Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹12.2 L+₹77,777.19 (6.83%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹6.9 L
EMD Value
₹14,000
Closing Date
16 Jun 2020, 6:00 pmClosed
GARRISON ENGINEER BANAR
GARRISON ENGINEER BANAR, JODHPUR-342027
COMPLETION OF INCOMPLETE WORK FOR PERIODICAL SERVICES TO MAP JCOS AND OR ACCN AND PROVN OF STORAGE SHED OF ABOD AND SPECIAL REPAIR TO BLDG NO P229 AND P230 AT BANAR AGAINST RISK COST OF CA NO GE/BNR-03 OF 2017-18 AND GE/BNR-37 OF 17-18
2019_MES_308687_3
8819/29/E8
Open Tender
Civil Works
Works
180 days
BANAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER BANAR
₹14,000
Yes
10 Aug 2020
26 May 2020
18 Jun 2020
26 May 2020
16 Jun 2020
2 Jun 2020
Amount
PERIODICAL SERVICES FOR MAP, MD JCOs AND OR ACCN AT AA BANAR
Preparation of old decorated surfaces of walls (plastered of unplastered) including cornices, pillasters etc by brooming down or wire brushing removing dust, dirt etc scrapping smoke, scot, moulds, moss and efflorecent salts, removing oil and greasy spots etc and applying two coat of cement base paint, white or tinted complete all as specified and directed by Engineer-in-charge.
Material and labour for 15 mm thick rendering in cement morter 1:4 on stone masonry surfaces with using integral water proofing compound, finished even and smooth without using extra cement including taking down existing plaster complete all as specified and directed by Engineer-in-charge. Note:- Integral water proofing compound shall be measured and paid separately under supply only item.
Supply only integral water proofing compound.
Material and labour for preparation of newly plastered or unplastered surfaces of walls and applying two coats of cement base paint white or tinted over a coat of white wash on walls complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint of any tint complete all as specified and directed by Engineer-in-charge.
PROVN OF STORAGE SHED OF ABOD AND SPECIAL REPAIRS TO BLDG NO P-229 AND P-230 (OR SINGLE ACCN) AT AA BANAR
SCHEDULE 'A' (B/R PORTION)
Material and labour for water proofing treatment of non accessible roof, 10mm thick rendering in CM 1:3 on roof surfaces finishes even and fair w/o using extra cement mixing with and including water proofing compound @ 3% of wt of cement and applying water proofing treatment on roof surfaces as under :- (a) First course:- one coat of bitumen primer T-10/ polymerised confirming to IS-3384 @ 0.30 ltr/sqm (b) Second course :- One coat of bonding material using blown type bitumen confirming to IS-702 grade 85/25 @ 1.2 Kg/Sqm (c) Third Course : - A Layer of App modified polymeric membrane. center core of 100 micron HMHDPE, outer film 20 micron each, thickness 3mm having weight 3 kg/sqm (d) Fourth Course :- Onecoat of bonding material using blown type bitumen conforming to IS 702 grade 85/25 @ 1.2 Kg/Sqm complete all as specified and directed by Engineer in charge . NOTE - The laying of membrane shall got executed by nominated applicator of manufacturer.
Material and labour for hard core of stone boulders for plinth protection complete all as specified and directed by Engineer-in-charge.
Material and labour for 50mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in plinth protection, concrete shall be laid in alternate bays n.exc. 3m in length, finished fair and even complete all as specified and directed by Engineer-in-charge.
Three coat of white wash on ceiling including preparation of surfaces complete all as specified and directed by Engineer-in-charge.
Material and labour for applying two coats of oil emulsion distemper over a priming coat with alkali resistant priming paint on new plastered surfaces of wall including preparation of surfaces with JK/Birla wall putty complete all as specified and directed by Engineer-in-charge.
Material and labour for applying two coats of cement base paint including preparation of surface complete all as specified and directed by Engineer-in-charge.
Supply and fixing 35 thick factory made, 2nd class hard wood, plain framed, panelled shutters (any Nos of panels) with lock rail and panel of 9mm BWP Commercial ply as spfd in particular specifications or 12mm veneered particle board with commercial veneering on both sides faces. The size of rail and styles shall be as per SSR, Kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-charge.
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor 150mm size complete all as specified and directed by Engineer-in-charge.
Supply and fixing 150 mm long mild steel barrel tower bolts stove enameled black with bright bolt complete all as specified and directed by Engineer-in-charge.
Supply and fixing 300mm long mild steel sliding door bolts plate type, stove enameled black with bright bolt not less than 16mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed by Engineer-in-charge.
Supply and fixing 150 mm long mild steel pressed handles, oval type, stove enameled black complete all as specified and directed by Engineer-in-charge.
Two coat of synthetic enamel paint over one coat of Red Oxide primer on steel surfaces complete all as specified and directed by Engineer-in-charge.
Two coat of synthetic enamel paint over one coat of pink primer wooden surfaces complete all as specified and directed by Engineer-in-charge.
4mm thick plain sheet Glass ordinery quality and Glazing with oil putty n.exc. 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-charge.
SCHEDULE 'A' (E/M PORTION)
Material and labour for point wiring complete with 1.5 sqmm single core mulfistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade fixed on and including PVC casing caping fixed on wall surfaces, ceiling etc including 3mm thick, laminated Hylem sheet for mounting switches sockets regulators etc on cast iron terninal boxes with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly for:-
One light/Exhaust fan/Ceiling fan point contolled by one, oneway switche single pole.
One 3 pin, 5 Amp socket outlet on same board.
One 3 pin, 5 Amp socket outlet on independent board.
Supply and fixing ceiling rose surface backelite 65x50mm three terminals complete all as specified and directed by Engineer-in-charge.
Supply and fixing fan regulator electronic type for ceiling fan 1200 mm sweep complete all as specified and directed by Engineer-in-charge.
Supply and fixing multipurpose socket outlet with piano flush type 3 pin 5 Amp complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch Piano flush type 5 Amp single pole complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch socket combination 2 in1, 5 A flush type complete all as specified and directed by Engineer-in-charge.
Supply and Fixing LED based tube rode & fitting 1x16Watt box type complete with LED tube and all accessories complete all as specified and directed by Engineer-in-charge. Make:-CG Cat part No-DMLN1LT8-16 and Cat Part No LCCLB-16-CDL or equivalent model of make Wipro/Philips/Havells.
Material and labour for replacement of existing u/s any type and make security lights fitting and Supply and fix on pole/wall LED based street light fitting having IP 66 protection class with the apoxy powder coated housing inclose with glass cover in frame, 45W mounted on MCPCB suitable for 50mm outer dia pipe and minimum luminious efficency of 90 lumens/W and the matrix of Leds having a minimum out put of 40 W and capable of producing a constn & lux in the voltage range of 180 V to 280 V at 50Hz and suitable for operation in a temprcture range of 5°C to 50°C RH range of 10°% to 90% and injection temp not grater tha 80°C including mounting the LED light fitting on a 50mm dia GI pipe bent to shape and material and lobour for connecting the light fittings to Junction box to brackets using twin core multi stranded flat weather proof aluminium of size 4 sqmm duly passed through the brackets through holls drilled for entry and exits of the cable so as to concealed the same. Make : Bajaj ordering product code 169681-BRTFG-45W LED
Supply and fixing factory made sheet metal enclosure distribution board double door IP-42 protection SPN 8 way 240 Volts complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB 10 KA rupturing cap ISI marked 'C' series
MCB SPN 32/40 Amps
MCB SP 5 to 32 Amps
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 16 sqmm 2 core nominal cross section in service connections complete all as specified and directed by Engineer-in-charge.
Material and labour for GI pipe light grade 40mm dia for cable protection with suitable bracing clamps on wall/pole including cold drilling and making good surface complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Ceiling Fan, 1200mm sweep complete all as specified and directed by Engineer-in-charge. Make : Bajaj/ USHA
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including provision of 40 mm dia light grade pipe & watering pipe shall be 20 mm bore meadium grade including all excavation & earth work in any type of soil incl PCC for pit (1:3:6) type C-1 with RCC cover in PCC(1:2:4) including chrcoal , salt funnel GI pipe 40 mm dia light grade up to to 7.5 mtr length ,all as directed at site. NOTE:- Rate included for excavation & earth work in any type of strata as shown in electrical plate No 3 earth work & protection pipe upto 7.5 mtr. any variation above shall be adjusted through respective item of this schedule.
D DEV COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .