| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 CrAccepted-Finance | ₹17.5 Cr | L1 | Accepted-Finance Based on L1 basis |
| 2 | L2₹18.1 CrRejected-Finance | ₹18.1 Cr | L2 | Rejected-Finance Based on L1 basis |
| 3 | L3₹18.5 CrRejected-Finance 112 KALIAMMAN KOIL STREET NATESAN NAGAR VIRUGAMBAKKAM CHENNAI 600092 | CHENNAI | TAMIL NADU | 600092 | ₹18.5 Cr | L3 | Rejected-Finance Based on L1 basis |
Tender Value
₹19.7 Cr
EMD Value
₹29.7 L
Closing Date
31 Jan 2023, 3:00 pmClosed
Executive Engineer
O/o Executive Engineer, WRD, WD VI Bicholim
Construction of 15 MLD Raw Water Pumping Station for WTP at Morlem Rehabilitation colony to supply drinkin water to vp Querim, Poriem, Morlem, Pissurlem, Honda and Bhironda in Sattari Taluka
2023_WRD_6521_1
No.WRD/WDVI /Accts/ F.17/2022-23/TN-e-25
Open Tender
Civil Works - Water Works
300 days
Bicholim
Please refer Tender documents.
5 documents required · 5 mandatory
₹30,000
₹29.7 L
O/o SE I, WRD, Porvorim Goa
10 Mar 2023
4 Jan 2023
3 Feb 2023
4 Jan 2023
31 Jan 2023
26 Jan 2023
25 Jan 2023
Amount
Sub Estimate1 :- Construction of Jack well cum pump house
Earthwork in excavation by mechanical/manual means in all types of strata comprising any of materials such as soil, silt clay gravel murrum of all varities shingles, pebbles all types of conglomerates , laterite rock, soft rock, ordinary rock, disintegrated rock, weathered rock fissured, shattered/decomposed rock and all such other materials either in full or in parts as the case may be adopting any approved method or methods as may be convenient or permitted inclusive of chiseling wedging etc but blasting prohibited in all condition such as dry, moist, saturated submerged foul conditions etc. including pumping or bailing out water , dewatering including setting out construction of shoring , strutting and bracing removal of stumps and other deleterious matter , dressing of sides and bottom , providing barricading, danger lighting, guarding and back filling the excavation earth to the extent required and disposal of excavated soil rock in specified areas with all leads and lifts etc. and as per specification and drawing and as directed by the Engineer-in charge etc. all complete.
Rubble packing with hard laterite stones under floors including watering ramming and consolidating etc. In pipeline trenches and other foundation complete and dewatering the trenches and bailing out water including removal of slush mud etc. for any depth and disposal of pumped mud, water , slush to suitable point not forming circuit of return of pumped water to the very trench by employing diesel generated pump.
Centering and shuttering including strutting propping etc. And removal of formwork for : a). Foundation , footings , bases of columns and mass concrete etc.
Providing and laying cement concrete 1:2:4 ( 1 cement:2 coarse sand :4 graded granitic or basaltic stone aggregate 20mm nominal size) excluding cost of centering and shuttering in : a). All work upto plinth level
Providing and laying in position ready mixed concrete (RMC) High Performance Cement per MORTH Clause 1715 manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended proportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per the directions of the engineering- charge. All works upto floor V level v). M-30 grade concrete
Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10 kilometers distance having continuous agitated mixer, manufactured as per the mix design of M- 30( by using 410kg of cement per Cu.m of concrete in Ground level reservoir) for reinforced cement concrete work including the cost of pumping the R.M.C from transit mixer to the site of laying, excluding the cost of reinforcement ,including the cost of centering shuttering for R.C.C work, including rendering in cement mortar of 1:3 in 6mm thickness for all external R.C.C surfaces, and 12mm cement mortar of 1:3 for internal surfaces, in caring including the cost of successful water tightness test as per IS code with relevant latest amendments complete in all respects in Ground level reservoir as per the direction of the Engineer-in-charge a) Bottom slab of GLR Including Haunch portion
Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10 kilometers distance having continuous agitated mixer, manufactured as per the mix design of M- 30 ( by using 410kg of cement per Cu.m of concrete in Ground level reservoir)for reinforced cement concrete work including the cost of pumping the R.M.C from transit mixer to the site of laying excluding the cost of reinforcement ,including the cost of centering shuttering for R.C.C work, including construction of working platforms with staging, at suitable heights for the construction of the ground reservoir for a height of 6 meter with bellies, bamboos, planks rafters, and allied components, including rendering in cement mortar of 1:3 in 6mm thickness for all external R.C.C. surfaces of reservoir, including the cost of plastering in cement mortar in 1:3 in 12 mm thickness for all internal surfaces of reservoir (with mechanical machine mixer for plaster) including the cost of successful water tightness test as per IS code with relevant latest amendments complete in all respect in Ground level reservoir as per the direction of the Engineer-in-charge a).From ground level upto 5m height in walls
Providing and laying in position ready mixed concrete manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10 kilometers distance having continuous agitated mixer, manufactured as per the mix design of M- 30 ( by using 410kg of cement per Cu.m of concrete in Ground level reservoir)for reinforced cement concrete work including the cost of pumping the R.M.C from transit mixer to the site of laying excluding the cost of reinforcement ,including the cost of centering shuttering for R.C.C work, including construction of working platforms with staging, at suitable heights for the construction of the ground reservoir for a height of 6 meter with bellies, bamboos, planks rafters, and allied components, including rendering in cement mortar of 1:3 in 6mm thickness for all external R.C.C. surfaces of reservoir, including the cost of plastering in cement mortar in 1:3 in 12 mm thickness for all internal surfaces of reservoir (with mechanical machine mixer for plaster) including the cost of successful water tightness test as per IS code with relevant latest amendments complete in all respect in Ground level reservoir as per the direction of the Engineer-in-charge b). Wall More than 5m upto 6.5m including ring beam
Providing Corrosion resistant steel CRS-50 bars of (SAIL,TATA, VIZAG,JSW Steel Ltd.)(Conforming to IS 1786 of 1985) for R.C.C. work including bending, binding & placing in position with factory made precast concrete cover blocks of strength more than M-30 for maintaining the required clear cover for R.C.C structures in all the floors complete as per the direction of the Engineer- in -charge
Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in cm. 1 : 5 (1 cement : 5coarse sand) in foundation upto plinth level (Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
Finishing fine with neeru over plaster
Providing and fixing anodized aluminum sliding windows with two sliding shutters 20 mm sections and 5 mm clear float glass.
Supplying and fixing rolling shutters of approved make, made of 80 x 1.25 mm M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of 1.25mm thick for falling shutter stop cover and spring.
Extra for providing mechanical device, chain and crank operation for operating rolling shutters.- b). Exceeding 16.80 sq.m. in area Chain & overhead operation
Providing and fixing in position S.S. hand rail in main stair case, and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials, etc. complete.
Providing and fixing vitrified antiskid tiles (320x320) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete.
Painting three or more coats with acrylic exterior paint of approved brand and manufacture (Such as Dulex/ Asian Paints/Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete.
Distempering two or more coats with oil bound washable distemper of approved brand and manufacture and of required shade on new work over and including a priming coat with distemper primer of approved brand and manufacture to give an even shade.
Providing , erecting and commissioning Single Girder Hand Operated Circular / Rectangular Travelling Crane with 6 m lift complete with chain pulley block ISI marked and travelling trolley both tested for 50 % overload including arrangement for longitudinal travel / circular travel and cross travel with wheel, hand chain, etc complete.- 7.5 Ton capacity
Sub Estimate 2 :- Providing and laying Connecting Main 800mm dia DI K9 pipe.
Supplying at store or site of work including railway freight, carting, loading and unloading, stacking etc. Centrifugally cast, (spun) ductile iron pressure pipes (with socket/spigot ends) conforming to IS : 8329-2000 with cement mortar lining inside the pipe and outside zinc coat as per IS : 8329-2000 with up to date amendments suitable for jointing with rubber gasket known as TYTON joints. Class K-9 . Nominal Diameter in mm ……………. (m). 800
Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete. IV). Flanged Socket Nominal dia. in MM n). 800
Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. C.I. Sluice Valve confirming to I.S. 14846-2000 & bearing ISI mark double flanged with CAP TYPE P.N. 1.00(Class B) mominal Dia in MM 750mm
Earthwork in excavation by mechanical /manual means in all types of strata comprising any of materials such as soil, silt clay gravel murrum of all varities shingles, pebbles all types of conglomerates , laterite rock, soft rock, ordinary rock, disintegrated rock, weathered rock fissured, shattered/decomposed rock and all such other materials either in full or inparts as the case may be adopting any approved method or methods as may be convenient or permitted inclusive of chiseling wedging etc but blasting prohibited in all condition such as dry, moist, saturated submerged foul conditions etc. including pumping or bailing out water , dewatering including setting out construction of shoring , strutting and bracing removal of stumps and other deleterious matter , dressing of sides and bottom , providing barricading, danger lighting, guarding and back filling the excavation earth to the extent required and disposal of excavated soil rock in specified areas with all leads and lifts etc. and as per specification and drawing and as directed by the Engineer-in charge etc. all complete b). Hard rock where blasting prohibited
Jointing of C.I/D.I pipes and specials with rubber gaskets (TYTON joints) EPDM type including cleaning the socket and spigot ends with kerosene oil/below lamp and applying soft soap to socket and spigot ends before inserting for rubber gasket jacking and fixing in proper condition including cost of rubber gasket, oil, soft soap and hydraulic testing of jointing as per IS:3144-1985. Nominal Diameter in mm o). 800
Hoisting laying cast iron sluice valves/butterfly valves/reflux valve of size given below at location in pipeline etc .complete as directed as per IS:2685-1971 CLASS II & III. Sluice Valves (Dia in mm) 750mm
Sub Estimate 3 :- Providing and laying Rising Main 450mm dia DI K9 pipe
Supplying at store or site of work including railway freight, carting, loading and unloading, stacking etc. Centrifugally cast, (spun) ductile iron pressure pipes (with socket/spigot ends) conforming to IS : 8329-2000 with cement mortar lining inside the pipe and outside zinc coat as per IS : 8329-2000 with up to date amendments suitable for jointing with rubber gasket known as TYTON joints. Class K-9 . Nominal Diameter in mm ……………. (i). 450
Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete. All socket Tee Nominal dia in MM s1. 450x450
Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete Flanged Socket Nominal dia. in MM n). 450
Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete Double socket bend 90 degree Nominal dia. in MM i). 450
Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete Double socket bend 45 degree Nominal dia. in MM i). 450
Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete Double socket bend 22.50 degree Nominal dia. in MM i). 450
Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete Double socket bend 11.25 degree Nominal dia. in MM i). 450
Supply at store or site of work including railway freight, carting, loading, unloading, stacking etc. Ductile Iron pipe specials including rubber ring fitting push on joints conforming to IS : 9523 with inside cement mortar lining & externally coated with zinc with finishing layer of bituminous paint complete All flanged Tee Nominal dia. in MM 45). 450X450
Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. C.I. Sluice Valve confirming to I.S. 14846-2000 & bearing ISI mark double flanged with CAP TYPE P.N. 1.00(Class B) Nominal dia. in MM j). 450mm
Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. C. I. Butterfly (tight shut off) valve with cast iron body conforming IS:210 FIG. 260 and disc shafts seal rings, clamping ring, nitrite rubber seal leaded bronze bearings manually operated complete conforming to BS:5155/IS:13095 etc complete. TYPE P.N. 1.0 (Class B). Nominal dia. in MM j) 500
Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. cast iron Air valve kinetic double orifice type combined with screw - down isolating valve, small orifice elastic ball resting on a gunmetal orifice nipple, large orifice vulcanite ball seating on moulded seat ring, inlet faced and drilled to IS:14845 Table 4 & 6 . Valves suitable for a maximum working pressure of 10kg/cm2 generally conforming to G & K, Fig H - 40. TYPE P.N. 1.0 (Class A). dia. in mm b). 50
Providing and laying C.I. Right angled type spring loaded single seat pressure relief valve similar to Glen field H 19 having valve and seat gun metal bushes in cover stay rods of forged mild steel spring of best quality square section cast iron bend, wheel for adjustment with necessary pointer and index. (Class B) . dia . in mm e). 200
Earthwork in excavation by mechanical/manual means in all types of strata comprising any of materials such as soil, silt clay gravel murrum of all varities shingles, pebbles all types of conglomerates , laterite rock, soft rock, ordinary rock, disintegrated rock, weathered rock fissured, shattered/decomposed rock and all such other materials either in full or in parts as the case may be adopting any approved method or methods as may be convenient or permitted inclusive of chiseling wedging etc but blasting prohibited in all condition such as dry, moist, saturated submerged foul conditions etc. including pumping or bailing out water , dewatering including setting out construction of shoring , strutting and bracing removal of stumps and other deleterious matter , dressing of sides and bottom , providing barricading, danger lighting, guarding and back filling the excavation earth to the extent required and disposal of excavated soil rock in specified areas with all leads and lifts etc. and as per specification and drawing and as directed by the Engineer-in charge etc. all complete
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a). All works up to plinth level
Centering and shuttering including strutting, propping etc. and removal of formwork for : i). Foundations, footings, bases for columns and mass concrete.
Providing & laying cement concrete 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded granitic or basaltic stone aggregate. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a). All works up to plinth level
Providing High yield strength steel reinforcement bar (HYSD)/TMT steel reinforcement bar from secondary producers (Confirming to IS 1786 of 1986) for RCC work including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
Supplying at store or site of work including railway freight, carting, loading, unloading, stacking etc. Cast Steel single door swing check type Reflux (non return) valve having body bonnet in graded cast steel i.e. ASTM A 216 Gr WCB faced with 13% cr steel. Hinge pin in stainless steel ASTM A 479 type 410, cover stud in alloy steel ASTMA 193 Gr B 7, Gasket in metallic spiral wound AISI 304 with graphite in the construction and testing of the valves will be as per BS 1868 & BS 6755 part I respectively. Flanged ends without bypass arrangements flanges drilled to IS 1538 table 4&6 or ANSI B 16.50 as per the requirement. Class 300 (Class A). Dia. in MM j). 450
Making joints to D.I/ C.I pipes with mechanical joints by nut bolts rubber rings that are provided with the joints, for push on tight joints including the cost of work force, tools, hydraulic testing of joints etc complete as per the direction of the engineer in charge. I Double socketed specials such as bends, collar couplings etc. Nominal dia. in MM j). 450mm
Jointing of C.I/D.I pipes and specials with rubber gaskets (TYTON joints) EPDM type including cleaning the socket and spigot ends with kerosene oil/below lamp and applying soft soap to socket and spigot ends before inserting for rubber gasket jacking and fixing in proper condition including cost of rubber gasket, oil, soft soap and hydraulic testing of jointing as per IS:3144-1985. Nominal Diameter in mm j). 450
Hoisting laying cast iron sluice valves/butterfly valves/reflux valve of size given below at location in pipeline etc .complete as directed as per IS:2685-1971 CLASS II & III. Nominal dia. in MM c). 450mm
Fixing C.I. Double orifice / Kinetic type air valve of following sizes with bronze ferrule at inlet screwed on isolating valve small orifice elastic ball resting valve small orifice elastic ball resting on small bronze orifice nipple and large orifice vulcanite ball resting on moulded seat ring inlet faced and drilled to BST "D" suitable to working pressure of 10 kg/sq. cm. Nominal dia. in MM a). 50mm
Construction of masonry chamber 120x120x100 cm inside in 40kg/sq. cm brickwork complete with 23 cms wall thickness and in cement mortar1:4 ( 1 cement : 4 coarse sand) for sluice valve size beyond 200mm dia with necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 coarse sand: 10 graded stone ballast 40 mm nominal size) and inside plastered with CM 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement complete and chamber cover as specified below etc. all complete as per standard drawing . (rate is inclusive of rate earthwork excavation, cost of surface cover and all other materials and labour as per details below) (Size 120x120x100) c). with C.I. cover and frame 600mm x600mm weighing not less than 250 Kgs in 120 mm thick RCC slab cover in cement concrete 1:2:4 ( 1 cement: 2 coarse sand : 4 graded stone ballast 20 mm nominal size)
Sub Estimate 4:- Construction of R.C.C Collection/Delivery tank.
Earthwork in excavation by mechanical means (hydraulic excavator)/manual means in foundation pipeline trenches drains ( not exceeding 1.5 m in width or 10 sq.m on plan) including dressing of sides & ramming of bottoms lift upto 1.5m including getting out the excavated Soil & disposal of surplus excavated Soil as directed within a lead of 50m.in : All kinds of soil
Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete
Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: a ). All works upto plinth level
Centering & shuttering including Strutting, Propping & removal of forms for : ( I ). Foundations, Footings, Bases for columns
Centering & shuttering including Strutting, Propping & removal of forms for : ( ii ). Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like
Centering & shuttering including Strutting, Propping & removal of forms for : ( xiii ). Suspended floors, roofs landings, shelves & their supports
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) (a). All works upto plinth level
Providing and laying in position (1:11/2:3) Reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) ( c ). In beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases upto floor five level
Providing and laying in position ready mixed concrete (RMC) with usage of Ordinary Portland Cement manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended proportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per the directions of the engineering-charge. All works upto floor V level iv). M-30 grade of concrete
Providing TMT steel reinforcement bars of (SAIL, TATA. VIZAG, JSW Steel Ltd.) (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member
Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge
6mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand)
12mm cement plaster 1:4 (1 cement : 4 fine sand)
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
Neat Cement punning
Painting three or more coats with acrylic exterior paint of approved brand and manufacture (Such as Dulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete.
Extra for providing and mixing water proofing material proportion recommended by the manufacturers. a). 12mm cement plaster 1: 3 (1 cement : 3 sand)
Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1 cement : 4 coarse sand) in foundation and basement.
Kotah stone slab flooring over 20 mm (average) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) ( a ). 20 mm thick.
Sub Estimate 5 :- Construction of Compound wall for delivery tank.
Earthwork in excavation by mechanical/manual means in all types of strata comprising any of materials such as soil, silt clay gravel murrum of all varities shingles, pebbles all types of conglomerates , laterite rock, soft rock, ordinary rock, disintegrated rock, weathered rock fissured, shattered/decomposed rock and all such other materials either in full or in parts as the case may be adopting any approved method or methods as may be convenient or permitted inclusive of chiseling wedging etc but blasting prohibited in all condition such as dry, moist, saturated submerged foul conditions etc. including pumping or bailing out water , dewatering including setting out construction of shoring , strutting and bracing removal of stumps and other deleterious matter , dressing of sides and bottom , providing barricading, danger lighting, guarding and back filling the excavation earth to the extent required and disposal of excavated soil rock in specified areas with all leads and lifts etc. and as per specification and drawing and as directed by the Engineer-in charge etc. all complete
Providing and laying in position ready mixed concrete (RMC) with usage of Ordinary Portland Cement manufactured in fully automatic batching plant and transported to site of work in transit mixer for a lead upto 10kms having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C., from the transit mixer to the site of laying, excluding the cost of centering, shuttering, finishing and reinforcement including the cost of admixtures in recommended proportions as per IS : 9103 to accelerate/retard setting of concrete, improve workability without impairing strength and durability as per the directions of the engineering – in - charge. All works upto floor V level. v). M-30grade concrete
Laterite masonry in neatly dressed stones for 20cms thick masonry walls in cm. 1:4 (1cement:4 coarse sand) in foundation up to plinth level.
Laterite masonry in neatly dressed stones for 23cms thick masonry walls in cm. 1:5 (1cement:5 fine sand) in foundation up to plinth level.
Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded granitic or basaltic stone aggregate 20 mm nominal size) excluding cost of centering, shuttering and finishing : b). In retaining walls , return walls(any thk) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc, upto floor five level.
18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
Providing and fixing G.I. chain link mesh 6.35cm x 6.35 cm x 10 gauge (2.5” x 2.5” x 10 gauge) fixed with angle iron posts and struts by G.I. or M.S. staples at 20cms apart with welding with the iron posts (placed at 3 meters centre to centre) including providing barbed wire stiffeners (shall weigh 9.33 kg. per 100 meters minimum) at top and bottom with barbed wire stiffer by binding wires at 50cms centre to centre complete as per the direction of the Engineer – in – charge (angle iron post, struts, earthwork and concrete for fencing posts and struts to be paid separately) .
Security room 3.50X3.50m clear size height 2.2mts, panel thickness 30mm with one door, two windows, Vinyle flooring, one light , one fan all directed by Engineer in charge .
Painting three or more coats with acrylic exterior paint of approved brand and manufacture (Such as Dulex/ Asian Paints/Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete.
Sub Estimate 6 :- Electrical accessories & internal wiring.
Supply of 3 ½ core armored PVC/XLPE insulated PVC sheathed aluminum conductor cable of 1.1 kv grade with ISI mark confirming to IS:1554 (part I ) , IS:7098 (Part I) with latest amendments of following size including laying of one number PVC insulated and PVC sheathed/XlpE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 300 sq.mm direct in ground including excavation in the form of a trench as per cable Trench Drawing provided by the Engineer-In charge, sand cushioning with screened sand bed of 20mm thick protective covering with bricks placed breadth-wise on top of cable all over the run (the brick protection shall cover the cable and project at least 5cm over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required. 3 ½ core x 300 sq.mm
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3 1/2 core pvc insulated pvc sheathed /XLPE aluminum conductor cable of 1.1 KV grade, complete as required. I) 3 1/2 x 300Sq.mm.
Supplying ,erection, testing & commissioning of 0.415KV Automatic Power factor Controller relay panel, APFCR should be having 12 stages, the total capacitors should be of 150 KVAR all the capacitors should be of heavy duty type and harmonics resistant . Make: L & T /Siemens
supplying, Erection ,Testing & commissioning of 50 x 6mm HDGI earth strip, duly clamped on walls/floors or to be laid underground as per their requirement.
Internal Lighting
Supplying and fixing following way SPN sheet steel MCB distribution board 240 v on surface/recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/ I ) (a)16 way double door Cat B
Supplying and fixing 6A to 32 A, C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. I ) (a)SP, Cat A
Supplying and fixing following way TPN sheet steel double door , vertical type MCB distribution board 415 v on surface/recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator) interconnection between incomer MCB and bus bars of following ways (but without MCBs as required) I) (a) 4way (8+12), double door, Vertical type, Cat A
Supplying and fixing following rating four pole 415 v isolator in the existing MCB DB complete with connections testing and commissioning etc as required I) (a)63 A , Cat A
Supplying and fixing 40A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. (a)SP, Cat A
Wiring for light point/fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface PVC conduit (medium) with modular switch, modular plates , suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required . (a) Group B - with Cat A Modular Accessories
Supplying and fixing following modular switch /socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (a)5/6 A Switch Cat A
Supplying and fixing following modular switch /socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (c) 15/16 A switch Cat A
Supplying and fixing following modular switch /socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (d) 3 pin 5/6 A socket outlet Cat
Supplying and fixing following modular switch /socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required (e)6 pin 15/16 A socket outlet Cat A
Supplying and fixing stepped type electronic fan regulator on the existing modular plate and switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as required.
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit (medium) of appropriate size as required. (a) 2 x 1.5 sq.mm +1x 1.5 sq.mm earth wire(20mm conduit)
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit (medium) of appropriate size as required. (b) 2 x 2.5 sq.mm +1x2.5 sq.mm earth wire (20mm Conduit)
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit (medium) of appropriate size as required. (c) 2 x 4 sq.mm + 1 x4 sq.mm earth wire (20mm Conduit)
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit (medium) of appropriate size as required. (d) 2 x6 sq.mm + 1 x 6 sq.mm earth wire (25 mm Conduit)
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit (medium) of appropriate size as required. (e) 4x 16 sq.mm + 2 x 16 sq.mm earth wire (40 mm Conduit)
Wiring for circuit / sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent surface PVC conduit (medium) of appropriate size as required. (f)4 x 16 sq.mm + 1 x 14 SWG earth wire
Supply and erecting of 48 inch (120mm sweep) ceiling fan, double ball bearing type, complete with all accessories.
Supply , Installation earthing , testing and commissioning of 4 feet 36/40 W single Patti type fluorescent luminaries with electronic ballast complete with all accessories including 4 feet 36/40 W fluorescent tube.
supply , Installation earthing , testing and commissioning of 4 feet 36/40 W double hanging type fluorescent luminaries with electronic ballast complete with all accessories including2 Nos 4 feet 36/40 W fluorescent tube including supplying and fixing ball and socket arrangement 2 no’s down rods of 20 mm dia x 1.6 mm thick steel conduit upto 30 cm length painting the down rods and connections with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and earthing etc. as required.
Supply and erecting of 18 inch (450 mm sweep) exhaust fan with double ball bearings, 140 rpm, heavy duty complete with all accessories.
Supply and erecting of 250 W sodium vapor indoor midbay luminaries, integral type IP 54., complete with all accessories including all control gear and 250 W sodium vapor lamp.
Supply and erecting of 250 w sodium vapor streetlight luminaries, integral type IP 54 complete with all accessories including all control gear and 250 W sodium vapor lamp. 0.415 KV 200 KW pump Sets.
supplying, Erection ,Testing & commissioning of 0.415 KV ., 50 Hz 35 KA indoor type LT PMCC panel with Two incomers ACB of 1250A, One Bus Coupler ACB of 1250A, Three motor feeders ACB of 630A, and other outgoing MCCB, MCB Feeders as required . The PMCC panel should have the necessary CT's relays, meters, etc as per the technical specifications Make: CG /Siemens/ L & T /ABB
Supplying , erection Testing & commissioning of LT Starters of the required type and as per the technical specifications as required by the manufacturer for 250 KW pump motor set.
Supply of following size of 3 core LV, 1.1 KV grade ISI mark , XLPE cable with stranded compact circular aluminum conductor , conductor screened with extruded semiconducting , compound XLPE insulated , insulation screened with extruded semiconducting compound in combination with copper tape (0.3 KA for 1 sec.) cores laid off, inner sheath of PVC tape, galvanized steel flat strip armored and overall PVC sheathed cable confirming to IS:7098 (part II) with latest amendments. 3 core 150 sq.mm
Supply of following size of 3 core LV, 1.1 KV grade ISI mark , XLPE cable with stranded compact circular aluminum conductor , conductor screened with extruded semiconducting , compound XLPE insulated , insulation screened with extruded semiconducting compound in combination with copper tape (0.3 KA for 1 sec.) cores laid off, inner sheath of PVC tape, galvanized steel flat strip armored and overall PVC sheathed cable confirming to IS:7098 (part II) with latest amendments. 3 core 185 sq.mm
Supply of following size of 3 core LV, 1.1 KV grade ISI mark , XLPE cable with stranded compact circular aluminum conductor , conductor screened with extruded semiconducting , compound XLPE insulated , insulation screened with extruded semiconducting compound in combination with copper tape (0.3 KA for 1 sec.) cores laid off, inner sheath of PVC tape, galvanized steel flat strip armored and overall PVC sheathed cable confirming to IS:7098 (part II) with latest amendments. 3 core 25 sq.mm
Supply of following size of 3 core LV, 1.1 KV grade ISI mark , XLPE cable with stranded compact circular aluminum conductor , conductor screened with extruded semiconducting , compound XLPE insulated , insulation screened with extruded semiconducting compound in combination with copper tape (0.3 KA for 1 sec.) cores laid off, inner sheath of PVC tape, galvanized steel flat strip armored and overall PVC sheathed cable confirming to IS:7098 (part II) with latest amendments. 4 core 16 sq.mm
Supply of following size of 3 core LV, 1.1 KV grade ISI mark , XLPE cable with stranded compact circular aluminum conductor , conductor screened with extruded semiconducting , compound XLPE insulated , insulation screened with extruded semiconducting compound in combination with copper tape (0.3 KA for 1 sec.) cores laid off, inner sheath of PVC tape, galvanized steel flat strip armored and overall PVC sheathed cable confirming to IS:7098 (part II) with latest amendments. 3 core 10 sq.mm
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3,4 core PVC insulated PVC sheathed /XLPE aluminum conductor cable of 1.1 KV grade , complete as required. 3 core 150 sq.mm
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3,4 core PVC insulated PVC sheathed /XLPE aluminum conductor cable of 1.1 KV grade , complete as required. 3 core 185 sq.mm
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3,4 core PVC insulated PVC sheathed /XLPE aluminum conductor cable of 1.1 KV grade , complete as required. 3 core 25 sq.mm
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3,4 core PVC insulated PVC sheathed /XLPE aluminum conductor cable of 1.1 KV grade , complete as required. 4 core 16 sq.mm
Supplying and making cable end terminations with brass compression gland and copper lugs for following sizes of 3,4 core PVC insulated PVC sheathed /XLPE aluminum conductor cable of 1.1 KV grade , complete as required. 3 core 10 sq.mm
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with CI/RCC cover having locking / lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the earthing Drawing provided by the Engineer -In charge. The scope of work includes the following: a) Excavation of pit of size 1.0 x 1.0 x 3.0 mts (min) and disposal of excavated soil. c) Watering GI pipe, 20 mm Class B, with funnel as per specs . d) charcoal/ salt as per specs (paid separately). e)Refilling the pit of size 1.0 x 1.0 x 3.0 mts (min) with soft black agriculture soil of minimum resistivity I/c transportation. e) Masonry chamber with proper foundation, cover plate and locking arrangement . f) Testing of earth value with earth megger and certifications of its value. g) watering arrangement (plumbing will be paid separately) a) In Soily strata
KVA High Tension Works.
Supplying & Erection of 11 Mts RCC poles including excavation , erection , transportation at site, dragging, providing of necessary concreting and muffing as per the requirements of GED Make: Michel & Michel /CBI/ Mahalaxmi.
Supplying, Erection, Testing & Commissioning of 11 KV 400 Amps pole mounted Gang operated AB switch with necessary support structure and accessories and separate earth arrangement and should be of makes : Atlas /S & S/RRI/ Hindustan chemicals.
Supplying , Erection, testing & Commissioning of 11 KV Disc insulators with metals parts and should be of makes: RRI /Hindustan chemical/ Birla or any make as approved by GED.
Supplying, erection, testing & Commissioning of ACSR RACOON conductor and should be of makes: Katari /KGV alloys/ Bharat conductors as approved by GED.
Supplying , erection , testing and commissioning of 11KV200Amps Pole mounted drop out fuse unit/HG use unit /Expulsion fuse unit having fuse links of ratings suitable to applied load with necessary support structure and accessories and separate earth arrangement and should be of makes : Atlas /S & S /RRI/Hindustan chemicals
Supplying , Erection Testing & Commissioning of 9 KV 10 K Pole mounted , lightening arresters with necessary support structure and accessories and separate earth arrangement , and should be of makes: Lamco /Crompton /Pactil.
Steel work in single sections (SAIL,TATA,VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position and applying a priming coat of red lead paint. In R.S. Joists , channels angles Tees.
Supply and providing Chemical earthing system (pipe in pipe type) with outer pipe of the electrode having minimum 80mm diameter as per the enclosed specifications and drawing. The outer and the inner hot dip galvanized MS pipes shall conform to the specifications and the space in between shall be filled with highly crystalline conductive and anti-corrosive mixture conforming to IS 3043. The earth electrode shall be CPRI tested. The scope of work includes boring (300mm dia minimum ) / excavation of soil/ hard rock, refilling with required quantity of back fill compound/ ground resistance enhancement powder of requisite quantity, compaction, construction of masonry chamber etc complete as required to obtain the desired value. Aluminum tag with embossed earthing value shall be permanently attached to the pipe electrode a) 3 meters length electrode
Supply of following size of 3 core HV, 11 KV grade ISI mark , XLPE cable with stranded compact circular aluminum conductor , conductor screened with extruded semiconducting , compound XLPE insulated , insulation screened with extruded semiconducting compound in combination with copper tape (0.3KA for 1 Sec.) cores laid off, inner sheath of PVC tape, galvanized steel flat strip armored and overall PVC sheathed cable confirming to IS:7098(Part II) with latest amendments .(9) 3 core 300 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground in the same trench in one tier horizontal formation, including excavation in the form of a trench as per Cable trench Drawing provided by the Engineer- In charge, sand cushioning with screened sand bed of 20mm thick, protective covering with bricks placed lengthwise on top of cable all over the run and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required . (a) Soily strata.
Supplying and making Indoor cable end termination with heat shrinkable kit for following sizes of PVC insulated PVC sheathed /XLPE aluminum conductor cable upto 11 KV grade, complete as required. (a) 11 KV, 3 core x 240 -300 sq.mm.
Supply and installation of RCC cable route marker
Supplying and Installing following size perforated type 14 SWG, M.S. Cable tray of GI pregalvanised/ hot dip galvanized/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required. 600mm width x 50mm depth
Supplying, erection, testing & Commissioning of firefighting system for switchyard having sand bucket and CO2 extinguisher etc. And other safety equipment like Danger boards, shock treatment chat, rubber hand gloves, Safety rubber mats, First aid box, Safety shockproof shoes etc.
Sub Estimate 7:- Pumps and Motors
Supplying ,Installing testing and commissioning of kirloskar/ Mather platt make Vertical Turbine pumps complete with strainer suction bowl, Column Assembly, discharge Head motor stool, flexible Coupling, sole plates, Base frame foundation, Non reversible Rotating Ratchet arrangement etc. capable of delivering 140 LPS against(720 cubic meter per hour) against maximum total head of 100meter coupled with motor in two pumps parallel operation ,pump coupled with Kirloskar/Crompton/Siemen/ABB three phase induction motor TEFC with F class insulation operating on 0.415 KV + 10% at 50 HZ + 5% with rating not exceeding 250KW confirming to IS 325 (1996) along with all accessories such as coupling, base plate, coupling guard, companion flanges, foundation bolts, pipe sleeve etc. inclusive of the cost of foundation grouting as per detailed specification and as directed by engineer in charge.
Supplying , laying , glanding, termination, lugging and testing of 6.6KVE,Grade XLPE insulated aluminum armoured cable 3 core x 95 sqmm type AYFY from MF panel to motor and capacitors including the cost of land dug as required for insulation cable duction from GI perforated angle cable tray made out of 40x40x6mm and flat 25x25x6mm including two coats of painting over the incoming cable from panel to motor of make : POLYCAB/FINOLEX/RP/CCI conforming to IS Specification all complete and as directed by the Engineer-in-charge.
Supply , installation and commissioning of indoor heat shrink termination kits of 6.6KVE , 3Cx95sqmm
Supplying , laying , glanding, termination and lugging wherever required with 6.0KV(E) , Grade , XLPE, PVC armoured insulated aluminum cable of approved brand of POLYCAB/FINOLEX/RPG/CCI or equivalent conforming to IS specification size 3C x 95 sq.mm incomer cable of AYFY between transformer to panel incomer including termination, excavation and backfilling with bricks and sand etc. complete and as directed by the Engineer in charge.
Supply, installation and commissioning of Indoor Heat shrink termination kits for 6.6KVE , 3C x 240 sq.mm .
Providing , installing , testing and commissioning of cubical type 3.3KV, HT 4panel , VCB switch gear with 630Amps bush bar HT panel (1 IC + 3 MF) fabricated out of 14 S.W.G. sheet steel , indoor panel suitable for installation of 3 phase , 3.3 KV system .The panel shall be of front floor standing , compartmentalised, dust and vermin proof in construction etc. complete with inter connections, requisite wiring shall be property derusted , degreed , phosphotised and with electrostatically powder coated to final finish of RAL 7032.
Providing , installing , testing and commissioning 415V. LT switch gear panel made out of 12/14 S.W.G. CRCA sheet duly painted with approved colour and requisite size of make Schneider/ L&T. or equivalent LT PANEL comprising of : i. 415 V, 200 A, MCCB for auxiliary transformer incoming feeder RYB indications, Ammeter, Voltmeter with SS of suitable rating CT’s , KWH, PF meters. ii. 415 V, 63 A, H.R.C switch fuse - 5nos iii. 415 V, 32 A, H.R.C. switch fuse – 6nos. iv. 415 V, 16 A, H.R.C. switch fuse – 5nos. v. Electrical motor starter RDOL type reversible push, button operated suitable for SV Valve motor rating of 1.1KW – 3nos.
Providing and laying GI earth plate from pits to the motors as directed by Engineer-in-charge a. 40 x 6 mm thick
Providing and laying GI earth plate from pits to the motors as directed by Engineer-in-charge b. 50 x 6mm thick
Earthing points to be made out of 600 x 600 x 6 G.I. Plate 1 pipe , funnel , salt , charcoal complete with excavation , backfilling , with bricks wall chamber and top chamber cover etc. as directed by the Engineer-in –charge.
Sub Estimate 8 :- Transformer Substation
Supply, Installation, Testing and commissioning of 33KV Switchyard comprising of structural steel as per drawing including applying two coat of red lead primer and two coat of superior quality paint etc complete as directed by the Engineer - in - Charge
Supply, Installation, Testing and commissioning of 33KV, 400A, Gang Operated Disconnector Switch, rotating, type, double break, complete with all standard accessories of make: ATLAS/Pactil/Kiron /L&T/Siemens confirming to IS specification
Supply, Installation, Testing and commissioning of 33KV, 400A, Gang Operated Disconnector Switch, rotating, type, double break, complete with all standard accessories and also complete with earth switch. Earth switch will be mechanically interlocked with castle key. Also suitable mechanical inter lock shall be provided for ATLAS/Pactil/Kiron /L&T/Siemens confirming to IS specification.
Supply, Installation, Testing and commissioning of 33KV, 200A, horn gap fuse link consisting of channel Iron base having 2 nos. 22KV post type insulators with all standard accessories, and manufactured as per IS: 5792- 1970 MAKE: ATLAS/Pactil/Kiron L& T/Siemens confirming to IS specification.
Supply, Installation, Testing and commissioning of 33KV outdoor type KIOSK for metering and check metering along with INSUL Coating
Supply, installation, testing and commissioning of 33KV, Outdoor type CT (Goa Electricity Dept. MRT tested) of CTR 25/5A, 15VA, Class 1.0 accuracy for metering. Make Gyro/AE/Kappa/Transdelta/Starlet confirming to IS specification.
Supply, Installation, Testing and commissioning of 33KV ,Outdoor type PT of PTR 33000/3/110/3 100 VA class -1 accuracy make : Gyro/AE/Kappa/Transdelta/Starlet confirming to IS specification.
Supply, Installation, Testing and commissioning of 33KV, 630 A,25KA, Out door type VCB complete with all std accessories and complete with foundation, make: ALSTOM/CGL/SIEMENS/ ABB/ BIELO LAWRIE make confirming to IS specification.
Supply, Installation, Testing and commissioning of C & R Panel for 33KV outdoor VCB comprising CDG31 relay with 2 over current & 1 earth fault. High speed tripping relay type VJAH13 Auxiliary Relay type VAA33 for 8 nos. transformer protection, 8 window annunciator with audio visual system for transformer protection's complete with all standard accessories wiring etc complete with foundation. Make: Alstorm/ CGL / Siemens / ABB / BIELO LAWRIE make confirming to IS specification.
a) Supply, Installation, Testing and commissioning of 33KV disc insulator with hardware consisting of 3 nos. of 11 KV disc & hardware
b) Supply, Installation, Testing and commissioning of 33KV post insulator with hardware
Supply, Installation, Testing and commissioning of 33KV, 10KA Station type Lightening arrestors. (1set of 3nos) Make: Elpro/Oblum make confirming to IS specification
Supply, Installation, Testing and commissioning of electronic digital meter in a weather proof box as approved by goa Electricity department make : secure /L&T or Equivanlent make conforming to IS specifications.
Plate type earth Electrodes with 600x600x6mm thick G.I. Plate, watering pipe, complete with charcoal, salt. G.I strip of 50x6mm funnel and masonry chamber with 300x300mm man hole cover, complete as per IS: 3042 including excavation
Supply, installation, testing and commissioning of G.I. strip for Earthing a. 50x6mm
Supply, installation, testing and commissioning of G.I. strip for Earthing b. 40x6mm
Supplying and spreading granitic/basaltic aggregate of 40mm nominal size
Supply, Installation, Testing and commissioning of 24 V DC Battery charger with maintenance free batteries of 100 AH complete with DCDB and ACDB
Supply, Installation, Testing and commissioning of ACSR Raccoon Conductor, complete with all connectors
Providing and fixing G.I. Chain Link fencing, fixed with angle arm holes, and struts including providing and fixing barbed wire at top and bottom of the fencing complete with 3mts wide gate etc. complete as directed by the Engineer- in – charge
Providing and fixing following safety Equipments a. Rubber mat suitable for 33KV Substation - 10mts. b. Fire Extinguishers 5kgs. DCP type-2nos c. Hand Gloves, 33KV grade - 1 No d. Fire buckets 4nos. With stand - 1 set
Supply, Installation, Testing and commissioning of 33KV, Switchyard lighting comprising 4nos lighting poles swaged type 9mts. Height with 24/30 W LED Outdoor light .
Supply, Installation, Testing and commissioning of 800 KVA, 33/3.3 KV, 50Hz 3 Phase, dynill, outdoor type ONAN transformer with on load tap changer on the HT side. The transformer will have cable box on the LV side and bare bushing on the HV side. The transformer is continuously rated for full load temperature in oil to exceeding 50˚ by thermometer (55°C for winding by measurement of resistance) over the average ambient temperature of 40°C including first filling of oil complying with a IS2026-1977 & comprising following accessories Make Volt amp/Transdelta/SVT/Urja/Equivalent as approved by the Engineer. 1. Conservator with oil filling hole with bolted cover plate and drain plug. 2. Prismatic oil level gauge. 3. Silica gel breather with oil seal. 4. Rating and Diagram plate. 5. Monogram plate. 6. Storage instruction plate. 7. Exposing vent with single diaphragm. 8.Thermometer pocket. 9. Top filter valve. 10. Drain cum bottom filter valve. 11.Air release plug 12. Inspection cover. 13. Lifting lufs. 14. Earthing Pads. 15.Bidirectional rollers 16. Skid type under base 17. RTCC with AVR Protection device considered 1. Buchholz relay with 1 shut off valve. 2. Winding temperature indicator with alarm & tripping contacts 3. Oil temperature indicator with alarm & tripping contact
Supplying, installing, testing and commissioning 100 KVA, transformer with off load Tap charger of approved make like SVT/Urja/Transdelta/ equivalent with I.S.I certification mark, operated on 3 phase 50HZ oil immersed, naturally coiled copper wound out door type 33 KV/433 vector group Dyn 11,ONAN,Outdoor type Transformer with off load Tap charger with +5% voltage tapping taken out on H.T. side in steps of +2.5% on H.T. winding connected in delta L.T winding connected in star and brought out and connected to separate terminal of earthing sets with temperature rise not exceeding 45° c with thermometer in oil and 55°c by resistance with first oil filling. The Transformer to placed on concrete pedestal as directed
Supply, Installation, Testing and commissioning of 1100V Grade PVC insulated copper armored cable, type YWY and of size 4x2.5 sq. mm including termination, glanding. Make unistar/polycab/Finolex confirming to IS specification
Supply, Installation, Testing and commissioning of 1100V Grade PVC insulated copper armored cable, type YWY and of size 2x16 sq. mm including termination, glanding.Makeunistar/polycab/Finolex confirming to IS specification
Supply, Installation, Testing and commissioning of 1100V Grade PVC insulated 3.5 C x 95 mm2 AYFY cable including termination, glanding. Make unistar/polycab/Finolex confirming to IS specification
Supply, Installation, Testing and commissioning of 100 KVAR Power Factor correction capacitors to be directly connected across the MF in HT Panel
Supply, Installation, Testing and commissioning of 40 KVAR Power Factor correction capacitors to be directly connected across the IC in HT Panel motor
Installation & Commissioning of 6.6 KV Indoor type Heat Shrink Termination Kit
Supply , Installation & Commissioning of 33 KV (E) 3C x 95 mm2 XLPE cable for Tapping Incoming Supply from GED to GED& Check Metering Kiosks etc
Supply , Installation & Commissioning of 2 Nos Out Door & 4 Nos Indoor Heat Shrink Termination Kits for 33 KV (E) 3 C x 95 mm2 XLPE cable.
Supply , Installation Testing and commissioning of control cable for Temp scanner, Elect. Actuators, Emergency stop , space heaters etc.
PRN INFRATECH
SOUTH EAST CONSTRUCTIONS COMPANY PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid