Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹168.3 CrAdmitted-Finance 4A SWAIKA CENTRE POLLOCK STREET DALHOUSIE KOLKATA WEST BENGAL 700001 | KOLKATA | WEST BENGAL | 700001 | ₹168.3 Cr | Admitted-Finance |
| 2 | ₹175.9 CrAdmitted-Finance 1ST FLOOR POLYCAB HOUSE 771 PANDIT SATWALEKAR MARG MAHIM WEST MUMBAI MAHARASHTRA 400016 | MUMBAI | MAHARASHTRA | 400016 | ₹175.9 Cr | Admitted-Finance |
| 3 | ₹183.3 CrAdmitted-Finance | ₹183.3 Cr | Admitted-Finance |
| 4 | ₹183.6 CrAdmitted-Finance | ₹183.6 Cr | Admitted-Finance |
| 5 | ₹184.5 CrAdmitted-Finance | ₹184.5 Cr | Admitted-Finance |
| Sl No | Description | Qty | Unit | LASER POWER & INFRA PRIVATE LIMITED | VAISHNO ASSOCIATES VIDYUT PROJECTS LLP | Lumino Industries Limited | J K Electric Contractor LLP | Cabcon India Limited | India Commercial Services | Polycab India limited |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00PCC Poles | ||||||||||
| 2.00 | PCC Pole 9 mtrs long (400 KG) | 1,319 | NOS | 71,68,247.95 ₹71.7 L | 6,38,13,220 ₹6.4 Cr | 53,85,991.41 ₹53.9 L | 65,36,964 ₹65.4 L | 92,55,562.81 ₹92.6 L | 65,75,329.75 ₹65.8 L | 62,39,750.04 ₹62.4 L |
| 3.00 | PCC Pole 9 mtrs long (200 KG) | 57,567 | NOS | 21,40,58,053.87 ₹21.4 Cr | 18,34,08,462 ₹18.3 Cr | 18,16,78,308.84 ₹18.2 Cr | 22,08,37,374.06 ₹22.1 Cr | 24,78,80,612.14 ₹24.8 Cr | 22,36,72,733.02 ₹22.4 Cr | 19,62,38,223.56 ₹19.6 Cr |
| 4.00 | Outdoor 11 KV O/D VCB KIOSK complete with accessories including use of special tools | 151 | NOS | 7,78,51,474.68 ₹7.8 Cr | 6,23,63,000 ₹6.2 Cr | 5,96,98,535.48 ₹6.0 Cr | 6,43,22,980 ₹6.4 Cr | 7,12,81,060.45 ₹7.1 Cr | 6,19,91,052.81 ₹6.2 Cr | 5,97,09,618.28 ₹6.0 Cr |
| 5.00 | Armoured Cable of size 2C X 4 SQ.MM. 1100 Volts PVC Insulated | 4.53 | KM | 2,97,195.9 ₹3.0 L | 4,54,359 ₹4.5 L | 2,54,071.89 ₹2.5 L | 4,00,905 ₹4.0 L | 3,53,090.72 ₹3.5 L | 2,62,355.02 ₹2.6 L | 8,16,857.83 ₹8.2 L |
| 6.00 | Control Cable of size 12C X 2.5 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules | 1.51 | KM | 6,04,493.86 ₹6.0 L | 4,81,086 ₹4.8 L | 5,56,145.22 ₹5.6 L | 6,77,084 ₹6.8 L | 6,62,995.38 ₹6.6 L | 7,35,036.77 ₹7.4 L | 7,34,163.59 ₹7.3 L |
| 7.00 | Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing | 19.63 | KM | 21,93,788.01 ₹21.9 L | 25,47,974 ₹25.5 L | 37,13,126.38 ₹37.1 L | 28,02,771.4 ₹28.0 L | 28,17,528.34 ₹28.2 L | 33,09,879.37 ₹33.1 L | 24,58,137.07 ₹24.6 L |
| 8.00 | Overhead steel cored aluminum ACSR Rabbit conductor in all respect | 7,998.06 | KM | 43,65,94,447.37 ₹43.7 Cr | 53,32,30,660.2 ₹53.3 Cr | 76,50,78,784.99 ₹76.5 Cr | 56,62,62,648 ₹56.6 Cr | 58,35,54,232.97 ₹58.4 Cr | 57,46,12,096.37 ₹57.5 Cr | 51,25,68,491.19 ₹51.3 Cr |
| 9.00 | Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length with GI wire and clamp as per latest specification and drawing adopted & approved by NIGAM. | 12,056 | SET | 1,16,42,481.61 ₹1.2 Cr | 1,42,26,080 ₹1.4 Cr | 1,17,00,524.02 ₹1.2 Cr | 1,28,03,472 ₹1.3 Cr | 1,32,75,066.55 ₹1.3 Cr | 1,34,34,114.13 ₹1.3 Cr | 1,62,72,643.87 ₹1.6 Cr |
| 10.00 | MS earthing rod 20mm dia, 3 meter long for substation earthing | 906 | Nos | 7,34,671.78 ₹7.3 L | 10,69,080 ₹10.7 L | 7,13,290.18 ₹7.1 L | 9,62,172 ₹9.6 L | 8,59,711.37 ₹8.6 L | 10,09,564.32 ₹10.1 L | 37,43,511.91 ₹37.4 L |
Tender Value
₹189.2 Cr
EMD Value
₹3.8 Cr
Closing Date
3 Jul 2025, 5:00 pmClosed
SE(RDSS)
SE(RDSS), JVVNL, Jaipur, Old Power House, near Ram mandir , Banipark
Segregation of 11 KV mixed feeders at Bhiwadi circle of Jaipur Discom of Rajasthan State under Revamped Reforms-Based and Results linked Distribution Sector Scheme (RDSS) on turnkey basis against TN-594.
2025_JVVNL_476145_1
JVVNL/INFRA/FS/BWD/TN-594
Open Tender
Electrical Works
Bhiwadi
Please refer Tender documents.
3 documents required · 3 mandatory
₹29,500
Jaipur Vidyut Vitran Nigam Limited
₹3.8 Cr
jaipur
23 Sept 2025
5 Jun 2025
7 Jul 2025
5 Jun 2025
3 Jul 2025
13 Jun 2025
5 Jun 2025 - 9 Jun 2025
10 Jun 2025
PCC Poles
PCC Pole 9 mtrs long (400 KG)
PCC Pole 9 mtrs long (200 KG)
Outdoor 11 KV O/D VCB KIOSK complete with accessories including use of special tools
Armoured Cable of size 2C X 4 SQ.MM. 1100 Volts PVC Insulated
Control Cable of size 12C X 2.5 SQ.MM. 1100 Volts PVC Insulated including supply of ferrules
Overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing
Overhead steel cored aluminum ACSR Rabbit conductor in all respect
Earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length with GI wire and clamp as per latest specification and drawing adopted & approved by NIGAM.
MS earthing rod 20mm dia, 3 meter long for substation earthing
CTPT structure Set (Galvanized)
11KV CT PT Set(200/5 Amp.)
MIP meter box for meter with TTB
GI Nut & Bolt assorted Size
GO double break without EB & with PI Isolator on existing bracket complete in all respect as required including hardware, nut, bolts & washer etc.
11KV ( with 9 x 24 KV Post Insulator ) 400 Amp.
Horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc.
11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS
Supply of Insulators
11KV Porcelain Disc.insulators B&S type 45KN
Hardware for 11KV disc insulator B&S type 45KN
Composite Polymer insulators
11KV Polymer Disc.insulators T&C type 45KN
Hardware for 11KV disc insulator T&C type 45KN
11 KV composite polymer Pin Insulator complete in all respect
PG clamps for suitable ACSR DOG Conductor
PG clamps for suitable ACSR Rabbit Conductor
11 KV Danger plate of size 200 X 250 mm complete in all respect
Supply of Angle and Channel
M.S Channel 100x50x6 mm
M.S Channel 75x40x6 mm
M.S Angle 65x65x6 mm
M.S. Flat 50 X 6 mm (Galvanized)
1.4 Mtr Channel bracket with clamp
Supply of Lightening arrestors
Substation type 9KV, 10KA station class (1Set=3 Nos.) lightening arrestors.
11kV Double pole line structure set for cut point complete on existing poles in all respect with clamp, as required made from M.S.Channel 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.Angle 65 X 65 X 6 MM, M.S.Angle 50 X 50 X 6 MM AND M.S.Flat 50 X 6 MM (Galvanized as per IS)
GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps,
Strain/Guy insulator for stay set
7/10 SWG GI Stay Wire
GI Wire 8SWG
UNDERGROUND CABLE FOR WORKING VOLTAGE OF 11KV ALUMINIUM CONDUCTOR (IS 7098) CABLE XLPE ARMOURED
Under ground Cable of Size 3X185 SQ.MM for 11 KV
G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK)
GI PIPE for Cable Support at Pole ( Each 3.3 Mtr )
CABLE JOINTING KIT FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
XLPE 3X185 SQ.MM H.S.S.T. JOINT
11.4 MTR. Long lattice tower with cross arm made of 50 X 50 X 6 MM M.S. angle with 50 X 6 MM M.S. FLAT for bracing as per nigam specification
11KV Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized)
Supply of 11/0.4 KV SubStation structure set for Three Phase 25 KVA transformer on double poles in all respect. weight(As per Specification and Drawing without GO channel) of Approx=166.67 kg (All galvanized as per relevant IS)
Supply of 11/0.4 KV SubStation structure set for Three Phase 63 KVA transformer on double poles in all respect. Weight (As per Specification and Drawing with GO channel) Approx=219.54 kg (All galvanized as per relevant IS)
11 /0.4 KV Al wound, Three Phase Distribution Transformer
25 KVA (Completely self protected with provision of LT Bushing Box)
6.35/0.24KV S/S structure set for single phase transformer on single 9Mtr, 400KG PCC pole in all respects.
11KV 100 Amp drop out cum isolator with 3.0 Amp. Fuse & 12 KV Post insulators.
LT XLPE Cable
Size 4CX70 SQ. mm
Size 4CX120 SQ. mm
Aerial Bunched Cable
Aerial Bunched Cable 1Cx25+1x25 Sqmm
Aerial Bunched Cable 3Cx25+1x25 Sqmm
Aerial Bunched Cable 3Cx50+1x35 Sqmm
LT Distribution pillar Box 200A
Dead end (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS)
Suspension (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS)
LT insulation piercing connectors NFC Type A (main to tap) (main 16-50 mm2, Tap off 2.5-16 mm2)
LT insulation piercing connectors NFC type B ( main to main) (size 16-50 mm2)
LT Bracket with clamp 600mm (2Ft)
LT Shackle Insulator with hardware
Description of Work / Item(s)
11 KV Bay
Grass cutting and surface dressing including removal of unwanted/rubbish plants with roots from open ground /yard and other Nigam premises with stacking of grass/plants at desired place near the ground.
Levelling of ground up to 30 cm.depth. with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder.(Including all lead & lifting)
erection of outdoor 11 KV O/D VCB KIOSK complete with accessories including use of special tools & conducting all pre commissioning tests before energisation, filling oil etc. complete in all respect with erection& grouting of structure (excluding civil works).
Laying, Testing Termination of armoured Cable of size 2C X 4 SQ.MM. 1100 Volts PVC Insulated for VCB supply to design various cores of armoured cables by terminal no. of identification including utilisation of cable gland.
Laying, Testing Termination of control Cable of size 12C X 2.5 SQ.MM. 1100 Volts PVC Insulated including installation of ferrules to design various cores of control cables by terminal no. of identification including utilisation of cable gland.
Drawing of overhead steel cored aluminum ACSR DOG[100SqMM(6+7) /(4.72+1.57)] conductor complete in all respect as per latest specification and drawing
laying of M.S. Flat 50 X 6 mm (Galvanized) for earthing
Erection of earthing rod sets for S/S made with MS Rod (Galvanized ) 20 mm dia, 3 meter length
Installation of metering points on 11 KV outgoing feeder at 33/11 KV S/S.The installation work to be carried out as per drawing/design,under the supervision of concern Assistant Engineer (including erection cost of (a), (b), (c), (f), (g))
(a) Mounting structure (Galvanized)
(b) The requisite steel members shall joint/weld the members to form the mounting structure as per drawing.Necessary tools,welding ,machines,lifting devics etc. shall be arranged by contractor.
Civil works
(c) Erection of lattices in alignment including excavation and concreting of structure foundation including cement, sand and grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40 mm size for ratio 1:5:10 and curing for period as required (21 days). Area of concreting will be as per the drawing.
Installation of Metering equipments:
(d) Installation 11KV CT PT Set(200/5 Amp.)
(e) Installation MIP meter boxThe meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block(TTB) link type shall be provided by contractor in the meter box.
(f) The required cables from CTPT set to meter box laid down in 50 mm GI pipe with suitable bends & nipples, shall be provided by contractor alongwith the consumable items such as PVC tapes, petroleum jelly etc. The cable should be PVC multi strand copper 12 core 2.5 Sq. mm ISI marked and firm & tight connections shall be made by suitable connector e.g. at CTPT sets by using clamps and at meter/TTB by suitable lugs etc. The CTPT sets so installed shall be earthed by means of the MS Flat (size 50x6 mm) by joining it with the nearest earthing available at the sub-station. Requisite earthing material shall be made available by the contractor.
(g) Commissioning of Metering Equipments:Installed meters inside the box and metering equipments duly mounted on the mounting structure will be powered up by connecting load in the presence of the concerned Assistant Engineer who will arrange the necessary shut down. The completion certificate shall be furnised by contractor.be filled accordingly. Since the work involves higher A.C. voltage level, the contractor shall take full care regarding safety norms, so as to avoid any accidental hazards.
Fixing of GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc.
11KV ( with 9 x 24 KV Post Insulator ) 400 Amp.
Fixing of horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc.
11KV ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs and 1.2x0.6x1.35 cum for 8 mtrs PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
PCC Pole 9 mtrs long (200 KG)
In Hard soil
Constn. of 11 KV VCB Kiosk Plate form 3.0 x 1.5 x 1.5 Mtrs. Including excavation in all type of soil up to the depth of 900 mm, foundation concrete in C.C. - 1 : 5 :10 for 150 mm thickness, brick masonary in cement mortar of mix. 1:8 with top of the plate form finished with 100 mm layer of C.C. 1:2:4 including fixing of foundation bolts and cement plaster - 20 mm thick of mix ratio 1:6, on all the exposed surfaces of the plate form - complete in all respect. (including supply of material for 6.75 CUM/VCB)
Fixing of 45KN. porcelain Disc.insulators for 11 KV ( each unit consisting of 2Nos disc insulators & one B&S Type hardware) on brackets complete including all acessories like hardware fitting etc.
Fixing of 11 KV composite polymer Pin Insulator complete in all respect
Fixing of PG clamps Dog to Dog on over headlines/jumpers, etc. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanising
Fixing of 11 kV Danger plate of size 200 X 250 mm complete in all respect
Erection of 11KV Bay channel
Erection of Bay channel size of 75x40x6 (6nos of 3750mm (total size 22.5mtr = 6 x 3.75mtr) & 2 nos of 3400mm (total size 6.8mtr = 2 x 3.4mtr) & 100x50x6 (6 nos of 3750mm (total size 22.5mtr = 6 x 3.75mtr) Approx weight 424.30Kgs ((22.5 mtr + 6.8Mtr) x 7.14Kgs per mtr = 209.20Kgs) + (22.5mtr x 9.56Kgs per mtr = 215.1Kgs)
Erection of petty items works using following steel items
Erection of M.S Channel 100x50x6mm
Erection of M.S Channel 75x40x6mm
Erection of M.S Angle 65x65x6mm
Installation of Substation type 9KV, 10KA station class (1Set=3 Nos.) lightening arrestors.
11 KV UnderGround Cable Work
A)11 KV UnderGround Cable Work on Eminanting Point (GSS)
Erection of 9.00 M PCC poles (200 KG) in allignment including excavation of pit in ground and back filling of soil consolidating each deposit layer of 0.15 mtr. by proper watering & ramming etc. in the length.
PCC Pole 9 mtrs long (200 KG)
In Hard soil
Erection of 11KV double pole line structure set for cut point complete on existing poles in all respect with clamp, Nut & bolts as required made from M.S. channel 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (105 KG. APPROX.) (Galvanized as per IS) Total weight = 101.38 Kg +4 Kg (Approx.)
Fixing of GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain/Guy insulator, Stay wire7/10 SWG
In Hard Soil
Laying, energisation & commissioning of underground cable for working voltage of 11KV aluminium conductors )IS 7098) cable XLPE Armoured as per IE rules and methods of IS:1255/JVVNL standards including excavation of 30CmX120Cm deep trench in land specified as below, 25Cm. Thick under layer of Sand "A" class brick covering ,refilling of earth in the remaining portion,making necessary connection including testing etc. as required and providing /fixing cable route indicators at every 30 mtr of cable & at every turn (As per latest specifications and design & drawing approved by Nigam). [road crossing of cable shall be in double walled corrugated pipe of 200MM diameter]
Under ground Cable of Size 3X185 SQ.MM for 11 KV
In open air and loop
Through HDD Vermier(Hard Rock)
FIXING OF G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK), AT THE STARTING AND FINISHING POINT OF 11 KV UNDER GROUND CABLES AND TO LAY & CLAMP VERTICALLY WITH THE EXISTING SUPPORT, INCLUDING LABOUR CHARGES.
GI PIPE for Cable Support at Pole ( Each 3.3 Mtr )
CABLE END TERMINATION KIT/ST JOINT, MAKING OUTDOOR JOINT FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE WITH OUTDOOR AND TERMINAL END PREPARATION OF JOINT AS PER MANUFACTURES KIT GUIDANCE AND DIRECTION INCLUDING PREPARATION OF CABLE END & TESTING ETC
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
installation of HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire (for earthing of 11 KV line) driven by mechanical means into earth hole (made by augering) and connecting the MS Rod type earthing set with cross arms, top hampers, PCC pole/structure & earth wire etc.
B) 11 KV UnderGround Cable Work
Laying, energisation & commissioning of underground cable for working voltage of 11KV aluminium conductors )IS 7098) cable XLPE Armoured as per IE rules and methods of IS:1255/JVVNL standards including excavation of 30CmX120Cm deep trench in land specified as below, 25Cm. Thick under layer of Sand "A" class brick covering ,refilling of earth in the remaining portion,making necessary connection including testing etc. as required and providing /fixing cable route indicators at every 30 mtr of cable & at every turn (As per latest specifications and design & drawing approved by Nigam). [road crossing of cable shall be in double walled corrugated pipe of 200MM diameter]
Under ground Cable of Size 3X185 SQ.MM for 11 KV
In open air and loop
Through open trench (Kaccha road/soil)
FIXING OF G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK), AT THE STARTING AND FINISHING POINT OF 11 KV UNDER GROUND CABLES AND TO LAY & CLAMP VERTICALLY WITH THE EXISTING SUPPORT, INCLUDING LABOUR CHARGES.
GI PIPE for Cable Support at Pole ( Each 3.3 Mtr )
CABLE END TERMINATION KIT/ST JOINT, MAKING OUTDOOR JOINT FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE WITH OUTDOOR AND TERMINAL END PREPARATION OF JOINT AS PER MANUFACTURES KIT GUIDANCE AND DIRECTION INCLUDING PREPARATION OF CABLE END & TESTING ETC
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
XLPE 3X185 SQ.MM H.S.S.T. JOINT
C) 11 KV UnderGround Cable Work for Railway Crossing
Erection of 9.00 M PCC poles (200 KG) in allignment including excavation of pit in ground and back filling of soil consolidating each deposit layer of 0.15 mtr. by proper watering & ramming etc. in the length.
PCC Pole 9 mtrs long (200 KG)
In Hard soil
Erection of 11KV double pole line structure set for cut point complete on existing poles in all respect with clamp, Nut & bolts as required made from M.S. channel 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (105 KG. APPROX.) (Galvanized as per IS) Total weight = 101.38 Kg +4 Kg (Approx.)
Fixing of GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain/Guy insulator, Stay wire7/10 SWG
In Hard Soil
Laying, energisation & commissioning of underground cable for working voltage of 11KV aluminium conductors )IS 7098) cable XLPE Armoured as per IE rules and methods of IS:1255/JVVNL standards including excavation of 30CmX120Cm deep trench in land specified as below, 25Cm. Thick under layer of Sand "A" class brick covering ,refilling of earth in the remaining portion,making necessary connection including testing etc. as required and providing /fixing cable route indicators at every 30 mtr of cable & at every turn (As per latest specifications and design & drawing approved by Nigam). [road crossing of cable shall be in double walled corrugated pipe of 200MM diameter]
Under ground Cable of Size 3X185 SQ.MM for 11 KV
In open air and loop
Through HDD Vermier(Hard Rock)
FIXING OF G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK), AT THE STARTING AND FINISHING POINT OF 11 KV UNDER GROUND CABLES AND TO LAY & CLAMP VERTICALLY WITH THE EXISTING SUPPORT, INCLUDING LABOUR CHARGES.
GI PIPE for Cable Support at Pole ( Each 3.3 Mtr )
CABLE END TERMINATION KIT/ST JOINT, MAKING OUTDOOR JOINT FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE WITH OUTDOOR AND TERMINAL END PREPARATION OF JOINT AS PER MANUFACTURES KIT GUIDANCE AND DIRECTION INCLUDING PREPARATION OF CABLE END & TESTING ETC
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
installation of HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire (for earthing of 11 KV line) driven by mechanical means into earth hole (made by augering) and connecting the MS Rod type earthing set with cross arms, top hampers, PCC pole/structure & earth wire etc.
Fixing of 11KV T&C Type composite polymer disc insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM)
Erection of PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986
D) 11 KV UnderGround Cable Work for NHAI/State Highway Crossing
Erection of 9.00 M PCC poles (200 KG) in allignment including excavation of pit in ground and back filling of soil consolidating each deposit layer of 0.15 mtr. by proper watering & ramming etc. in the length.
PCC Pole 9 mtrs long (200 KG)
In Hard soil
Erection of 11KV double pole line structure set for cut point complete on existing poles in all respect with clamp, Nut & bolts as required made from M.S. channel 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (105 KG. APPROX.) (Galvanized as per IS) Total weight = 101.38 Kg +4 Kg (Approx.)
Fixing of GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain/Guy insulator, Stay wire7/10 SWG
In Hard Soil
Laying, energisation & commissioning of underground cable for working voltage of 11KV aluminium conductors )IS 7098) cable XLPE Armoured as per IE rules and methods of IS:1255/JVVNL standards including excavation of 30CmX120Cm deep trench in land specified as below, 25Cm. Thick under layer of Sand "A" class brick covering ,refilling of earth in the remaining portion,making necessary connection including testing etc. as required and providing /fixing cable route indicators at every 30 mtr of cable & at every turn (As per latest specifications and design & drawing approved by Nigam). [road crossing of cable shall be in double walled corrugated pipe of 200MM diameter]
Under ground Cable of Size 3X185 SQ.MM for 11 KV
In open air and loop
Through HDD Vermier(Hard Rock)
FIXING OF G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK), AT THE STARTING AND FINISHING POINT OF 11 KV UNDER GROUND CABLES AND TO LAY & CLAMP VERTICALLY WITH THE EXISTING SUPPORT, INCLUDING LABOUR CHARGES.
GI PIPE for Cable Support at Pole ( Each 3.3 Mtr )
CABLE END TERMINATION KIT/ST JOINT, MAKING OUTDOOR JOINT FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE WITH OUTDOOR AND TERMINAL END PREPARATION OF JOINT AS PER MANUFACTURES KIT GUIDANCE AND DIRECTION INCLUDING PREPARATION OF CABLE END & TESTING ETC
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
installation of HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire (for earthing of 11 KV line) driven by mechanical means into earth hole (made by augering) and connecting the MS Rod type earthing set with cross arms, top hampers, PCC pole/structure & earth wire etc.
Fixing of 11KV T&C Type composite polymer disc insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM)
Erection of PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986
E) 11 KV UnderGround Cable Work for 33KV,11KV & LT line crossing
Erection of 9.00 M PCC poles (200 KG) in allignment including excavation of pit in ground and back filling of soil consolidating each deposit layer of 0.15 mtr. by proper watering & ramming etc. in the length.
PCC Pole 9 mtrs long (200 KG)
In Hard soil
Erection of 11KV double pole line structure set for cut point complete on existing poles in all respect with clamp, Nut & bolts as required made from M.S. channel 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (105 KG. APPROX.) (Galvanized as per IS) Total weight = 101.38 Kg +4 Kg (Approx.)
Fixing of GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain/Guy insulator, Stay wire7/10 SWG
In Hard Soil
Laying, energisation & commissioning of underground cable for working voltage of 11KV aluminium conductors )IS 7098) cable XLPE Armoured as per IE rules and methods of IS:1255/JVVNL standards including excavation of 30CmX120Cm deep trench in land specified as below, 25Cm. Thick under layer of Sand "A" class brick covering ,refilling of earth in the remaining portion,making necessary connection including testing etc. as required and providing /fixing cable route indicators at every 30 mtr of cable & at every turn (As per latest specifications and design & drawing approved by Nigam). [road crossing of cable shall be in double walled corrugated pipe of 200MM diameter]
Under ground Cable of Size 3X185 SQ.MM for 11 KV
In open air and loop
Through open trench (Kaccha road/soil)
FIXING OF G.I. PIPE OF 125 MM DIAMETER, B-CLASS (IS:1239 MARK), AT THE STARTING AND FINISHING POINT OF 11 KV UNDER GROUND CABLES AND TO LAY & CLAMP VERTICALLY WITH THE EXISTING SUPPORT, INCLUDING LABOUR CHARGES.
GI PIPE for Cable Support at Pole ( Each 3.3 Mtr )
CABLE END TERMINATION KIT/ST JOINT, MAKING OUTDOOR JOINT FOR11 KV ALUMINUM CONDUCTOR XLPE ARMOURED HT CABLE WITH OUTDOOR AND TERMINAL END PREPARATION OF JOINT AS PER MANUFACTURES KIT GUIDANCE AND DIRECTION INCLUDING PREPARATION OF CABLE END & TESTING ETC
XLPE 3X185 SQ.MM H.S. ON OUTDOOR TYPE
installation of HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire (for earthing of 11 KV line) driven by mechanical means into earth hole (made by augering) and connecting the MS Rod type earthing set with cross arms, top hampers, PCC pole/structure & earth wire etc.
Fixing of 11KV T&C Type composite polymer disc insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM)
Erection of PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986
11 KV Over Head Line Work
A) 11 KV Over Head Line Work
Conducting route survey as per approved route map and pegging of route with section point/double pole location
Trimming of tree branches and preparing route appraoches for the proposed line
erection of PCC Poles in allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs 200 Kg in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
PCC Pole 9 mtrs long (200 KG)
In Hard soil
Erection of 11KV double pole line structure set for cut point complete on existing poles in all respect with clamp, Nut & bolts as required made from M.S. channel 100 X 50 X ISMC ( 9.56 KG. PER MTR.) ISA M.S.ANGLE 65 X 65 X 6 MM, M.S.ANGLE 50 X 50 X 6 MM AND M.S.FLAT 50 X 6 MM (105 KG. APPROX.) (Galvanized as per IS) Total weight = 101.38 Kg +4 Kg (Approx.)
Drawing of overhead steel cored aluminum ACSR Rabbit conductor in all respect
Installation of Guarding brackets ( 1 set = 2 Nos.) at road/railway/line crossing as per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6 with GI Wire 8SWG using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
Fixing of 11KV V Cross Arm with Top Hamper with clamps made of MS Angle 65x65x6mm, clamp 50X6 mm, earth clamp 50X6 mm (Galvanized)
Fixing of channel bracket 1.4 mtr Long with clamp
Fixing of GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG
In Hard Soil
installation of HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire (for earthing of 11 KV line) driven by mechanical means into earth hole (made by augering) and connecting the MS Rod type earthing set with cross arms, top hampers, PCC pole/structure & earth wire etc.
Fixing of 11KV T&C Type composite polymer disc insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM)
Fixing of 11 KV composite polymer Pin Insulator complete in all respect
Erection of PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986
Erection of 8 SWG (4mm dia) GI Wire for continuous earthing of 11 KV Line hot dip (Galvanised)
Fixing of 11 kV Danger plate of size 200 X 250 mm complete in all respect
B) 11 KV Over Head Line Work for 33KV,11KV and LT Line crossing
ERECTION OF 11.4 MTR. LONG LATTICE TOWER MADE OF 50 X 50 X 6 MM M.S. ANGLE WITH 50 X 6 MM M.S. FLAT FOR BRACING INCLUDING SUPPLY OF FOUNADATION MATERIAL. THE WORK INCLUDES EXCAVATION OF PIT 1.50 X 1.50 X 2.10 M IN GROUND. THE TOWER WILL BE ERECTED BY PROVIDING CC GROUTING & MUFFED IN CEMENT CONCRETE OF MIX RATIO 1:3:6 HAVING SIZE OF 1.20 X 1.20 X 2.10 M OVER BASE CONCRETE OF 100 MM THICK IN MIX 1:5:10 AS PER IS SPECIFICATIONS. THE REMAINING POSITION OF THE PIT BE BACK FILLED WITH WATERING & RAMMING AND SURPLUS MATERIAL SHALL BE DISPOSE- OFF WITHIN LEAD OF 50 M. (TOWER WEIGHT - 449.85 KG approx)
IN ALL TYPES OF HARD SOIL
Fixing of 11KV T&C Type composite polymer disc insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM)
Fixing of 11 KV composite polymer Pin Insulator complete in all respect
Drawing of overhead steel cored aluminum ACSR Rabbit conductor in all respect
Fixing of GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG
In Hard Soil
Erection of 8 SWG GI Wire (Galvanised)
installation of HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire (for earthing of 11 KV line) driven by mechanical means into earth hole (made by augering) and connecting the MS Rod type earthing set with cross arms, top hampers, PCC pole/structure & earth wire etc.
Installation of Guarding brackets ( 1 set = 2 Nos.) at road/railway/line crossing as per span of 11 KV made of M.S. Angle 65X65X6 mm with clamps made of Flat 50x6 with GI Wire 8SWG using Eye Hook 300X16 mm (75% Thread with Nut of Suitable Size) (galvanized)
Fixing of channel bracket 1.4 mtr Long with clamp
Erection of PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994 . All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986
Fixing of 11 kV Danger plate of size 200 X 250 mm complete in all respect
3-Phase DTR
Erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs and 1.2x0.6x1.35 cum PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
PCC Pole 9.0 mtrs long.(200 Kg.)
In Hard Soil
Drawing of overhead steel cored aluminum ACSR Rabbit conductor in all respect
Fixing of 11/0.4 KV SubStation structure set for Three Phase 25 KVA transformer on double poles in all respect. weight(As per Specification and Drawing without GO channel) Approx =166.67 kg (All galvanized as per relevant IS)
Fixing of 11/0.4 KV SubStation structure set for Three Phase 63 KVA transformer on double poles in all respect. Weight (As per Specification and Drawing with GO channel) Approx =219.54 kg(All galvanized as per relevant IS)
Installation of 11 /0.4 KV Al wound, Three Phase Distribution Transformer with M&P box
25 KVA (Completely self protected with provision of LT Bushing Box)
Fixing of 11KV ( with 9 x 24 KV Post Insulator ) 400 Amp. GO double break without EB Isolator on existing bracket complete in all respect as required including hardware etc.
Fixing of horn gap sets on existing brackets in all respect as required including hardware nut & bolt & washer etc. ( with 6 x 24 KV Post Insulator ) 1 Set=3 NOS
installation of HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire (for earthing of 11 KV line) driven by mechanical means into earth hole (made by augering) and connecting the MS Rod type earthing set with cross arms, top hampers, PCC pole/structure & earth wire etc.
Fixing of GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain/Guy insulator, Stay wire7/10 SWG
In Hard Soil
Fixing of 11KV T&C Type composite polymer disc insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM)
Fixing of 11 KV composite polymer Pin Insulator complete in all respect
Fixing of 11 kV Danger plate of size 200 X 250 mm complete in all respect
Erection of PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor,
Erection of LT XLPE Cable
Size 4CX70 SQ. mm
Size 4CX120 SQ. mm
Laying of overhead ABC(Aerial bunched cable) with Bare Messenger
3C X25 +1CX25 sqmm
Erection and foundation of LT Supply Pillar Box of 200 Amp. capacity as per specification of Nigam . Each Base should be grouted including excavation , bricks , sand, cement masonary of size 4"X3"X10" and 3' in ground & 1.5' above road level with muffing to support & mounting the Pillar . The masonary will have 4"X4" opening 2" below ground level two in rear side & one each in the remaining sides to facilitate entry & exit of incoming & outgoing cables inside the pillar box shall be connected to DP Earth with 7/10 SWG Stay Wire & Lugs duly bolted on the place meant for XLPE cables inside the box shall be fixed with clamps making connections / jumpers by Aluminium lugs / PG Clamps of required size on LT Distribution mains on one end & with MCB / with isolator on the other end. Lugs should be crimped with crimping tools including cost of lugs, etc.
1-Ph S/S structure for shifting of 1-Ph Distribution Transformer
erection of PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.5 cum. for 9 mtrs and 1.2x0.6x1.35 cum PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
PCC Pole 9.0 mtrs long.(400 Kg.)
In Hard Soil
Fixing of 6.35/0.24 KV SubStation structure set for single phase Transformer on single 9Mtr, 400KG PCC pole complete in all respect made of MS channel, MS angle and MS flat etc. including nut, bolt, flat and spring washer (as per latest specifications and drawings adopted & approved by NIGAM)
Fixing of 11KV T&C Type composite polymer disc insulator complete including all accessories like hardware fitting (as per latest specifications and drawings adopted & approved by NIGAM)
Fixing of 11KV 100 Amp drop out cum isolator with 3.0 Amp fuse and 12KV post insulator including Nut, Bolt & Washers (as per latest specifications and drawings adopted & approved by NIGAM)
Laying of overhead ABC(Aerial bunched cable) with Bare Messenger
1C X25 +1CX25 sqmm
Fixing of 11 kV Danger plate of size 200 X 250 mm complete in all respect
Fixing of GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain/Guy insulator, Stay wire7/10 SWG
In Hard Soil
installation of HD Galvanised M.S.Rod type earthing set (including nuts & bolts) made up of M.S.Rod 20 mm dia. 3 meter long alongwith earthing clamp & 8 SWG earth wire (for earthing of 11 KV line) driven by mechanical means into earth hole (made by augering) and connecting the MS Rod type earthing set with cross arms, top hampers, PCC pole/structure & earth wire etc.
Drawing of overhead steel cored aluminum ACSR Rabbit conductor in all respect
Erection of PG clamps (For Rabbit) made of aluminum alloy as per IS:617-1994. All ferrous metal part intended for outdoor use except those made of stainless steel shall be protected by hot dip galvanizing in accordance with IS 2633-1986(latest amended) com plete in all respect as required for ACSR conductor,
LT Ariel Bunch Cable
Erection of 9.0 Mtr.long (200 Kg.) PCC Poles in all types of soil & allignment including excavation of pit size 1.2x0.6x1.35 cum for 8 mtrs PCC poles in ground and back filling soil consolidating each deposit layer of 0.15 mtr. by watering and ramming etc. in the length.
PCC Pole 9 mtrs long (200 KG)
In Hard soil
Laying of overhead ABC(Aerial bunched cable) with Bare Messenger
3C X25 +1CX25 sqmm
3C X50 +1CX35 sqmm
Fixing of GI stay set (Galvanized) complete (stay rod 16 mm dia,1.8 m long,anchor plate 300X300X4 mm,12 mm dia turn buckle) including stay clamps, strain insulator, Stay wire7/10 SWG
In Hard Soil
Fixing of Dead end (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS)
Fixing of Suspension (anchor) clamps for insulated or bare messenger + one Pole Bracket + 1.5 mtr S.S. (Stainless Steel) Strap + two SS Buckles as per NFC Standard suitable for AB Cable Complete in all respect (galvanized as per IS)
Fixing of LT insulation piercing connectors NFC Type A (main to tap) (main 16-50 mm2, Tap off 2.5-16 mm2)
Fixing of LT insulation piercing connectors NFC type B ( main to main) (size 16-50 mm2)
Fixing of LT bracket with clamp 600 mm (2ft) and all accessories.
Fixing of LT shackle insulator with hardware and all accessories.
Description of Work / Item(s)
Total price of Supply (BoQ1/Schedule-1) for feeder segregation work
Total price of Erection (BoQ2/Schedule-2) for feeder segregation work
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.79 MB
FS_RFB_P1.pdf
Tender Documents • 1.52 MB
FS_RFB_P2_SOW.pdf
Additional Documents • 1.41 MB
FS_RFB_P3.pdf
Additional Documents • 2.07 MB
SBD_PART2_TS_annexureB.pdf
Additional Documents • 5.68 MB
DRAWINGS_AnnexureC.pdf
Additional Documents • 10.89 MB
BOQ_851359.xls
BOQ • 0.60 MB
Tenderdocument.pdf
Tender Documents • 2.07 MB
BOQ.xls
BOQ • 0.60 MB
Tenderdocument_2.pdf
Tender Documents • 1.41 MB
Tenderdocument_3.pdf
Tender Documents • 1.52 MB
Tenderdocument_4.pdf
Tender Documents • 10.89 MB
Tenderdocument_5.pdf
Tender Documents • 5.68 MB
Download all tender documents and submit your bid