| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC PARUTHIYEZHATHU HOUSE MULAVUKAD P O NORTH ERNAKULAM 682 504 | ERNAKULAM | KERALA | 682504 | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹25.5 L+₹3.5 L (15.7%)Rejected-Finance 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | L2 | Rejected-Finance Other than Lowest Tenderer | |
| 3 | L3₹26.0 L+₹4.0 L (18.0%)Rejected-Finance NO 9 1ST FLOOR C J N HERITAGE PWD MAIN ROAD AKASH NAGAR B NARAYANAPURA DOORAVANI NAGAR BANGALORE 560016 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560016 | L3 | Rejected-Finance Other than Lowest Tenderer | |
| 4 | L4₹26.4 L+₹4.4 L (20.1%)Rejected-Finance D NO CC XX 1487 B1 CC 18 1786 B1 NEAR VVLP SCHOOL KONAM PALLURUTHY P O KOCHI 682006 | ERNAKULAM | KERALA | 682006 | L4 | Rejected-Finance Other than Lowest Tenderer | |
| 5 | L5₹27.6 L+₹5.6 L (25.3%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L5 | Rejected-Finance Other than Lowest Tenderer |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
14 Mar 2024, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
SPECIAL REPAIRS FOR REPLACEMENT OF BER PUMP SETS AT INS DRONACHARYA
2024_MES_636059_2
8979/E8/GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
FORT KOCHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE FORT KOCHI
₹48,000
Yes
11 Sept 2024
22 Feb 2024
21 Mar 2024
22 Feb 2024
14 Mar 2024
29 Feb 2024
Amount
Supply, install, test and commissioning of manufacturer's factory assembled and tested electric driven multistage centrifugal monoblock pump sets 14.91KW/20HP capable for delivering 1350 LPM at 32 Meter head coupled with three phase 415 volt complete of suction 100mm x delivery 65mm all as specified and as directed.
Supply, install, test and commissioning of manufacturer's factory assembled and tested electric driven centrifugal monoblock pump sets 5.5KW/7.5 HP capable for delivering 720 LPM at 36 Meter head coupled with three phase 415 volt complete of suction 65mm x delivery 50mm all as specified and as directed. Note for item no 1 & 2 :- (i) Quoted rate inclusive of Starter suitable for pump sets (ii) Quoted rate inclusive of necessary cutting/welding work if required to fix the starter in existing panel (iii) Foundation work if required at site shall be measured and paid seperately under respective items.
Supply, install, test and commissioning of Fire pump electrically driven horizontal end suction,centrifugal type,of capacity 67 KW/90HP confirming to IS 12469-1988 with CI casing,bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for continuous operation 0% to 150% of rated capacity for 440 Volt 3 phase 50Hz 60 Mtr head 2850 LPM discharge as per OEM recommendation with all accessories all as specified and as directed.
Supply, install,test and commissioning of electric driven Jockey pump horizontal end suction,centrifugal type,of capacity 7.45KW/10HP confirming to IS 12469-1988 with CI casing,bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for automatic operation with non over loading power charactorestics for start/stop operation for 440Volt 3 phase 50Hz 80 Mtr head 180 LPM discharge with star delta startor with all accessories all as specified and as directed.
Material and labour for taking up or down old unserviceable pump sets from any location up to 10 HP capacity include disconnectiong all electric connections,suction and delivery pipes,all fittings,nuts and bolts etc and and deposit the same to E/M store yard for further disposal complete all as specified and as directed.
-Ditto-all as per item No 5 above but of capacity 20 HP
-Ditto-all as per item No 5 above but of capacity 90 HP
M&L for earthing complete with galvanised iron or steel plate earth electrode of size 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level with top edge of the plate not less than 1.5 meter below ground level, earth plate shalll be surrounded on all sides with 15 cm thick layers charcoal dust mixed with salt connected to and including galvanised earth strip 32x 6 mm as earthing lead by means of GI nuts, bolts and washers at one end and other end shall be connected to test point complete all as shown on electric plate No 3 of SSR Part I (2009) including excavation and earth work in any type of soil, PCC pit (1:2:4), RCC earth pit cover and suitable handle, 20mm bore GI medium grade watering pipe with wire mesh and funnel, 40mm bore GI medium grade protection pipe including testing on completion complete all as specified and as directed.
Supply and connecting Flat three core PVC insulated and PVC sheathed copper industrial cable 1100 volts of size 6 sqmm complete all as specified and as directed.
Supply and connecting Flat three core PVC insulated and PVC sheathed copper industrial cable 1100 volts of size 10 sqmm complete all as specified and as directed.
Supply and connecting Flat three core PVC insulated and PVC sheathed copper industrial cable 1100 volts of size 35 sqmm complete all as specified and as directed.
Supply and fix pressure guage complete with suitable size of connecting pipe and taps etc of range 0 to 70 Kg/cm2 inlcuding removing the existing unserviceable pressure guage complete with connecting pipes, taps hole in the pumping line of any size complete all as specified and as directed.
Supply and fixing gunmetal non-return valve-horizontal (screwed end) 50 mm dia fixed with iron wheel bead screwed both ends for pipe and taking off the old fittings (including sweating off soldered joints where required), closing the opening with plug or preparing for new as required and removing old fittings from site complete all as specified and as directed.
Supply and fixing gunmetal non-return valve-horizontal (screwed end) 80 mm dia fixed with iron wheel bead screwed both ends for pipe and taking off the old fittings (including sweating off soldered joints where required), closing the opening with plug or preparing for new as required and removing old fittings from site complete all as specified and as directed.
Supply and fixing CI non-return valve-horizontal (screwed end) 100 mm dia fixed with iron wheel bead screwed both ends for pipe and taking off the old fittings (including sweating off soldered joints where required), closing the opening with plug or preparing for new as required and removing old fittings from site complete all as specified and as directed.
Supply and fix 100mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm complete all as specified and as directed
Supply and laying 62.5 mm inner dia CPVC schedule 80 pipes and plain CPVC 80 fittings on walls/ceilings or laying in floors and taking down old rusted GI tubing and complete all as specified and as directed.
Supply and laying 50 mm outer dia CPVC SDR 11 pipes and plain SDR 11 fittings on walls/ceilings or laying in floors and taking down old rusted GI tubing and complete all as specified and as directed.
-Ditto-all as per item No 18 but of size 40mm
-Ditto-all as per item No 18 but of size 25mm
-Ditto-all as per item No 18 but of size 20mm
-Ditto-all as per item No 18 but of size 16mm
Supply and laying 25 mm bore GI pipes and fittings medium grade with all fittings fixed to walls and ceilings or laid in floors incl taking down old rusted GI tubing complete all as specified and as directed.
-Ditto-all as per item No 23 but of size 50mm bore pipe
-Ditto-all as per item No 23 but of size 80mm bore pipe
-Ditto-all as per item No 23 but of size 100mm bore pipe
Supply and laying 25 mm bore GI pipes and fittings heavy grade with all fittings fixed to walls and ceilings or laid in floors incl taking down old rusted GI tubing complete all as specified and as directed.
-Ditto-all as per item No 27 but of size 50mm bore pipe
-Ditto-all as per item No 27 but of size 80mm bore pipe
-Ditto-all as per item No 27 but of size 100mm bore pipe
Material and labour for plain cement concrete 1:2:4,nominal mix, type B-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete etc. including use and waste of formwork as required/ ordered, complete all as specified and as directed.
M&L for taking down SCADA motorized valves of size 80/50mm dia with actuator,solinoid valve etc and refixing the same after carrying out necessary repair/replacement works on pipe lines complete all as specified and as directed Note :- Rate inclusive of provision of necessary CPVC/GI flanges required at site to fix the butterfly valve/motorized valve.
Supply and fixing in repair 15 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete and taking off the old fittings (including sweating off soldered joints where required), closing the opening with plug or preparing for new as required and removing old fittings from site complete all as specified and as directed.
-Ditto-all as per item No 33 above but of size 20mm bore pipe
-Ditto-all as per item No 33 but of size bore pipe 25mm
-Ditto-all as per item No 33 but of size 50mm bore pipe
Supply and fix CI Foot Valve conforming to IS 4038, 65 mm (2.5”) dia, all as specified and as directed by Engr-in-Charge.
Supplying and installing electro galvanised wire mesh cable trays of size 150 mm(w) x 54 mm(d) in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, painting suspenders etc as required all as specified and as directed by Engr-in-Charge.
National Electric Co
Glacier Cooling Solutions Private Limited
COCHIN CHEMICALS
MS BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .