Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹18.0 L+₹1.2 L (7.11%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹19.0 L+₹2.2 L (13.2%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹19.3 L+₹2.5 L (15.0%)Rejected-AOC SHIVAJI NIWAS VILL CHIMBALHAR P O GEETA PEETH PALAMPUR HP 176061 | KANGRA | HIMACHAL PRADESH | 176061 | L4 | Rejected-AOC L4 | |
| 5 | L5₹19.8 L+₹3.0 L (18.0%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹20.1 L
EMD Value
₹40,200
Closing Date
14 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE YOL CANTT
HQ CWE YOL CANTT
SPL REPAIRS TO BLDG NO T 06 (OTM ACCN) IN 25/4 CAMP AT YOL CANTT
2020_MES_351564_1
CWE/Y-38/2020-21
Open Tender
Civil Works
Works
180 days
YOL CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (KH) Yol
₹40,200
Yes
19 Sept 2020
18 Jul 2020
15 Aug 2020
18 Jul 2020
14 Aug 2020
31 Jul 2020
60 days
Amount
Schedule "A" Part-I (B&R and E&M Works):- Taking down chowkhats or frames not exc 1.50 sqm with shutters (without taking off shutters from the frames) all as specified & directed.
Taking down chowkhats or frames exc 1.50 sqm but n.exc 4.00 sqm with shutters (without taking off shutters from the frames) all as specified & directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (Reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (But not backing), removing and rubbish of the premisses, complete all as specified.
Taking down cement plaster on brick or stone walls, ceiling, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
Demolition of stone slabs and tiles of any description and thickness in floors, aprons, laid, bedded and pointed in any mortar, all as specified.
Demolition of brick work or stone masonry built in cement mortar including all quoines arches,pillar etc but excluding ashlar facing, dressed stone work and precast concrete articles complete all as specified.
Dismantling posts or struts (wood, steel or RCC) any section, taking out embedded portion in concrete including necessary earth work i.e preparing post holes for new posts, complete all as specified and directed.
Dismantling timber scantling in any position over 40 sq. cm and over in section, in framed work, all as specified.
Dismantling timber scantling in rails, posts, fillets, rafters, purlins etc. under 40 sqcm in section, in unframed work, complete all as specified.
Dismantling boarding/ weather boarding/ wall panelling any description, fixed in any position with nails, all as specified.
Dismantling plain or corrugated steel sheeting any guage, thickness including Nainital or similar pattern roof covering, all as specified.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness including cover fillets in ceiling, all as specified.
Taking up or down 15 mm bore steel tubing with connections for cleaning for refixing or removing to store yard complete all as specified.
Taking up or down 20 mm bore steel tubing with connections for cleaning for refixing or removing to store yard complete all as specified.
Dismantling cast iron/ PVC pipes 100 mm-110 mm bore fixed to walls or laid in floors or trenches including connections, complete all as specified and directed.
75 mm thick plain cement concrete M-10 (Nominal mix), Type C-2 (using 40mm graded brick aggregate) as in foundations/ sub base of floors or in mass filling all as specified and directed.
Plain cement concrete M-15 nominal mix, type B-1 using 20 mm graded mechanically crushed stone aggregate as in surface channel and drains all as specified.
25mm thick cement concrete M-15 (Nominal mix) type B-0 (using 12.5mm graded crushed stone agg ) as in flooring, finished even & fair complete all as specified and directed.
Plain cement concrete M-10, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 50mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
Plain cement concrete M-15, nominal mix, B-I using 20mm graded mechanically crushed stone aggregate as, in lintels upto 1.5 metre clear span, steps, seismic and other similar bends, coping, bands plates for serving hold fasts, filling in mild steel frames etc. and the like including weathering slighting rounded or chamfered angles and throating complete all as specified.
Providing precast cement concrete M-15, nominal mix, type B-1 (using 20mm graded mechanically crushed stone aggregate) but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set in cement mortar 1:4, all as specified.
Precast cement concrete M-10, nominal mix, type C-1 (using 20mm graded mechanically crushed stone aggregate) as in window or door cills, lintels, landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces, set in cement mortar 1:4 (1 cement : 4 coarse sand), all as specified. Note for Serial Item No 22 to 24:- (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately.
Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 (01 cement : 06 coarse sand) all as specified & directed.
Walling random rubble masonry with best quality locally available stone (bakloh stone), uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 (1 cement : 6 coarse sand), all as specified.
Walling random rubble masonry with best quality locally available stone, uncoursed, well bonded, bedded, solidly hearted and built in cement mortar 1:6 (1 cement : 6 coarse sand), but except stone all as specified. Note: Servicable stone retreived from demolition under respective Items of BOQ shall be reused.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley/ eaves/ rain water gutters, drip and straight flashing (length and girth as fixed), fixed with self tapping screws all as specified
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-A, steel work duly painted with one shop coat of zinc chromate primer including preparation of surfaces all as specified.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to grade Fe 410 -W (Gde-E- 250) quality-A, steel work duly painted with one shop coat of zinc chromate primer including preparation of surfaces all as specified.
Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to grade Fe.410.Gde-E-250 A, steel work duly painted with one shop coat of zinc chromate primer including preparation of surfaces all as specified.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cms but n exc 15cms long, diameter of neck in 5mm to 10mm, all as specified.
GI snap grid frame work for ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 mm and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete size of grid 605 x 605 mm all as specified and directed .
4 mm thick non asbestos fibre cement building boards (Decorative E-board) as in ceiling fixed or laid/ inserted to timber/ GI/ aluminium frame work fixed with nails, all as specified.
Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 50mm thick sand cushion, joints of tiles filled with dry sand and compacted with mechanical vibrator complete all as specified and directed. Note:- PCC sub base 75 mm thick shall be paid under respective Item of BOQ.
TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hoping for columns and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified.
Form work to soffits of suspended slab such as roof slabs, floor slab landing etc and similar works not exceeding 200mm thick (horizontal or sloppy) for rough finished surfaces of concrete.
Factory made 2nd class hard wood (Sal/ Hollock) plain, framed, panelled 35mm thick shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, all as specified and directed.
Factory made 35 mm thick second class hard wood (Sal) glazed and skelton door shutters open rebated and prepared to receive glass gauge etc (with out sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass or gauge etc., size of members of shutter as specified in clause 8.24 (a) of part-I, fitted to chowkats, complete all as specified.
Steel window 1.25mm thick box type (Primer coated) ERW hollow P section of size 85mm x 35mm double rebated comprises gauged, glazed skelton shutter ERW Sec 50mm x 20mm and 1mm thick with two openable leaf consiting two Nos sash bar of T-Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T-section of size 30mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC M-15, type B-0 (04 No's for each window, steel duly painted with one shop coat of zinc chromate primer on prepared surfaces) and finishing the surfaces to match with existing including following fitting welded to frame shutter:- (i) Hold fast, 150mm long of 12mm x 3mm made to shape -04 Nos per window. (ii) Handle of Z section 20mm x 25mm, 100mm long -1 No per leaf. (iii) MS tower bolt 150mm long - 2 No per leaf (iv) Z section 20mm x25mm, 100 long stopper - 1 No per leaf. (v) Cleat 65mm long of hollow square 15mm x 20mm x 63mm welded to hinge -1 No per leaf. (vi) Mild steel pintle hinge of size 75mm x 12mm - 2 Nos per leaf. (vii) Flat iron fillets of size 20X3 mm for fixing wire gauge. (viii) Fabrication & fixing arrangement as per drg No. CEPZ/ TD 06/07. Make : As per Appendix 'C'. Note:-(i) Above referred drawing has not been made part of tender. The same can be seen in the office of GE during working hours on any working day.
Mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed ballusters walk ways; railings; flat iron for framing grills, framework of water tanks and similar work conforming to Fe.290. Gde-E-165, all as specified. Note:- Size of flat iron for fixing grills shall be 20X5mm.
Pressed steel frames for doors of size 125 mm X 60 X 1.25 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed including one shop coat of red oxide zinc chrome primer and filling frame with PCC m-15, type B-0 using 12.5 mm graded crushed stone aggregate, all as specified and directed.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks of galvanised wire staple fixed with stainless steel wire staples all as specified and directed.
3mm thick sheet glass, ordinary quality and glazing with oil putty/ wooden beads in square pane not exc 0.50 Sqm each pane in wooden/ Steel windows complete all as specified and directed.
Small fittings of 2nd class hard wood (SAL) such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including 50mm long, medium weight, cold rolled mild steel butt hinge, articles not exc. 200 cu.cm. each including preparation of articles and applying two coats of synthetic enamel paint over a coat of pink primer, all as specified.
Aluminium anodised, barrel tower bolts of size 200mm extruded section and fixed all as specified & directed.
Aluminum long handle, cast type anodised of size 150 mm complete all as specified and directed.
Mild steel prepainted sheet type door spring, heavy duty, 200mm long including roller and roller plate, all as specified.
Aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt 250 mm long, all as specified and directed.
Applying two coats of synthetic enamel paint over a coat of pink primer on new wood or wood based surfaces of any description, exc. 10cm width or girth including preparation of surfaces, all as specified.
Preparation of new steel and iron surfaces of any description over 10 CM width or girth and applying two coats of synthetic enamel paint , complete all as specified and directed.
Machine cut kota stone slab flooring 18-20 mm thick of size not less than 550 mm X 550 mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 15mm screed layer in cement mortar 1:6 (1 cement : 6 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified. Note:- PCC sub base if provided shall be measured and paid under respective Items of BOQ.
Machine cut kota stone slab 18-20 mm thick as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab as in in skirting, dados, risers to steps etc, laid over and including 10 mm screed layer in cement mortar 1:4 (1 cement : 4 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish complete, all as specified.
Green marble work 18 mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match, laid over and including 15mm screed layer in cement mortar 1:6 (1 cement : 6 coarse sand), cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified. Note:- PCC sub base if provided, shall be measured and paid under respective Items of BOQ.
Mat finish (non skid), Premium class I grade, coloured, joint free (edge cut) ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, in floors and the like, set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 15mm thick screed bedding layer in cement mortar 1:6 (1 cement : 6 coarse sand) complete, all as specified.
Mat finish (non skid), Premium class I grade, coloured, joint free (edge cut) ceramic tiles, 7 to 8mm thick (Square/ rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 Sqm, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed.
Glazed ceramic, premium quality, joint free (edge cut) coloured/ printed tiles 450mm x 350mm/ 350mm x 250mm x 7 to 8 mm thick on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting n. exc 10 cms girth in brick wall complete, all as specified.
Mild steel galvanised iron tubings (ISI Marked) 15mm dia medium grade with all fittings & fixtures complete to walls/ ceilings or laid in floors all as specified and directed.
All as per item no 61 above above but except GI tubing , complete all as specified. Note:- Servicable pipe retreived under respective Item of BOQ shall be used.
Mild steel galvanised iron tubings (ISI Marked) 20mm dia medium grade with all fittings & fixtures complete to walls/ ceilings or laid in floors all as specified and directed.
All as per item no 63 above but except GI tubing , complete all as specified. Note:- Servicable pipe retreived under respective Item of BOQ shall be used.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in tranches of bore 110mm complete, all as specified.
PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in tranches of bore 75mm complete, all as specified. Note for Serial Item No 65 & 66:- Excavation and earth work shall be measured and pai under respective Items of BOQ.
PVC (SWR) junction single, (Single T) equal or unequal, 75mm bore, provided with oval access door all as specified.
PVC (SWR) junction single, (Single T) equal or unequal, 110mm bore, provided with oval access door all as specified.
PVC (SWR) bend any radius, 75mm bore, complete all as specified.
PVC (SWR) bend any radius, 110mm bore, complete all as specified.
HDPE pipe 40 mm dia of pressure rating 6kg/ Sqcm fixed to walls, oulet of sinks or laid in floors, fixed in repairs all as specified.
PVC (SWR) floor trap, plain with grating including jointing with solvent cement, dia of outlet 75 mm, fixed in repairs all as specified and directed.
Grating square 150 mm size of PTMT (Minimum weight 100gms), fixed in repairs, all as specified.
40 mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed in repairs, all as specified and directed.
Steel plate rack made of stainless steel having thickness 0.80 mm, fixed with plugs, washers and steel screws including bedding in cement mortar on to dwarf wall, overall size 600mm x 750mm X 250 mm, all as specified and directed.
Sink with drainage board made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to one brick/ dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm bowl size 405mm x 355mm x 178 mm, fixed in repairs, all as specified. Make:- (Cat Part No BSSBSD-52 of make 'Blue Star or equivalent in makes mentioned in Appendix 'C').
Wash basins, Vitreous China (Flat white type) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including Pillar taps, 15mm bore cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, complete all as specified. Make: Cat Part No. 1008 of Cera or equivalent in makes mentioned in Appx 'C'
Soap dish, chromium plated, fixed to plugs with chromium plated, brass screws, fixed in repairs all as specified. Make: Makes as mentioned in Appx 'C'
Stop valves/ angle valve, cast copper alloy, chromium plated, fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed in repairs complete, all as specified.
Stop valves, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down ,high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed in repairs complete, all as specified. Make:- Makes as mentioned in Appendix 'C').
Bib taps, 15mm bore, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down high pressure, screwed for iron pipe or for brass ferrule fixed in repairs, all as specified. (Make as per Appendix 'C').
Mild steel curtain rod, 25 mm bore, powder coated with all fittings i.e. wall bracket, bracket screws, stope and rollers, fixed in repairs all as specified.
Brass chromium plated tubular towel rail 20 mm dia, "D" type, 60 cms long between flanges fixed in repairs with and including chromium plated brass brackets, brass screws complete all as specified
Supply only integral water proofing compound, complete all as specified.
Rotational moulded polyethylene water storage tank 500 Ltrs capacity four layered (ISI Marked) cylinderical vertical with closed top, hoisted and fixed in position with ball brass valve, high pressure with PVC float valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line including taking down of old tank, all as specified.
Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer), mixed with water proofing compound @ 3% by weight of cement on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. ( Note : WPC will be measured and paid separately under respective Item of BOQ)
Rendering cement plaster 15 mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer), on other than fair faces of brick wall or on stone masonry surfaces, trowelled to even and smooth finish without using extra cement complete all as specified.
Two coats of white wash on on newly plastered or un plastered, previously undecorated surfaces of ceiling or facia including preparation of surfaces complete, all as specified.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over 2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
Prepration of old treated surfaces of walls by removing existing treatment by scarping, brushing etc including making surface clean , dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and filling holes, dents, cracks with mixture of white cement and mortar and applying two coats of oil bound distemper over a coat of primer over 2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed.
Applying two coats of cement base paint on newly plastered or previously undecorated wall surfaces with alkali resistant priming coat including preparation of surface, tint and shade as approved by Engr-in-Charge.
Prepration of old treated surfaces of walls by removing existing treatment by scarping, brushing etc including making surface clean , dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and filling holes, dents, cracks with mixture of white cement and mortar and two coats of cement base paint on newly plastered or previously undecorated wall surfaces with alkali resistant priming coat including preparation of surface, tint and shade as approved by Engr-in-Charge.
Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly and cost of same shall be deemed to be included in unit rate quoted by bidder.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC conduit not less than 20mm dia, medium grade with IS 9537 (Part-III) 1983 marking with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly and including pressed steel terminal boxes made out of 1.20 mm thick mild steel sheet duly painted with one coat of red oxide primer for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete including making good disturbed surfaces to match with existing all as specified and directed.
All as per serial item No '95' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '95' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
All as per serial item No. '95' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Switch piano flush type, single pole, one way, 5 Amps, all as specified.
Switch socket combination two in one, 5 amps flush type, all as specified.
Switch socket combination two in one, 3 Pin 5 amps and 15 amps, flush type, all as specified.
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
Lamp holder, PVC/ Polycarbonate type with back plate suitable for angular/ batten fittings, all as specified.
LED lamps, 10 watts all as specified and directed. Make:- CAT Part No LHLDERUEML8X010 of make "Havells" or equivalent in makes mentioned in Appendix "C".
Flush type, step fan speed controller suitable for 1200/ 1400 mm sweep ceiling fan complete all as specified and directed.
Renewal of sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 6 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 4 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 6 sqmm copper conductor and one RM of earth wire of 4 Sqmm, shall be measured as one RM).
E-lite LED Triyca batten, colour changing LED batten with options of 3000K, 4000K & 6500K all in one fixture, 20 Watts complete with all accessories and fixtures prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete. Make : Havell's Cat Part No. LHEXBXPNIN1W020 or equivalent in makes mentioned in Appx 'C'.
Pluto Neo Panel 2 feet X 2 feet, 42 Watt, environment friendly, new generation, aesthetically, ultra modern recess mounting luminaire with high brightness SMD LED's as light source complete with all accessories and fixtures prewired and making connection with 3 core copper flexible cable of size 23 x .0076 from ceiling rose/ PVC connector to light complete fixed in armstrong/ grid ceiling. Make : Havell's Cat Part No. PLUTONEO2X2PLR42WLED8575 or equivalent in makes mentioned in Appx 'C'.
Taking down ceiling/ exhaust fan of 1200/ 1400/ 250/ 300 mm sweep from fan hook dismentling blade opening of motor cleaning stator rotor, cleaning of all parts, greasing, oiling of bush & bearing, reassembling including replaecement of unserviceable parts complete, refixing, reconnecting with 3 core copper cable of size 23/0.0076 from ceiling rose to ceiling fan and testing on completion, complete all as specified.
Removal of existing burnt winding of ceiling fan, cleaning the slots thoroughly with suitable cleaning agent, applying slot insulation and rewinding with new super enameled insulated 30 to 38 SWG copper wire of appropriate size including all winding, insulating material and impregnation of insulating varnish of any make, type, model, applying air drying the winding thoroughly complete, all as specified and directed.
Roadway lighting luminaire, LED street light 35 watts, IP-66 having aluminium housing with toughned glass on 9.00 metres poles/ walls. LED should be mounted on MCPCB and should be fixed to the body with proper thermal conductive paste to ensure quick heat transfer of heat to heat sink. This ensure the LED assembly free from dust/ moisture/ water entry (IP-66). The operating voltage should be from 90V to 300V with under voltage and over voltage protection. The luminaire should be connected aluminium pvc insulated wire 2 sqmm as required at site and connecting the same to the cable with the help of the connector all as specfied and directed. Make:- Havell's Cat Part No ENDURACITYLITEPLAT PLUSSL35W LED757SASYBOPC or equivalent in makes mentioned in Appendix 'C'. Note:- Contractor shall provide following certificates:- (i) IP-66 as per IS/ IEC60529-2001 with test certificate. (ii) THD˂15% with test certificate. (iii) Warranty upto two years.
Renewal of sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar, all as specified. Make : Havells Cat Part No. DHDPSHODPW08 or equivalent in makes mentioned in Appx 'C'.
Sheet metal enclosures for DBs when MCBs to be used, triple pole and neutral, 4 way, 415 volts with 200 Amp rated bus bar, double door all as specified. Make : Havells Cat Part No. DHDPTHODRW04 or equivalent in makes mentioned in Appx 'C'.
MCB SP 6 to 32 Amps, 240 Volts, 10 kA all as specified. Make : Indo Asian Cat Part No. 811122 to 811128 or equivalent makes mentioned in Appx 'C'.
MCB SPN 6 to 32 Amps, 240 Volts, 10 kA all as specified. Make : Indo Asian Cat Part No. 811144 to 811151 or equivalent makes mentioned in Appx 'C'.
MCB TPN 63 Amps, 415 Volts, 10 kA all as specified. Make : Indo Asian Cat Part No. 811359 or equivalent makes mentioned in Appx 'C'.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc including testing complete and taking out old unservicable cable all as specified. Note:- Excavation & Earth work, cable cover, GI tubing and sand cushioning shall be measured and paid separetly.
Mild steel galvanised iron tubing light grade for cable protection in crossing drain of 40mm size. Make of GI tubing:- Makes as mentioned in Appendix 'C'.
Excavation in trenches for pipes, cables and manholes in any type of soil n.exc 1.5m wide and but exc 1.5m deep and getting out complete all as specified and directed.
Returning filling in (soil) including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any type of soil complete all as specified and directed.
Removal of excavated material (soil) to a distance n.exc 50 metres and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick cover of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
M/S CHOWDHARY CONSTRUCTION COMPANY
jatindera enterprises
MM Constructions
Pardeep Furnishers and Interiors
m/s saurabh mahajan
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .