Loading…
Loading…
Tender Value
₹44.4 L
EMD Value
₹88,700
Closing Date
22 Jul 2026, 6:00 pm
Garrison Engineer Army Trivansrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum-695006
SPECIAL REPAIR FOR CONVERSION OF LT OH LINES TO LT UG CABLES, SPECIAL REPAIRS TO STREET LIGHTS FROM STN HQ MAIN GATE TO 6 GARHWAL OFFRS MESS AND SPL REPAIR TO EXTERNAL ELECT AT PRE-PRIMARY WING OF APS AT PMS UNDER GE (ARMY) TRIVANDRUM
2026_MES_776284_1
8372/E8
Open Tender
Electrical and Maintenance Works
180 days
Trivandrum
As per tender documents
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹88,700
Yes
3 Jul 2026
3 Jul 2026
24 Jul 2026
3 Jul 2026
22 Jul 2026
17 Jul 2026
3 Jul 2026 - 10 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling old unserviceable insulators of any type and size complete all as specified and directed. | 25 | Each | - | - |
| 2 | Dismantling ACSR conductor of any size from LT OH line complete all as specified and directed. | 3.8 | Quintal | - | - |
| 3 | Dismantling old GI earth wire conductor of any size from LT OH line complete all as specified and directed. | 1 | Quintal | - | - |
| 4 | Dismantling GI pipe light grade size 40/ 50/ 80 mm dia from trenches poles complete all as specified and directed. | 40 | Running Metre | - | - |
| 5 | Dismantling old unserviceable cross arms back plate, nuts, bolts etc any size complete all as specified and directed. | 3 | Quintal | - | - |
| 6 | Dismantling old unserviceable cable/ service cables of any size complete all as specified and directed. | 350 | Running Metre | - | - |
| 7 | Dismantling unserviceable broken electric poles/ struts any size and type with disconnecting all connections, demolition of concrete foundation including excavation, earth work, as required and removing the same from site complete all as specified and directed. | 28 | Each | - | - |
| 8 | M&L for cutting of metallic road/ hard standing/ hard rock/ wall up to a size not exceeding 20 cm width and not exceeding 60 cm in depth for laying of protection pipe for cable including making good the disturbed road/ hard standing by providing PCC (1:2:4) type B1, 20 mm graded crushed stone aggregate upto existing surface level or removing any type of tiles carefully and refixing properly as per existing surface including suitable size of GI pipe (if necessary) complete all as specified and directed.
Note:
1. If damage/ break any type of tiles while removing, the contractor shall replace the broken tiles with new one.
2. The quoted rate is included for all materials/ T&P/ machinery used in this item, no material can paid/ measured separately.
3. All the removable tiles/ refixable material shall kept carefully at a safe place for refixing with in this quoted rate.
4. GI pipe shall measured and paid separately under relevant item. | 20 | Running Metre | - | - |
| 9 | M&L for boring holes 51 metre long horizontally under road (Poojapura to Thirumala road near ARO office and AGE (B/R) MAP TVM) without damaging the surface of road (Minimum 1 metre below the road/ foot path) with the help of HDPE pipe of 160 mm dia for crossing of UG cable from Poojapura to Pump house new panel to ARO office and LAO office existing panel to AGE (B/R) MAP Tvm existing panel complete all as specified and directed.
Note: Contractor should liaise with state government authority and take permission for boring below the road for crossing cable in consultation with the Engr-in-charge. | 51 | Running Metre | - | - |
| 10 | Material and labour for laying XLPE insulated, PVC inner sheathed, extruded PVC outer sheathed, LT underground cable, armoured with galvanised wire, heavy duty electric cable with stranded aluminium conductor of cross-sectional area 2 core 10 sqmm, 1100 volts grade, as per IS 7098 (Part 1) 1988, laid in trench, fixed on wall/pole drawn through pipe etc including of provision of lugs & testing, complete all as specified and directed. | 1,950 | Running Metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
8372Tender.pdf
Tender Documents • 0.45 MB
BOQ_869291.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid