Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-Finance 34 10 37 1 GNANAPURAM DAYAS STREET VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L1 | Accepted-Finance Lowest Vendor | |
| 2 | L2₹27.0 L+₹1.1 L (4.42%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹28.0 L+₹2.1 L (8.28%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹28.7 L+₹2.8 L (10.8%)Rejected-Finance NEAR KONAM GUEST HOUSE CO OPERATIVE COLONY CHODAVARAM VISAKHAPATNAM 531036 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 531036 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹29.1 L+₹3.2 L (12.4%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | lakshmi Engineering Works L7 | M/s Jai Ganesh Engineering Solutions L5 | aswitha engineering works L1 | RAGHU RAMA PANDA L9 | M/s.Raghava Enterprises L6 | M/s SAI GANESH ENGINEERING ENTERPRISES L3 | GVR CONSTRUCTIONS L2 | SRK PROFESSIONAL ENGINEERING L8 | SINGH BUILDERS L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling taking out GI/MS pipe from PCC support/Trenches for repair/replacement/relaying for bore of pipe 150 mm complete all as specified and directed. | 300 | RM | 150 ₹45,000 | 50 ₹15,000 Lowest | 213.97 ₹64,191.6 | 367 ₹1,10,100 | 200 ₹60,000 | 150 ₹45,000 | 61 ₹18,300 | 150 ₹45,000 | 55 ₹16,500 |
| 2.00 | Supply, fixing and testing of 150 mm dia medium grade MS ERW pipe alongwith specials on PCC support or on trenches complete all as specified and directed.
Note :- Only flanges will be measured a supply only whereas all the specials required to make unit functional is deemed to be incuded in the above rate | 240 | RM | 2,400 ₹5,76,000 | 2,100 ₹5,04,000 | 1,071 ₹2,57,040 | 1,366 ₹3,27,840 | 2,000 ₹4,80,000 | 1,705 ₹4,09,200 | 2,450 ₹5,88,000 | 1,750 ₹4,20,000 | 950 ₹2,28,000 Lowest |
| 3.00 | M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 150 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed. | 60 | RM | 150 ₹9,000 | 100 ₹6,000 Lowest | 243.15 ₹14,589 | 547 ₹32,820 | 200 ₹12,000 | 255 ₹15,300 | 106 ₹6,360 | 350 ₹21,000 | 102 ₹6,120 |
| 4.00 | Dismantling taking out GI pipe from PCC support/Trenches for repair/ replacement/relaying for bore of pipe 200 mm complete all as specified and directed. | 300 | RM | 200 ₹60,000 | 100 ₹30,000 | 425.51 ₹1,27,653.75 | 547 ₹1,64,100 | 250 ₹75,000 | 250 ₹75,000 | 85 ₹25,500 | 250 ₹75,000 | 49 ₹14,700 Lowest |
| 5.00 | Supply, fixing and testing of 200 mm dia medium grade MS ERW pipe alongwith specials on PCC support or on trenches complete all as specified and directed.
Note :- Only flanges will be measured a supply only whereas all the specials required to make unit functional is deemed to be incuded in the above rate | 240 | RM | 3,500 ₹8,40,000 | 2,900 ₹6,96,000 | 2,431.85 ₹5,83,644 | 2,977 ₹7,14,480 | 2,500 ₹6,00,000 | 2,399 ₹5,75,760 | 3,150 ₹7,56,000 | 2,600 ₹6,24,000 | 2,100 ₹5,04,000 Lowest |
| 6.00 | M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 200 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed. | 60 | RM | 330 ₹19,800 | 100 ₹6,000 Lowest | 607.88 ₹36,472.5 | 808 ₹48,480 | 300 ₹18,000 | 355 ₹21,300 | 136 ₹8,160 | 350 ₹21,000 | 121 ₹7,260 |
| 7.00 | Excavation in trenches not exceeding 1.5M in depth and not exceeding 1.5M wide for pipe and getting out in soft/loose soil complete all as specified and directed. | 30 | CuM | 450 ₹13,500 | 290 ₹8,700 | 211.03 ₹6,331.05 | 349 ₹10,470 | 200 ₹6,000 | 195 ₹5,850 Lowest | 226 ₹6,780 | 350 ₹10,500 | 555 ₹16,650 |
| 8.00 | Excavation in trenches not exceeding 1.5M in depth and not exceeding 1.5M wide for cable/pipe and getting out in hard rock/Road/PCC hard standing and making the disturbed surfaces good same as existing before excavation complete all as specified and directed. | 3.24 | CuM | 650 ₹2,106 | 350 ₹1,134 | 1,365.98 ₹4,425.78 | 2,239 ₹7,254.36 | 1,500 ₹4,860 | 275 ₹891 | 246 ₹797.04 Lowest | 380 ₹1,231.2 | 1,859 ₹6,023.16 |
| 9.00 | Returning, filling in(soil), including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed. | 28.24 | CuM | 150 ₹4,236 | 90 ₹2,541.6 | 22.94 ₹647.68 Lowest | 88 ₹2,485.12 | 25 ₹706 | 95 ₹2,682.8 | 74 ₹2,089.76 | 150 ₹4,236 | 99 ₹2,795.76 |
| 10.00 | Removing excavated materials(soil) not exceeding 50M, depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. | 5 | CuM | 550 ₹2,750 | 110 ₹550 | 52.85 ₹264.27 Lowest | 259 ₹1,295 | 60 ₹300 | 125 ₹625 | 126 ₹630 | 150 ₹750 | 125 ₹625 |
Tender Value
₹42.0 L
EMD Value
₹84,040
Closing Date
19 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPAIR/REPLACEMENT OF FRESH WATER DISTRIBUTION PIPELINES OF VARIOUS SIZES 150MM TO 200MM AND DAY TO DAY MAINTENANCE ATTENDING COMPLAINTS/BREAKDOWNS/CALL ON REPAIRS AND INCLUDING ALLIED WORKS AT NAVAL DOCKYARD, VISAKHAPATNAM UNDER GE(I) DM VISAKHAPAT
2025_MES_740936_1
8419/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (I) DM VISAKHAPATNAM
₹84,040
Yes
5 Feb 2026
21 Nov 2025
22 Dec 2025
21 Nov 2025
19 Dec 2025
5 Dec 2025
22 Nov 2025 - 28 Nov 2025
Amount
Dismantling taking out GI/MS pipe from PCC support/Trenches for repair/replacement/relaying for bore of pipe 150 mm complete all as specified and directed.
Supply, fixing and testing of 150 mm dia medium grade MS ERW pipe alongwith specials on PCC support or on trenches complete all as specified and directed. Note :- Only flanges will be measured a supply only whereas all the specials required to make unit functional is deemed to be incuded in the above rate
M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 150 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
Dismantling taking out GI pipe from PCC support/Trenches for repair/ replacement/relaying for bore of pipe 200 mm complete all as specified and directed.
Supply, fixing and testing of 200 mm dia medium grade MS ERW pipe alongwith specials on PCC support or on trenches complete all as specified and directed. Note :- Only flanges will be measured a supply only whereas all the specials required to make unit functional is deemed to be incuded in the above rate
M&L for relaying of GI pipe above after proper cleaning, descalling and fixing to original position for bore of pipe 200 mm including necessary rubber gusket, nuts, bolts & washers complete all as specified and directed.
Excavation in trenches not exceeding 1.5M in depth and not exceeding 1.5M wide for pipe and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5M in depth and not exceeding 1.5M wide for cable/pipe and getting out in hard rock/Road/PCC hard standing and making the disturbed surfaces good same as existing before excavation complete all as specified and directed.
Returning, filling in(soil), including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated materials(soil) not exceeding 50M, depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Labour only for attending break down of pipe line bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes etc as per site requirement, testing for leakages of testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed by engineer-in-charge for the bore of GI pipe upto 150mm. Note 1:- The quoted rate is deemed to be include the following:- (i) arrangement of suitable pump sets for dewatering at the time of breakdown. (ii) Necessary labour/trade men for attending break down . (iii) labour element required for fixing CI/DI/MS pipes, specials fittings Note 2:-CI/DI/MS Pipes and specials will be measured and paid seperately under relevant items.Items which are not available as supply only are deemed to be included to make the unit completely functional
Labour only for attending break down of pipe line bursting/cracks and including cleaning/removal of broken pipe pieces of various lengths through gas cutting / manual cutting as per site requirement and including inserting necessary specials such as pipes etc as per site requirement, testing for leakages of testing and necessary dewatering by using necessary pumps, mechanical excavator complete all as specified and directed by engineer-in-charge for the bore of GI pipe upto 200mm. Note 1:- The quoted rate is deemed to be include the following:- (i) Arrangement of suitable pump sets for dewatering at the time of breakdown. (ii) Necessary labour/trade men for attending break down . (iii) labour element required for fixing CI/DI/MS pipes, specials fittings Note 2:-CI/DI/MS Pipes and specials will be measured and paid seperately under relevant items.Items which are not available as supply only are deemed to be included to make the unit completely functional
Supply & fix only CI sluice valve flanged type 150 mm dia PN 1.6 fitted with hand wheel including fixing to pipe line with gusket, nuts, bolts and washers complete including taking out old unserviceable sluice valve complete all as specified and directed.
Supply & fix only CI sluice valve flanged type 200 mm dia PN 1.6 fitted with hand wheel including fixing to pipe line with gusket, nuts, bolts and washers complete including taking out old unserviceable sluice valve complete all as specified and directed.
Supply & fix only mechanical joints 150 mm dia PN 1.6 fitted with hand wheel including fixing to pipe line with gusket, nuts, bolts and washers complete including taking out old unserviceable sluice valve complete all as specified and directed.
Supply & fix only mechanical joints 200 mm dia PN 1.6 fitted with hand wheel including fixing to pipe line with gusket, nuts, bolts and washers complete including taking out old unserviceable sluice valve complete all as specified and directed.
Supply & fix only GI threaded flange joints alongwith flanges of size 150 mm complete all as specified and directed.
Supply & fix only GI threaded flange joints alongwith flanges of size 200 mm complete all as specified and directed.
Supply & fix only rubber gusket of size 150mm complete all as specified and directed.
Supply & fix only rubber gusket of size 200mm complete all as specified and directed .
Surface dressing of areas of above pipelines by clearing away all grass,wild vegetation,saplings,shrubs,brushwood,undergrowth,roots and tress not exceeding 30cm girth and removing rubbish upto a distance of 50mts outside the periphery of the area under clearance complete all as specified and as directed.
M&L for valve chamber of internal size not less than 1200 x 1200 x 1200mm with cement brick plastering the surfaces with three coats of white wash incl MS sheet cover of not less than 3mm thickness with MS angle not less than 40mmx40mmx5mm including proper locking arrangement and fabrication for air release valve painting with one coat of red oxide primer and one coats of anticorrosive black bituminous paint incl dismantling mild steel work of any description not otherwise specially provided for all as specified and directed.
M&L for preparation of valve chambers smooth as existing and applying three coats of white wash and applying synthetic enamel black paint after cleaning the debris and vegetation etc per month complete all as specified and directed.
M&L for mild Steel framed work with ends of bars souldered, welded or reveted or forced into spikes, framed guard bars, ladders,chequred plates framed balusters, walk ways, railings, gates, frame work of tank, valvepit and similar work incl painting with one coat of red oxide primer and one coats of anticorrosive black bituminous paint incl dismantling mild steel work of any description not otherwise specially provided for all as specified and directed.
M&L for dismatling of foundation PCC, taking out from pump house, carrying to dumping yard inside ND (V) and necessary cleaning of work site all as specified and directed..
M&L for cement concrete type B1, (1:2:4) with 20mm graded agreegate in foundation, filling in and mass concrete all as specified and directed.
GVR CONSTRUCTIONS (BID ID -3496408)
M/s SAI GANESH ENGINEERING ENTERPRISES (BID ID -3496128)
SINGH BUILDERS (BID ID -3496272)
M/s Jai Ganesh Engineering Solutions (BID ID -3496274)
M/s.Raghava Enterprises (BID ID -3502806)
lakshmi Engineering Works (BID ID -3495914)
SRK PROFESSIONAL ENGINEERING (BID ID -3495748)
RAGHU RAMA PANDA (BID ID -3499349)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
8419tender.pdf
Tender Documents • 1.05 MB
BOQ_829667.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .