Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.8 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹51.6 L+₹6.6 L (14.7%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹70.0 L+₹25.0 L (55.6%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
2 Dec 2023, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
MAINTENANCE / REPAIRs TO DG SETS OF CAPACITY 25 TO 1010 KVA / HT DISTRIBUTION TRANSFORMERS / HT VCBs AND RMU AND HT OVERHEAD LINES / HT UG CABLES ALONGWITH CONNECTED WORKS AT AIR FORCE STATION BIDAR
2023_MES_625429_1
85603/E8
Open Tender
Civil Works - Others
Item Rate
270 days
GE AF BIDAR
AS PER NIT
9 documents required · 9 mandatory
₹1,000
GE AF BIDAR
₹1.1 L
Yes
1 Jan 2024
28 Oct 2023
4 Dec 2023
28 Oct 2023
2 Dec 2023
18 Nov 2023
28 Oct 2023 - 11 Nov 2023
Amount
Disconnection and removing HT cable connections connected to the HT VCB and carried out complete servicing and overhauling of 11/33 KV, 3 phase 50 Hz VCB of 630/800/1250 Amps capacity (drawnout / fixed type)n with CTC (carbon terminal cleaner) of all terminals complete to serviceable the HT switch gear including finding out the defective parts such as fixed male & female contacts, under voltage relays, power pack unit, spring charge motor, operating mechanism, gear box, CT & PT units, VCBs SF6 Bottles, Triping/ closing coil, HT Fuses, 11 KV LBS fix & moving arm and charging unit complete including calibration of relay duly integrate with connecting HT panels & VCB and reconnecting the cables testing and commsissioning of the following Makes as existing at site : MEGHAWIN/ AREVA/SIEMENS/ABB/Schenider Note : (1) Spring charge motor, Triping / closing coil, HT Fuses & moving arm and cast resin bushes etc measured spearately under respective item of the BOQ item No 2 to 16. (2) Miscelleneous items required for satisfactory completion of job deemed to be inclusive in the unit rate quoted.
Supply only Tripping coil DC 24/110 volts suitable for existing breakers complete all as specified and as directed. Make :- MEGHAWIN/ AREVA/SIEMENS/ABB/Schenider
Supply only Closing coil DC 24/110 volts suitable for existing breakers complete all as specified and as directed. Make :- MEGHAWIN/ AREVA/SIEMENS/ABB/Schenider
Supply only Spring charge motor 1.5 KW single phase for functional of HT VCB suitable for existing makes complete all as specified and as directed. Make : MEGHAWIN/ AREVA/SIEMENS/ABB/Schenider
Supply only current transformer suitable for existing breakers complete all as specified and as directed. Make :- Megawin or equvalent in AREVA/SIEMENS/ABB/Schenider
Supply only potential transformer model ECS11J conforming to IS 3156-1992, insulation class 'B' suitable for existing breakers complete all as specified and as directed.. Make :- Schneider or equvalent in AREVA/SIEMENS/ABB/Megawin
Supply only single phase under voltage or over voltage relay 20/110 V or 82/264V suitable for existing breakers complete all as specified and as directed. Make :- L&T or equvalent in MEGHAWIN/ AREVA/SIEMENS/ABB/Schenider
Supply only single phase over current or earth fault relay 20/110 V or 82/264V suitable for existing breakers complete all as specified and as directed. Make :- L&T or equvalent in MEGHAWIN/ AREVA/SIEMENS/ABB/Schenider
Supply multi function digital panel meter having the parameters the HT voltage,current, frequency, power factor , KVA, KVAR and short CCT current/fault level currenct sensor measurements etc suitable for operating voltage 24/110/230 volts complete all as specified and as directed. Make :- L&T (Micom relay)/CADLE/Socomech
Supply only HT barrel fuse 2 Amps suitable for 11 KV potential transformer of existing makes conforming to IS.complete all as specified and as directed.
Supply only HT barrel fuse 32 Amps Din type suitable for existing HT 11 KV breakers conforming to IS.complete all as specified and as directed.
Supply only HT barrel fuse 32 Amps BS type suitable for existing HT 11 KV breakers conforming to IS.complete all as specified and as directed.
Supply only plastic sleeve suitable for moving arm unit (male & female) type suitable for existing HT 11 KV breakers complete all as specified and as directed.
Supply only female contact made out of copper with silver coating type suitable for existing HT 11 KV breakers complete all as specified and as directed.
Supply only cast resin bush unit of suitable for existing HT 11 KV breakers along with copper studd duly coated with sliver plate for fixing of 11 KV bus bars along with suitable nut bolts and watchers complete all as specified and as directed.
Supply and fixing of Gear box of 11 KV HT VCB panel including taking out old U/S Gear box complete all as specified and as directed. Make :- Magawin or equivalent in AREVA/SIEMENS/ABB/Schenider
Supply and fixing power pack unit of capacity 230/ 24 Volts 3 phase and making necessary connection to PTs complete including taking out old U/S power pack unit complete all as specified and as directed. Make : - Power Pack or equivalent approved make.
Supply and fix trip circuit supervision relay VAX30-34V model No.VAX31ZG8043FCH make- Alstom including taking out old U/S relay complete all as specified and as directed. Make -:- Alstom or equvalent in L&T / MEGHAWIN / AREVA / SIEMENS/ ABB / Schenider
M&L for disconnecting HT cables for repair/servicing and overhauling of 11 KV ,400/630,20KA /3sec, Outdoor , Extensible type Ring main unit (upto 7 way) including dismantalling and reassembling the same, testing complete all as specified and directed by Engineer-in-charge. Note : - (i) Complete servicing and calibration of RMU (ii) Repair of Gear Box assembly. (III) Cleaning of Bus Bar through CTC and replacement of Bus Bar sleeves. (iv) Checking/ repair the tripping system. (v) Major item shall be measured and paid separately.
Supply only RMU protection relay Model CSDPR-V2 suitable for existing RMU complete all as specified and as directed. Make :- C&S or equvalent in L&T/ABB
Supply only master trip relay type PQ8nCH2J suitable for existing RMU complete all as specified and as directed.BU :- ABB or equvalent in L&T / Siemens / C&S
Supply only multi function meter model EN 8400 having the parameters the HT voltage,current, frequency, power factor , KVA, KVAR etcsuitable for existing RMU complete all as specified and as directed. Make :- Elmeasure or equvalent approved make.
M&L for disconnecting the transformer of capacity upto 315 KVA from the electrical system, taking out and shifting the same for repair to work shop, drain out old transformer oil, opening the top cover of the transformer with conservator and taking out core with limbs and primary & secondary windings after disconnecting and removing iron core, removing damaged primary & secondary windings etc as per requirement and rewinding the same duly insulating and removal of moisture on oven heating & re-assembling transformer winding and core heating including insulating and packing material in order to take out all moisture from the transformer assembly complete to serviceable, lowering the core assembly with winding in transformer body, connection work and re-assembling in position top cover, conservator, breather with relay control wiring complete including transportation of transformer back from workshop to site, installation of transformer on foundation, commissioning and testing complete all as specified and directed by Engr-in-charge. Note:- 1. Copper winding wire for rewinding will be measured in Kgs and paid sepertely under relevant of items of Sch A here in after. 2. Draining of transformer oil, filtering & dehydrating of oil and filling back if found usable in to the transformer shell and gasket and Misc items if any are deemed to be inclusive in the unit rate.
Supply Only copper winding, paper insulated wire complete as per existing guage for existing number of turns for LV coil/leg rewinding of transformer capacity upto 315 KVA complete all as specified and as directed
Supply Only copper winding, paper insulated wire complete as per existing guage for existing number of turns for HV coil/leg rewinding of transformer capacity upto 315 KVA complete all as specified and as directed
Disconnection and Removing the unserviceable/ burnt out Primary HT 11 KV Bushing units complete and replace the same with same size and capacity of bushing with brass Studs along with suitable nut bolt and washers complete suitable for the following Transformers :-
Transformer 11/0.433 KV , 50/63 KVA
Transformer 11/0.433 KV , 100 KVA
Transformer 11/0.433 KV , 160 KVA
Transformer 11/0.433 KV , 200 KVA
Transformer 11/0.433 KV , 250 KVA
Transformer 11/0.433 KV , 315 KVA
Transformer 11/0.433 KV , 1000 KVA
Disconnection and Removing the unserviceable/ burnt out Secondary LT Bushing units complete and replace the same with same size and capacity of bushing with brass Studs along with suitable nut bolt and washers complete suitable for the following Transformers :-
Transformer 11/0.433 KV , 50/63 KVA
Transformer 11/0.433 KV , 100 KVA
Transformer 11/0.433 KV , 160 KVA,
Transformer 11/0.433 KV , 200 KVA
Transformer 11/0.433 KV , 250 KVA
Transformer 11/0.433 KV , 315 KVA
Transformer 11/0.433 KV , 1000 KVA
M & L for Silica Gel of Transformer including removing the unserviceable Silica gel all as directed at site.
M&L for spreading of Crushed metal stone aggregate 40mm grade required thickness complete all as specified and as directed.
M & L for Mild steel plates, plain or chequered, 5mm thick cut to shape and size to match the existing HT / LT cable ducts including provision of holes to accomodate the handles and painting the same with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Supply and fix mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including bolts, nuts, washers inclusive of one coat primer and two coats of painting including dismantling the unserveable one complete all as specified and as directed. Make :- SAIL/ TISCO/ RINL/ Jindal Steel
Repairing and servicing (Oiling and greasing) of gang operated switch 11 KV vertical/Horizontal mounted and Including replacement of U/S spare parts like male,female blade brass, moving links with wire,connectors,sleeves as required for smooth functioning of switch, testing for its proper operation, complete all as specified and as directed. by Engr-in-Charge. Note : - complete GOD repairs is measured in one Job
Disconnecting & Removing the unserviceable GODO horizontal / vertical of capacity 400 A, 11 KV from the Two/four pole / six pole structure carefully and supply and fix gang operated air-break switch 400 A, 11 KV, triple pole, 12 insulator type mounted on post insulator along with 25mm light grade GI tubing operating from operating mechanism from ground level complete all as specified and as directed. Note : - Cost of Jumper connections along with fixing material deemed to inclusive in the unit rate. Make - Pactil, Mumbai/ Southern Switchgear, Jaipuria Brothers/BHEL
Description all as per Item No.34 here-in-above but of capacity 200 Amps complete all as specified and as directed
Disconnecting and removing the unserviceable 11 KV Disc type insulator from HT poles and S&F Disc type insulator, porcelain, vitreous 145mm hight and 255mm dia ball and socket type, white, brown or green single disc assembly of 11000 Volts ISI Marked along with fixing material such as GI bolt, nut and washers etc. complete all as specified and as directed. Make :- BHEL/ Jayshree/ WS Insulators.
Disconnecting and removing the unserviceable 11 KV Pin insulator from HT poles and S & F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 Volts ISI Marked along with fixing material such as GI bolt, nut and washers etc. complete all as specified and as directed. Make :- BHEL/ Jayshree/WS Insulators.
Disconnecting and removing the unserviceable 11 KV Lightening arrester carefully from the 2/4/6 Pole structure and Supply & fix lightining arrester suitable for 11000 Volts of discharge capacity 65 Kilo Amp, 3 Phase including connecting of the same to the supply with necessary fixing materials such as nut bolt, washers etc. complete all as specified and as directed at site by the Engineer-in-Charge. Make :- Oblum/BHEL/ GEC-ELPRO.
Disconnection and removing the unserviceable 11 KV Expulsion fuse single pole carefully from the 2/4/6 Pole structure and Supply & fixing Expulsion/drop out fuse unit along with post insulators suitable for 11000 Volts, 50 A capacity including connecting of the same to the supply with necessary fixing materials such as Aluminium jumpers, Aluminium binding wire etc. complete all as specified and as directed at site by the Engineer-in-Charge. Make :- Southern switchgear/ Crompton greaves/ Schenider
M&L for stringing and fixing in position of ACSR conductor in OH line connections as per site requirement including provision of aluminium binding wire complete all as specified. Make :- All-Ind / ICC / Bharat Conductors
Restringing of HT 3 lines of existing over head line of ACSR conductor after disconnecting from the insulators & jumpers to the required tension & sag & binding up & connecting to insulators & jumpers properly test complete, chopping off trees branches (coming in the way/line) all as directed. Note :- (a) Trimming of tree branches up to 1.5 RM from the conductor deemed to be inclusive in the unit rate (b) single conductor from both sides shall be considered for measurement
Dismantling ACSR conductor of any size complete all as directed.
Supply and fixing indicating lamp red,yellow,blue,green, white of operating voltage 24/110/230 volts including taking down unserviceable indicators complete all as specified and as directed. Make :- Wipro/ Bajaj / Havells / Crompton Greaves / Jyothi
M&L for topping up and replacement of old transformer oil with new transformer oil in the existing transformer 11/0.433 for topup or achieve the required level after centrifuging by the centrifuging machine complete all as specified and as directed Make :- Power Oil/ Transol/ GET
S&F PVC sleeves of 15 mm dia in RYB colour for protection of Jumper on HT/LT poles / structure complete all as specified and as directed.
Removing the unserviceable Danger notice plate and S&F danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm size complete all as specified and as directed.
M&L for filteration, centrifuging, dehydration and testing of transformer oil by using centrifuging/ filteration machine for installed transformer, 11/0.133 KV at various sub station in order to achieve the desired dielectric strength of transformer oil as per relevent IS-1981 complete all as specified and as directed
M&L for disconecting the transformer conections and taking down from its foundation , transporting to work shop/MES store yard or site , drain out the oil from chamber complete ,opening of transformer and lifting of core and winding cleaning of tank and core ,varnishing of winding for improvement of insulation resistance value reassembled the same and refilling of new/desired transformer oil reconection the same duly replacing cork sheet,worn out parts nut,bolt and washers and breather assembly on existing location or other location complete capacity of transformer 315/250/200/100/50 KVA complete all as specified and as directed.
M & L for preparation of old painted surfaces of HT/LT transformers of capacity 50 KVA to 100 KVA including removing oilly and greasy spots and applying one coats of synthetic enamel paint including white wash to transformer foundation plinth and lettering with white paint as MES NO/SM No, capacity, year of installation, serial No over coat on black paint complete all as specified and as directed.
Description all as per Item No 49 here-inbefore but transformer of capacity 163 to 250 KVA
Description all as per Item No 49 here-inbefore but transformer of capacity 315 to 750 KVA
Description all as per Item No 49 here-inbefore but transformer of capacity 1000 KVA
Removing the unserviceable silica gel container/breather and S& F Silica gel container (breather unit complete) suitable for existing transformers of capacity upto 1000 KVA complete all as specified and as directed.
Load balancing of transformers capacity 100 KVA to 750 KVA including changing of connections of cable/service connections, jumper connections on OH lines for one phase to another phase and testing complete all as directed. Note :- (i) Work shall be executed after written order of Engineer-in-Charge. (ii) Proper shut down shall be arranged by the Engineer-in-Charge. (iii) Load variation in Amperes shall not be more than 10 % between three phase.
Disconnecting & Removing the unserviceable oil filter from DG set and Supply & Fix new oil filter , cleaninng the complete oil chamber with suitable fuel duly cranking the engine to fine clean, fixing new oil filter element with rubber gasket and filling and toping up of engine oil for the folliwng capacity of DG sets complete all as specified and as directed Note : - Engine Oil Measured and Paid Seprately. Make :- MICO / Puralator / Bosch.
(a) DG set 25 to 40 KVA
(b) DG Set 62.5 & 82.5 KVA
(c) DG set 100 & 125 KVA
(d) DG set 160 & 200 KVA
(e) DG set 250 KVA
(f) DG set 320 KVA
(g) DG set 500 KVA
(h) DG set 1010 KVA
Disconnecting & Removing the unserviceable fan/alternator/dynamo belt from DG set & Supply & fixing new fan/alternator/dynamo belt of same size and capacity for the following DG sets complete all as specified and as directed :- Make :- Fenner / LUCAS / TVS
(a) DG set 25 to 40 KVA
(b) DG Set 62.5 & 82.5 KVA
(c) DG set 100 & 125 KVA
(d) DG set 160 & 200 KVA
(e) DG set 250 KVA
(f) DG set 320 KVA
(g) DG set 500 KVA
(h) DG set 1010 KVA
Disconnecting & Removing the unserviceable filter from DG set and Supply & Fix a set of new diesel filter, cleaninng filter cell, fixing filter element with rubber gasket for the folliwng capacity DG sets complete all as specified and as directed :- Make :- MICO / Puralator / Bosch.
(a) DG set 25 to 40 KVA
(b) DG Set 62.5 & 82.5 KVA
(c) DG set 100 & 125 KVA
(d) DG set 160 & 200 KVA
(e) DG set 250 KVA
(f) DG set 320 KVA
(g) DG set 500 KVA
(h) DG set 1010 KVA
Disconnection and removing the unserviceable fuel injection pump carefully from the 62.5 to 125 KVA DG Set and servicing the same including renewal of u/s parts such as fuel pump, fuel pipes, injector pipes, nozzles with complete accessories and carried out complete calibration and fixing back in its original position to replace spares to serviceable testing and commissioning complete all as specified and as directed.
Disconnection and removing the unserviceable fuel injection pump carefully from the 160 to 320 KVA DG Set and servicing the same including renewal ofu/s parts such as fuel pump, fuel pipes, injector pipes, nozzles with complete accessories and carried out complete calibration and fixing back in its original position testing and commissioning complete all as specified and as directed.
Disconnection and removing the unserviceable fuel injection pump carefully from the 500 to 1010 KVA DG Set and servicing the same including renewal of u/s parts and carried out calibration fixing back in its original position testing and commissioning complete all as specified and as directed.
Disconnection and removing the u/s self starter unit 24 volts capacity carefully from the 500 to 1010 KVA DG Set for finding out the defects and to replace the u/s items such as field coils, bentex, armature solenoid switch etc and refixing the same in its original postion after completion repairs including testing and commissioning complete all as specified and as directed. Make : - TVS Lucas/Fenner or as approved by the OEM. Note :- Armature and bentex will be measured and paid respectiveitem of the schedule.
Disconnection and removing the u/s self starter unit 24 volts capacity carefully from the 125 to 320 KVA DG Set for finding out the defects and to replace the u/s items such as field coils, bentex, armature solenoid switch etc and refixing the same in its original postion after completion repairs including testing and commissioning complete all as specified and as directed. Make : - TVS Lucas/Fenner or as approved by the OEM. Note :- Armature and bentex will be measured and paid respectiveitem of the schedule.
Disconnection and removing the u/s cells of 24 volts capacity battery carefully from the battery case of DG Set for finding out the defects and to replace the u/s items such as complete cells, terminals, sealed top case to serviceable the battery a min of period 2 years warranty and refixing the same in its original postion after completion repairs including testing and commissioning complete all as specified and as directed. Make : - as approved by the OEM.
Disconnection and removing the u/s self starter unit 12 volts capacity carefully from the 30 to 100 KVA DG Set for finding out the defects and to replace the u/s items such as field coils, bentex, armature etc and refixing the same in its original postion after completion of repairs including testing and commissioning complete all as specified and as directed. Make : - TVS Lucas/Fenner or as approved by the OEM. Note : - Armature and bentex will be measured and paid respectively item of the schedule.
Supply only bentex unit made with brass suitable for 12 volts self starter unit complete all as specified and as directed.
Supply only bentex unit made with brass suitable for 24 volts self starter unit complete all as specified and as directed.
Supply only Armature unit with copper winding suitable for 12 volts self starter unit complete all as specified and as directed.
Supply only Armature unit with copper winding suitable for 24 volts self starter unit complete all as specified and as directed.
Disconnection and removing the unserviceable self starter unit carefully from the 100 to 1010 KVA DG Set and S&F new self starter unit complete suitable for DG Set 100 to 1010 KVA including testing and commissioning complete all as specified and as directed. Make :- TVS Lucas / Fenner or equivalent approved make.
Supply and filling Engine oil 20 W-40 complete all as specified and as directed. Make :- Castrol GTX / Greaves Max Therm / Kirloskar / Power Oil / Electrol
Disconnection and removing the unserviceable power contactor 4 POLE carefully from Panel board and S&F new power contactor 4 POLE 100A 440 V comprising of all accessories type MCX-22 complete all as specified and as directed. Make :- L&T or its equivalent in Seimens / C&S / Havells.
Disconnection and removing the unserviceable power contactor 4 POLE carefully from Panel board and S&F new power contactor 4 POLE 125A 440 V comprising of all accessories type MCX-23 complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable power contactor 4 POLE carefully from Panel board and S&F new power contactor 4 POLE 200 A 440 V comprising of all accessories type MCX-33 complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable power contactor 4 POLE carefully from Panel board and S&F new power contactor 4 POLE 400 A 440 v comprising of all accessories type MCX-43 complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable Main contactor 3 POLE carefully from Panel board and S&F new power contactor 3 POLE 70 to 100 A comprising of all accessories type Hz MNX-70 complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable Main contactor 3 POLE carefully from Panel board and S&F new power contactor 3 POLE 80 to 100 A comprising of all accessories type MNX-80 complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable Main contactor 3 POLE carefully from Panel board and S&F new power contactor 3 POLE 95 to 160 A comprising of all accessories type MNX-95 complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable Main contactor 4 POLE carefully from Panel board and S&F new power contactor 4 POLE Model - LC1 FDP 2254A , AC3 :225A AC1:315A complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable Main contactor 4 POLE carefully from Panel board and S&F new power contactor 4 POLE 250 A Model -CTX150 4P complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable Main contactor 4 POLE carefully from Panel board and S&F new power contactor 4 POLE Model - LC1 FDP 400A , AC3 :400A AC1:500A complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the u/s Main contactor 4 POLE carefully from Panel board and S&F new power contactor 4 POLE Model - LC1 FDP 1504A , AC3 :150A AC1:250A complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare kit of Power contactor 4 pole, 415 volts and supply and fix new spare kit unit suitable for MCX-33 Power contactor complete all as specified and as directed. Make :- Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare kit of Power contactor 4 pole, 415 volts and supply and fix new spare kit unit suitable for MCX-43 Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare kit of Power contactor 3 pole, 415 volts and supply and fix new spare kit unit suitable for MNX-80 Power contactor of Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare kit of Power contactor 3 pole, 415 volts and supply and fix new spare kit unit suitable for Model - LC1 FDP 400A , AC3 :400A AC1:500A Power contactor of Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable speed governor unit carefully from DG Set and S&F new speed governor unit of same size and capacity suitable for 62.5 to 100 KVA complete all as specified and as directed. Make :- Kirloskar DG Set or its equivalent make CE .
Disconnection and removing the unserviceable speed governor unit carefully from DG Set and S&F new speed governor unitof same size and capacity suitable for 125 to 200 KVAcomplete all as specified and as directed. Make :- Kirloskar DG Set or its equivalent make CE.
Disconnection and removing the unserviceable speed governor unit carefully from DG Set and S&F new speed governor unitof same size and capacity suitable for 250 to 320 KVAcomplete all as specified and as directed. Make :- Kirloskar DG Set or its equivalent make CE.
Disconnection and removing the unserviceable power control unit and S&F new power control unit of same size and capacity suitable for existing Kirloskar make DG Set of capacity 62.5 to 100 KVA, Model KG934V1 or its equivalent complete all as specified and as directed.
Disconnection and removing the unserviceable power control unit and S&F new power control unit of same size and capacity suitable for existing Kirloskar make DG Set of capacity 125 to 200 KVA or its equivalent. Model KG545 Kirloskar V12 or its equivalent complete all as specified and as directed.
Disconnection and removing the unserviceable power control unit and S&F new power control unit of same size and capacity suitable for existing Kirloskar make DG Set of capacity 250 to 320 KVA or its equivalent. Model KG545 Kirloskar V12 or its equivalent complete all as specified and as directed.
Disconnection and removing the unserviceable engine control relay and S&F new engine control relay of same size and capacity suitable for existing Kirloskar make DG Set of capacity 62.5 to 125 KVA or its equivalent. Model E2CSPC Make : C&S or its equivalent. complete all as specified and as directed.
Disconnection and removing the unserviceable Advance digital controller and S&F new Advance digital controller relay of same size and capacity suitable for existing Kirloskar make DG Set of capacity 62.5 to 125 KVA or its equivalent. Model GADC-422 Make: GREAVES COOTON LTD or its equivalent.complete all as specified and as directed.
Taking down u/s automatic voltage regulator, supply and fixing a set of new automatic voltage regulator with UVN, PQ, F1F2 terminals rated voltage upto 67 Volts suitable for upto 320 KVA DG sets Make Kirloskar/Greaves complete all as specified and as directed.
Supply and topping up of coolent complete all as specified and as directed. Make :- Castrol / Veedol
Disconnection and removing the u/s HRC fuse unit set of links situated into the AMF Panel of DG Set carefully and S&F new HRC fuse unit complete all as specified and as directed. for the following capacity:-
(a) HRC Din type Fuse a set of link 630 Amps 500 Volts Make :- L&T type HN or its equivalent in Siemens / Havells
(b) HRC Fuse a set of link 315 to 400 Amps 500 Volts Make :- L&T type or its equivalent in Siemens/Havells
(c) HRC Fuse a set of link 200 Amps 500 Volts Make :- L&T type or its equivalent in Siemens/Havells
(d) HRC Fuse a set of link 100 to 125 Amps 500 Volts Make :- L&T type or its equivalent in Siemens/Havells
Disconnection and removing the unserviceable spare coil of Power contactor 4 pole, 415 volts and supply and fix new spare coil suitable for MCX-22 Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens / C&S / Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 4 pole, 415 volts and supply and fix new spare coil suitable for MCX-23 Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 4 pole, 415 volts and supply and fix new spare coil suitable for MCX-33 Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 4 pole, 415 volts and supply and fix new spare coil suitable for MCX-43 Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 3 pole, 415 volts and supply and fix new spare coil suitable for MNX-70 Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 3 pole, 415 volts and supply and fix new spare coil suitable for MNX-80 Power contactor of Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 3 pole, 415 volts and supply and fix new spare coil suitable for MNX-95 Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 3 pole, 415 volts and supply and fix new spare coil suitable for 4 POLE Model - LC1 FDP 2254A , AC3 :225A AC1:315A Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 3 pole, 415 volts and supply and fix new spare coil suitable for4 POLE 250 A Model -CTX150 4P Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 3 pole, 415 volts and supply and fix new spare coil suitable for4 POLE Model - LC1 FDP 400A , AC3 :400A AC1:500A Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Disconnection and removing the unserviceable spare coil of Power contactor 3 pole, 415 volts and supply and fix new spare coil suitable for 4 POLE Model - LC1 FDP 1504A , AC3 :150A AC1:250A Power contactor complete all as specified and as directed. Make :- L&T or its equivalent in Seimens/C&S/ Havells.
Material and labour for repairs of doors and acoustic enclosure with necessary hinges including welding soldering as required at site of upto 1010 KVA complete all as specified and as directed.
M&L for servicing of AMF panel upto 320 to 1010 KVA capacity of DG Sets including finding of all the defects and internal wiring and making functional of panel board complete all as specified and as directed.. Note: - Misc spare parts such as plug in relay, fuse cut out, under/over load relay, carbon tettra cholride required for cleaning of the contacts and consultant/ mechanic charges for visiting the site complete for satisfactory etc completion of the job deemed to be inclusive in the unit rate
Disconnection and removing the unserviceable Push button and S&F new push button (Existing type) with necessary mounting arrangement. complete all as specified and as directed.
Disconnection and removing the unserviceable relays and Supply and fixing Relays (Existing type 24/12 Volts) upto 320 KVA DG Sets AMF panels complete all as specified and as directed. Make::- L&T/ Siemens / C&S
Disconnection and removing the unserviceable relays and Supply and fixing Relays (Existing type12/12 Volts AC) up to 120 KVA DG sets AMF panels complete all as specified and as directed. Make :- L&T/ Siemens / C&S
Disconnection and removing the unserviceable auxilary contactors and Supply and fixing Auxilary Contactors (Existing type) with logic units complete all as specified and as directed. Make :- L&T / Siemens / C&S
Disconnection and removing the unserviceable under voltage and over voltage relay and Supply and fixing under voltage and over voltage relay siutable for existing AMF panel complete all as specified and as directed. Make : - Rishabh / MiniLec /C&S
Disconnection and removing the unserviceable Timer and Supply and fixing new Timer complete all as specified and as directed. Make : - L&T / CE
Disconnection and removing the unserviceable battery lead connection and M&L for battery connected two no leads made out of PVC Single core 50 Sqmm 1100 volts grade bunched copper conductor cable upto 1.5 m long including one end soldered with a copper lug and the other end soldered with a brass terminal along with nut, bolt and washer complete all as specified and as directed.
Disconnection and removing the unserviceable battery lead connection and M&L for battery connected two no leads made out of PVC Single core 50 Sqmm 1100 volts grade bunched copper conductor cable upto 1.0 m long including both end soldered with a brass terminal along with nut, bolt and washer for interconnection of batteries complete all as specified and as directed.
Disconnection and removing the unserviceable alternator of capacity of DG Set carefully from the engine and rewinding the same with single strand fine enamel copper conductor of same guage weight and tons and keeping the windings into hot air oven till the moisture evaporates and repair to slip ring assy in all respects and fixing the same init original position duly painted the alternator after completion of repairs connecting the cables and all the accessories testing and commissioning complete all as specified and as directed. of the following capacities:- Note :- (a) All the misc items such as Bearings, terminal, coupling, impregranted paper, warnising, cotton tape and other misc items required for satisfactory completion of job deemed to be included in the unit rate. (b) The above repairs are considered to meet the anticipated requirement if any and based on the site requirement the scope will be handed over to the Contractor.
(a) DG set 25 to 40 KVA capacity
(b) DG Set 62.5 to 82.5 KVA capacity
(c)DG set 100 & 125 KVA capacity
Disconnection and removing the unserviceable MCCB 4 pole, 415 volts and supply and fix new MCCB 4 Pole 250 Amps 25 KA Model DPX3 250 complete all as specified and as directed. Make :- Legrand or its equivalent in L&T/ABB
Disconnection and removing the unserviceable MCCB 4 pole, 415 volts and supply and fix new MCCB 4 Pole 250 Amps 36 KA Model DN2-250D complete all as specified and as directed. Make :- L&T or its equivalent in Legrand/ABB
M&L for Preparation of surfaces and painting the DG Set with accoustic enclosure and AMF Panel board with one coat of synthetic enamel paint of existing colour including marking of SM/MES numbering, capacity of the DG Set, date of installation etc complete all as specified and as directed. of the following capacities
(a)DG set 25 to 40 KVA capacity
(b)DG Set 62.5 to 125 KVA capacity
(c)DG set 160 to 320 KVA capacity
(d)DG set 500 to 1010 KVA capacity
Taking down radiators by unscrewing carefully nut bolts, and transporting to workshop for cleaning washing of blocked water cooling pipe and repair and soldeing/welding to arrest leakage in all respects, if any including necessery hard ware material like rubber bush and taking back to site. Fixing in the DG set for capacities of DG sets 25 KVA to 40 KVA complete all as specified and as directed Make :- Kirloskar
Taking down radiators by unscrewing carefully nut bolts, and transporting to workshop for cleaning washing of blocked water cooling pipe and repair and soldeing/welding if any including necessary hard ware material like rubber bush and taking back to site. Fixing in the DG set complete all as specified and as directed for capacities of DG sets 62.5 KVA to 125 KVA Make :- Kirloskar
Taking down radiators by unscrewing carefully nut bolts, and transporting to workshop for cleaning washing of blocked water cooling pipe and repair and soldeing/welding if any including necessery hard ware material like rubber bush and taking back to site. Fixing in the DG set complete all as specified and as directed for capacities of DG sets 160 KVA to 320 KVA Make :- Kirloskar / Greaves
Taking down radiators by unscrewing carefully nut bolts, and transporting to workshop for cleaning washing of blocked water cooling pipe and repair and soldeing/welding if any including necessery hard ware material like rubber bush and taking back to site. Fixing in the DG set complete all as specified and as directed for capacities of DG sets 500 KVA to 1010 KVA Make :- Kirloskar / Greaves
Disconnecting existing RPM meter and supply and fixing new RPM meter in the DG set as per existing make complete all as specified and as directed Make- Selec, Model - RC51000
Supply and fixing oil pressure guage as per existing sample & capacity including removing old oil pressure gauge complete all as specified and as directed (Make :- Yankey, Pricol,)
Supply & fixing temprature gauge oil/water in the DG set including taking down old temparature guage complete all as specified and as directed (Make :- Yankey , Pricol)
Taking down old fuel/Oil pipe line with benjo bolt supply and fixing new fuel/oil pipe lines (High pressure ruber pipe covered with stell armoured) complete all as specified and as directed
Supply and fill in the batteries of DG sets distilled water and acid mix water at different locations. complete all as specified and as directed
Supply and fixing battery terminal made up of brass including taking down unserviceable battery terminal. complete all as specified and as directed
Dismantling the fuel tank and fuel line / pipe complete clean ,replace the broken pipe lines and reconnect the fuel line and welding the tank to arrest leakage if any and refixing the fuel tank in same position complete all as specified and as directed
Supply and fixing coupling bush of engine to alternator including bolts including taking down damaged couplings complete all as specified and as directed
Supply and fixing injector set of fuel pipes and over flow pipe and including taking down unserviceable pipe complete all as specified and as directed
Taking down dynamo/alternator assembly from engine for repair/rewinding the motor and replacement of worn out parts complete in all respects and refixing the same including cheking of proper charging of batteries complete all as specified and as directed
Supply and fixing non return benjo bolt including taking down unserviceable benjo bolts complete all as specified and as directed
Supply and replace unserviceable fuel feed pump suitable for 62.5 to 125 KVA DG Set complete all as specified and as directed
Supply and replace unserviceable water body pump suitable for 160 to 320 KVA DG Set complete all as specified and as directed
Supply and replace unserviceable water body pump suitable for 62.5 to 125 KVA DG Set complete all as specified and as directed
Disconnection and removing the unserviceable PCB carefully from Panel board and S&F new PCB 12V DC W305 complete suitable for Make :- Kirloskar DG Set or its equivalent complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out /for laying under ground cables/pipes etc and getting out in soft / loose soil. complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 m in depth but not exceeding 3 mtr in hard / dense soil. complete all as specified and as directed.
Supply and laying unreinforced pre cast concrete cable cover class HV type 1 flat size 300 mm x 180 mm x 40 mm for cable protection complete all as specified and as directed.
Supply and spreading fine river sand in trenches for cushioning of under ground cable complete all as specified and as directed. Note :- Only punned thickness 18 cm will be measured and paid .
Returning filling in including spreading, levelling, watering and well ramming in layers n-exc 25 cms complete all as specified and as directed.
Removing excavated soil to a distance n-exc 50 mtr and depositing where directed at a level n-exc 1.5 mtr above the starting point complete all as specified and as directed.
Relaying old serviceable unreinforced pre cast concrete cable cover taken out from the trenches complete all as specified and as directed.
Taking down of HT XLPE/ PVC UG cable 11000 V grade ,3 core of any size/dia up to 240 Sqmm from the trenches along complete all as specified and as directed.
Relaying of old serviceable HT XLPE/ PVC UG cable 11000 V grade ,3 core of any size/dia up to 240 Sqmm from the trenches along complete all as specified and as directed.
M & L for XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor,3 core, 11000 volts, grade of the size 240 Sqmm complete all as specified and as directed.
Description all as per item no 150 here in above but of size 185 Sqmm
Description all as per item no 150 here in above but of size 120 Sqmm
Description all as per item no 150 here in above but of size 95 Sqmm
M & L for indoor type jointing kit heat shrinakable for 11KV grade UG cable end termination with 3 core Aliminium conductor complete along with jointing material all as specified and as directed of size 240 Sqmm Make:- Raychem / Densons / M-Seal / Birla-3M / CCI
Description all as per item no 154 here in above but of size 120 to 185 Sqmm
Description all as per item no 154 here in above but of size 95 Sqmm
M & L for outdoor type ,jointing kit,heat shrinakable for 11KV grade UG cable end termination with 3 core Aliminium conductor complete along with jointing material all as specified and as directed of size 240 Sqmm Make :- Raychem / Densons/ M-Seal/ Birla-3M/ CCI
Description all as per item no 157 here in above but of size 120 to185 Sqmm
Description all as per item no 157 here in above but of size 95 Sqmm
M & L for outdoor type Straight through ,jointing kit,heat shrinakable for 11KV grade UG cable with 3 core Aliminium conductor complete along with jointing material all as specified and as directed of of size 240 Sqmm Make: - Raychem / Densons/ M-Seal/ Birla-3M/ CCI
Description all as per item no 160 here in above but of size120 to 185 Sqmm
Description all as per item no 160 here in above but of size 95 Sqmm
Disconnection & Removing the unserviceable steel tubular poles and Supply & erect Steel tubular swaged poles 11.00 metres long ISI marked complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 complete all specified and as directed. Note:- Excavation, PCC, returning filling, pole painting and numbering will be measured and paid sepertely under relevant of items of Sch A.
M&L for Cement concrete in foundations, filling and mass concrete 1:3:6 Type C- 2 mix using 40 mm graded aggregate complete all specified and as directed.
M&L for Cement concrete in coping, filling and mass concrete 1:2:4 Type B-1 mix using 20 mm graded aggregate complete all specified and as directed.
Disconnection & Removing the unserviceable Aluminium conductor/jumper wires from the HT 4 Pole structure and M & L for New Aluminium overhead conductor jumpers sorrounded by PVC insulation sleeves with R,Y& B color code complete all as directed. Notes : (1) All the jumper wires should be replaced with New jumper wires (2) Type of conductor used for jumper shhould be RABBIT. (3) Cost deemed to be include for all the misc work such as Nut,bolts, washers, welding etc. for satisfactory completion of job . (4) Min clearance should be maintained among the conductors as per the Electricity Regulations. (5) Zero percent Sag should be maintained for each jumper wire to avoid short ckts.
Description all as per item No.166 above but for 3 Pole structures
Description all as per item No.166 above but for 2 Pole structures
M & L for painting to HT Steel tubular poles 11 mtr height by scapping the existing painting and repainting after due preparation of surface and applying a coat of primer i.e. red oxide complete with another coat of Aluminium paint complete all as specified and as directed .
M/L for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level ,Alternate layers of charcoal) & common salt Crystal and connected to copper earth strip20x3 mm by means of bolts, nuts, check nuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 5 of SSR Part I of 1991 & testing complete including 40mm dia light grade GI pipe upto 7.5mtr long, excavation in any type of strata, PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm with frame, test box , including 20 mm bore water pipe medium grade GI Tubing including GI Funnel , wire mesh etc. ( Note :- (a) Earth continuity conductor and GI protection pipe beyond 7.5m shall be measured and paid under the respective items ). (b) Qoted rate deemed to include the cost of excavation and earth work PCC Chamber, funnel cover etc.
Disconnection and removing the unserviceable earth conductor and S&F earth continuity conductor 25x4 mm galvanised iron strip buried in ground / fixed on pole / drawn in 40mm dia light grade GI pipe complete all as specified and as directed.
MAYUR ELECTRIC SERVICES
RAVINDRA BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .