
Areas),Local Storage Micro
SD/SDHC/SDXC card slot (2TB),Gain
Control 0 ~ 100%,Angle of View (H x
V) H:87.2° V:49.1°,Ethernet 10 Base-
T/100 Base-TX Ethernet (RJ-
45),Protocols:IPv4, IPv6, TCP/IP,
1.2 6.00 HTTP, HTTPS, RTSP/RTP/RTCP, 13222.00 No
IGMP/Multicast, SMTP, SNMP,
DHCP, NTP, DNS, DDNS, CoS,
QoS,802.1X, UPnP, mDNS(Bonjour),
UDP, ICMP, ARP, TLS, SFTP,Body
Material Aluminium +
Polycarbonate,Number of Video
Streams 4,Ingress Protection IP66,
IP67, Event Notifi cation HTTPS,
HTTP, SMTP, ONVIF, Bit Rate 100 K
~ 6 Mbps, Certificates: FCC PART
CE (EN 55032), ICES-003,CE (EN
55035),UL listed to UL/CSA 62368-1,
BIS IS 13252 (Part 1)/IEC 69050-
1,RoHS, REACH, WEEE,BIS ER,
Supply , Installation , Testing and
commissioning of 32 Channel NVR
(Network Video Recorder) Embedded
Linux based for recording upto 32CH
at 1080P, 960fps with 04 nos. SATA
HDDs minimum 40TB storage or more
(recording requirement all cameras
recording at 2MP, 25fps for 30 days),
H.265 HEVC/H.264/MJPEG codec
decoding, Front Panel with LEDs
Indication for Power & HDDs Status,
nos. USB, ONVIF S, Time Sync with
NTP, Encrypted Streaming & Control,
2-Way Audio Line & Out, PTZ
Operation Pan, Tilt, Zoom, Support,
Pre & Post Alarm Recording Support,
Recording/Evidence Clip Export to
USB, 16 Channel Synchronous
Playback, Playback control i.e Play,
Pause, Stop, Fast Forward,
Backward, Speed Control, Timeline &
Zoom; Snapshot, Web Client, Central
Monitoring Software, iPhone; iPad;
Android based Mobile clients, 02HDMI
& 01VGA Output, 04 On Board HDDS
each up to 10TB, Alarm Input (16
nos.), Alarm Output (04 nos.),
RS232/485, eSATA, 256 Mbps
throughput, NDAA Section
Compliant, Operating Temperature –
10°C to 55°C, Certification :
Certifications: ONVIF compliant,
FCC Part 15, EN 55032, NDAA &
RoHS (EN63000) compliant. Including
fixing accessories and cable
termination with required
connectors/Jack, complete in all
respect as per instruction of engineer
Supply Installation Testing &
1.4 2.00 Commissioning of 8TB Surveillance 25150.00 No
Supply, Installation, Testing and
Commissioning of 43 inch,
Professional LED Display Cum
Commercial TV with Android 11 &
Inbuilt play store, UHD resolution,
1.5 1.00 nits brightness, It's 24*7 usage, 53465.00 No.
50,000 hours life, 3 years warranty,
Android 11 with inbuilt play store,
Inbuilt wifi, Landscape / Portrait mode,
Inbuilt Bluetooth, 2 GB / 16 GB
Memory, Inbuilt SOC with HDMI cable
Providing and erecting ISI mark
Medium class RIGID PVC PIPES of
following size complete to be erected
on/in wall or ceiling erected with
necessary PVC fittings & Junction
boxes fixed with adhesive solution &
Clamps with following dia of pipes, in
approved manner as directed
CAT 6 UTP Cable
Supplying & erecting approved make
1.7 LAN cable of following size in existing
pipe as per direction
Supply, Installation, Testing &
1.8.1 1.00 Commissioning of 9U wall mount 12053.57 No
1.8.2 3.00 3U wall mount Rack 5025.01 No
SITC of 24 x 10/100/1000BASE-T
PoE ports 4 x Gigabit RJ45/SFP
Combo ports Advanced L2 switching
and security features L2+ Static
1.9 1.00 Routing Optional “standard mode” or 31680.00 No
“surveillance mode” management
user interface 193 W PoE budget
(Including Five year free maintenance
with guarantee)
SITC of 8 x 10/100/1000BASE-T PoE
ports 2 x Gigabit SFP ports Advanced
L2 switching and security features L2+
Static Routing Optional “standard
mode” or surveillance mode”
management user interface 65W PoE
[Approved by Competent Authority i.e.
not Below the rank of Executive
Supply, Installation Testing &
Commissioning 5 Mtr. HDMI Interface
Cable as per the detailed
Specifications supports transmission
of 4K Signals as per the detailed
Supply, installation, fixing, testing and
commissioning of PVC Junction box
for CCTV Camera, IP65, outdoor
application. Junction Box size will be
as per vendor's requirement and site
SITC of Patch Panel Cat 6 UTP
Keystone Type- 24 Port-Fully Loaded
(Including Five year free maintenance
with guarantee)
SITC of Jack Cat 6 Keystone UTP
1.14 26.00 (Including Five year free maintenance 160.00 No
with guarantee)
SITC of CAT6 UTP 24AWG PATCH
CORD:1M,Plug 30U' Snag less
(Including Five year free maintenance
with guarantee)
SUB -TOTAL OF CCTV SYSTEM
2 COMPREHENSIVE Maintenance
Annual Comprehensive Type
Maintenance Contract of CCTV
System For 1-Year DLP + ONE Year
Annual comprehensive Type
2.1 1.00 Maintenance Charges only During FREE Year
Guarentee / Defect Liability period.
Annual comprehensive Type
Maintenance Charges for 1st Year
after Guarentee / Defect Liability
SUB -TOTAL OF CCTV
Comprehensive Maintenance work
I. No. Qty Items Unit Rate Per Amount
FIRE FIGHTING SYSTEM
Design,Drawing,
Supply,installing,testing and
commissioning of FIRE HYDRANT
Internal / External Hydrant
Supplying, Installation, Testing and
Commissioning of electric driven main
Hydrant fire pump suitable for
automatic operation and consisting of
following: complete in all respect as
a) Horizontal type, single stage,
centrifugal, end suction pump of cast
iron body & bronze impeller with
stainless steel shaft, mechanical seal
to ensure a minimum pressure of
kg/sq. cm. at highest and farthest
outlet at specified flow of 1680 lpm at
56 Mtr. head conforming to IS
1520.with suitable size of footvalve
confirming to IS 4038, Pressure rating
PN2 , preventing entry of foreign body
to pump through suction pipe,
perfectly flat seating surfaces for good
a) Horizontal type, single stage,
centrifugal, end suction pump of cast
iron body & bronze impeller with
stainless steel shaft, mechanical seal
to ensure a minimum pressure of
kg/sq. cm. at highest and farthest
outlet at specified flow of 2280 lpm at
65 Mtr. head conforming to IS
1520.with suitable size of footvalve
confirming to IS 4038, Pressure rating
PN2 , preventing entry of foreign body
to pump through suction pipe,
perfectly flat seating surfaces for good
b) Suitable HP Squirrel cage induction
motor, TEFC, suitable for opertion on
415 volts, 3 phase 50 Hz. AC with IP
55 class protection for enclosure,
horizontal foot mounted type with
Class - 'F' insulation, conforming to IS-
c) M.S. fabricated Common base
plate, coupling, coupling guard,
foundation bolts etc. as required.
d) Suitable cement concrete
foundation duly plastered with anti
vibration pads.
The pump shall be capable of giving
not less than 150% discharge at
ahead not less than 65% of the rated
Supplying, Installation, Testing and
Commissioning of electric driven
pressurisation pump suitable for
automatic operation and consisting of
following: complete in all respect as
a) Horizontal type, single stage,
centrifugal, end suction pump of cast
iron body and bronze impeller with
stainless steel shaft, mechanical seal
at specified flow of 180 lpm at 56/70
m. head conforming to IS: 1520.with
suitable size of footvalve confirming to
IS 4038, Pressure rating PN2
preventing entry of foreign body to
pump through suction pipe, perfectly
flat seating surfaces for good sealing.
b) Suitable HP Squirrel cage induction
motor TEFC type suitable for
operation on 415 volts, 3 phase
Hz. AC with IP 55 Class of protection
for enclosure, horizontal foot mounted
type with Class F' insulation,
conforming to IS :
c) M.S. fabricated Common base
plate, flexible rubber coupling,
coupling guard, foundtion bolts etc. as
d) Suitable cement concrete
foundation duly plastered with anti
vibration pads.
1.1.4 ENGINE DRIVEN PUMP
Supplying, Installation, Testing and
Commissioning of diesel engine
driven main fire pump suitable for
automatic operation and consisting of
following: complete in all respect as
a) Horizontal type, single stage,
centrifugal, end suction pump of cast
iron body and bronze impeller with
stainless steel shaft, mechanical seal
to ensure a minimum pressure of
kg/sq. cm at highest and farthest
outlet at specified flow of 2280 lpm at
65 m. head conforming to IS
b) Suitable HP, 1500 /1800 RPM
water cooled with radiator, diesel
engine conforming to relevant BS & IS
standard complete with auto starting
mechanism, 12/24 volts electric
starting equipment, 180 AH lead acid
battery with battery stand, exhaust
pipe extended upto 6 m. outside pump
house duly insulated with 50 mm thick
glass wool with 1.0 mm. thick
aluminium sheet cladding, residential
silencer, instruments and protection
as per specification, stop solenoid for
auto stop in the event of fault with
audio indications, painted with post
office red colour etc. as required.
c) One 200 Ltr capacity day oil
storage tank fabricated from 3 mm
thick M.S. plates. Tank shall be
provided with inlet, outlet, overflow, air
vent, drain connections, filling
connection & level indicator. Tank
shall be mounted on a suitable steel
structure (Painted with 2 coats of red
oxide paint). Tank shall be provided
with two or more coats of synthetic
enamel paint outside over two coats
of red oxide primer.
d) M.S. Fabricated Common base
plate, coupling, coupling guard,
foundation bolts etc. as required.
e) Suitable cement concrete
foundation duly plastered with anti
vibration pads.
1.00 A. Incoming Feeder:- 259210.00 No
MCCB with Thermalmagnetic Based
Releases having O/C, S/C ,E/F
protection, Digital ELR 96x96mm with
CBCT, FP Spreader Terminals 1 set=
8 Pcs, Extended Rotory Handle for
MCCB, 240V AC Shunt Trip coil for
(ii) LED type indicating Lamp with
suitable rating 2 Amp SP MCB:- 1 Set
(each set comprise of R,Y,B)
(iii) Digital type 3 phase Multi function
Meter with suitable rating of MCB &
Nos. of single core epoxy resin cast
type CTs of 200/5 Amps, 10 VA, CL
1.0 ratings -1 Set.
415 V, 200 Amps, FP Aluminium
Busbars with Heat shrinkable color
code insulation sleeves.
OUTGOINGS:-( All outgoing feeders
for pumps should have digital
Ammeter with selector switches and
LED type ON,OFF,Trip indicating
1 sets - 125 A, 25kA TPN MCCB,
Ics=100% Icu, with fully automatic
Star/Delta starter suitable for 50 HP
pump with overload protection, current
sensing type single phase preventor
complete with all acceessories and
internal wiring required for automatic
operation,selector switch for
local/remote, auto/manual/OFF
1 sets - 125 A, 25kA TPN MCCB,
Ics=100% Icu, with fully automatic
Star/Delta starter suitable for 50 HP
pump with overload protection, current
sensing type single phase preventor
complete with all acceessories and
internal wiring required for automatic
operation,selector switch for
local/remote, auto/manual/OFF
1 no.63A,16KA MCCB
Ics=100%,Extended Rotry handle
with TM release having O/C & S/C
protection with 10 HP fully automatic
star/ delta starter , current sensing
type, Single Phase Preventer,
ON/OFF Push Button & LED type
Indicating lamps complete with all
accessories and internal wiring
required for automatic operation,
selector switch, for local/remote,
auto/manual operation
Diesel Engine Control.
Control for Diesel Engine comprising:
i) Auto/Manual selector switch &
attempt starting device, timers and
relays as required, push buttons,
start/stop in manual mode.
ii) LED type Indication lamp for
High/Low Lub. Oil pressure, High
Water Temp and Engine ON
iii) Battery charger suitable for 12 V/24
V DC with boost and trickle selector
switch, 0-30 V DC volt meter, 0-20
Amp DC Ammeter.
iv) All standard relays, accessories for
automatic operation of diesel engine,
wiring with 1.5 sq mm PVC insulated
copper wire between various sensors
and system controller / starter,
suitable size cable for battery
charging etc. as required.
System Controller
Designing, Supply, Installation,
Testing and Commissioning of system
controller to control operation of Main
Electric Fire Pump, Diesel Pump,
Pressurisation Pump, Terrace Pump
in sequence as per specification
consisting of relays, timers, sensors,
annunciation window for fault
indication, control wiring complete as
3 NOS. 25A DP MCB " C " Curve
1.3 PRESSURE GAUGES , Air vessel
Providing, fixing, testing and
1.3.1 3.00 commissioning of Pressure Switch 1329.87 Set
with Needle Valve.
Providing and fixing in position the
industrial type pressure gauges with
gun metal / brass valves complete as
Providing, laying, testing &
commissioning of 'C' class heavy duty
MS Pipe conforming to IS 1239 i/c
fittings like elbows, tees, flanges,
tapers, nuts bolts, gaskets etc., in
ground including excavation and
providing cement concrete blocks as
support, anticorrosive treatment with
coaltar/asphalt tape as per IS
refilling the trench etc. of following
sizes complete as required .( For
Providing, laying, testing &
commissioning of 'C' class heavy duty
MS pipe conforming to IS 3589/IS
1239 including Welding, fittings like
elbows, tees, flanges,tapers, nuts
1.5 bolts, gaskets etc. and fixing the pipe
on the wall/ceiling with suitable
clamp/support frame and painting with
two or more coats of synthetic enamel
paint of required shade complete as
1.5.9 5.00 200mm Dia ( wall thickness 6.3mm ) 4938.01 Mtr
Supplying and fixing Single headed
internal / External hydrant valve with
No. 63 mm dia instantaneous FM
Gunmetal/Stainless Steel coupling
and cast iron wheel,ISI marked,
conforming to IS 5290 (type A) with
blank Gunmetal/Stainless Steel cap
and chain as required :
9.00 Single headed Stainless steel 5549.04 No
Providing, fixing, testing and
commissioning of Wall mounting
swing type first aid Fire Hose Reel
with drum, hanging bracket, 30 M x
mm dia high pressure hose reel tubing
as per IS:884 with shut nozzle and
ball valve and all required
Supplying, Installation, Testing and
commissioning of weather proof Fire
Hose cabinet size 900x 600x300mm
to house fire hydrant & hose,
including all other related
accessories fabricated from M.S.
sheet (16 Gauge) of fully welded
construction having front door with
locking arrangement, partially glazed
with 4 mm thick glass. Cabinet shall
be powder coated & painted with post
office red colour
Providing ISI marked RRL (IS :
type‐A) fire hose pipe 15 meter long
and 63 mm dia with ISI marked (IS :
1.9 16.00 903) Stainless steel male and female 4020.55 No
coupling bound and rivetted to hose
pipes with copper rivets and copper
wire complete as required.
Providing Stainless steel ISI marked
63 mm. dia. male Instantaneous
pattern short branch pipes with 20 mm
1.10 9.00 dia. Nozzle as per IS : 903, suitable 1502.28 No
for 10 Kg/sqcm operating pressure
and suitable for interconnections to
hose pipe coupling as required.
Supplying and fixing of fire brigade
connection of cast iron body with gun
1.11 metal male instantaneous inlet
couplings complete with cap and
chain as reqd. for suitable dia MS
pipe connection conforming to IS
1.00 2 way - 100 mm dia M.S. Pipe 6094.09 No
Providing, fixing, testing and
commissioning of 25 mm dia Air
1.12 2.00 Release Valve and Ball Valve 1949.25 No
assembly on top of each riser for Air
release system.
Providing, fixing, testing and
1.13 1.00 commissioning Pressure Relieaf 4940.68 No
Valve 25mm dia with Ball Valve.
Supplying and fixing orifice plate
made out of 6 mm thick stainless steel
(Grade 304) with orifice of required
size to be fitted between flange &
landing valve of external and internal
hydrants to reduce pressure at the
outlet to the level of 3.5 kg/cm2
complete as required.
Supplying, fixing, testing and
commissioning of butterfly valve of PN
1.6 rating with bronze/gunmetal seat
1.15 duly ISI marked complete with nuts,
bolts, washers, gaskets conforming to
IS 13095 of following sizes as
Providing, installation, testing and
commissioning of non-return valve of
1.16 following sizes confirming to IS:5312
complete with rubber gasket, GI bolts,
nuts,washers etc.as required :
Providing, installation, testing and
commissioning of stainless steel Y-
strainer fabricated out of 1.6 mm thick
stainless steel, Grade 304, sheet with
3 mm dia holes with stainless steel
Supply, Installation, Testing and
1.18 9.00 Commissioning of Brass. Ball Valves 737.27 No
with all fittings required. 25mm size
Supplying and erecting Flexible PVC
insulated multistrand multicore 1.1 kv
1.19 grade ISI marked copper wires of
following size to be erected as
f) 1.50 Sq.mm 4 core round PVC
1.20 4.00 SITC of fire pump start stop push 954.50 No
buttons in box.
SITC of 2 Zone standalone Fire
Alarm control Panel, 16X2
Character LCD Display, provision for
zone wise contact and sounder. Panel
1.21 1.00 does not have provision to connect 9300.00 No
Repeater Panel. Make: Ravel
Approval: CE Mark. (Including Five
year free maintenance with
Providing and erecting ISI mark
Medium class RIGID PVC PIPES of
following size complete to be erected
on/in wall or ceiling erected with
necessary PVC fittings & Junction
boxes fixed with adhesive solution &
Clamps with following dia of pipes, in
approved manner as directed
Supply, Installation, Testing and
Commissioning of Single action
Manual Pull Station.Shock and
Vibration Resistant, pull Down Lever
Remains Down Until Reset. Shall be
Polarity Insensitive (with all mounting
accessories , complete with Junction
Box for mooting on Surface, Cable
lugs at Ends, cable compression
glands, cable tags and ferruling.
Supply, Installation, Testing and
Commissioning of Conventional
Sounder cum strobe having tone
settings with range of 95dbA and field
selectable 15/30/75/110
candelas.(with all mounting
accessories , complete with Junction
Box for mooting on surface, cable lugs
at ends, cable compression glands,
cable tags and Ferruling.)
CABLES AND TERMINATIONS
Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper conductor
1.25 for 1.1 KV. to be laid on wall with
necessary clamps or in existing
trench / pipe at road crossing or floor
of following size of cable.
Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper conductor
1.26 for 1.1 KV. to be laid on wall with
necessary clamps or in existing
trench / pipe at road crossing or floor
of following size of cable.
Providing and erecting
XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper conductor
1.27 for 1.1 KV. to be laid on wall with
necessary clamps or in existing
trench / pipe at road crossing or floor
of following size of cables.
Providing and, fixing heavy duty
flange type brass cable gland with
rubber ring for PVC insulated
armoured cable complete with out
going tails, insulating tape etc for
following size of cables.
Solder less crimping type Copper lugs
conforming to IS suitable for cable of
following size evenly crimped with
1.29 high pressure tool & connected to
switchgear terminals with
brass/cadmium plated nut bolts in an
approved manner.
Providing and fixing approved make
Perforated C type cable tray. Made
from sheet steel. The cable tray
should be single or double bended as
per required and as per IS 2062/1079
and shall be coated with hot dip
1.30 galvanizing as per IS 2629/4759. with
max 17.5% perforation with coupler
plate / Fish plate and GI hardware like
nut - bolt and washers etc. erection
with necessary support( included) as
per Specification and as per
instruction of engineer in charge..
Supply, installation,testing and
commissioning of Chemical Earthing
with UL Certified 17.2mm Dia. X
3000mm Long 254 Micron-Copper
bonded M.S. Rod manufactured as
1.31 1.00 per IEC 62561-2 with 25Kg Bentonite 12230.00 E.a.
powder plus " U " bolt rod clamp
complete with Lockable high
performence chamber suitable &
tested for 5000T capacity with SS
Hardware.or equivalent
1.32 SEWAGE PUMPS
Supplying, Installation, Testing and
commissioning Sewage water
submersible pumping sets of CI
casing & impeller, SS shaft, including
1.32.1 2.00 with inbuilt water level sensors for 19676.50 No
operating the pumps automatically
and all accessories suitable for
operation on 220 V-240 V, single
phase, 50 Hz. AC supply etc. as reqd.
> 10 mm solid handling
capacity,Minimum Capacity -
LPM,Minimum Head > 13.5 Mtr
SITC of 5 HP sewage pump for the
basement designed for liquids which
are non-aggressive and non-
explosive, sewage / effluent water
with solids or fibers, pump shall have
non clog, semi open or closed type
impeller with material of construction
of cast Iron FG260, CF8 AND CF8M,
stainless steel shaft, suitable for
pumping liquid up to 50 degree C. The
Pump shall be supplied with double
mechanical shaft seal with material of
construction of SiC /SiC/Viton/S.S
1.32.2 2.00 at the pump end , close coupled with 60797.00 No
dry submersible motor, having class F
insulation, IP 68 protection, epoxy
sealed cable entry, with S1 duty for
fully submerged and S3 duty for
partially submerged, suitable for
phase, 415volts, 50 Hz power supply,
All cast iron parts shall be CED
(cathode electrode deposition) coated
for corrosion resistance with uniform
coating and controlled deposition
thickness of 20-30 microns. The pump
has 1500- 200 LPM at 5.8-16.2 Mtr
head with 1450RPM.
Charges of Preparing Design
Drawings ,Testing of Fire Fighting
1.33 1.00 System with necessary Approval from 76271.19 job
Local Fire authority.( Including Pre-
NOC and NOC from Fire authority. )
Providing, fixing, testing and
1.34 commissioning of below Auto Glow
1.34.2 4.00 Fire Equipment: 4" X 12" 514.97 No
1.34.3 4.00 In case of Fire, do not use lift, use 650.00 No
staircase: 8" x 8"
1.34.5 4.00 Fire Extinguishers 8"x 4" 480.00 No
1.34.7 4.00 Fire Hydrant 4” X 12” 514.97 No
1.34.8 4.00 Fire Hose Reel.4” X 12” 514.97 No
1.34.9 4.00 DCP Extinguisher 8"x 4" 480.00 No
1.34.10 4.00 CO2 Extinguisher 8"X 4" 480.00 No
Providing, fixing, testing &
commissioning of 15mm dia quartzoid
bulb type sprinklers of rating with
required accessories :
1.35.1 80.00 Pendent Sprinkler 57°C standard 362.25 No
response (K-80) UL Listed
1.35.2 10.00 Pendent Sprinkler 68°C standard 471.50 No
response (K-80) UL Listed
Supplying, installation, testing &
commissioning of sprinkler flexible
pipe (UL Listed) of stainless steel
complete with 15 NPT on reducer
thread with maximum working
pressure of 175 PSI test pressure of
1.36 875 PSI (Burst) with branch line (Inlet)
25mm NPT male thread to sprinkler
head (Outlet) 15mm NPT female
thread with reducer, nipple, 2 side
brackets,center bracket, stockbar of
following sizes complete as required
etc of following sizes as required:
Providing fixing, testing and
1.37 1.00 commissioning of Drainning & Testing 4939.25 No
Assembly 25mm dia with Sight Glass
Union joint , Ball Valve & Drain Valve.
SUB-TOTAL OF FIRE HYDRANT
2 FIRE EXTINGUISHERS AND
LIGHTNING ARRESTER
2.1 FIRE EXTINGUISHER
FIRE EXTINGUISHER Supplying,
Installation, Testing and
commissioning of Dry Chemical
Powder (DCP) 6 Kg Fire Extinguisher
Mono Ammonium Phosphate Powder
40, Stored Pressure Type, Pressure
2.1.1 4.00 Gauge, Controllable discharge 2724.25 No
mechanism Class A, Rating 3A &
Class B rating 21B as per IS
ISI MARK (ABC Dry Chemical Powder
- MAP 40%)fitted with required
accessories including wall suspension
Supplying, fixing, testing and
commissioning of CO2 type Fire
Extinguisher of capacity 4.5 kg filled
with Co2 Gas as per IS 15222 with
2.1.2 4.00 controll discharge mechanismfitted 6526.00 No
with Hose & Horn applicable on Class
B fire rating 21B confirms to IS
15683, bearing ISI mark. Co2
Cylinder as per IS
Providing & fixing of ISI marked water
CO2 type Portable fire extingusher,9
LTR capacity, Hydraulic test pressure
2.1.3 1.00 35Kgf/ cm2, Discharge range 2 3450.00 No
Mtr,Average discharge time: Min.
13Sec,Fire Rating 3A,Grade:
Providing & fixing of ISI marked,
Squeeze Grip Cartridge Type water
CO2 type Portable fire extingusher,9
LTR capacity, Hydraulic test pressure
35Kgf/ cm2, Discharge range
Mtr,Average discharge time: Min.
13Sec,Fire Rating 3A,Grade:
Providing,fixing, testing and
commissioning of 10Kg Modular type
fire extinguisher having Nitrogen
expellant ,ceiling mounted,Sprinkler
2.1.5 1.00 Nozzle is gas tight the release 2950.00 No
temperature is adjusted with sprinkler
imported bulb set at 57 degree C or
68 degree C ,coverage area 4 to
2.2 LIGHTNING ARRESTER
SITC of Vertical Air Termination Solid
aluminium with Base- 10 mm dia and
1000 mm long. Air Termination Base
tested for conditioning, Ageing Test &
Lightning impulse current withstand
test: 100 kA of 10/350µs waveform in
an accredited Third party laboratory
as per 6.3 & 6.4 of IEC 62561-1
protocol with MAST 34mm dia
mm long- Cold Galvanized
SITC of 8 mm dia solid Aluminium
Conductor for roof top mesh grid and
tested as per IEC 62561-
conducted in the Govt. accredited
thirty party laboratory to meet the
requirement of IS/IEC 62305 with
Required Accessories - Aluminium
Holding clamp at every 1 mtr distance,
Aluminium/SS cross splicer at every
crossing of Alu. conductor, Expansion
piece with connectors at every 20 mtr
2.2.2 130.00 distance, Aluminium straight Splicer to 297.00 Mtr
connect conductors. All Accessories
should be tested as per IEC 62561-1
2018 Cl. 6.3 for conditioning & Ageing
Test & 6.4 for Lightning impulse
current withstand test: 100 kA of
10/350µs waveform(Ageing &
Electrical test ) conducted in a
sequence manner & tested in the
Govt. accredited Third party
laboratory to meet the requirements of
SITC of Galvanized Steel Flat 25x6
mm thickness from earth electrode
directly in ground as required. Zinc
coating: 500 g/m square (Approx:70
micron coating) tested and used
exclusively for lightning protection
earthing system and ring equipotential
SITC of 14.2 mm dia 3 mtr long Earth
electrode of High tensile steel
electrode with 250 micron copper
bonding & 1 bag of Carbon fill Based
environment friendly backfill tested as
per IEC 62561-7 in NABL accredited
2.2.4 6.00 Laboratory and suitable stainless per set No
Steel double sided clamp. Eco
Friendly rust proof heavy duty weather
proof Polyethylene Earth Pit Chamber
with following dimensions :254 mm
dia (top), 330 mm dia (bottom) &
SUB TOTAL of FIRE EXTINGUISER
& Lightning Arrester
3 FIRE DETCTION & FIRE ALARM
Supply, Installation, Testing &
Commissioning of Microprocessor
based Networkable Analogue
Addressable Fire Alarm Control
Panel. The Panel shall be compliant
with EN54-2, EN54-4 and approved
by LPCB. The Fire Alarm Control
Panel shall have inbuilt 2 loops and
expandable capacity upto 8 loops.
The Panel must have Full colour
x 480 LCD with resistive touch screen
and automatic backlight dimming. The
Panel must also have the capability to
take Addressable Intelligent Wired
and Wireless Devices on same loop.
Each loop shall have a capacity of
127 analogue Addressable devices
and 127 Base sounders/Base
Sounder Beacons. The panel shall
have an event log of minimum
events @ 1 second resolution,
3.1 1.00 Filterable and Printable. The Panel 203348.75 No
shall have Three access levels. Panel
shall support upto 5000 Cause &
Effects entries, with upto
inputs controlling & 20,000 Controlling
outputs across the network. The
Panel shall have capability for Peer to
Peer networking through RS485
network card. The Panel must have
inbuilt programmable sounder circuits,
each circuit rated at 2.5A.The Panel
must have inbuilt 3 programmable
inputs and 5 inbuilt programmable
relay outputs. The Panel shall have up
to sub-addressable
programmable Inputs/Outputs via
optional RS485 COMMS serially
connected expansion cards. The
Panel shall have 240 V AC power
supply along with automatic Battery
Charger. The Panel shall be fully
expandable via common plug in loop
driver boards. The user shall have a
choice of using the panel with
Amp or 10.25 Amp power supply unit
which is inbuilt in the FACP and
should be approved to EN54-4. The
Panel shall have configurable via USB
port to PC or memory stick. The Panel
shall have dedicated RS232 serial
port for optional printer. Approved by
SITC of Analogue Addressable Multi-
Sensor which is fully compatible with
Analogue Addressable
Protocol,having removable high
performance chamber with Twin fire
LED's allow 360 degree viewing, User
selectable sensitivity modes 1% to
4.5% obs/m, Incorporate Optical and
dual Heat elements, lock mechanism
(sensor to base), Electronically
addressed, Pulsing/non-pulsing
controlled from panel. Approved by
LPCB & VdS. (Including Five year free
maintenance with guarantee)
SITC of Analogue Addressable Multi-
Heat Sensor which is fully compatible
with Analogue Addressable
Protocol,having removable high
performance chamber with Twin fire
LED's allow 360 degree viewing, User
selectable sensitivity modes 0 to
3.3 5.00 degree Celsius, Incorporates Fixed 3498.30 No
Temperature and Rate Of Rise Heat
elements, lock mechanism (sensor to
base), Electronically addressed,
Pulsing/non-pulsing controlled from
panel. Approved by LPCB (EN54: Part
5) (Including Five year free
maintenance with guarantee)
SITC of sensor common mounting
base, includes stainless steel
contacts, slim profile - only 8mm,
quick connection via square cable
clamps, facility for remote indicator,
Approved by LPCB (Including Five
year free maintenance with
Supply,Instllation,Testing and
Commissioning of Fault isolator
Module capable of monitoring shorted
loop circuit and automatically restore
communications when shorted
conditions are corrected (Including
Five year free maintenance with
Supplying, installation, testing &
commissioning of response indicator
3.6 40.00 on surface/recessed MS Box having 193.20 No
two LED, metallic cover complete with
all connections etc as required.
SITC of Manual Call Point approved
to EN54-11:2001, Approved by LPCB
3.7 4.00 Easy to install, push-fit wiring 4191.75 No
terminals (Including Five year free
maintenance with guarantee)
SITC of Analogue addressable loop
powered Base Sounder, variable
sound output 50 ~ 98 dB(A) (±2
dB(A)) output at 1 metre, 51 user-
3.8 4.00 selectable tones (all tones EN54-3 7442.80 No
compatible), Auto shutdown feature
prevents noise-pollution, Approved by
LPCB & VdS (Including Five year
free maintenance with guarantee)
Supplying & laying of 2x1.5 sqmm fire
alarm armoured cable, 600/1000V
rated with annealed copper
conductor having XLPE insulation,
steel wire armouring & FRLS outer
sheath complete as required.
SUB -TOTAL OF FIRE DETECTION&
Annual Comprehensive Type
4 Maintenance Contract of for Above
Fire Fighting System For 1-Year
Every six months Testing certificates
with Photographs should be sent to
competent authority by concern
Annual comprehensive Type
4.1 1.00 Maintenance Charges only During 1st 0.00 Year
Year DLP / Defect Liability period.
Annual comprehensive Type
Maintenance Charges for 1st Year
after Guarentee / Defect Liability
SUB TOTAL of Annual
Comprehensive Maintenance of
Fire Fighting Sytem
Window Curtains
Providing & Fixing in Position Vertical
Roller Blinds with Minimum 3 % and
Maximum 5 % Light Transperace
Screen Fabric Incuding Providing &
Fixing of Powder coated G- Channel
at the Topof Window with necessary
Screw , Cleats etc. and PVC Roller (
Weight Pipe) and PVC Chain For Up
1 120.00 and Down Movement of Blinds etc. of 1372.03 Sq.mt.
Approved Make and as per Drawings /
Instruction of Engg. in Charge For All
Colors and Shades. Rates Includes all
Lead and Lift For All Floor Level, All
Height , All Material , Accessories,
Fixing , Scaffolding , Labor etc.
Complete in All Respects. All
Required Accessories & Material must
be From Same Manufacturer.
Providing & Fixing Sun Control
Reflective Type Film / Frosted Film as
2 120.00 Selected by Architect/ Engg. In 646.37 Sq.mt.
Charge For Glass Doors / Windows
etc. as Directed.
Signature of Bidder
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT- NORTH ZONE
Name of Work : CONSTRUCTION OF WARD OFFICE BUILDING AT F.P.NO. 158 , T.P.S.NO. 65 -
SAIJPUR BOGHA IN THKKAR NAGAR WARD, NOTH ZONE, AHMEDABAD
FINANCIAL BID (Online Only)
Sr.No. Description Amount
1 Amount For Civil Work Rs.4,79,64,591.18
Amount For Electrical Work with Annual Operation & Comprehensive
Maintenance for 1 Years after completion of DLP of 1 Year Rs.
Amount For CCTV Work with Annual Operation & Comprehensive
Maintenance for 1 Years after completion of DLP of 1 Year Rs.
Amount For Fire Fighting System Work with Annual Comprehensive
Maintenance for 1 Years after completion of DLP of 1 Year Rs.
5 Amount For Window Curtains Rs.
I/We am/are willing to carry out work at ______% above / below (should be written in figures and words)
the estimated cost mentioned above.
Estimated cost put to tender : Rs.5,85,82,196.76 Estimated cost put to tender : Rs.5,85,82,196.76
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees _______________________ In words : Rupees_____________________
Signature of Bidder Additional City Engineer ( N.Z. )
Seal Ahmedabad Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender Notice 18 Tender No 2 NIT.pdf
Tender Notice 18 Tender No 1 Volume 1 Part A.pdf
NZ WO Vol-1 Part B TS Civil Work Dt. 17-02-2026.pdf
NZ WO Vol-1 part-C Electrical Specification Dt.17-02-2026.pdf
NZ WOVol-1 part-D CCTV Work Specification Dt.17-02-2026.pdf
NZ WO Vol-1 part-E Fire Fighting Specification Dt.17-02-2026.pdf
NZ WO Final Price Bid Vol.-II Dt.17-02-2026.pdf
TENDER DRAWING THAKKARNAGAR WARD OFFICE.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .