Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST QUOTED | |
| 2 | L2₹40.1 L+₹7.9 L (24.6%)Rejected-Finance | L2 | Rejected-Finance L2 REJECTED |
Tender Value
₹33.5 L
EMD Value
₹50,000
Closing Date
5 Oct 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASSISTANT ENGINEER ,KARUNAGAPPALLY MUNICIPALITY
O/O THE ASSISTANT ENGINEER ,KARUNAGAPPALLY MUNICIPALITY
MUNICIPAL TOWER ELECTRIFICATION
2020_LSGD_387768_1
PW1/3738/17(B)
Open Tender
Electrical Works
Item Rate
180 days
karunagappally
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
Yes
online
₹50,000
Yes
3 Dec 2020
28 Sept 2020
9 Oct 2020
28 Sept 2020
5 Oct 2020
28 Sept 2020
180 days
Amount
Medium point rates: Supply and wiring points according to IS 732-1989 using rigid PVC ivory conduit of minimum size 20 mm conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade,including providing switch board main ,and continuous earthing with 1.5sqmm green coloured FR wire , required qty of copper earth socket, brass bolt and nut crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6 A modular typeROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. Single control light point with 6A, 3 plate ceiling rose
Single control light point without ceiling rose
Four Light point controlled by one switch with out ceiling rose
Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator.
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A switch in the same switch board as that of light points.
Independent plug
Call bell point with piano type 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end
Supply and providing 14 W CFL types and power rated lamps in the existing fittings as required
Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with shade and giving connection etc as required
Supply and installation of suitable size MS rod type fan clamp as per IS 732 as required.
Supply, conveyance, installation, testing and commissioning of ceiling fans of 1200mm sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.
Charges for cutting holes suitable for accommodating exhaust fans of sizes up to 305 mm sweep including plastering, colour washing etc. as required.
Supply, conveyance, installation, testing and commissioning of 305 mm sizes of exhaust fans in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.
Supply, conveyance, installation, testing and commissioning of pre-wired 18 W LED box light fittings and lamps . including supplying and fixing ball and socket arrangements on PVC round block, suspension down rod of 19mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connections etc. a required.
Supply, conveyance, installation, testing and commissioning of 80 Watts single piece LED light fittings suitable for roadway installation with pressure die-cast aluminium housing with corrosion resistance powder coating using Nano technology, natural cooling system,, Poly Carbonated UV treated diffuser for higher impact strength and optimum light trasmision, High efficient driver with short circuit, over voltage, over courent and thermal protection, Surge ptotection up to 5 KV, PF 0.95, IP 65 protection, Horizontal Pole Mounting type fittings with all connected accessories fixing on 'B" class GI pipe of 1 mts length, 25mm dia or suitable size bent to shap/ cut and welded to shape clamping the same on the existing pole using GI mounting clamps and giving connections with 1 sq. mm 3 core PVC insulated and PVC sheathed copper conductor fles wire etc. as required The LED fittings shall be guaranted for 3 years from the date of commissioning from any defects in manufactring. Any of the spares / components which are found to be defective during this period shall be replaced immediately at free of cost. (Make: Philips/ Crompton/ LT)
Supply, conveyance, installation, testing and commissioning of 200 Watts single piece LED Flood light fittings suitable for roadway installation with pressure die-cast aluminium housing with corrosion resistance powder coating using Nano technology, natural cooling system,, Poly Carbonated UV treated diffuser for higher impact strength and optimum light trasmision, High efficient driver with short circuit, over voltage, over courent and thermal protection, Surge ptotection up to 5 KV, PF 0.95, IP 65 protection, Horizontal Pole Mounting type fittings with all connected accessories fixing on the existing armand giving connections with 1.5 sq. mm 3 core PVC insulated and PVC sheathed copper conductor fles wire etc. as required The LED fittings shall be guaranted for3 years from the date of commissioning from any defects in manufactring. Any of the spares / components which are found to be defective during this period shall be replaced immediately at free of cost. (Make: Philips/ Crompton/ havells)
Supply, Conveyance, installation, testing and commissioning of recess mounting 18 W LED down light fittings of all types directly in the existing opening on the false - ceiling including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring etc as required ( Crompton)
Supply, Conveyance, installation, testing and commissioning of Surface mounting 18 W LED down light fittings of all types directly i on roof or wall including giving connections with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring etc as required
Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wire conforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall / ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required.
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required FP enclosure for independent mounting of MCB/ RCCB/ RCBO ( 1Nos ups & 2 No AC)
8 way single phase double cover (IP 42/43)
16 way single phase double cover (IP 42/43) ( UPS)
10 way single phase double cover (IP 42/43)
4 way (8+12) - three phase double cover (IP 42/43) ( 2nd & TF)
6 way (8+18) - three phase double cover (IP 42/43) ( GF & FF)
4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) ( FF. 2ed , GF& Lift )
6 way (8+18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) ( Third F AC)
Supply and installation of the following accessories suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required: 40 A double pole mini break isolator ( Shope & ups)
40 A 4 pole pole mini break isolator
63 A four pole mini break isolator
40 A, 2 pole, 30 mA RCCB (shope)
40 A, 4 pole, 30 mA RCCB
40 A, 4 pole, 300 mA RCCB ( Lift)
40 A, 10 kA, TP MCB (C curve)
6 A to 32 A, 10 kA, SP MCB (Ccurve)
Dammi plate
100 A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL (Third F AC)
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required : 3 module metal box in recess
9 module metal box in recess
1 /2 module metal box in recess (Rj 45& RJ 11)
6 module metal box in recess
Supply & Fixing the following types/ sizes of front plates on the existing modular boxes. : 1 / 2 module white/ off-white
3 module white/ off-white
6 module white/ off-white
9 module white/ off-white
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required : 6 A SP 1 way switch
6 A Universal socket
16 A SP 1 way switch
6 A/16a Universal socket (pp)
TV socket
Supply and fixing the following sizes of PVC Conduit conforming to IS 9537 / 1983 part III along with all required accessories on surface including making good the damages etc as required. 20 mm dia medium gauge
25 mm dia medium gauge
32 mm dia medium gauge
Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required. 100 x 50 mm CMS with base & lid
Cable divider
End Cap
Joint cover
External Angle 90°
Flat Angle 90°
Internal Angle 90°
Supply and drawing 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes. 1.50 sq mm 3 run
1.50 sq mm 6 run
2.50 sq mm 3 run (PP)
4.00 sq mm 2 run + 2.5 sq.mm 1 run ( 2AC Brith & 4 Nos UPS DB))
6.00 sqmm 4run + 2.5 sq. Mm 2 R ( 6 Nos L - DB)
10.00 sq mm 4 run ( UPS in )
Supplying & Drawing Cat 6 types of UTP Cable conforming to relevant standards through the existing conduit and giving connections as required
Supplying & Drawing the following types of T.V Co-axial Cable conforming to relevant standards through the existing conduit
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 2 core 10 sq mm with factory made clamp ( 10 Nos Shop)
4 core 10 sq mm with factory made clamp ( mccb v db to 2 nos a c Hall )
4 core 16 sq mm with factory made clamp ( 3 Nos V DB & Lift)
3.5 core 50 sq mm with factory made clamp ( Gr )
3.5 core 70 sq mm with factory made clamp ( MSB to metering )
3.5 core 35 sq mm with factory made clamp ( 3 ed F MCCB V DB)
3.5 core 125 sq mm with factory made clamp ( Fire Panel)
3.5 core 185 sq mm with factory made clamp ( MSB to Tr)
Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of 3.5 core 185 sq. Mm sizes in the existing masonry open duct as required.
Supplying siemens / tropodur type nickel plated compression brass cable gland for PVC insulated and PVC sheathed armoured aluminium/ copper conductor cable 1.1 KV grade, and making end termination suitable for 2/ 3/ 3½/ 4 core cable of the following sizes as required. 10 sq mm
Supplying and providing earth clamps for siemens/ tropodur type cable glands of suitable length and other dimensions noted along with each size of glands for the following sizes of cables as required. 4sqmm-16 sq mm with 12 mm wide x 1 mm thick clip
25 sq - 95sq mm with 20 mm wide x 1.20 mm thick clip
25 x 3 mm for earthing glands of size 240 sq mm to 300 sq mm
Supply of superior quality aluminium tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. 10 sq mm socket
16 sq mm socket
35 sq mm socket
50 sq mm socket
70 sq mm socket
120 sq mm socket
185 sq mm socket
Supplying, laying and jointing of 63/50 mm sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in ordinary soil)
300 x 300 x 6 mm cast iron gully trap with covering
2 x 25 x 3 mm tinned copper strip
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 2.00 mm copper conductor (14 SWG)
2.65 mm copper conductor (12 SWG)
3.15 mm copper conductor (10 SWG)
4.00 mm copper conductor (8 SWG)
6.00 mm copper conductor (4 SWG)
25 x 3 mm copper strip tinned at the points of contacts
25 x 3 mm GI strip
Supply and laying bare earthing conductors of 8 SWG sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).
supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc. as required. 2.00 mm (14 SWG)
2.65 mm (12 SWG)
3.15 mm (10 SWG)
4.00 mm (8 SWG)
6.00 mm (4 SWG)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 25 x 3 mm brass bolt & nut
25 x 6 mm brass bolt & nut
25 x 6 mm GI bolt & nut
25 x 8 mm GI bolt & nut
Supplying , threading , laying and jointing of 40 mm sizes of 'B' class GI pipe with all required accessories in ground in the existing trench as protective covering to earth leads.
MAIN PANEL BOARD: Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.60 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiring
Supply and providing 3mm thick size of SMC sheets in the panel as barriers & shrouding using required bolts and nuts including cutting to shape etc., as required.
Supply and fixing ' A " section types of beeding along the periphery of doors/ other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue
Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc. as required.
Fabrication, supply & fixing main bus bar system and interconnections with electrolytic grade Aluminium strips/ rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, copper sockets for round conductors, etc., as required.
Fabrication, supply & fixing earth bus system with copper strip/ conductor and connecting all accessories as per rule including g tinning the points of contacts etc as required
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required: 250 A, 36 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
120 A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
200 A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
Rotary drive kit (including BUC handle with door inter lock defeat & pad lock facility for MCCB of rating up to 160 A
Spreader/ terminal adapter kit Extended terminal for 4 pole MCCB of rating up to 250 A (8 Pcs)
Three phase multifunction meters to read V, A and F, accuracy class 1
LED indicators for all voltage ranges - Blue Colour
LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour
Aluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
20 A fuse holder for BS type blade fuses.
2 A-16A clip-on offset tag fuse link of size f1
Aluminium anodised legend plate of size 100 x 40 mm. with inscription of BUS BAR CHAMBER .
Aluminium anodised legend plate of size 100 x 40 mm. with inscription of CABLE ALLEY.
Aluminium anodised legend plate of size 40 x 20 mm. with inscription of EARTH.
Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.50 sq mm single run with required sockets.
Metering panel Board No.1: Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 using 1.60 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, s, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiring The panel board should also comprise the provision for incorporating 3 nos of three phase energy meters, 7 nos single phase energy meters with its cut-out and neutral links with vision panel meter reading.
Supply and providing 3mm thick size of SMC sheets in the panel as barriers & shrouding using required bolts and nuts including cutting to shape etc., as required.
Supply and fixing ' A " section types of beeding along the periphery of doors/ other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue
Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc. as required.
Fabrication, supply & fixing main bus bar system and interconnections with electrolytic grade Aluminium strips/ rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, copper sockets for round conductors, etc., as required.
Fabrication, supply & fixing earth bus system with copper strip/ conductor and connecting all accessories as per rule including g tinning the points of contacts etc as required
S & F switch disconnector unit (isolator) complete with handle assembly, door inter lock and padlocking arrangement of 120 A TPN ratings:
Supply and providing 40 A, 10 kA, DP MCB (Ccurve) in metering panel.
Rotary drive kit (including BUC handle with door inter lock defeat & pad lock facility for SDF of rating up to 160 A
Aluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
20 A fuse holder for BS type blade fuses.
2 A-16A clip-on offset tag fuse link
32 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
Aluminium anodised legend plate of size 100 x 40 mm. with inscription of BUS BAR CHAMBER .
Aluminium anodised legend plate of size 100 x 40 mm. with inscription of CABLE ALLEY.
Aluminium anodised legend plate of size 40 x 20 mm. with inscription of EARTH.
Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.50 sq mm single run with required sockets.
SSB- 1: Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.60 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiring
Supply and providing 3mm thick size of SMC sheets in the panel as barriers & shrouding using required bolts and nuts including cutting to shape etc., as required.
Supply and fixing ' A " section types of beeding along the periphery of doors/ other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue
Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc. as required.
Fabrication, supply & fixing main bus bar system and interconnections with electrolytic grade Aluminium strips/ rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, copper sockets for round conductors, etc., as required.
Fabrication, supply & fixing earth bus system with copper strip/ conductor and connecting all accessories as per rule including g tinning the points of contacts etc as required
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required 200A, 4 Pole, ON LOAD Change Over switch ( In comer)
S & F switch disconnector unit (isolator) complete with handle assembly, door inter lock and padlocking arrangement of 120 A TPN ratings: ( Fire)
120A, 25 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
LED indicators for all voltage ranges - Blue Colour
LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour
Aluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.
20 A fuse holder for BS type blade fuses.
2 A-16A clip-on offset tag fuse link of size f1
Aluminium anodised legend plate of size 100 x 40 mm. with inscription of BUS BAR CHAMBER .
Aluminium anodised legend plate of size 100 x 40 mm. with inscription of CABLE ALLEY.
Aluminium anodised legend plate of size 40 x 20 mm. with inscription of EARTH.
Carrying out control wiring for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 1.50 sq mm single run with required sockets.
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.60 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiring
Supply and providing 3mm thick size of SMC sheets in the panel as barriers & shrouding using required bolts and nuts including cutting to shape etc., as required.
Supply and fixing ' A " section types of beeding along the periphery of doors/ other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue
Fabrication, supply, conveyance and installation of base frame for floor mounting type panel board using channel of class designation ISMC 75 including cutting, welding, drilling holes, painting with two coats of synthetic enamel paint over a coat of zinc chromate primer, bolting the frame to the panel and to the finished floor using required bolt and nuts, making good the damages etc. as required.
Fabrication, supply & fixing main bus bar system and interconnections with electrolytic grade Aluminium strips/ rigid conductors conforming to IS 1867 (with latest amendments) for bus bar arrangement with single strip per phase supported on finger type bus bar supports of adequate size, spacing between supports not exceeding 50 cm & overhang not exceeding 5 cm including bending to shape, drilling holes, tinning the points of contacts, fixing heat shrinkable PVC sleeves, plated bolts and nuts with plate washers and spring washers, copper sockets for round conductors, etc., as required.
Fabrication, supply & fixing earth bus system with copper strip/ conductor and connecting all accessories as per rule including g tinning the points of contacts etc as required
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required 200A, 4 Pole, TPN FS HRC
200 A HRC Fuse base
160 A HRC fuse link
200 A Neutral Link
NET WORKING: Supply and fixing 24 port 10/100/1000 Gigabit switch and giving connection
Supply, installation, testing and commissioning of 24 port patch panel with shulter including termination etc as required.
Supply, installation, testing and commissioning of 9U rack having cable manager, Power supply, hardware, necessary supports etc. including termination etc as required.
Supply and providing power supply unit for giving connection to the Rack
Supply and installation of 1 meter patch cord
Supply and installation of 2 meter patch cord
CCTV : Supply and fixing 20 pair factory made Krone connectors in a metalic enclosure fixed on the wall and giving connection etc: as required.
Supply, Conveyance, Installation , Testing and Commissioning of 2 MP High Quality HQIC Pro Image Sensor. 6 mm lens. minimum illumination 0.ll-ux@(F1.2, AGC ON)0 lux with IR,BNC output,IR Range of 30 m or above , true day/ night, IP66 weather proof, AGC, AWB and BLC, CE" FCC and RoHS Cerrified, working on 12V DC supply and with all necessary mounting brackets and connecting pins and with 2 years warranty.
Supply. Installation, Testing and commissioning of 16 channel HD DVR with H264 video compression 1080P/VGA/WD1/4CIF/CIFrecording resolution, support 2 SATA HDD up to 8 TB (2x4 TB), USB2.0, RJ45 Ethernet . 8 channel BNC input, HDMI & VGA Video Output and with 2 years warranty.
Supply, Installation, Testing and Commissioning of 32" LED TV with wall Mount bracket and all accessories including necessary connecting cables
Supply and installation of 4TB SATA 3Gb/s HDD for video recording inside the existing 24x7 reliability, reduced power consumption, Compatible and minimum three Year Warranty
Supplying & Drawing 3+1 (RG59+0.,5X3 copper) Co-axial Cable conforming to relevant standards through the existing conduit and giving connection to the surveillance cameras
Supply and installation of DC Power supply for the cameras, AC input range of 180- :10V. DC output of 12V l0A and with Three Years warranty.
Supply and installation of 6U Rack with necessary trays including cooling fan, power strip and with all necessary accessories
Supply & commissioning of l KVA 168 vAH Digital UPS with minimum one hour back up time
EPABX Supply, installation & commissioning of Digital EPABX having expansion slot for minimum 24 extensions and initially equipped with 24 extension circuits,3 Trunk lines, necessary MDF & KRONE connectors,Lighting protector ,Spike Protector for trunk lines . Preferred make: Panasonic KX-NS300
Supply, installation & commissioning of DTMF telephone with glass epoxy coated printed board. Preferred model: Panasonic TS 500 or equivalent.
Supply, installation & commissioning of DTMF CLI telephone with glass epoxy coated printed board. Preferred model: Panasonic KX-TSC62SX or equivalent.
Supply & fixing of RJ11 Telephone Jack
Supplying & Drawing un armoured PVC insulated and & PVC sheathed copper conductor 2 pair Telephone Cable conforming to ITD specification for indoor application through the existing conduit Preferred make: Finolex/Deltron/Traco.
PA SYSTEM: Central Distribution amplifier. Supply of central distribution amplifier of the following size a) Digital recorder b) Play bak prerecorder massages c) 3 mic. Input and one aux input d) Send/ return facility e) Head phone out put provided f) Automatic mic. Off switch provided
Chairman Control Unit a) Highly sensitive condenser microphone b) 47 cm. goosneck + expansition c) Ring led d) Built - in speaker and volume control e) Head phone out put provided f) Priority mute delegate g) Chime tone attention h) Priority and talk switch
Delegate Unit a) Highly sensitive condenser microphoneb) 47 cm. goosneck + expansitionc) Ring led d) Built - in speaker and volume control e) Head phone out put provided f) Indicate the out put signal level g) Talk switch
Power boosting unit
Confrence cable through conduit
Extra speaker system for sound boostinga) Amplifier 160 w
b) Compact 8 W ceiling PA speaker system.
c) Wireless microphone duit UHF
Speaker Cabling through conduit
Chagres for Conveyance, installation, testing and commissioning of whole unit
Supplying and installation including all manner of supports/ suspenders, anchor bolts etc for cable trays made out of suitable size channel sections, slotted angles, flats, MS plates etc as required including painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.
Supply and providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 11 KV dielectric strength.
Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required
K.Gopalakrishnan
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_551001.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .