Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance DOOR NO 2 561 BEHIND HOINA HOSTEL MOOGAMBIKA NAGAR PERIYAPALAYAM ROAD THIRUNINRAVUR CHENNAI 602 024 | CHENNAI | THIRUVALLUR | TAMIL NADU | 602024 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Apr 2023, 6:00 pmClosed
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
REPAIRS TO EM, BR INSTALLATION BUILDINGS INCLUDING INTERNAL ELECTRIFICATION IN TECHNICAL AND DOMESTIC AREA AT AFS BIDAR
2023_MES_586969_1
8208/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Bidar
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) Bidar
₹50,000
Yes
8 May 2023
25 Mar 2023
24 Apr 2023
25 Mar 2023
22 Apr 2023
8 Apr 2023
Amount
Taking down carefully copper/ aluminium point wiring (Light, fan, socket or power) complete all as specified and as directed.
Taking down existing unserviceable light fittings such as sketch type / box type / security light fittings by un screwing from boards / walls / buildings and making good disturbed surface to match with the existing complete all as specified and as directed.
Concealed point wiring with 1100V grade 1.5 Sqmm single core PVC insulated cable, copper conductor multistranded passing through and including concealed PVC 20mm dia (light duty) conduit and conduit accessories with concealed MS / PVC box and logic modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm as earth wire connected to common earth dolly as specified for one light point controlled by one switch all as specified and as directed. Note : (1) Rate quoted includes for cost of cutting chases in wall / floor / ceiling, making holes for MS / PVC box and making good to the original surfaces of any description disturbed. (2) Switch and socket shall be measured and paid for separately.
All as per item No. 03 here-in-before but in same board with other switches for 5 Amp switch socket with earth wire 1.5 sq mm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
All as per item No. 03 here-in-before but for 5 Amp switch socket on independent board complete all as specified and as directed.
All as per item No .03 here-in-before but size of cable 2.5 sqmm for 15 Amp switch socket with earth wire 2.5 sqmm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
Point wiring with 1100 V grade 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistranded passing through and including heavy duty PVC casing capping with all accessories, surface type on wall/ roof/ floor with concealed MS box / Surface type PVC box as required at site with laminated top cover duly earthed with 1.5 sqmm multistranded PVC insulated copper conductor cable for one light point /bell point /fan point controlled by one switch complete all as specified and as directed.
All as per item No.07 here-in-before but in same board with other switches for 5 Amp switch socket with earth wire 1.5 sqmm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
All as per item No. 07 here-in-before but for 5 Amp switch socket on independent board complete all as specified and as directed.
All as per item No. 07 here-in-before but size of cable 2.5 sqmm for 15 Amp switch socket with earth wire 2.5 sqmm PVC insulated multistranded copper conductor cable complete all as specified and as directed.
S & F in replacement of Switch piano flush, single pole, one way, 5/6 Amp, complete all as specified and as directed.
S & F in replacement of Switch piano flush, single pole, one way, 15 Amp, complete all as specified and as directed.
S & F in replacement of switch bell push piano, flush, single pole, 5/6 Amp,complete all as specified and as directed.
S & F in replacement of switch socket outlet 3 Pin 5 Amp, flush type, complete all as specified and as directed.
S & F in replacement of switch socket outlet multipurpose, 3 Pin 15/16 and 3pin 5/6Amp, 240 Volt, controlled by one switch complete all as specified and as directed.
S & F in replacement of switch modular type single pole one way 6 Amp with all accessories completeall as specified and as directed.
S & F in replacement of switch modular type single pole one way 16 Amp with all accessories complete all as specified and as directed.
S & F in replacement of socket outlet 3 Pin 6 Amp modular type all accessories complete all as specified and as directed.
S & F in replacement of socket outlet multipurpose 3 Pin 16A modular type with all accessories complete all as specified and as directed.
S & F in replacement of Bell push modular type 6A with all accessories complete all as specified and as directed.
S & F in replacement of ceiling rose three terminals 5 amps PVC / Polycarbonate, insulated body complete all as specified and as directed.
S & F in replacement of lamp holder, angular type, PVC / Polycarbonate with back plate 5 amps 230 V suitable for general lighting system ccomplete all as specified and as directed.
S & F in replacement of bell AC 230 Volt Ding Dong type, 240 Volt AC supply, complete all as specified and as directed.
S & F in replacement of fan regulator, AC, 230V, single pole electronic, step type, complete all as specified and as directed.
S & F in replacement of Two module, Fan regulator, step type, AC, 230V, electronic, complete all as specified and as directed.
S & F in replacement of single pole and neutral enclosure with a two pin earth plug and socket controlled by one single pole MCB 20 Amps 240 Volts complete all as specified and as directed.
S & F in replacement of MCB DB, SPN 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, SPN 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, SPN 12 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, TPN 4 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, TPN 6 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB DB, TPN 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, double door suitable for fixing MCBs and connecting etc., including taking down existing complete all as specified and as directed.
S & F in replacement of MCB SP 5 to 32 Amp complete all as specified and as directed.
S & F in replacement of MCB SPN 32 Amp complete all as specified and as directed.
S & F in replacement of MCB SPN 40-63 Amp complete all as specified and as directed.
S & F in replacement of MCB TPN 16-32 Amp complete all as specified and as directed.
S & F in replacement of MCB TPN 40-100 Amp complete all as specified and as directed.
S & F 20/22 W LED Surface mounted, batten fixture, 1200mm in length, with powder coated pressure dia cast aluminium housing and translucent diffuser. The fitting should have multichip on board LED metal clad PCB and dedicated heat shrink. The minimum lumens output of the system should not be less than 1450 lumens. The fitting should have surge protection of minimum 2 Kv input current <200mA, THD<10 % and CCT between 5000 k to 6500 K complete all as specified and as directed.
S & F 10/12 W LED Surface mounted, batten fixture 600 mm in length, with powder coated pressure dia cast aluminium housing and translucent diffuser. The fitting should have multichip on board LED metal clad PCB and dedicated heat shrink . The minimum lumens output of the system should not be less than 1450 lumens. The fitting should have surge protection of minimum 2 Kv input current <200mA, THD<10 % and CCT between 5000 k to 6500 K complete all as specified and as directed.
S & F LED bulb 9 W complete all as specified and as directed.
Supply, fix, test and commissioning 70 Watt LED street light fittings, High Efficiency IP 66 protection, powder coated pressure die cast aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED and metal clad PCB. The minimum lumen output of the system shall be greater than 7200 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system complete all as specified and as directed.
Supply, fix, test and commissioning 45 Watt LED street light fittings, High Efficiency IP 66 protection, powder coated pressure die cast aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED and metal clad PCB. The minimum lumen output of the system shall be greater than 7200 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system complete all as specified and as directed.
S & F 34 W IP LED panel made from CRC housing with full window acrylic diffuser indoor (recessed/ Pendent) 2ft X 2 ft lighting fixture flat light dissipater. The CCT should be between 3000 k to 6500 K complete all as specified and as directed.
S & F 36 W IP LED panel made from CRC housing with full window acrylic diffuser indoor (recessed/ Pendent) 1ft X 4 ft lighting fixture flat light dissipater. The CCT should be between 3000 k to 6500 K complete all as specified and as directed.
Sub main wiring with 2 runs of 4 sqmm, single core, FRLS PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surfaces of wall / floor with one run of FRLS PVC insulated 4 sqmm copper conductor for earth continuity including taking down existing submain wiring complete all as specified and as directed.
Sub main wiring with 2 runs of 6 sqmm, single core, FRLS PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surfaces of wall / floor with one run of FRLS PVC insulated 6 sqmm copper conductor for earth continuity including taking down existing submain wiring complete all as specified and as directed.
Sub main wiring with 2 runs of 10 sqmm, single core, FRLS PVC insulated, unsheathed, 1100 volts grade, multi stranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surfaces of wall / floor with one run of FRLS PVC insulated 10 sqmm copper conductor for earth continuity including taking down existing submain wiring complete all as specified and as directed.
S & F in replacement of switch socket combination flush type universal 2 in 1, 3 pin 5 amps 230 volts complete all as specified and as directed.
S & F in replacement of switch socket combination flush type universal 2 in 1, 3 pin 15 amps 230 volts complete all as specified and as directed.
S & F in replacement of modular switch socket combination 3 module , 3 pin 5 amps 230 volts complete all as specified and as directed.
S & F in replacement of modular switch socket combination 3 module , 6 pin 16 amps , 230 volts complete all as specified and as directed.
Dismantling the earth chamber, Excavation and removing the u/s earthing materials along with u/s earth electrodes from the existing u/s earth pits pertains to installations/ buildings and M/L for providing earthing with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to depth of not less than 2.25 mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to GI earth strip of 25x4mm by means of bolts, nuts, washers of GI and provision of earth lead, GI protection pipe with 15mm light grade galvanized including necessary earth work in any type of soil, PCC 1:3:6 type CI (using 20mm graded stone aggregate) earth chamber and 1:2:4 type B1 RCC cover fitted with 50mm thick with 6mm dia MS bars as shown in SSR Pt - 1 electrical plate No 3 complete all as specified and as directed. Note: Quoted rate deemed to include the cost or excavation and earth work PCC chamber, funnel cover etc
Taking down LT XLPE / PVC UG cable 1100 V grade of 2 core 10 sqmm to 3.5 Core 25 Sqmm connected from LT OH line to MCB DB, between the poles, transformer to LT Panels complete all as specified and as directed. Note: - Excavation and Earth work will be measured and paid seperately under the respective items
Supply, lay, connect, test and commisioning of LT XLPE insulated, screen, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor multistranded 10 Sqmm 2.0 Core, 1100 volts grade including connecting the cable ends to the LT Panel/ Transformer /LT OH lines and distribution board complete all as specified and as directed. Note: (i) The rates quoted deemed to be inclusive of necessary end terminations connecting materials such as lugs, nut bolt washers, aluminium jumper wire to suits the existing system.
All as per Item No. 54 here in before but of Capacity 10 sq.mm 4 core.
All as per Item No. 54 here in before but of Capacity 16 sq.mm 4 core.
All as per Item No. 54 here in before but of Capacity 25 sq.mm 3.5 core.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for taking out / for laying under ground cables / pipes etc and getting out in soft/loose soil complete all as specified and as directed.
Supply and spreading natural river sand in trenches for cushioning of under ground cable complete all as specified and as directed. Note: Punned thickness will be measured and paid for purpose of the payment.
Returning, filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed .
Removal of surplus excavated material ( soils) to a distance not exc., 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed.
Relaying serviceable unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and as directed.
Supply and laying unreinforced pre cast concrete cable cover class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection complete all as specified and as directed.
Dismantling unserviceable corroded building security light bracket and S&F Street light bracket made out of 40mm dia GI tubing medium grade upto 1.5 mtr long including bending, welding, drilling holes as required and fixing with flat iron clamps 32 x 6mm (2 Nos) with suitable nut, bolts and washers to steel tubular / concrete poles complete all as specified and directed
GI tubing medium grade with necessary fittings fixed to walls and ceiling or laid in floors, 15mm dia bore including taking down old steel tubing complete all as specified and as directed.
S&F GI tubing medium grade with necessary fittings fixed to walls and ceiling or laid in floors, 20mm dia bore including taking down old steel tubing complete all as specified and as directed.
S&F in repair Vitreous china squatting Pan 'Orrisa' Pattern size 580 x 440 mm white with integral foot rest , P or S Trap, and lime concrete bedding including making good disturbed surfaces complete all as specified and as directed.
S&F in repairs 10 ltr capacity PVC Low level flushing cistern including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm x 450mm long etc complete all as specified and as directed.
S&F in repairs Vitreous China Wash Hand Basins, size 550 X 400 mm (Flat Back or Angle Back type) including 32mm bore PTMT Waste coupling and PVC connection pipe of 15mm x 450mm long, a pair of angle iron brackets duly painted/ erecting stand including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3, complete all as specified and as directed
S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe including including 32mm bore PTMT Waste coupling and PVC connection pipe of 15mm x 450mm long complete all as specified and as directed.
S&F in repairs 15mm bore chromium plated cast copper alloy bib taps fancy type with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repairs 15mm bore angle stop cock of chromium plated fancy type, glossy finish complete all as specified and as directed.
S&F in repairs 15mm bore pillar taps, cast copper alloy fancy type with capstan heads, chromium plated screw down high pressure, screwed for iron pipe complete all as specified and as directed.
S&F in repairs tubular towel rail 20mm dia D type 60cm long between flanges chromium plated complete all as specified and as directed.
S&F in repair Plastic water closet seat, black or white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S&F in repairs 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F in repairs Grating doom 110mm dia of CP complete all as specified and as directed.
S&F in repairs waste coupling of PTMT (half or full threaded), Bore dia of discharge pipe 32mm. (Minimum weight -45gms) complete all as specified and as directed.
S&F in repairs PVC connection 450mm long of 15mm bore with pair of brass check nuts complete all as specified and directed.
S&F in repairs PVC waste pipe 32mm bore for WHB/Sink/Urinal complete all as specified and directed.
S&F in repairs 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified and as directed.
S&F Rotational moulded polyethene water storage tanks 1000 lit capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball (Minimum weight 210 gms), 20mm tank nipple including dismantling of existing water tank complete all as specified and as directed.
S&F Rotational moulded polyethene water storage tanks 500 lit capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including 20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball (Minimum weight 210 gms), 20mm tank nipple including dismantling of existing water tank complete all as specified and as directed.
S&F in repairs PVC OH tank covers of suitable dia complete all as specified and as directed.
S&F in repairs PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement etc complete all as specified and as directed.
S&F in repairs 110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete all as specified and as directed.
S&F in repairs 75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls etc complete all as specified and as directed.
S&F in repairs PVC (SWR) bends 110mm dia any radius with access door complete all as specified and as directed.
S&F in repairs PVC (SWR) bends 75 mm dia any radius with access door complete all as specified and as directed.
S&F in repairs PVC (SWR) junction single, (Single 'T') 110mm dia equal or unequal with access door complete all as specified and as directed.
S&F in repairs PVC (SWR) junction single, (Single 'T') 75mm dia equal or unequal with access door complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons laid bedded and pointed in any mortar etc, complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving n.exc 15cm thickness (below or above GL) including removal of debris outside MD land complete all as specified and as directed.
PCC 40mm thick 1:2:4 type B1 using 20 mm graded stone aggregate as in sub base complete all as specified and directed.
PCC 75mm thick 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection including necessary form work complete all as specified and as directed.
Coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15mm thick screed bed CM 1:6 complete all as specified and as directed.
Coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles including 15mm thick screed bed CM 1:6 complete all as specified and as directed.
Coloured glazed ceramic tiles in vertical surfaces such as skirting, dados and risers to steps etc., of size 350x250x7mm/ 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, including 10mm thick backing coat CM 1:4 complete all as specified and as directed.
Demolition of brick work, stone / boulder masonry, precast concrete block masonry etc., built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
Pre-cast cement concrete block masonry with solid blocks built in 1:3:6 type-C1 concrete (using 20mm graded stone aggregate), exc. 10cm in width and setting in mortar 1:6 complete all as specified and as directed.
Taking down cement plaster on brick or concrete or stone wall, or any description etc including, racking out joints, hacking for key scrubbing down with water etc. complete all as specified.
Rendering 15mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying three coats of white wash, complete all as specified and as directed.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
Applying one coat of white wash on old decorated surfaces of walls including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.
Preparation of old decorated surfaces of walls including cornices pillars etc by washing, rubbing down stopping and applying one coat of Oil Bound Distemper (of approved shade) complete all as specified and as directed.
Applying one coat of white wash on old decorated surfaces of ceiling including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and as directed.
Preparation of old decorated surfaces of walls including brooming down or steel wire brushing/scrapping down smoke soot mould, mass and efflorescent salts, trading off and greasy spots and applying one coat of cement based paint ( first quality) complete all as specified and as directed.
Preparation of old painted surfaces of wood and wood based materials of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint ( first quality ) complete all as specified and as directed.
Preparation of old painted steel and iron surfaces of any description over 10cm girth or width not otherwise described and applying one coat of synthetic enamel paint ( first quality ) complete all as specified and as directed.
Preparation of new wooden surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Taking down chowkats or frames not exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and as directed.
Taking down chowkats or frames exc 1.5 sqm but n.exc 4sqm each with shutters (without taking off shutters from the frame) complete all as specified and as directed.
Taking down shutters of any description n.exc 1 sqm each complete all as specified and as directed.
Taking down shutters of any description exc 1 sqm but n.exc 2 sqm each complete all as specified and as directed.
Taking down shutters of any description exc 1 sqm but n.exc 2 sqm each and refixing in the same opening after easing and adjusting complete all as specified and as directed.
Taking down shutters of any description exc 2 sqm each and refixing in the same opening after easing and adjusting complete all as specified and as directed.
Solid PVC door frames of size 50x47mm made out of 5mm plain colour PVC sheet, supplied and fixing in opening as per specification and drawing shown in SSR complete all as specified and as directed.
Factory made solid Panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for styles and Plain colour sheet PVC for top rails, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail supplied and fixed as per SSR instructions complete all as specified and as directed.
Factory made 30 mm thick flush shutters, solid core construction, with particle board core and ply wood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match complete all as specified and as directed.
Removing unserviceable builders hardware such as bolt, handle, stoppers, etc., of any specification / size complete all as specified and as directed.
Butt Hinges medium weight cold rolled mild steel 100 mm long complete all as specified and as directed.
Aluminum anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed.
Aluminum anodised barrel tower bolts of extruded section 100mm long complete all as specified and as directed.
Aluminum anodised bow handle fabricated type extruded section of 100mm long complete all as specified and as directed.
Aluminum anodised bow handle fabricated type extruded section of 150mm long complete all as specified and as directed.
Aluminum anodised sliding door bolts of 300mm long with hasp and staple(bolt type) and fixing clips of sheets, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
Hacking out old broken glass (any thickness size quality or description) from metal frame including punching or drilling out old glazing pins/spring clips, complete all as specified and as directed.
Sheet glass 4mm thick ordinary quality and glazing with oil putty in square n. exc 0.5 Sqm in each pane complete all as specified and as directed.
Taking down carefully hood and steel rolling shutters of size up to 20 sqm each and refixing in the same opening after cleaning of guide rails , laths, top cover by kerosene and proper greasing, oiling , replacement of rusted nut, bolt etc.,removing of bends & making alignment , denting, tension to spring, making smooth functional of rolling shutter and making good disturbed surfaces including preparation of old painted surfaces and applying one coat of synthetic enamel paint complete all as specified and directed.
S & F in repairs helical spring of 60cm long of rolling shutter complete all as specified and as directed.
S&F in repairs ball bearing of rolling shutter complete all as specified and as directed.
Welding in repairs n.exc 2.5cm in length and n.exc 6mm thickness of metal including cleaning and preparing the surface complete all as specified and as directed.
Siddique constructions
AMAR CONSTRUCTION
Mr Madhusudhan Kotarki
M Ramanaiah
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .