Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.9 LAccepted-AOC INDEX NO B 48 HQ CE SWC JAIPUR A 202 RATHRAM PANORAMA GALA GIMAKHANA ROAD NEAR AMMANJARI BUNGLOWS SOUTH BOPAL AHMEDABAD 380058 | AHMEDABAD | AHMEDABAD | GUJARAT | 380058 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹34.7 L+₹1.7 L (5.31%)Rejected-Finance | L2 | Rejected-Finance Rejected due to bidder not L1 | |
| 3 | L3₹36.0 L+₹3.1 L (9.34%)Rejected-Finance | L3 | Rejected-Finance Rejected due to bidder not L1 | |
| 4 | L4₹37.6 L+₹4.7 L (14.1%)Rejected-Finance | L4 | Rejected-Finance Rejected due to bidder not L1 |
Tender Value
₹38.0 L
EMD Value
₹76,020
Closing Date
10 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Ravinder Sharma
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
PROVN OF 01 ROOM OF 150 SQM FOR SETTING UP APHAERSIS LAB AT AHMEDABAD.
2024_MES_653668_1
8203/E8
Open Tender
Civil Works
Works
270 days
GE ARMY AHMEDABAD
As per NIT
9 documents required · 9 mandatory
₹500
GE (Army) Ahmedabad
₹76,020
Yes
1 Mar 2025
14 May 2024
13 Jun 2024
14 May 2024
10 Jun 2024
27 May 2024
14 May 2024 - 27 May 2024
Amount
Demolition of Brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
site clearance in soft/ loose soil complete all as per specified and directed
Surface dressing n exc 15 cm deep and getting out in soft/loose soil soil complete all as per specified and directed
M&L 100mm thick PCC 1:4:8 using 40 mm graded stone aggregate as in sub base complete all as specified and directed
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as per specified and directed
Removing excavated soil exc. 250m but n.exc 500m and depositing where directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, etc., and getting out in any type of soil.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in surface channel ,foundations, filling and mass concrete.
M&L brickwork with sub class B bricks straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6 by using old size bricks complete all as per specified and directed
M&L for Plain Cement Concrete Type B1 1:2:4 (using 20 mm graded granite stone aggregate) as in coping including use and waste of form work.
M&L for 15mm thick rendering in CM 1:4 with water proofing compound @ 3% by weight of cement on block masonary/concrete surfaces and finished even and smooth without using extra cement.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as per specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as per specified and directed
Removing Excavated soils exceeding 1.5 KM but not exceeding 5 KM and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as per specified and directed
M&L for Precast cement concrete 1:2:4, type B1 (Using 20 mm graded granite stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as per specified and directed
S&F Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to complete all as per specified and directed
Supply only water proofing compound complete all as per specified and directed
M&L for PCC (1:3:6) type C2 ,40mm graded aggregate.,as in concrete bed to drain pipes including forming cradles after they are laid & tested for 150 mm bore for NP2 pipes complete all as per specified and directed
M&L for 150mm internal dia of RCC Class NP -2 pipe laid in trenches, jointed as specified and as directed
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed.
M&L for cement concrete in foundation PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundations filling and mass concrete.
M&L mild steel TMT bars 10mm dia and over cut to length bent to shape required & cranking, binding, spirally for hopping for hooking ends & binding with MS steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Surface Excavation N.exc (not Exceeding) 30 Cm Deep And Averaging 15cm Deep And Getting Out In Soft/loose Soil complete all as per specified and directed
Earth Work In Excavation By Mechanical Means (hydraulic Excavator) Means Over Areas (exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5m, As Directed ( All Kinds Of Soil ) complete all as per specified and directed
All as per item No 1.23 above but depth exc 1.5m but not exc 3.0m complete all as specified and directed.
Excavating in post holes (or similar holes) in hard/dense soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm etc complete all as specified and directed.
M&L for Treating the back fill in Contact with foundation at the rate of 7.5 Litres Of Emulsion Per Square Metre of Vertical Surface (area of the Sub Structure in Contact with backfill to be Measured) complete all as per specified and directed
M&L for treating the Top Surface of filled earth at the rate of 5 Litres Of Emulsion Per Square Metre of Surface complete all as specified and directed
M&L for treating the Soil along with External Perimeter of Building at the Rate of 2.25 Litre of Emulsion Per Metre of the Perimeter Wall complete all as specified and directed
M&L for treating the Soil Under Plinth Protection at the rate of 5 Litres Of Emulsion Per Square Metre Of Surface Area complete all as specfied and directed
Removing Excavated Soil not exc. 50m and depositing where Directed at a Level n exc. 1.5 M Above the Starting Point complete all as per specified and directed
M & L RCC- M-25 (design Mix) Using (20mm Graded Aggregate)for Foundation ,including rafts ,footings,foundation, beams, plinth beam ,bases for column, etc basement slabs, under-reamed piles and mass concreteas , complete all as specified and directed
Form Work for rough finished surfaces to sides of concrete foundations, footing,bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specfied and directed
S&F mild steel 5 to 10mm dia screw bolts machine made with hexagonal or square heads at one end and screwed both the ends, each screwed end to fitted with washers and one hexagonal or square nut n,exc 5cm long etc complete all as specified and directed.
S&F Mild Steel of gde Fe 410-W as in plain plates cut to required sizes including forming holes without any attachement etc complete all as specified and directed.
M & L Rolled steel sections Fe-290 (Gde E-165) in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connectiong plates complete including cutting, grinding, welding etc as required complete all as specified.and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed.
S&F Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L preparation of newly steel surfaces exc 10cm width or girth and applying 2 coats of synthethic enamel paint over a coat of primer etc complete all as specified and directed.
M&L mils steel TMT bar 8mm dia or above as in stirrups bending and binding with incl mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M & L RCC- M-25 (design Mix) Using 20mm Graded Aggregate For Column complete all as specified
Form Work to sides of pillars,post, struts, piers,column and stanchions Square,rectangularor polygonal for Rough Finished Surfaces Of Concrete Measured Flat For Column complete all as specfied
M&L for Brickwork With Fly Ash Bricks, Straight Or Curved On Plan Exc 6m Mean Radius, Built In Cm (1:6) complete all as per specified and directed
M & L Rcc- M-25 (design Mix) Using 20mm Graded Aggregate For beams , cantilever, bressuremmers, lintel over 1.5m span complete all as specfied and directed.
Form Work to flat surfaces of lintel band for rough finishes, sides and soffits of floor or roof beams,beam haunching, girders, bressurmmers, lintel, cantilever, shelves including supports overhung, etc, also splays between floors and beams, etc complete all as specfied and directed.
M & L RCC- M-25 (design Mix) Using 20mm Graded Aggregate For Chajja complete all as per specified and directed
M & L RCC- M-25 (design Mix) Using 20mm Graded Aggregate For Slab Beam complete all as per specified and directed
M & L RCC- M-25 (design Mix) Using 20mm Graded Aggregate For Slab complete all as per specified and directed
Form Work For Rough Finished Surfaces Of Concrete tosoffits of suspended slab,floor slab,landings and similar work not exceeding Measured Flat For Slab 200mm thick (horizontal or sloping) complete all as specfied and directed
M & L Rcc- M-25 (design Mix) Using 20mm Graded Aggregate For Parapet complete all as per specified and directed
Form Work For Rough Finished Surfaces Of Concrete Measured Flat For Parapet complete all as per specified and directed
M & L 10 Mm Thick 1:6 Cm Internal Plaster On Fair Faces Of Walls Finished Even And Smooth (without Using Extra Lime Or Cement) complete all as per specified and directed
M & L for 5 Mm Thick 1:3 Cm Plaster On Ceiling. Finished Even And Smooth (without Using Extra Lime Or Cement) complete all as per specified and directed
M & L for 15 Mm Thick (10 Mm + 5 Mm 1:6 Cm) External Plaster On Fair Faces Of Walls Finished Even And Smooth (without Using Extra Lime Or Cement) complete all as per specified and directed
S&F aluminium powder coated section size 65 x 44 x 1.48 mm for partition walls fixed type in panels square or reqtangular section including gasket aluminium cleat 6 mm dia rounded bars, 8mm thick tinted glass board panes fixed complete all as per specified and directed
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and complete all as per specified and directed
S&F Powder Coated Aluminium (minimum Thickness Of Powder Coating 50 Micron) For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges/ Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/neoprene Gasket Required (fittings Shall Be Paid For Separately) With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is: 733 And Is:1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.e. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing/ Paneling, C.p. Brass/ Stainless Steel Screws All Complete As Per Architectural Drawings And complete all as per specified and directed
S&F sheet glass ordinary quality with putty 5.5 Mm Thick Plain Sheet Glass N Exc 0.5 Sqm In Each Pane complete all as specified
M&L for preparation of newly plasterd surfaces and applying Two Coats Of Oil Bound Distemper Over One Coat Of Wall Primer All As Specified and directed
M&L for preparation on newly platerd surfaces of ceiling and applying Three Coats Of Lime Wash All As Specified and directed
M&L for preparation on newly plasterd surfaces and applyingTwo Coats Of Cement Based Paint Over One Coat Of Wall Primer All As Specified and directed
M&L for Virified Ceramic Tiles 10 Mm Thick (square/ Rectangular) Polished, Area Of Each Tiles Exceeding 0.36 Sqm But Not Exceeding 0.42 Sqm, In Floors Etc. Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match complete all as per specified and directed
M&L for Screed Bed Or Bedding Layer Of Mortar 15 Mm Thick For Laying Floor Finishes Set In Cm (1:6) complete all as per specified and directed
M&L for Cement Concrete 25mm Thick 1:2:4 Type B0 (12.5mm Graded Aggregate) as in floors complete all as per specified and directed
M&L for Cement Concrete 75mm Thick 1:4:8 Type D2 (40mm Graded Aggregate) As In Sub Base complete all as per specified and directed
M&L for 100mm thick type B-2 1:2:4 using 40mm graded stone aggregate as in floor Cement concrete in foundations, filling and mass concrete complete all as specified and directed
S&F for plastic dividing strips, 1.5mm thick 38mm wide laid in floors complete all as per specified and directed
M&L for Machine Cut Kota Stone Slab Flooring 20-25mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing complete all as per specified and directed
M&L for Screed Bed Or Bedding Layer Of Mortar 20 Mm Thick For Laying Floor Finishes Set In Cm (1:3) complete all as per specified and directed
M&L for Glazed Ceramic Tiles In Vertical Surface 350x 250x 7 Mm/ 450x 350x 7mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match complete all as per specified and directed
M&L for Screed Bed Or Bedding Layer Of Mortar Cm(1:3) 10mm Thick For Laying Floor Finishes As In Base complete all as per specified and directed
M&L for Kota Stone Slab 20-25mm Thick In Riser Of Steps, Skirting, Dado And Pillar Laid Over Cement Screed And Jointed complete all as per specified and directed
M & L 75mm Thick Plinth Protection Pcc (1:3:6) Using 20mm Graded Aggregate (0.90m Wide) complete all as per specified and directed
M&L for Hardcore Of Guage Exc 63mm But N Exc. 100 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rolled/rammed To A True Surface complete all as per specified and directed
M&L for APP Based Polymeric Membrane Minimum Weighing 3kg/sqm And Minimum 3mm Thick Reinforced With Polyster Non Wove Fabric (wt. Not Less Than 150 Gms/sqm) Laid On Primed Surface By Torched Application Complete And Finally Finished As Per Manufacturers Instructions
M&L for Screed Bed Or Bedding Layer Of Mortar Cm(1:3) 10mm Thick For Laying Floor Finishes As In Base complete all as per specified and directed
S&F Pvc Flush Pipe of polyethylene of low or high density pipe Of 32 Mm Dia for sink complete all as per specified and directed
S&F cast iron floor trap , with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) 75 mm dia complete all as per specified and directed
S&F Wash hand basin Vitreous China White Size 550x400 including brackets cutting for and pining in ends of brackets or erecting stand but exculsive of fixing of supply complete all as per specified and directed
S&F Pillar Tap cast copper alloy with caspstan heads chromium plated Fancy type screwed down high presure with or without lettered HOT or Cold with long screwed shyanks and fly nuts screwed for iron pipe and fixed complete all as specified
S&F Bib Taps, Cast Copper chromium Plated Alloy With Crutch Or Butterfly Handle screwed down for iron pipe or for brass ferrule and fixed to 15mm bore pipe complete all as per specified and directed
S&F PVC (SWR) pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floor complete all as per specified and directed
S&f Sinks With Drainage Board Made Of Stainless Steel Lmm Thick Kitchen Or Laboratory With Plugs, Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915mm X 460mm Bowl Size 410mm X 330mm X 160mm complete all as per specified and directed
S&F GI tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed
(a) 15mm bore of pipe
(b) 20mm bore of pipe
S&F Rotational moulded polyethylene water storage tank of 500 Litre Capacity vertical with closed top hoisted and fixed in position allas specified in SSR-I complete all as per specified and directed
S&F Ball Valve high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe and fixed(minimum weight 25mm - 455 gm complete all as specifed and directed For Water Tank complete all as per specified and directed
M&L for point wiring with 1100 volts grade PVC insulated FR-LS multistranded copper conductor cable 1.5 sqmm (Phase - R Y B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked with all conduit fittings / fixing accessories and sunken galvanized pressed modular steel terminal boxes of thickness not less than 1.2 mm covered with suitable and required size of modular box, plate with cover for mounting modular switches, sockets, fan regulators complete including making good the wall surfaces with matching colour on wall for the following
(a) One light point controlled by one switch.
(b) One ceiling/ex fan point controlled by one switch.
(c) One socket outlet 6 amp controlled by one switch on the same board with other switches.
(d) One socket outlet 6 amp controlled by one switch on indepdendent board.
M&L for Point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with suitable and required size of modular box for one 16 amp socket outlet controlled by one switch on independent board complete all as per specified and directed
S&F modular switch one way 6 amp 1 module all as specified and directed
S&F modular switch one way 16 amp 1 module all as specified and directed
S&F modular socket 6/16 - 2/3 pin combined 2 module all as specified and directed
S&F modular socket 6 amp 3 pin 2 module all as specified and directed
S&F Ceiling rose 6 amp, 3 plates polycarbonate body complete
S&F modular hum free electronic step fan regulator, 100 watt 2 module all as specified and directed
Supply and fixing sheet metal enclouser single pole and neutral with a 2 pin and earth plug and socket 20 A 240V complete with one single pole MCB of capacity 20 A complete all as specified and directed.
S&F LED batten (1.2 m) made of Aluminium housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 100+ lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI>80, THD < 10% and PF > 0.95 complete all as per specified and directed
S&F MCB distribution board SPN, 240 volts, 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
S&F LED 20W bldg security lights made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LED's with secondary optics and IP65 protection complete with fixing arrangement and connections as directed
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:-
(a) 2x6 sqmm + 1x6 sqmm earth continuity conductor in 20 mm dia conduit..
(b) 2x4 sqmm + 1x4 sqmm earth continuity conductor in 20 mm dia conduit..
S & F distribution board iron clad, double door with IP-43 IK-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link complete with one MCCB 4 pole 415 Volts 160 Amps rating with rupturing cap 16 KA of the same make as of distribution board & including cutting chases to wall for fixing DB, complete all as per specified and directed
Supply, install, commissioning and testing of commercial Air curtain unit suitable for door size 52''X84'' for prevention of dust and conditioned air losses, single phase, 220 V, 50 HZ, made out of MS/CRCA sheet of minimum thickness 18 gauge finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, Aluminium alloy fans and single phase electric motor, nozzles etc, complete with fittings and accessories so as to produce 1 - 1.5 m/sec air velocity at floor level for door opening as specified.
M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-5 of SSR Part-I. all specified
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
(a) Single pole 6 to 32 amp.
(b) Double pole 32 amp.
S&F ceiling fans complete with blades, down rods and accessories, 230V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and laying DWC(Double wall corrugated) HDPE pipe,ISI marked,IS 16205(part 24):2017 part 2 of outer dia 50 mm and inner dia 38 mmwith smooth internal and profiled external surface for non pressure underground cable including all connected acceseries like coupler,o-ring etc complete all as specified and directed Make : Rex Polyextrusion/Gemini/Astral
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50sq. mmX 3.5Core complete all as per specified and directed
Cutting existing steel tubing for alterations or aditions of pipe size 40/50 mm bore and screwing complete all as per specified and directed
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm (3/4”) dia complete all as per specified and directed
Supply and fix Valve, globe conforming to IS 9338, 50mm (2”) dia pipe complete all as per specified and directed
S&F 25 mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type chromium plated,25 mm dia complete all as per specified and directed
SNEH TRADERS
suryabuildtechdevlopers
Shreeganesh Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .