EE-I,WKED,PWDte.
New Secretariat Building, C Block, 4th floor 1, K.S Roy Road, Kolkata-700001
Supply, Installation, Testing and Commissioning of Split type AC machines at the Court No-1 to replace the existing old AC machines at Main Building of the Honble High Court at Calcutta.
2026_WBPWD_5078811_1
WBPWD/EE-WKED/sh-NIT-90/26-27
Open Tender
A/C ORG
Item Rate
10 days
High Court, Calcutta
Please refer Tender documents.
6 documents required · 6 mandatory
₹12,032
9 Oct 2026
9 Oct 2026
14 Oct 2026
9 Oct 2026
12 Oct 2026
9 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS / International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only [32.2] (Make - Mitsubishi Heavy / O General) | |||||
| 1.1 | 2.0 TR with 5 Star BEE Rating Inverter Type | 6 | Each | - | - |
| 2.1 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : [31.14] | - | - | - | - |
| 2.2 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [DSR31.14.1 ] | 124 | RM | - | - |
| 2.3 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [DSR 31.14.4] | 124 | RM | - | - |
| 3 | Supply & Laying of 4 core 2.5sq.mm 1.1 KV insulation grade sheathed Cu cable with gas line as per direction of EIC for making interconnection/communication between Indoor to Outdoor unit of Split type AC m/c.(Make- Havells/Gloster/RR Kabel as approved by E.I.C) | 132 | Mtr | - | - |
| 4 | Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC | 56 | Mtr | - | - |
| 5 | Supplying, fabrication & fixing 2 Nos. M.S. Angle of size (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit of 3.0/4.0 TR ceiling concealed AC incl. drilling 2 nos holes in each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be baricated & safe for ODU maintenance. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC. | 4 | No. | - | - |
| 6 | Supply & laying 1.1 KV grade 3 core 4 sqmm flexible copper Cable with screw, saddle,drill machine nut bolt etc all necessary items needed for connection. (from starter to A.C outdoor Connection)Make- Havells/Gloster/RR Kabel as per approved by EIC) | 90 | Mtrs | - | - |
| 7 | Dismantling the indoor and Outdoor unit existing AC machines after necessary electrical and mechanical disconnection and reinstallation of the same with necessary reconnection/welding etc. as per instruction of Competent Authority and their safe shifting and stacking at the designated ground-floor or basement area of the SC Building.
[Rate obtained from Sr. SE vetted Est. No. 01/HCESD of 26-27, item sl. no. 22] | 4 | No. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.87 MB
BOQ_5179878.xls
BOQ • 0.29 MB
WBF-2911.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .