Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹531.3 Cr
EMD Value
₹5.3 Cr
Closing Date
27 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Ukai Division No 1 Ukai
Engineering, Procurement And Construction (Epc) Contract For Tapi River Based Borisavar Lift Irrigation Scheme pressurised Irrigation Networks (Pins) For Songadh And Vyara Taluka Of Tapi District With Operation And Maintenance For 10 Years.
243725
E-TENDER NOTICE NO. 23 of 2025-26
Open
Civil - All
Works
Tapi
15 documents required · 15 mandatory
₹18,000
Songadh
₹5.3 Cr
17 Nov 2025
17 Nov 2025
17 Nov 2025
27 Jan 2026
17 Nov 2025
Price Schedule - A, Civil and Pipiline Works Detail engineering, Geological and Field to Field survey, investigation, fixing alignment, design-drawing for Irrigation service network, approval of the planning design and drawing and raw water filling of village tanks, Fabrication/ Manufacturing and supplying of pipes with all accessories Lowering, laying, fixing including all control works and outlets and testing of pipe lines for all distributaries, minor and sub minors, outlets and raw water filling of village tanks of command area sanction by competent authority, getting approval from competent authorities as per design criteria of Department, relevant I.S. codes, IRC Publications and circulars issued by the Department from time to time. Preparing ROW cases and permanent land acquisition cases if required (Private land, Government land, Forest land if any), property cases, if any, such as wells, trees, houses, land in Gamtal etc., Preparing Schedule for ROU, Standing Crop Compensation and make payment coming under approved alignment of distribution network and processing for acquisition, preparing of chak wise, minor wise and WUA wise beneficiary list etc complete. Commissioning and trial of the constructed pipe line system of the distribution network etc.
Construction of RCC BOX as approach channel in Tapi river including all necessary work need to complete for operational of the project.
Constructing RCC Under Ground water collection tank of 24.831 m x 34.26 m size with minimum 21 m including drain pit sump,Pump house - 1 of 25.431 m x 34.86 m with minimum height 12.5 m including valve controlling chamber & Fire fighting room of 6.166 m x 14.816 m with minimum height 6 m all other essential office room required for functioning and loading unloading bay of required width with required column, beam, bottom, slab, top slab with reinforcement, plastering, painting, floor finishing, etc. The work also includes constructing R.C.C. column, Beam etc. complete. The trash rack arrangement is to be arranged in sump area with E.O.T. arrangement with required R.C.C. column, beam, slab, G.I. railing, structural steel etc. complete at Vaghnera Village P.S.- 1 etc Complete
Constructing R.C.C. framed structure for control room / M.C.C. room of minimum size 52.00m X 11.23 m with minimum height 5 m at Vaghnera village P.S. - 1 with along PLC - SCADA, office room, Battery & Charger with DCDB room including Toilet facility with stair arrangement with required column, beam. top slab with reinforcement, plastering, painting, floor finishing with required water supply, sanitary arrangement as per drawing or as per instruction by engineer in charge and all necessary work need to complete for operational of the project.
Constructing RCC Under Ground sump of 40.30 m x 40.30 m size with minimum 9 m including drain pit sump,Pump house - 2 of 40.9 m x 18.88 m with minimum height 11.7 m including valve controlling chamber & Fire fighting room of 5.758 m x 7.995 m with minimum height 6 m all other essential office room required for functioning and loading unloading bay of required width with required column, beam, bottom, slab, top slab with reinforcement, plastering, painting, floor finishing, etc. The work also includes constructing R.C.C. column, Beam etc. complete. The trash rack arrangement is to be arranged in sump area with E.O.T. arrangement with required R.C.C. column, beam, slab, G.I. railing, structural steel etc. complete at Kavala Village P.S.- 2 etc Complete
Constructing R.C.C. framed structure for control room / M.C.C. room of minimum size 39.232 m X 11.23 m with minimum height 5 m at Kavla village P.S. - 2 with along PLC - SCADA, office room, Battery & Charger with DCDB room including Toilet facility with stair arrangement with required column, beam. top slab with reinforcement, plastering, painting, floor finishing with required water supply, sanitary arrangement as per drawing or as per instruction by engineer in charge and all necessary work need to complete for operational of the project.
Constructing RCC Under Ground sump of 25.8 m x 29.8 m size with minimum 9 m including drain pit sump,Pump house - 3 of 26.54 m x 15.0 m with minimum height 11.7 m including valve controlling chamber and all other essential office room required for functioning and loading unloading bay of required width with required column, beam, bottom, slab, top slab with reinforcement, plastering, painting, floor finishing, etc. The work also includes constructing R.C.C. column, Beam etc. complete. The trash rack arrangement is to be arranged in sump area with E.O.T. arrangement with required R.C.C. column, beam, slab, G.I. railing, structural steel etc. complete at Kanala Village P.S.- 3 etc Complete
Constructing R.C.C. framed structure for control room / M.C.C. room of minimum size 43.73 m X 11.23 m with minimum height 5 m at Kanala village P.S. - 3 with along PLC - SCADA, office room, Battery & Charger with DCDB room including Toilet facility with stair arrangement with required column, beam. top slab with reinforcement, plastering, painting, floor finishing with required water supply, sanitary arrangement as per drawing or as per instruction by engineer in charge and all necessary work need to complete for operational of the project.
Construction of compound wall/ boundry wall of length 462 Rmt. with spiral wire fencing at top of wall with RCC column footing spaced at 2.5 mc/c distance and strom water drain at Vaghnera Village P.S. - 1 as per instruction by engineer in charge.
Construction of compound wall/ boundry wall of length 372 Rmt. with spiral wire fencing at top of wall with RCC column footing spaced at 2.5 mc/c distance and strom water drain at Kavala Village P.S. - 2 as per instruction by engineer in charge.
Construction of compound wall/ boundry wall of length 281 Rmt. with spiral wire fencing at top of wall with RCC column footing spaced at 2.5 mc/c distance and strom water drain at Kanala Village P.S. - 3 as per instruction by engineer in charge.
Construction of twin staff quarter at Vaghnera Village P.S. - 1, at Kavala Village P.S. - 2 and at Kanala Village P.S. - 3 With required water supply ,sanitary arrangement, electrification and all necessary works required for operation of project.
Construction of Security Cabin at Vaghnera Village P.S. - 1, at Kavala Village P.S. - 2 and at Kanala Village P.S. - 3 with all necessary works required for operation of project.
Construction of Internal approach road of 4.0 m wide ( rigid pavement ) in Premises of P.S. -1, P.S.-2 and P.S.-3.
Construction of External approach road of 4.00 m wide to connect P.S.-1 from Vaghnera village, to connect P.S. -2 from Kavala village and to connect P.S.-3 from Kanala village.
Constructing Room for Fire Fighting system near Pumping station in R.C.C. frame structure of minimum internal size 10 M x 8 M with minimum 5 m height from Plinth Level at Kanala village P.S.-3 with required column, beam, bottom, slab, top slab with reinforcement, door, window, ventilation, stair case, plastering, painting, floor finishing, etc. including supporting column, beam in sump area as per requirement and as per instruction by engineer in charge.
Excavation for Pipe line trenches for water supply, sewerage line, manhole etc. all with shoring and shruting if required as per required gradient an line including safety provisions using site rails and stacking excavated stuff including up to all required lead, cleaning the site etc. complete for all lifts and strata as specified. (A) 0.0 to 1.5 M depth In all Sorts of Soil & Soft Murrum 50 percent
In hard murrum, boulders incl. macadam road. 40 percent
In soft rock and/or masonry in CM or L M or Lime Concrete. 10 percent
(B) 1.5 mt to 3.0 M depth In soft rock and/or masonry in CM or L M or Lime Concrete. 90 percent
In hard rock and / or in C. C. 1:2:4 or RCC with blasting and chiseling or by chiseling only. 10 percent
( C )3.0 to 4.5 M depth In hard rock and / or in C. C. 1:2:4 or RCC with blasting and chiseling or by chiseling only. 100 percent
Manufacture, Supply & Delivery of Electric Resistance Welded (Up to 400mm)/Submerged Arc Welded(Above 400mm) M.S.Pipe having beveled ends plate or coil conforming to IS-3589-2001 or its latest revision/ ammendment for following thickness outside diameter at GWSSB store or site anywhere in Gujarat State including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading conveyance to Departmental stores, stacking etc. all complete. I/S Solvent free Liquid Epoxy Lining (406 micron) + O/S 3 LPE Coated M. S. Pipe For OD - 1626 mm
For OD - 1422 mm
For OD - 1219 mm
For OD - 1067 mm
For OD - 1016 mm
For OD - 914 mm
For OD - 813 mm
For OD - 711 mm
For OD - 610 mm
For OD - 508 mm
For OD - 457 mm
For OD - 406.4 mm
Lowering, laying, jointing & welding in position to correct line and level M.S. pipe with outer side 3 LPE coating and inside solvent free liquide epoxy lining on pedestal or chairs upon prepared formation or preperd bedding in trenches. The rates include conveyance from store to site of work loading, unloading, joint and hydrotesting etc. complete. For OD - 1626 mm
For OD - 1422 mm
For OD - 1219 mm
For OD - 1067 mm
For OD - 1016 mm
For OD - 914 mm
For OD - 813 mm
For OD - 711 mm
For OD - 610 mm
For OD - 508 mm
For OD - 457 mm
For OD - 406.4 mm
Providing and supplying in standard length ISI mark high density Polyethylene H.D.P.E. Pipes suitable for potable water as per IS specification no. 4984/1995 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the dept. stores etc. comp. (6 kg/sqcm) For OD - 355 mm
For OD - 315 mm
For OD - 280 mm
For OD - 250 mm
Item Description
Price Schedule - A, Civil and Pipiline Works For OD - 225 mm
For OD - 200 mm
For OD - 180 mm
For OD - 160 mm
For OD - 140 mm
For OD - 125 mm
For OD - 110 mm
For OD - 90 mm
Providing and supplying in standard length ISI mark high density Polyethylene H.D.P.E. Pipes suitable for potable water as per IS specification no. 4984/1995 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the dept. stores etc. comp. (10 kg/sqcm) For OD - 355 mm
For OD - 315 mm
For OD - 280 mm
For OD - 250 mm
For OD - 225 mm
For OD - 200 mm
For OD - 180 mm
For OD - 160 mm
For OD - 140 mm
For OD - 125 mm
For OD - 110 mm
For OD - 90 mm
Providing and supplying in standard length ISI mark high density Polyethylene H.D.P.E. Pipes suitable for potable water as per IS specification no. 4984/1995 including all local and central taxes, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to the dept. stores etc. comp. (12.5 kg/sqcm) For OD - 355 mm
For OD - 315 mm
For OD - 280 mm
For OD - 250 mm
For OD - 225 mm
For OD - 200 mm
For OD - 180 mm
For OD - 160 mm
For OD - 140 mm
For OD - 125 mm
For OD - 110 mm
For OD - 90 mm
Lowering, laying, and jointing H.D.P.E. and specials of following class and diameter (by butt fusion welding method) including cost of conveyance from stores to site of works at all level including cost of labour, material, giving satisfactory hydraulic testing etc. complete. For OD - 355 mm
For OD - 315 mm
For OD - 280 mm
For OD - 250 mm
For OD - 225 mm
For OD - 200 mm
For OD - 180 mm
For OD - 160 mm
For OD - 140 mm
For OD - 125 mm
For OD - 110 mm
For OD - 90 mm
Refilling the excavated trial pits and tranches using the excavated stuff as directed.
Providing bedding incl. ramming, watering, levelling, consolidating etc. Complete as per standard and instruction of engineer incharge. As above with required quality Sand brought from outside inclduing all lead.
Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. -PN 1.0 with gear operated (PD type short body) 80 dia PN-1.0
100 dia PN-1.0
150 dia PN-1.0
200 dia PN-1.0
Item Description
Price Schedule - A, Civil and Pipiline Works 250 dia PN-1.0
300 dia PN-1.0
350 dia PN-1.0
400 dia PN-1.0
450 dia PN-1.0
500 dia PN-1.0
600 dia PN-1.0
1000 dia PN-1.0
1200 dia PN-1.0
1400 dia PN-1.0
Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. -PN 1.6 with gear operated (PD type short body) 80 dia PN-1.6
100 dia PN-1.6
150 dia PN-1.6
200 dia PN-1.6
250 dia PN-1.6
300 dia PN-1.6
350 dia PN-1.6
400 dia PN-1.6
450 dia PN-1.6
500 dia PN-1.6
600 dia PN-1.6
700 dia PN-1.6
800 dia PN-1.6
900 dia PN-1.6
1000 dia PN-1.6
1400 dia PN-1.6
1500 dia PN-1.6
Lowering, laying and jointing in position following Sluice valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 80 dia
Providing and supplying ISI mark CI D/F Scour Valves as per IS:14846 (Latest Edition) of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. -PN 1.6 with gear operated (PD type short body) 50 dia PN-1.6
80 dia PN-1.6
100 dia PN-1.6
150 dia PN-1.6
200 dia PN-1.6
Item Description
Price Schedule - A, Civil and Pipiline Works 250 dia PN-1.6
350 dia PN-1.6
400 dia PN-1.6
500 dia PN-1.6
600 dia PN-1.6
Lowering, laying and jointing in position following Scour valves including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing, etc. complete. 50 dia PN-1.6
80 dia PN-1.6
100 dia PN-1.6
150 dia PN-1.6
200 dia PN-1.6
250 dia PN-1.6
350 dia PN-1.6
400 dia PN-1.6
500 dia PN-1.6
600 dia PN-1.6
Providing, and supplying C. I. Temper proof Air valves with an isolation sluice valve. Air valves having SS 304 Float gun metal- nozzle of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. With Isolating Sluice valve PN 1.0 50 MM DIA
80 MM DIA
100 MM DIA
150 MM DIA
200 MM DIA
Providing, and supplying C. I. Temper proof Air valves with an isolation sluice valve. Air valves having SS 304 Float gun metal- nozzle of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. With Isolating Sluice valve PN 1.6 50 MM DIA
80 MM DIA
100 MM DIA
150 MM DIA
200 MM DIA
Lowering ,laying & jointing in position following Air valves incl. cost of all labour , jointing material incl nut bolts and giving satisfactory hydraulic testing etc. complete. Air valves double ball flanged 50 MM DIA
80 MM DIA
100 MM DIA
150 MM DIA
200 MM DIA
Providing, supplying. lowering, laying, jointing of "Series 100 Standard Dorot Pressure Reducing Valve Hydraulically Operated, MOC (DI) Pressure Rating:PN 16; ,Tubing High Pressure Polypropylene." Pressure reducing valve 250 MM DIA
350 MM DIA
400 MM DIA
500 MM DIA
Construction of RCC Valve Chambers of different sizes for different valves such as :The rates shall include construction of RCC valve chamber in M 30 concrete R.C.C.works. Excavation, foundation concrete 100 mm thick in 1:3:6 proportion, pedestal and vertical wall in CC M30, top cover of RCC precast slabs & cover in pieces of required size with necessary nuts, bolts, locking arrangements, PVC encapsulated Rungs etc. complete as per drawing & specification and instruction of EIC / Consultant. For Sluice valve Valve chember for 80 dia
Valve chember for 100 dia
Valve chember for 150 dia
Valve chember for 200 dia
Valve chember for 250 dia
Valve chember for 300 dia
Valve chember for 350 dia
Valve chember for 400 dia
Valve chember for 450 dia
Valve chember for 500 dia
Valve chember for 600 dia
Valve chember for 700 dia
Valve chember for 800 dia
Valve chember for 900 dia
Valve chember for 1000 dia
Valve chember for 1200 dia
Item Description
Price Schedule - A, Civil and Pipiline Works Valve chember for 1400 dia
Valve chember for 1500 dia
For Scour valve with over flow chamber Valve chember for 50 dia PN-1.6
Valve chember for 80 dia PN-1.6
Valve chember for 100 dia PN-1.6
Valve chember for 150 dia PN-1.6
Valve chember for 200 dia PN-1.6
Valve chember for 250 dia PN-1.6
Valve chember for 350 dia PN-1.6
Valve chember for 400 dia PN-1.6
Valve chember for 500 dia PN-1.6
Valve chember for 600 dia PN-1.6
For Pressure release valve Valve chember for 250 dia
Valve chember for 350 dia
Valve chember for 400 dia
Valve chember for 500 dia
Air valve shaft - providing arrangement of min 4.2 M height with MS pipe shaft with encasing of shaft in RCC M20 and providing and fixing M.S pad as per drawing. 50 MM DIA
80 MM DIA
100 MM DIA
150 MM DIA
200 MM DIA
Road reinstatement of asphalt road pavement including providing and supplying all materials, labour including soling, metalling, grouting with tack coat, carpet, seal coat etc. complete.
Providing and laying plain/ reinforced Design Mix cement concrete of various grade with cement, sand and coarse aggregates including centering, shuttering, batching, mixing, transporting, placing, vibrating, smooth finishing, curing etc. complete for all lead and lifts (BATCHING PLANT BASED)(EXCLUDING DEWATERING) Raft, bottom slab of barel, footing of columns etc. (ii) M-20 grade
Providing and placing in position reinforcement bars including cutting, bending welding, joints where necessary, hooking etc. complete as per drawing for all lead and lifts. (b) TMT
Pipe pushing For State Highway, National highway Crossings and Canal crossing Drilling horizontal bore hole for water main pipeline crossing below National Highway / State Highway / Canal by Pushing Method with allied works including providing and fixing of M.S. pipe with 406 microns thick inside epoxy and outside 25 Micron Zinc rich Primer, including getting permission from competent authority. All the statutory charges & other charges such as deposit, damage, insurance, NOC, etc. for laying pipeline below State Highway are to be paid by the contractor followed by successful restoration of the structure. For National Highway, State Highway and canal Crossings at different locations For 1626 mm dia crossing ULBMC
For 1422 mm dia crossing High level canal
For 1219 mm dia crossing NH & Railway
For 914 mm dia
For 610 mm dia
For 355 mm dia
Excavation for Welding Spot at all joints ( in addition to sand bedding) for avg 2.0m width
Providing and fixing 600 mm dia. 6.3 mm thick. MS Inspection Manhole / chamber at every 2.5 Km & on both side of zero velocity valves.
Designing, providing, erecting and commissioning of Surge Control Devices such as Zero Velocity Valves/ Surge Anticipation valve & control system Vacuum Breaker cum Air Cushion Valves for use as pipeline at PS-1, PS-2 & PS-3 including designing & constructing suitable R.C.C. structure/ chambers in M – 30 as per drawings or as per instruction by engineer in charge.
Constructing 2 m x 2 m size control cabin on field at remote locations. Approximate 105 nos.
Constructing Box type structure (BOX SIZE - (7.5x6)@Ch-17+760 (8 NOS. OF BOX)) on Mindhola river crossing Main pipe line.
Site grading and Gardening, Planting, with necessary civil work and Lighting with decorative pole in plot of PS-1.
Site grading and Gardening, Planting, with necessary civil work and Lighting with decorative pole in plot of PS-2.
Site grading and Gardening, Planting, with necessary civil work and Lighting with decorative pole in plot of PS-3.
Construction of office building with conference room at Vaghnera Village P.S. - 1 with all necessary works required for operation of project.
Construction of Energy Dissipation structure at the end of pipe for connection to pond including construction of headwall, wing wall, Endwall, pedestial for bellmouth, Pitching etc complete as per site condition For 1209 mm dia m Pipe.
Construction of Energy Dissipation structure at the end of pipe for connection to pond including construction of headwall, wing wall, Endwall, pedestial for bellmouth, Pitching etc complete as per site condition For 400 mm dia m Pipe.
Cost for formation Mandali on field to arrangemnet of distribution of irrigation water and its operation for 10 year. (Rs.1072/- per Hectare for 8338.2 Ha.)
Getting permission from concerned authority including Deposits, insurance,taxes,transportation ((0.5 Percent of estimate of pipeline))
Provision for gas line ,water supply line, telephone line, other utilities etc.(Lump sump (33 Percent of Item no.54))
Crop compensation for pipeline network in Kharif and Rabi season.
Item Description
Price Scheulde - B (Mechanical Works for All Pumping works) FIRE PUMP HOUSE PIPING & EQUIPMENTS Supply, installation, testing and commissioning of electric driven Main Fire Pump to deliver 97.2 m3/hr flowrate at 7.0 kg/sq.cm head and suitable for automatic operation and consisting of following, complete with accessories all as specified and directed by the engineer-in-charge. NOTE: [i] Horizontal type, single-stage, single suction, horizontal shaft type, end suction, volute type with top centreline discharge centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal, etc. conforming to IS 12469: 2019, suitable to deliver 97.2 m3/hr flowrate at 7.0 Kg/ sq. cm head [ii] Suitable HP squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, having IE3 efficiency and suitable for operation on 3- Ph, 415 V, 50 Hz AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class 'F' insulation, conforming to IS 12615: 2018 [iii] MS fabricated common base-plate, coupling, coupling guard, foundation bolts, etc. complete with accessories as required.
Supply, installation, testing and commissioning of diesel engine driven main fire pump to deliver 97.2 m3/hr flowrate at 7.0 kg/ sq.cm head and suitable for automatic operation and consisting of following, complete with accessories all as specified and directed by the engineer-in-charge. NOTE: [i] Horizontal type,single-stage, single suction, horizontal shaft type, end suction, volute type with top centreline discharge centrifugal pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal, etc. conforming to IS 12469: 2019, suitable to deliver 97.2 m3/hr flowrate at 7.0 kg /sq.cm head [ii] Suitable HP, 1800 RPM diesel engine, water cooled with radiator, conforming to IS 10002: 1981, complete with auto starting mechanism, 12/24 V electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour, etc. as required [iii] MS fabricated common base-plate, coupling, coupling guard, foundation bolts, etc. complete with accessories as required.
Bourdon type pressure gauge(150 mm dia) with gauge cock-range0-10 kg/sq.cm
Pressure Switch Pressure switch suitable for pressure range 0- 14 bar having die cast aluminium construction and SS sensing element with ball valve, fittings viz. unions, collars, reducers etc. for fire pumpsets complete all as specified and directed by the engineer-in-charge.
Fire red powder coated motor control center with aluminium busbar and weather proof enclosure (IP-54) AS specified in the technical bid & as per the relevent IS standard/ requirement of TAC and local fire service department.The rate shall be inclusive of the complete board including supply of all components hardwares,etc.including all connected civil works and cabling in cable trays from MCC to the pumps,pressure switches.the starting mechnism for the electric motor shall be as per STAR DELTA/DOL & MANUAL
Exhaust pipe 150 mm NB dia M.S 'B' class pipe with rockwool insulation & 24 SWG aluminium sheet
Piping in the pump house(Above ground) M.S ERW pipe conf.to IS-1239 part-1,heavy grade upto 150NB & IS 3589 for 200NB & above sizes having 6.35mm thickness including fittings. 200 mm NB dia
150 mm NB dia
Cast iron double flanged OS & Y TYPE GATE VALVE nut bolts & washers,flanges etc 150 mm NB dia
C.I wafer type lever operated butterfly valve conf. to IS-13095 PN-1.6 with fittings,flanges,nut,bolts & washers etc. MOC of the body & disc shall be CI as per IS-210 FG200,EPDM/neoprene seat,carbon steel(EN8) shaft and nylon/teflon bearing,valves exceeding 150mm dia shall be gear operated 150 mm NB dia
S & F of CL 150 rated ball valve, designed & manufactured as per IS 9890: 1981 and tested as per BS 6755-1, having floating type three piece design CS body, SS- 304 ball PTFE seal / packing / gasket, CS fastners and lever and screwed / socket weld end connection etc. with accessories complete all as specified and directed by the engineer-in-charge. 25 mm NB dia
15 mm NB dia
Supply, installation, testing and commissioning wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulated complete all as specified and directed by the engineer-in-charge. 150 mm NB dia
50 mm NB dia
150 mm NB, 4 way fire brigade inlet breeching having inbuilt non return valve with 4 nos.of 63mm GM instantaneous inlets for fire water tank
M.S. Air vessel tank pf 1.2 mts length & 400 mm diameter including bolt, nut & washer etc. complete all as specified and directed by engineer- in-charge.
FIRE HYDRANT SYSTEM Underground piping M.S ERW pipe conf. to IS-1239 part-1 heavy grade upto 150 mm NB & IS 3589 for 200NB & above sizes having 6.35mm thickness including fittings,150mm wide X 4mm thick wrapping & coating backfilling of the excavated sand and hydrostatic testing for 2 hours at 150 Percent of the syatem presuure 150 mm NB dia
Fire Hydrant stand post with landing valve Oblique type stainless steel single headed yard hydrant valve with 63mm female instantaneous outlet angled towards ground as per IS-5290-type A with flanges,nuts,bolts,washers etc.including 1.2 m high & 80mm dia standpost,pipe & bends.
Branch Pipe S & F branch pipe, conforming to IS 2871, having 63 mm NB instantaneous gunmetal inlet, made threaded outlet, 15 mm NB long nozzle, suitable for inter connection to hose pipe coupling complete all as specified and directed by the engineer-in-charge.
Fire Hose S & F non-percolating rubber reinforced lined RRL hose type- A 15 m long fire hose of 63 mm NB size, conforming to IS 636: 1988, rated for bursting pressure of 35.7 kg/cm² complete with gunmetal male & female coupling conforming to IS 903: 1993, bound and rivetted to the hose pipe with copper rivets and 1.5 mm² copper wire complete all as specified and directed by the engineer-in-charge.
Fire Hose cabinet S & F outdoor type lockable hose cabinet suitable to house 2 Nos. of 15 m RRL hose and 2 Nos. of branch nozzles, of size 750 mm (H) x 250 mm (L) x 600 mm (D), made of 18 gauge MS sheet with double door with 4 mm thick glass and door frame made of 16 gauge MS sheet painted two coats of fire red outside and brilliant white inside over a coat of primer, having "HOSE CABINET NO." painted on the inner face of the glass in 50 mm size block letter, including fixing on angle iron frame of size 40 mm X 6 mm & the cost of break glass box containing the key of the cabinet complete all as specified and directed by the engineer-in-charge.
PORTABLE FIRE EXTINGUISHERS S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. (1 No. at entry/exit of each floor)
S & F of 4.5 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. (2 Nos. at entry / exit of each floor & 1 No. in lift machine room)
Warning Sign of size 300 mm X 150 mm reading 'EXIT' in 12.5 mm block letters in Green and white background, properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level
S & F Galvanized mild steel Fire Sand bucket (FILLED WITH DRY SAND) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket complete as specified and directed by the engineer-in-charge.
Item Description
Price Schedule C: Mechanical Works for pumping Station - 1 for Vaghnera Village PUMP-MOTOR COMPLETE SET PUMP-MOTOR COMPLETE SET FOR PS 1 (i) Pump Type:VT Pump Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of Vertical Turbine (VT) Pumps of required capacity (Flow - Q) & Head (H) with suitable motor. Pump having S.S. Impeller with sealing ring, Bell Mouth & Bowl (of 1.5 to 2 Percent Ni C.I.), Line Shaft / Pump Shaft of S.S. with Forced Water Lubrication System, Pump-motor Coupling, Anti Friction Type Thrust Bearing, M.S. flanged Column Pipe assembly (having length suitable for the site condition), Suction Strainer - SS, Discharge Head with Base Frame. Pump having following parameters, along with others, complete as per relevant IS, Data Sheet & Tender Specifications. Flow (m3/hr) :- 3240 Head (Meter):- 136 Motor Rating :- 1600 Pump / Motor RPM:-As per Vendor's Design Pump: Nos. of Stages:-As per Vendor's Design Pump - Motor Quantity Set.:- 6 Pump Type:VT Column Length (Approx. - Meters):- 9 (ii) MOTOR (cost is Included in 1 above) Motor Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of Verticle solid / hollow shaft (as per vendor's design), Squirrel Cage, Induction Motor suitable for the above application and above type of pumps, to be operated on 3 Ph, 6.6 kV (+/- 10 Percent), 50 Hz (+/- 5 Percent), AC power supply, designed for continuous duty - S1, with anti condensation heater, provision for the monitoring of motor winding & bearing temperatures & having features of "Alarm" at temperature "High" & "Trip" at temperature "Very High", with suitable type of cooling, etc. complete as per relevent IS, Data-sheet & Tender Specifications. The motor shall be converter grade motor suitable for operation with a solid state power supply consisting of an adjustable frequency inverter for speed control and shall comply to IEC-60034-25 and relevant part of IS/IEC-60079.
DELIVERY & HEADER PIPES WITH SPECIALS Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of MS pipes of below mentioned sizes for Pump discharge & header application, confirming to relevent specified standard with bevel ends with inside lining of Food Grade Epoxy Paint (with 406 microns DFT) & out side coating of (i) Zinc rich epoxy primer & Coal Tar Epoxy paint (with 200 microns Total DFT) for Pump-house & (ii) 3 LPE coating for header piping, including bends, tees, reducers, flanges, ball valves for air venting & all types of specials to suit the site requirement & its installation, hydro-testing etc., complete as per relevent standards, data-sheet & specifications. Pump Delivery Pipes & Filings - Length (pipes of following sizes) Outside Diameter (mm) 813 Thickness (mm):-7.1 Delivery Pipe Material: MS
(ii) Ball Valve as Air Vent (SS Material) Size: 80 MM
(iii) Header Pipes & Filings - Length (pipes of following sizes) Outside Diameter (mm) 1626 Thickness (mm):- 14.2 Header Pipe Material: MS
PUMP DISCHARGE VALVES FOR PS-1 BFV Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of ISI mark Butterfly Valve with flanged ends as per following size, rating, mode of operation & Material of Construction (MOC) of valve body conforming to IS 13095 with SS 410 shaft, Nitrile / EPDM seal, SS 304 Seat Rings & Clamping Rings with all carbon steel fasteners, etc. complete as per Data-sheet & Specifications. Size : 800 mm Rating : 2.0 PN Mode of operation :-Motorised Material (MOC):-Ductile Iron
(ii) By-pass to BFV (Sluice Valve) Size : 100mm Rating : 2.0 PN Mode of operation:-Hand Operated Material (MOC):-Ductile Iron
(iii) NON RETURN VALVE (NRV) NRV - Type DPCV Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of Dual Plate Check Valve (as NRV) with flanged ends of following sizes, rating & body material conforming to API 594 / 598, SS 304 Seat Rings with all necessary hardwares, complete as per data-sheet & specification. Size : 800 mm Rating : 2.0 PN Body Material (MOC):-Ductile Iron
(iv) By-pass to NRV (Sluice Valve) Size : 100mm Rating : 2.0 PN Mode of operation:-Hand Operated Material (MOC):-Ductile Iron
EXPANSION BELLOWS FOR PS-1 Description: Supply, delivery, installation, testing and commissioning of Stainless Steel Expansion Bellows of corrugated design of following sizes & ratings as per EJMA standard, with flanged ends having 15 mm axial movement, 300 mm overall length, with tie rods, nuts, etc. complete as per data-sheet & specifications. On Pump Discharge Pipeline Size : 800 mm Rating : 2.0 PN
(ii) On Discharge Headers Size : 1600 mm Rating : 2.0PN
HEADER LINE VALVES BFV For PS 1 Description: Supply, delivery, installation, testing and commissioning of ISI mark Butterfly Valve with flanged ends as per following size, rating, mode of operation & Material of Construction (MOC) of valve body conforming to IS 13095 with SS 410 shaft, Nitrile / EPDM seal, SS 304 Seat Rings & Clamping Rings with all carbon steel fasteners, etc. complete as per Data-sheet & Specifications Size : 1600 mm Rating : 2.0PN Mode of operation:-Motorised Material (MOC):-Ductile Iron
(ii) By-pass to BFV (Sluice Valve) Size : 250 mm Rating : 2.0PN Mode of operation:-Hand Operated Material (MOC):-Ductile Iron
AIR VALVES Type Temper Proof Kinetic Double Acting Description: Supply, delivery, installation, testing and commissioning of Temper proof Air valves (as per AWWA C 512) with an isolation sluice valve. Air Valves with SS 304 Float, gun metal / bras - nozzle of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. incl lowering ,laying & jointing in position air valves incl. cost of all labour , jointing material incl nut bolts and giving satisfactory hydraulic testing etc. complete as per data sheet & specifications Size : 200 mm Rating : 2.0PN Material (MOC):-Ductile Iron
SUMP DEWATERING PUMP SETS (Submersible, Non-clog, Vertical Type) Supply, delivery, installation, testing and commissioning of Non- clog Submersible Vertical Pump with discharge (Flow - Q) & head (H) suitable with site condition and Impeller of SS CF 8M, Casing of C.I., Shaft of SS 410 or SS 316, suitable for 3 phase, 415 volts, 50 hz, AC supply, submersible motor having TEFC enclosure class - F insulation and IP - 68 protection. The Pump shall be operated at suitable RPM (As per Vendor's design). The scope shall include all the accessories, i.e. Automatic Coupling Device, Guide Pipe, Chain with Shackle, Flat Submersible Cable up to Starter Panel through suitable size of G. I. Pipe (Approx. 30 meter, 3 Core, Flat Copper Cable for each pump) with necessary electrical connections with the starter panel. Pump and all parts as per relevent standard, data sheets & tender specifications. Flow (m3/hr) :-180 Head (Meter):-20 Motor Rating : 25HP Quantity - 2Nos. Purpose Water Sump De-watering
EOT CRANE WITH HOIST Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of fully electrically operated travelling crane with cross travel, long travel & electrically operated hoist with suitable rating motors having IP 55, control panel with hoisting motor, wire rope drum, wire rope, rope sheaves, hooks, spring set, friction shoe type electromagnetic brakes for hoisting and travel motions, pendant control with cable, flexible trailing cable, limit switches, travel stops, earthing terminals and other accessories etc. complete as per data-sheet & specifications and tested to 25 Percent overload Capacity :40 Ton Span: 18mtr Lift: 34 Meter Runway: Estimated meters:-As per approved drg
TOOLS & TACKLES
SPARES FOR O & M
Item Description
Price Schedule C: Mechanical Works for pumping Station - 2 for Kavla Village PUMP-MOTOR COMPLETE SET PUMP-MOTOR COMPLETE SET FOR PS 1 (i) Pump Type:VT Pump Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of Vertical Turbine (VT) Pumps of required capacity (Flow - Q) & Head (H) with suitable motor. Pump having S.S. Impeller with sealing ring, Bell Mouth & Bowl (of 1.5 to 2 Percent Ni C.I.), Line Shaft / Pump Shaft of S.S. with Forced Water Lubrication System, Pump-motor Coupling, Anti Friction Type Thrust Bearing, M.S. flanged Column Pipe assembly (having length suitable for the site condition), Suction Strainer - SS, Discharge Head with Base Frame. Pump having following parameters, along with others, complete as per relevant IS, Data Sheet & Tender Specifications. Flow (m3/hr) :- 3240 Head (Meter):- 136 Motor Rating :- 1600 Pump / Motor RPM:-As per Vendor's Design Pump: Nos. of Stages:-As per Vendor's Design Pump - Motor Quantity Set.:- 6 Pump Type:VT Column Length (Approx. - Meters):- 9 (ii) MOTOR (cost is Included in 1 above) Motor Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of Verticle solid / hollow shaft (as per vendor's design), Squirrel Cage, Induction Motor suitable for the above application and above type of pumps, to be operated on 3 Ph, 6.6 kV (+/- 10 Percent), 50 Hz (+/- 5 Percent), AC power supply, designed for continuous duty - S1, with anti condensation heater, provision for the monitoring of motor winding & bearing temperatures & having features of "Alarm" at temperature "High" & "Trip" at temperature "Very High", with suitable type of cooling, etc. complete as per relevent IS, Data-sheet & Tender Specifications. The motor shall be converter grade motor suitable for operation with a solid state power supply consisting of an adjustable frequency inverter for speed control and shall comply to IEC-60034-25 and relevant part of IS/IEC-60079.
DELIVERY & HEADER PIPES WITH SPECIALS Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of MS pipes of below mentioned sizes for Pump discharge & header application, confirming to relevent specified standard with bevel ends with inside lining of Food Grade Epoxy Paint (with 406 microns DFT) & out side coating of (i) Zinc rich epoxy primer & Coal Tar Epoxy paint (with 200 microns Total DFT) for Pump-house & (ii) 3 LPE coating for header piping, including bends, tees, reducers, flanges, ball valves for air venting & all types of specials to suit the site requirement & its installation, hydro-testing etc., complete as per relevent standards, data-sheet & specifications. Pump Delivery Pipes & Filings - Length (pipes of following sizes) Outside Diameter (mm) 914 Thickness (mm):-8 Delivery Pipe Material: MS
(ii) Ball Valve as Air Vent (SS Material) Size: 80 MM
Header Pipes & Filings - Length (pipes of following sizes) Outside Diameter (mm) 1422 Thickness (mm):- 12.5 Header Pipe Material: MS
PUMP DISCHARGE VALVES FOR PS-2 BFV Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of ISI mark Butterfly Valve with flanged ends as per following size, rating, mode of operation & Material of Construction (MOC) of valve body conforming to IS 13095 with SS 410 shaft, Nitrile / EPDM seal, SS 304 Seat Rings & Clamping Rings with all carbon steel fasteners, etc. complete as per Data-sheet & Specifications. Size : 900 mm Rating : 1.6 PN Mode of operation :-Motorised Material (MOC):-Ductile Iron
By-pass to BFV (Sluice Valve) Size : 100mm Rating : 1.6 PN Mode of operation:-Hand Operated Material (MOC):-Ductile Iron
NON RETURN VALVE (NRV) NRV - Type DPCV Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of Dual Plate Check Valve (as NRV) with flanged ends of following sizes, rating & body material conforming to API 594 / 598, SS 304 Seat Rings with all necessary hardwares, complete as per data-sheet & specification. Size : 900 mm Rating : 1.6 PN Body Material (MOC):-Ductile Iron
By-pass to NRV (Sluice Valve) Size : 100mm Rating : 1.6 PN Mode of operation:-Hand Operated Material (MOC):-Ductile Iron
EXPANSION BELLOWS FOR PS-2 Description: Supply, delivery, installation, testing and commissioning of Stainless Steel Expansion Bellows of corrugated design of following sizes & ratings as per EJMA standard, with flanged ends having 15 mm axial movement, 300 mm overall length, with tie rods, nuts, etc. complete as per data-sheet & specifications. On Pump Discharge Pipeline Size : 900 mm Rating : 1.6 PN
On Discharge Headers Size : 1400 mm Rating : 1.6PN
HEADER LINE VALVES BFV For PS 2 Description: Supply, delivery, installation, testing and commissioning of ISI mark Butterfly Valve with flanged ends as per following size, rating, mode of operation & Material of Construction (MOC) of valve body conforming to IS 13095 with SS 410 shaft, Nitrile / EPDM seal, SS 304 Seat Rings & Clamping Rings with all carbon steel fasteners, etc. complete as per Data-sheet & Specifications Size : 1400 mm Rating : 1.6PN Mode of operation:-Motorised Material (MOC):-Ductile Iron
By-pass to BFV (Sluice Valve) Size : 250 mm Rating :1.6 PN Mode of operation:-Hand Operated Material (MOC):-Ductile Iron
AIR VALVES Type Temper Proof Kinetic Double Acting Description: Supply, delivery, installation, testing and commissioning of Temper proof Air valves (as per AWWA C 512) with an isolation sluice valve. Air Valves with SS 304 Float, gun metal / bras - nozzle of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. incl lowering ,laying & jointing in position air valves incl. cost of all labour , jointing material incl nut bolts and giving satisfactory hydraulic testing etc. complete as per data sheet & specifications Size : 200 mm Rating : 1.6PN Material (MOC):-Ductile Iron
SUMP DEWATERING PUMP SETS (Submersible, Non-clog, Vertical Type) Supply, delivery, installation, testing and commissioning of Non- clog Submersible Vertical Pump with discharge (Flow - Q) & head (H) suitable with site condition and Impeller of SS CF 8M, Casing of C.I., Shaft of SS 410 or SS 316, suitable for 3 phase, 415 volts, 50 hz, AC supply, submersible motor having TEFC enclosure class - F insulation and IP - 68 protection. The Pump shall be operated at suitable RPM (As per Vendor's design). The scope shall include all the accessories, i.e. Automatic Coupling Device, Guide Pipe, Chain with Shackle, Flat Submersible Cable up to Starter Panel through suitable size of G. I. Pipe (Approx. 30 meter, 3 Core, Flat Copper Cable for each pump) with necessary electrical connections with the starter panel. Pump and all parts as per relevent standard, data sheets & tender specifications. Flow (m3/hr) :-180 Head (Meter):-20 Motor Rating : 25HP Quantity - 2Nos. Purpose Water Sump De-watering
EOT CRANE WITH HOIST Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of fully electrically operated travelling crane with cross travel, long travel & electrically operated hoist with suitable rating motors having IP 55, control panel with hoisting motor, wire rope drum, wire rope, rope sheaves, hooks, spring set, friction shoe type electromagnetic brakes for hoisting and travel motions, pendant control with cable, flexible trailing cable, limit switches, travel stops, earthing terminals and other accessories etc. complete as per data-sheet & specifications and tested to 25 Percent overload Capacity : 30 Ton Span: 19 mtr Lift: 17 Meter Runway: Estimated :-as per approved drg
TOOLS & TACKLES
SPARES FOR O & M
Item Description
Price Schedule C: Mechanical Works for pumping Station - 3 for Kanala Village PUMP-MOTOR COMPLETE SET PUMP-MOTOR COMPLETE SET FOR PS 3 (i) Pump Type:VT Pump Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of Vertical Turbine (VT) Pumps of required capacity (Flow - Q) & Head (H) with suitable motor. Pump having S.S. Impeller with sealing ring, Bell Mouth & Bowl (of 1.5 to 2 Percent Ni C.I.), Line Shaft / Pump Shaft of S.S. with Forced Water Lubrication System, Pump-motor Coupling, Anti Friction Type Thrust Bearing, M.S. flanged Column Pipe assembly (having length suitable for the site condition), Suction Strainer - SS, Discharge Head with Base Frame. Pump having following parameters, along with others, complete as per relevant IS, Data Sheet & Tender Specifications. Flow (m3/hr) :- 1800 Head (Meter):- 57 Motor Rating :- 400 KW Pump / Motor RPM:-As per Vendor's Design Pump: Nos. of Stages:-As per Vendor's Design Pump - Motor Quantity Set.:- 4 Pump Type:VT Column Length (Approx. - Meters):- 8.8 (ii) MOTOR (cost is Included in 1 above) Motor Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of Verticle solid / hollow shaft (as per vendor's design), Squirrel Cage, Induction Motor suitable for the above application and above type of pumps, to be operated on 3 Ph, 6.6 kV (+/- 10 Percent), 50 Hz (+/- 5 Percent), AC power supply, designed for continuous duty - S1, with anti condensation heater, provision for the monitoring of motor winding & bearing temperatures & having features of "Alarm" at temperature "High" & "Trip" at temperature "Very High", with suitable type of cooling, etc. complete as per relevent IS, Data-sheet & Tender Specifications. The motor shall be converter grade motor suitable for operation with a solid state power supply consisting of an adjustable frequency inverter for speed control and shall comply to IEC-60034-25 and relevant part of IS/IEC-60079.
DELIVERY & HEADER PIPES WITH SPECIALS Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of MS pipes of below mentioned sizes for Pump discharge & header application, confirming to relevent specified standard with bevel ends with inside lining of Food Grade Epoxy Paint (with 406 microns DFT) & out side coating of (i) Zinc rich epoxy primer & Coal Tar Epoxy paint (with 200 microns Total DFT) for Pump-house & (ii) 3 LPE coating for header piping, including bends, tees, reducers, flanges, ball valves for air venting & all types of specials to suit the site requirement & its installation, hydro-testing etc., complete as per relevent standards, data-sheet & specifications. Pump Delivery Pipes & Filings - Length (pipes of following sizes) Outside Diameter (mm) 610 Thickness (mm):-5.8 Delivery Pipe Material: MS
Ball Valve as Air Vent (SS Material) Size: 80 MM
Header Pipes & Filings - Length (pipes of following sizes) Outside Diameter (mm) 1016 Thickness (mm):- 8.8 Header Pipe Material:MS
PUMP DISCHARGE VALVES FOR PS-3 BFV Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of ISI mark Butterfly Valve with flanged ends as per following size, rating, mode of operation & Material of Construction (MOC) of valve body conforming to IS 13095 with SS 410 shaft, Nitrile / EPDM seal, SS 304 Seat Rings & Clamping Rings with all carbon steel fasteners, etc. complete as per Data-sheet & Specifications. Size : 600 mm Rating : 1.0 PN Mode of operation :-Motorised Material (MOC):-Ductile Iron
By-pass to BFV (Sluice Valve) Size : 100mm Rating :1.0 PN Mode of operation:-Hand Operated Material (MOC):-Ductile Iron
NON RETURN VALVE (NRV} NRV - Type DPCV Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of Dual Plate Check Valve (as NRV) with flanged ends of following sizes, rating & body material conforming to API 594 / 598, SS 304 Seat Rings with all necessary hardwares, complete as per data-sheet & specification. Size : 600 mm Rating : 1.0 PN Body Material (MOC):-Ductile Iron
By-pass to NRV (Sluice Valve) Size : 100mm Rating : 1.0PN Mode of operation:-Hand Operated Material (MOC):-Ductile Iron
EXPANSION BELLOWS FOR PS-3 Description: Supply, delivery, installation, testing and commissioning of Stainless Steel Expansion Bellows of corrugated design of following sizes & ratings as per EJMA standard, with flanged ends having 15 mm axial movement, 300 mm overall length, with tie rods, nuts, etc. complete as per data-sheet & specifications. On Pump Discharge Pipeline Size : 600 mm Rating : 1.0 PN
On Discharge Headers Size : 1000 mm Rating : 1.0PN
HEADER LINE VALVES BFV For PS- 3 Description: Supply, delivery, installation, testing and commissioning of ISI mark Butterfly Valve with flanged ends as per following size, rating, mode of operation & Material of Construction (MOC) of valve body conforming to IS 13095 with SS 410 shaft, Nitrile / EPDM seal, SS 304 Seat Rings & Clamping Rings with all carbon steel fasteners, etc. complete as per Data-sheet & Specifications Size : 1000 mm Rating : 1.0PN Mode of operation:-Motorised Material (MOC):-Ductile Iron
By-pass to BFV (Sluice Valve) Size : 250 mm Rating : 1.0PN Mode of operation:-Hand Operated Material (MOC):-Ductile Iron
AIR VALVES Type Temper Proof Kinetic Double Acting Description: Supply, delivery, installation, testing and commissioning of Temper proof Air valves (as per AWWA C 512) with an isolation sluice valve. Air Valves with SS 304 Float, gun metal / bras - nozzle of approved make & quality of following class and diameter including all taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading, conveyance to departmental stores, stacking etc. complete. incl lowering ,laying & jointing in position air valves incl. cost of all labour , jointing material incl nut bolts and giving satisfactory hydraulic testing etc. complete as per data sheet & specifications Size : 200 mm Rating : 1.0PN Material (MOC):-Ductile Iron
SUMP DEWATERING PUMP SETS (Submersible, Non-clog, Vertical Type) Supply, delivery, installation, testing and commissioning of Non- clog Submersible Vertical Pump with discharge (Flow - Q) & head (H) suitable with site condition and Impeller of SS CF 8M, Casing of C.I., Shaft of SS 410 or SS 316, suitable for 3 phase, 415 volts, 50 hz, AC supply, submersible motor having TEFC enclosure class - F insulation and IP - 68 protection. The Pump shall be operated at suitable RPM (As per Vendor's design). The scope shall include all the accessories, i.e. Automatic Coupling Device, Guide Pipe, Chain with Shackle, Flat Submersible Cable up to Starter Panel through suitable size of G. I. Pipe (Approx. 30 meter, 3 Core, Flat Copper Cable for each pump) with necessary electrical connections with the starter panel. Pump and all parts as per relevent standard, data sheets & tender specifications. Flow (m3/hr) :-180 Head (Meter):-20 Motor Rating : 25HP Quantity - 2Nos. Purpose Water Sump De-watering
EOT CRANE WITH HOIST Description: Design, Manufacturing. Supply, Delivery, Installation, Testing and Commissioning of fully electrically operated travelling crane with cross travel, long travel & electrically operated hoist with suitable rating motors having IP 55, control panel with hoisting motor, wire rope drum, wire rope, rope sheaves, hooks, spring set, friction shoe type electromagnetic brakes for hoisting and travel motions, pendant control with cable, flexible trailing cable, limit switches, travel stops, earthing terminals and other accessories etc. complete as per data-sheet & specifications and tested to 25 Percent overload Capacity : 15 Ton Span: 15 mtr Lift: 17 Meter Runway: Estimated :-as per approved drg
TOOLS & TACKLES
SPARES FOR O & M
Item Description
6. Price Schedule – D : Overhead Transmission line works for Pumping stations 1 at Vaghnera Village 66kv Over head transmission line The turn key work of Design, Engineering, procurement, erection & commissioning of 66kV single Circuit transmission lines are included in the scope of the Bidder. Procurement of raw materials like steel, zinc etc. required for fabrication and galvanizing, Inspection of raw steel and Fabrication , Galvanizing, inspection at manufacturer’s works and supply of all types of 66 KV S/C Transmission tower materials suitable for “ACSR Panther “ conductor as per the GETCO’s approved design/ drawing including approved quality bolt nuts ( 5.6 class), pack washers, spring washer & accessories, phase plate, number plate, circuit identification plate, anti climbing devices etc. This also includes the extension portion above six meter extension as per line requirement, design and supply including foundation design thereof with no extra cost to GETCO Procurement and supply of earthing material for pipe type and counter poise type earthing as per the GETCO’s approved drawing/s including all materials Procurement and supply of ACSR Panther conductor, Earth wire 7/3.15mm, hardware & accessories for conductor and earth wire, Silicon rubber insulator/Anti-Fog Disc Insulators/ Plain Disc Insulators suitable for 66 KV (suspension & Tension type ), TMT bars and cement of 43 grades as per IS8112 of brand approved by GETCO for casting foundations for various type of towers as per drawings. Excavation for different types of foundations of various towers as per GETCO approved drawing and back filling with normal soil, erection of tower ,tack welding of bolt-nuts including supply and application of zinc rich primer and 2 coat of enamel paints for bottom most two panel ( up to 10Meter ) including special tower Insulator hoisting, stringing of conductor and earth wire including laying, jointing, jumpering and tree cutting of entire section for safe clearance including clearance towards right of way. Laisoning Work for the same.
6. Price Schedule – D : Overhead Transmission line works for Pumping stations 2 at Kavla Village 66kv Over head transmission line The turn key work of Design, Engineering, procurement, erection & commissioning of 66kV single Circuit transmission lines are included in the scope of the Bidder. Procurement of raw materials like steel, zinc etc. required for fabrication and galvanizing, Inspection of raw steel and Fabrication , Galvanizing, inspection at manufacturer’s works and supply of all types of 66 KV S/C Transmission tower materials suitable for “ACSR Panther “ conductor as per the GETCO’s approved design/ drawing including approved quality bolt nuts ( 5.6 class), pack washers, spring washer & accessories, phase plate, number plate, circuit identification plate, anti climbing devices etc. This also includes the extension portion above six meter extension as per line requirement, design and supply including foundation design thereof with no extra cost to GETCO Procurement and supply of earthing material for pipe type and counter poise type earthing as per the GETCO’s approved drawing/s including all materials Procurement and supply of ACSR Panther conductor, Earth wire 7/3.15mm, hardware & accessories for conductor and earth wire, Silicon rubber insulator/Anti-Fog Disc Insulators/ Plain Disc Insulators suitable for 66 KV (suspension & Tension type ), TMT bars and cement of 43 grades as per IS8112 of brand approved by GETCO for casting foundations for various type of towers as per drawings. Excavation for different types of foundations of various towers as per GETCO approved drawing and back filling with normal soil, erection of tower ,tack welding of bolt-nuts including supply and application of zinc rich primer and 2 coat of enamel paints for bottom most two panel ( up to 10Meter ) including special tower Insulator hoisting, stringing of conductor and earth wire including laying, jointing, jumpering and tree cutting of entire section for safe clearance including clearance towards right of way. Laisoning Work for the same.
6. Price Schedule – D : Overhead Transmission line works for Pumping stations 3 at Kanala Village 11 kv Over head transmission line The turn key work of Design, Engineering, procurement, erection & commissioning of 11kV single Circuit transmission lines are included in the scope of the Bidder. Procurement of Raw Material like Polymer Insulators, bolt nuts, pack washers, spring washer & accessories, phase plate, number plate, circuit identification plate, anti-climbing devices, Galvanizing Pole Structure, DOG AAAC Conductor etc. as per the Electricity Board ‘s Approved Design/Drawing . Procurement and supply of earthing material as per the Electricity Board’s approved drawing/s including all materials Laisoning Work for the same.
Item Description
Electrical works for Pumping station 1 at Vaghnera Village 66 kV Switch yard (a) Design, engineering, procurement, installation, testing and commissioning of Gapless type, Lightning Arresters, suitable for 66kV system voltage (b) Design, engineering, procurement, installation, testing and commissioning of 66kV, 1000 Amps, Double Break Manual Isolator with earth switch. (c) Design, engineering, procurement, installation, testing and commissioning of 66kV, 1000 Amps, Double Break Manual Isolator without earth switch. (d) Design, engineering, procurement, installation, testing and commissioning of 66kV, 630 Amp, SF6 - Circuit breaker. (e) Design, engineering, procurement, installation, testing and commissioning of 66kV Dead Tank Type CT having CT ratio as per immediate load requirement by client ,CL- 0.2S , 5VA, (For Tariff metering as per GETCO specification) (03 Nos) on incomer (f) Design, engineering, procurement, installation, testing and commissioning of 66kV Dead Tank Type CT having CT ratio 200/1,CL- 0.2S , 5VA, no. of cores-2, (For Tariff metering as per GETCO specification) (03 Nos) on incomer for full load. (g)Design, engineering, procurement, installation, testing and commissioning of 66kV Dead Tank Type CT having CT ratio 200/1,CL- 0.5S , 5VA, no. of cores-4, (03 Nos) on incomer (h)Design, engineering, procurement, installation, testing and commissioning of 66kV Dead Tank Type CT having CT ratio 150/1,CL- 0.5 ,15VA, no. of cores-4 (Transformer side),(06 Nos) (i)Design, engineering, procurement, installation, testing and commissioning of 66kV/√3 / 110/√3 / 110/√3 , CL- 0.2 S, 10VA ,No. of cores 2, , Potential Transformer.(For tariff metering as per GETCO) , Energy meter digital type (For tariff metering as per GETCO) (03 Nos.) on incomer (j)Design, engineering, procurement, installation, testing and commissioning of 66kV/√3 / 110/√3 / 110/√3 / 110/√3 No. of cores 3, Class,100VA, Potential Transformer.(03 Nos) on incomer (k)Design, engineering, procurement, installation, testing and commissioning of 66kV/√3 / 110/√3 / 110/√3 / 110/√3 No. of cores 3, Class,100VA, Potential Transformer. (For Bus PT) (l)Galvanized Steel structure for receiving 66 kV GEB and installation of CT, PT, Lighting Arrestors, Isolators with/without Earth switch, SF6 Circuit breaker in the 66 kV switchyard including all gentree structure, equipments structure and fencing. (m)Procurement & installation of ACSR Conductors / Clamps / Connectors, 66KV Bus post insulator, Tension insulator for 66KV switchyard for polluted atmosphere etc. complete as per specifications and as directed by the Engineer-in-Charge. (n)Design, engineering, procurement, installation, testing and commissioning of Earthing System-to be connected with equipments like power & auxiliary transformers, CTs-PTs,Isolators, breaker, lightning arrestors, galvanized structures etc. in the 66 KV switchyard as per switch yard tender drawing and tender specification. (o)Design ,engineering, procurement, installation, testing and commissioning of lightning protection system for protection of Electrical Equipment and human safety . (p)Design, engineering, procurement and installation of Cable tray ladder and perforated type and associated tees elbows and reducers including coupler plates etc., for systematic laying of power and control cables in trench. (q) All civil works necessary for switch yard (r) Design, engineering, procurement and installation necessary fire & safety arrangement for switchyard equipments as per latest fire & safety norm . (s) Necessary approval from government Inspecting authority before charging of switchyard
Power Transformer Design, engineering, procurement, installation, testing and commissioning of Power Transformers 66 KV/ 6.9 KV, 12500 KVA, Dyn11, ONAN, +10 Percent to –10 Percent range in step of 1.25 Percent with OLTC, RTCC Panel, temperature rise in oil/winding 50/55 c above ambient temperature with neutral brought out connected to provide separate earthing including terminal arrangement bushing on HT side and cable box on LT side as per requirement with standard fittings confirming to IS 2026 & its latest amendment accessories complete with fire & safety norms & No load - Load losses as per CBIP manual. Earthing of transformer shall be as per IS 3043 & tender specification.
Neutral grounding resistors Design, engineering, procurement, installation,testing and commissioning of 6.6 KV 1094.76 Amps, 3.4848 Ohms,10 Secs. Neutral Grounding Resistors as per IS IEEE-32 & tender specification.
66kV Line & transformer relay control panel Design, engineering, procurement, installation, testing and commissioning of 66 KV H.T line & transformer as per latest applicable standard & tender specification . (a) 630 Amp SF6 breaker, 200/1 Amp CT ratio : 01 No. For line control (b) 630 Amp ,SF6 breaker , 150/1 Amp. CT ratio : 02 Nos For transformer control (c) SF6 confirming as per I.S. for use on 66 KV, 3 phase, 50Hz. unearthed A.C. supply system having short circuit current capacity of 25KA for 3sec (d) C&R panel comprising of numerical relays, differential protection relay, over current, earth fault relays, Under voltage, Over voltage and semaphore etc. (e) All panel shall be suitable for PLC -SCADA compatibility
6.6kV Panel Design, engineering, procurement, installation, testing and commissioning of 6.6 KV VCB H.T panel as per latest applicable standard IS -3427 & IS-13947 etc. & tender specification & SLD. (a) 1600 Amp ,EDO type, draw out VCB breakers : 02 nos as Incomer, CT : 1400/1 Amp. (b) 1600 Amp , EDO type, draw out VCB breakers : 01 nos, as bus coupler, CT : 1400/1 Amp. (c) Out going feeders : 630 Amp, EDO type, draw out VCB breakers : 06 Nos for 1600 KW motor feeder, 02 Nos. for Auxiliary transformer control, 02 Nos. Bus PT,2 No of Spare (d) Electrical closing coil and 02 Nos.Tripping Coil operating on 110V DC supply (e) Numerical relays with RS 485 Compability as per specification (f) Digital MFM with RS 485 Compability and including V, I, PF, KW, KWH etc. (g) Analog ammeter (h) Cubical fabricated from 2 mm CRCA sheet steel free standing, floor mounted, complete with temperature scanners, all associated equipments & accessories as pe single line diagram & tender specification etc. (i) Provide the motor winding & DE & NDE bearing temperature monitoring display with HI alarm HI-HI trip on front door of the panel with annunciation window & hooter. (j) 6.6KV Earthing truck ( Bus side & Cable side) (k) All feeder shall be suitable for PLC-SCADA compatible
Aux Transformer Design, engineering, procurement, installation, testing and commissioning of approved make oil immersed naturally ONAN cooled, double wound, core type indoor / outdoor copper wound 6.6KV/ 433V , DYN11 step down transformer of 500 KVA , operating on 3 phase, 50 Hz 4 wire & neutral earthed system complete with details specified in tender specification & datasheet. Auxiliary transformer complying with I.S.1180 standards. OFF load tap changing range +10 to -10 & in steps 2.5 Percent on H.V and L.V. for variation should be provided. The H.V. shall be connected Delta & Secondary with star connection. Earthing of transformer shall be as per IS 3043 & tender specification.
HT VFD panel for 6.6KV , 1600KW motors Design, engineering, procurement, installation, testing and commissioning of HT VFD Panel suitable for 1600 KW squirrel cage induction motor, 6.6 KV, 3 phase, 50 Hz with built in bypass terminal for pump control application as per tender specification. Harmonics at the supply side of the drive system at primary of the main input transformer shall be restricted within the maximum allowable levels of current and voltage distortion as per recommendations in the latest edition of IEEE-519.
LT PMCC Design, engineering, procurement, installation, testing and commissioning of MCC panel with totally enclosed type as per IS: 2147 & IS-8623, operation on three phase,415V, 50Hz,neutral effectively grounded, IP 55, with instrument compartments indicating lamps, control contactors as per IS: 13947,relays and control fuses air insulated . Incoming & Outgoing feeder details shall be as per Single line diagram & tender specifications. 800 Amp. EDO type, draw out ACB breakers as incomer feeder (2 Nos) , 800 Amp. EDO type, draw out ACB breakers Bus coupler (01 No) Outgoing feeder with S/D starter , Soft starter, DOL starter feeder & TPN MCCB/MCB etc. as per SLD Multifunction meter with RS 485 Compability with PLC-SCADA. Input Voltage- 3 phase 415 V (+/- 10 Percent) Input Frequency - 50 Hz (+/- 5 Percent) Starter Protection - S/C,u/Phase unbalance, Phase failure Built in communication as per RS 485 Under Voltage release type 415V Earth Fault Release EF1 (10 Percent, 20Percent Ir) Door Inter Lock 110 V DC Control Supply Suitable for PLC -SCADA system.
HT Power Cables Supply, laying, testing & commissioning 6.6 / 6.6 kV (UE) grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part- 2) & IEC: 60502(Part-2) of following sizes: *6.6kV (UE) equal 11kV (E) 6.6KV (U/E) 3C X 300 Sq.mm , AL ,XLPE , armoured cable.
LT Power Cables & Bus Duct Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Copper/Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part-1) & IEC: 60502 (Part-1) of following sizes: (a) 1.1KV ,3.5C X 300 sq.mm. AL XLPE (b)415 LT MCC panel to ACDB, LDB & PBD,Outgoing Feeder (i) 1.1KV 3C X 2.5 Sq.mm Cu cable (ii) 1.1KV 4C X 6 Sq.mm Al cable (iii) 1.1KV , 4Cx10 Sq.mm Al , cable (iv) 1.1KV 3.5C X 70 Sq.mm AL cable
Cable Trays Supply , Installation, Testing and commissioning approved make Ladder/ Perforated C type cable tray. Made from pre- galvanized CR sheet steel. The cable tray should be bended as per IS 2062/1079 . with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.Galvanised Iron Cable Trays. Including necessary supports, welding, insert plates, etc. complete with necessary bends, tees gross, covers, reducer, cover attachment, adjustable elbow, connectors & y branch, barrier strips and supporting ,erection hardware and accessoseries.make as per detail engineering & tender specifications. (a) 150 mm wide (Channel size 75X15X2 mm & runner size 35X15X2 mm) GI ladder type cable tray with GI couplers plate & nut bolts (b) 300 mm wide (Channel size 75X15X2 mm & runner size 35X15X2 mm) GI ladder type cable tray with GI couplers plate & nut bolts (c) 750 mm wide (Channel size 75X15X2 mm & runner size 35X15X2 mm) GI ladder type cable tray with GI couplers plate & nut bolts (d) 150 mm wide X 35X2 mm thick GI perforated type cable tray with GI couplers plate & nut bolts (e)300 mm wide 35X2 mm thick GI perforated type cable tray with GI couplers plate & nut bolts
Providing EARTHING & Lighting protection for Pump house, Electrical penel room, Out side Pump house area & Switchyard area equipments including Earthing pits, Electrode, GI Strips, MS Strip as per IS 3043 & IEEE 80 & tender specifications.
EXTERNAL LIGHTING [A] Supply , Installation, Testing and commissioning approved make steel tubular pole ( swaged ) confirming to IS -2713 & tender specifications , Pole should be painted by one coat of Zinc comet primer and two coat of Aluminium/approved paint to be erected on/it existing foundation, the length of the poles are as mention below. 9.0 Mtrs long swaged steel tubular pole (a) pole as per IS code , plate for burial erection (b) suitable foundation (c) primer and PU paint on the pole (d) Street light pole base (e) Pole foundation with pole earthing of suitable size (f) Cable clamps (g) Pole junction box (h) Street light bracket [B] Supplying and erecting MNES certified LED STREET LIGHT fitting made from dia cast alluminium body ,transparent cover with following LED lights & accessories. Complete with tubular battery, inverter, charge controller with photo sensor switch & necessary wiring complete erected connected & commissioned in approved manner of 36 watt suitable for volatge range of 90 to 300 voltage , 50000 hours working life, IP-67 , suitable master box , 4KVA surge protection , THD less than 10 Perent ,EMC compliance,Short circuit proof , over voltage and under voltage protection. (Street light shall be suitable for solar operated)
{C] Supplying and erecting MNES certified LED FLOOD LIGHT fitting made from dia cast alluminium body ,transparent cover with following LED lights & accessories. Complete with tubular battery, inverter, charge controller with photo sensor switch & necessary wiring complete erected connected & commissioned in approved manner of 100 watt suitable for volatge range of 90 to 300 voltage , 50000 hours working life, IP-65 fullyu weather proof , suitable master box , EMC compliance,Short circuit proof , over voltage and under voltage protection.
Internal Lighting & other accessories of Pump house building Point wiring : ( Copper) Point wiring for Fan/ Light/Bell/ Primary point with 2 - 1.5 sq.mm (green ) both are of ISI marked 1.1 KV grade PVC insulated copper wires in exising pipe duly erected complete with 6 A Tissino type ISI marked flush type switch / bell push and accessories with earth continuity erected on polished wooden block / metal / PVC box covered with 3 mm thick laminated sheet for concealed wiring. Plug point ( 6 Amp) Single pole 16 Amp switch Single pole 6 amp & 16 Amp universal socket Conduicts & Pipe ( 25 mm) Maiins & wires 1.1KV garded FR PVC insulated ISI marked standard copper conductor wire of 2.5 Sq.mm
Supply erection of 1 X 40 watt T8 LED tublight with necessaries accessories suitable for 90 to 300 voltage variation, surface mounting , aluminium body, 25000 working hour ,suitable master box ,etc.
Supply erection of 1 X 12 watt LED down light with necessaries accessories suitable for 90 to 300 voltage variation, surface mounting , aluminium body, 30000 working hour ,suitable master box ,etc.
Providing & erecting of 1 X50 watt hi bay LED comprises die cast aluminium body with necessaries accessories suitable for 90 to 300 voltage variation, surface mounting , 30000 working hour ,suitable master box ,etc.
Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy & 30 cms. down rod erected with 24/0.2, 3 core flexible wire with earthing. [ Make shall be approved by Engineer in Charge]
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM 380 mm dia 900 RPM -Cat-II
Battery & Battery charger with DCDB Design, Engineering, procurement, Installation, Testing and commissioning of Battery and Battery charger 110 V , 300 AH sealed maintenance free battery ( Lead acid battery) for DC power with float and boost type battery charger and DC distribution boards enclosures of 2 mm thick, IP 55 protection, louvers complete as per applicable standard & tender specifications.
Lighting & power distribution Panel board Supply , Installation, Testing and commissioning approved make LDB & PBD with TPN phase segregated DB comprising of CRCA sheet steel, double door, powder coated with provision of FP MCB/Isolator/RCCB as modular incomer & SP MCB as outgoing , IP-54 protection 8 way -Metal door
SAFETY ACCESSORIES (a)Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50" diagonally size.
(b)Providing pair of rubber hand gloves.
(c)Supplying rubber matting of following 12 mm thickness as per IS:15652/IEC 61111
(d)Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
(e)Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook.
(f)Supplying & erecting floor mounting stand for keeping four nos.of FIRE buckets comprising 1500mm in length 900 mm height frame made out of Jomm x 30 mm x 4 mm angle iron with cross supports for legs,welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paints
(g)Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. [B] For 5.5 / 6.5 KG Capacity
(h)Supplying & erection D.C.P type fire extingusher for following capacity cartridge type with gun metal cap 150 gram CO2 gas catridge ,powder and brackets confirming to IS 2171 1985 and complete eracted with necessery clamps made from 50 x 6 mm MS (1)For 10 KG Capacity
[A] TEST EQUIPMENT [B] Electrical Mandatory Spare Parts
Item Description
Electrical works for Pumping station 2 at Kavla Village 66 kV Switch yard (a) Design, engineering, procurement, installation, testing and commissioning of Gapless type, Lightning Arresters, suitable for 66kV system voltage (b) Design, engineering, procurement, installation, testing and commissioning of 66kV, 1000 Amps, Double Break Manual Isolator with earth switch. (c) Design, engineering, procurement, installation, testing and commissioning of 66kV, 1000 Amps, Double Break Manual Isolator without earth switch. (d) Design, engineering, procurement, installation, testing and commissioning of 66kV, 630 Amp, SF6 - Circuit breaker. (e) Design, engineering, procurement, installation, testing and commissioning of 66kV Dead Tank Type CT having CT ratio as per immediate load requirement by client ,CL- 0.2S , 5VA, (For Tariff metering as per GETCO specification) (03 Nos) on incomer (f) Design, engineering, procurement, installation, testing and commissioning of 66kV Dead Tank Type CT having CT ratio 140/1,CL- 0.2S , 5VA, no. of cores-2, (For Tariff metering as per GETCO specification) (03 Nos) on incomer for full load. (g)Design, engineering, procurement, installation, testing and commissioning of 66kV Dead Tank Type CT having CT ratio 140/1,CL- 0.5S , 5VA, no. of cores-4, (03 Nos) on incomer (h)Design, engineering, procurement, installation, testing and commissioning of 66kV Dead Tank Type CT having CT ratio 70/1,CL- 0.5 ,15VA, no. of cores-4 (Transformer side),(06 Nos) (i)Design, engineering, procurement, installation, testing and commissioning of 66kV/√3 / 110/√3 / 110/√3 , CL- 0.2 S, 10VA ,No. of cores 2, , Potential Transformer.(For tariff metering as per GETCO) , Energy meter digital type (For tariff metering as per GETCO) (03 Nos.) on incomer (j)Design, engineering, procurement, installation, testing and commissioning of 66kV/√3 / 110/√3 / 110/√3 / 110/√3 No. of cores 3, Class,100VA, Potential Transformer.(03 Nos) on incomer (k)Design, engineering, procurement, installation, testing and commissioning of 66kV/√3 / 110/√3 / 110/√3 / 110/√3 No. of cores 3, Class,100VA, Potential Transformer. (For Bus PT) (l)Galvanized Steel structure for receiving 66 kV GEB and installation of CT, PT, Lighting Arrestors, Isolators with/without Earth switch, SF6 Circuit breaker in the 66 kV switchyard including all gentree structure, equipments structure and fencing. (m)Procurement & installation of ACSR Conductors / Clamps / Connectors, 66KV Bus post insulator, Tension insulator for 66KV switchyard for polluted atmosphere etc. complete as per specifications and as directed by the Engineer-in-Charge. (n)Design, engineering, procurement, installation, testing and commissioning of Earthing System-to be connected with equipments like power & auxiliary transformers, CTs-PTs,Isolators, breaker, lightning arrestors, galvanized structures etc. in the 66 KV switchyard as per switch yard tender drawing and tender specification. (o)Design ,engineering, procurement, installation, testing and commissioning of lightning protection system for protection of Electrical Equipment and human safety . (p)Design, engineering, procurement and installation of Cable tray ladder and perforated type and associated tees elbows and reducers including coupler plates etc., for systematic laying of power and control cables in trench. (q) All civil works necessary for switch yard (r) Design, engineering, procurement and installation necessary fire & safety arrangement for switchyard equipments as per latest fire & safety norm . (s) Necessary approval from government Inspecting authority before charging of switchyard
Power Transformer Design, engineering, procurement, installation, testing and commissioning of Power Transformers 66 KV/ 6.9 KV, 6300 KVA, Dyn11, ONAN, +10 Percent to –10 Percent range in step of 1.25 Percent with OLTC, RTCC Panel, temperature rise in oil/winding 50/55 c above ambient temperature with neutral brought out connected to provide separate earthing including terminal arrangement bushing on HT side and cable box on LT side as per requirement with standard fittings confirming to IS 2026 & its latest amendment accessories complete with fire & safety norms & No load - Load losses as per CBIP manual. Earthing of transformer shall be as per IS 3043 & tender specification.
Neutral grounding resistors Design, engineering, procurement, installation,testing and commissioning of 6.6 KV 551.76 Amps, 6.9142 Ohms,10 Secs. Neutral Grounding Resistors as per IS IEEE-32 & tender specification.
66kV Line & transformer relay control panel Design, engineering, procurement, installation, testing and commissioning of 66 KV H.T line & transformer as per latest applicable standard & tender specification . (a) 630 Amp SF6 breaker, 140/1 Amp CT ratio : 01 No. For line control (b) 630 Amp ,SF6 breaker , 70/1 Amp. CT ratio : 02 Nos For transformer control (c) SF6 confirming as per I.S. for use on 66 KV, 3 phase, 50Hz. unearthed A.C. supply system having short circuit current capacity of 25KA for 3sec (d) C&R panel comprising of numerical relays, differential protection relay, over current, earth fault relays, Under voltage, Over voltage and semaphore etc. (e) All panel shall be suitable for PLC -SCADA compatibility
6.6kV Panel Design, engineering, procurement, installation, testing and commissioning of 6.6 KV VCB H.T panel as per latest applicable standard IS -3427 & IS-13947 etc. & tender specification & SLD. (a) 1000 Amp ,EDO type, draw out VCB breakers : 02 nos as Incomer, CT : 700/1 Amp. (b) 1000 Amp , EDO type, draw out VCB breakers : 01 nos, as bus coupler, CT : 700/1 Amp. (c) Out going feeders : 630 Amp, EDO type, draw out VCB breakers : 04 Nos for 1200 KW motor feeder, 02 Nos. for Auxiliary transformer control, 02 Nos. Bus PT,02 Nos for Spare feeder (d) Electrical closing coil and 02 Nos.Tripping Coil operating on 110V DC supply (e) Numerical relays with RS 485 Compability as per specification (f) Digital MFM with RS 485 Compability and including V, I, PF, KW, KWH etc. (g) Analog ammeter (h) Cubical fabricated from 2 mm CRCA sheet steel free standing, floor mounted, complete with temperature scanners, all associated equipments & accessories as pe single line diagram & tender specification etc. (i) Provide the motor winding & DE & NDE bearing temperature monitoring display with HI alarm HI-HI trip on front door of the panel with annunciation window & hooter. (j) 6.6KV Earthing truck ( Bus side & Cable side) (k) All feeder shall be suitable for PLC-SCADA compatible
Aux Transformer Design, engineering, procurement, installation, testing and commissioning of approved make oil immersed naturally ONAN cooled, double wound, core type indoor / outdoor copper wound 6.6KV/ 433V , DYN11 step down transformer of 500 KVA , operating on 3 phase, 50 Hz 4 wire & neutral earthed system complete with details specified in tender specification & datasheet. Auxiliary transformer complying with I.S.1180 standards. OFF load tap changing range +10 to -10 & in steps 2.5 Percent on H.V and L.V. for variation should be provided. The H.V. shall be connected Delta & Secondary with star connection. Earthing of transformer shall be as per IS 3043 & tender specification.
HT VFD panel for 6.6KV , 1200KW motors Design, engineering, procurement, installation, testing and commissioning of HT VFD Panel suitable for 1200 KW squirrel cage induction motor, 6.6 KV, 3 phase, 50 Hz with built in bypass terminal for pump control application as per tender specification. Harmonics at the supply side of the drive system at primary of the main input transformer shall be restricted within the maximum allowable levels of current and voltage distortion as per recommendations in the latest edition of IEEE-519.
LT PMCC Design, engineering, procurement, installation, testing and commissioning of MCC panel with totally enclosed type as per IS 2147 & IS-8623, operation on three phase,415V, 50Hz,neutral effectively grounded, IP 55, with instrument compartments indicating lamps, control contactors as per IS 13947,relays and control fuses air insulated . Incoming & Outgoing feeder details shall be as per Single line diagram & tender specifications. 800 Amp. EDO type, draw out ACB breakers as incomer feeder (2 Nos) , 800 Amp. EDO type, draw out ACB breakers Bus coupler (01 No) Outgoing feeder with S/D starter , Soft starter, DOL starter feeder & TPN MCCB/MCB etc. as per SLD Multifunction meter with RS 485 Compability with PLC SCADA. Input Voltage- 3 phase 415 V (+/- 10 Percent) Input Frequency - 50 Hz (+/- 5 Percent) Starter Protection - S/C,u/Phase unbalance, Phase failureBuilt in communication as per RS 485 Under Voltage release type 415V Earth Fault Release EF1 (10 Percent, 20 Percent Ir) Door Inter Lock 110 V DC Control Supply Suitable for PLC -SCADA system
HT Power Cables Supply, laying, testing & commissioning 6.6 / 6.6 kV (UE) grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS 7098 (Part 2) & IEC 60502(Part 2) of following sizes *6.6 kV (UE) equal 11kV (E) 6.6KV (U/E) 3C X 300 Sq.mm , AL ,XLPE , armoured cable
LT Power Cables & Bus Duct Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Copper/Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS 7098 (Part 1) & IEC 60502 (Part 1) of following sizes (a) 1.1KV ,3.5C X 300 sq.mm. AL XLPE (b)415 LT MCC panel to ACDB, LDB & PBD,Outgoing Feeder (i) 1.1KV 3C X 2.5 Sq.mm Cu cable (ii) 1.1KV 4C X 6 Sq.mm Al cable (iii) 1.1KV , 4Cx10 Sq.mm Al cable (iv) 1.1KV 3.5C X 70 Sq. mm AL cable
Cable Trays Supply , Installation, Testing and commissioning approved make Ladder/ Perforated C type cable tray. Made from pre- galvanized CR sheet steel. The cable tray should be bended as per IS 2062/1079. with coupler plate / Fish plate and GI hardware like nut bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge. Galvanised Iron Cable Trays. Including necessary supports welding, insert plates, etc. complete with necessary bends, tees gross, covers, reducer, cover attachment, adjustable elbow, connectors & y branch, barrier strips and supporting ,erection hardware and accessoseries.make as per detail engineering & tender specifications. (a) 150 mm wide (Channel size 75X15X2 mm & runner size 35X15X2 mm) GI ladder type cable tray with GI couplers plate & nut bolts (b) 300 mm wide (Channel size 75X15X2 mm & runner size 35X15X2 mm) GI ladder type cable tray with GI couplers plate & nut bolts (c) 750 mm wide (Channel size 75X15X2 mm & runner size 35X15X2 mm) GI ladder type cable tray with GI couplers plate & nut bolts (d) 150 mm wide X 35X2 mm thick GI perforated type cable tray with GI couplers plate & nut bolts (e)300 mm wide 35X2 mm thick GI perforated type cable tray with GI couplers plate & nut bolts
Providing EARTHING & Lighting protection for Pump house, Electrical penel room, Out side Pump house area & Switchyard area equipments including Earthing pits, Electrode, GI Strips, MS Strip as per IS 3043 & IEEE 80 & tender specifications.
EXTERNAL LIGHTING [A] Supply , Installation, Testing and commissioning approved make steel tubular pole ( swaged ) confirming to IS -2713 & tender specifications , Pole should be painted by one coat of Zinc comet primer and two coat of Aluminium/approved paint to be erected on/it existing foundation, the length of the poles are as mention below. 9.0 Mtrs long swaged steel tubular pole (a) pole as per IS code , plate for burial erection (b) suitable foundation (c) primer and PU paint on the pole (d) Street light pole base (e) Pole foundation with pole earthing of suitable size (f) Cable clamps (g) Pole junction box (h) Street light bracket [B] Supplying and erecting MNES certified LED STREET LIGHT fitting made from dia cast alluminium body ,transparent cover with following LED lights & accessories. Complete with tubular battery, inverter, charge controller with photo sensor switch & necessary wiring complete erected connected & commissioned in approved manner of 36 watt suitable for volatge range of 90 to 300 voltage , 50000 hours working life, IP-67 , suitable master box , 4KVA surge protection , THD less than 10 Percent ,EMC compliance,Short circuit proof , over voltage and under voltage protection. (Street light shall be suitable for solar operated)
{C] Supplying and erecting MNES certified LED FLOOD LIGHT fitting made from dia cast alluminium body ,transparent cover with following LED lights & accessories. Complete with tubular battery, inverter, charge controller with photo sensor switch & necessary wiring complete erected connected & commissioned in approved manner of 100 watt suitable for volatge range of 90 to 300 voltage , 50000 hours working life, IP-65 fullyu weather proof , suitable master box , EMC compliance,Short circuit proof , over voltage and under voltage protection.
Internal Lighting & other accessories of Pump house building Point wiring ( Copper) Point wiring for Fan/ Light/Bell/ Primary point with 2 1.5 sq.mm (green ) both are of ISI marked 1.1 KV grade PVC insulated copper wires in exising pipe duly erected complete with 6 A Tissino type ISI marked flush type switch / bell push and accessories with earth continuity erected on polished wooden block / metal / PVC box covered with 3 mm thick laminated sheet for concealed wiring. Plug point ( 6 Amp) Single pole 16 Amp switch Single pole 6 amp & 16 Amp universal socket Conduicts & Pipe ( 25 mm) Maiins & wires 1.1KV garded FR PVC insulated ISI marked standard copper conductor wire of 2.5 Sq.mm
Supply erection of 1 X 40 watt T8 LED tublight with necessaries accessories suitable for 90 to 300 voltage variation, surface mounting , aluminium body, 25000 working hour ,suitable master box ,etc.
Supply erection of 1 X 12 watt LED down light with necessaries accessories suitable for 90 to 300 voltage variation, surface mounting , aluminium body, 30000 working hour ,suitable master box ,etc.
Providing & erecting of 1 X50 watt hi bay LED comprises die cast aluminium body with necessaries accessories suitable for 90 to 300 voltage variation, surface mounting , 30000 working hour ,suitable master box ,etc.
Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy & 30 cms. down rod erected with 24/0.2, 3 core flexible wire with earthing. [ Make shall be approved by Engineer in Charge]
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM 380 mm dia 900 RPM -Cat-II
Battery & Battery charger with DCDB Design, Engineering, procurement, Installation, Testing and commissioning of Battery and Battery charger 110 V , 300 AH sealed maintenance free battery ( Lead acid battery) for DC power with float and boost type battery charger and DC distribution boards enclosures of 2 mm thick, IP 55 protection, louvers complete as per applicable standard & tender specifications.
Lighting & power distribution Panel board Supply , Installation, Testing and commissioning approved make LDB & PBD with TPN phase segregated DB comprising of CRCA sheet steel, double door, powder coated with provision of FP MCB/Isolator/RCCB as modular incomer & SP MCB as outgoing , IP-54 protection 8 way -Metal door
SAFETY ACCESSORIES (a)Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50" diagonally size.
(b)Providing pair of rubber hand gloves.
(c)Supplying rubber matting of following 12 mm thickness as per IS:15652/IEC 61111
(d)Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
(e)Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook.
(f)Supplying & erecting floor mounting stand for keeping four nos.of FIRE buckets comprising 1500mm in length 900 mm height frame made out of Jomm x 30 mm x 4 mm angle iron with cross supports for legs,welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paints
(g)Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. [B] For 5.5 / 6.5 KG Capacity
(h)Supplying & erection D.C.P type fire extingusher for following capacity cartridge type with gun metal cap 150 gram CO2 gas catridge ,powder and brackets confirming to IS 2171 1985 and complete eracted with necessery clamps made from 50 x 6 mm MS (1)For 10 KG Capacity
[A] TEST EQUIPMENT [B] Electrical Mandatory Spare Parts
Item Description
Electrical works for Pumping station 3 at Kanala Village 11 kV Four Pole Structure Assembly: SITC of 11 kV double pole 9 meter high structure made of 6" X 3" 'I" section girder, 4" X 2" channels, clamps, nuts, bolts, stay wires including earthing system with following accessories duly connected with ACSR conductors as per approved drawing & in compliance with requirement of IEC. (a) 11 kV, 200 A drop out fuses with Synthetic Resin Bonded Paper (SRBP) tubes 2 Set (01 piece per phase / circuit). (b) 11 kV, 400 A G.O.D. switch complete with earth switch, insulators, operating handle with galvanised pipe, square bar: 2 Set. (c) 11 kV lightning arrestor with clamps: 3 Nos. (d) 11 kV Disc Insulators (70KN): 9 Nos. (e) 11 kV Pin Insulators (5KN): 6 Nos. (f) 20 mm dia. GI. Stay Set Complete: 2 Set
Power Transformer Design, engineering, procurement, installation, testing and commissioning of Power Transformers 11 KV/ 6.9 KV, 2000 KVA, Dyn11, ONAN, +10Percent to –10Percent range in step of 1.25Percent with OLTC, RTCC Panel, temperature rise in oil/winding 50/55 c above ambient temperature with neutral brought out connected to provide separate earthing including terminal arrangement bushing on HT side and cable box on LT side as per requirement with standard fittings confirming to IS 2026 & its latest amendment accessories complete with fire & safety norms & No load - Load losses as per CBIP manual. Earthing of transformer shall be as per IS 3043 & tender specification.
Neutral grounding resistors Design, engineering, procurement, installation,testing and commissioning of 6.6 KV 175.16 Amps, 21.78 Ohms,10 Secs. Neutral Grounding Resistors as per IS IEEE-32 & tender specification.
11kV Panel Design, engineering, procurement, installation, testing and commissioning of 11 KV VCB H.T panel as per latest applicable standard IS -3427 & IS-13947 etc. & tender specification & SLD. (a) 630 Amp ,EDO type, draw out VCB breakers 01 nos as Incomer, CT 250/1 Amp. (b) Out going feeders 630 Amp, EDO type, draw out VCB breakers 04 Nos. for Power & Auxiliary transformer control (c) Electrical closing coil and 02 Nos.Tripping Coil operating on 110V DC supply (d) Numerical relays with RS 485 Compability as per specification (e) Digital MFM with RS 485 Compability and including V, I, PF, KW, KWH etc. (f) Analog ammeter (g) Cubical fabricated from 2 mm CRCA sheet steel free standing, floor mounted, complete with temperature scanners, all associated equipments & accessories as pe single line diagram & tender specification etc. (h) Provide the motor winding & DE & NDE bearing temperature monitoring display with HI alarm HI-HI trip on front door of the panel with annunciation window & hooter. (i) 11KV Earthing truck ( Bus side & Cable side) (j) All feeder shall be suitable for PLC SCADA compatible.
6.6kV Panel Design, engineering, procurement, installation, testing and commissioning of 6.6 KV VCB H.T panel as per latest applicable standard IS -3427 & IS-13947 etc. & tender specification & SLD. (a) 630 Amp ,EDO type, draw out VCB breakers : 02 nos as Incomer, CT : 200/1 Amp. (b) 630 Amp , EDO type, draw out VCB breakers : 01 nos, as bus coupler, CT : 200/1 Amp. (c) Out going feeders : 630 Amp, EDO type, draw out VCB breakers : 04 Nos for 400 KW motor feeder,02 Nos. Bus PT,02 Nos for the Spare Feeder (d) Electrical closing coil and 02 Nos.Tripping Coil operating on 110V DC supply (e) Numerical relays with RS 485 Compability as per specification (f) Digital MFM with RS 485 Compability and including V, I, PF, KW, KWH etc. (g) Analog ammeter (h) Cubical fabricated from 2 mm CRCA sheet steel free standing, floor mounted, complete with temperature scanners, all associated equipments & accessories as pe single line diagram & tender specification etc. (i) Provide the motor winding & DE & NDE bearing temperature monitoring display with HI alarm HI-HI trip on front door of the panel with annunciation window & hooter. (j) 6.6KV Earthing truck ( Bus side & Cable side) (k) All feeder shall be suitable for PLC SCADA compatible
Aux Transformer Design, engineering, procurement, installation, testing and commissioning of approved make oil immersed naturally ONAN cooled, double wound, core type indoor / outdoor copper wound 11KV/ 433V , DYN11 step down transformer of 500 KVA , operating on 3 phase, 50 Hz 4 wire & neutral earthed system complete with details specified in tender specification & datasheet. Auxiliary transformer complying with I.S.1180 standards. OFF load tap changing range +10 to -10 & in steps 2.5 Percent on H.V and L.V. for variation should be provided. The H.V. shall be connected Delta & Secondary with star connection. Earthing of transformer shall be as per IS 3043 & tender specification.
HT VFD panel for 6.6KV , 400KW motors Design, engineering, procurement, installation, testing and commissioning of HT VFD Panel suitable for 400 KW squirrel cage induction motor, 6.6 KV, 3 phase, 50 Hz with built in bypass terminal for pump control application as per tender specification. Harmonics at the supply side of the drive system at primary of the main input transformer shall be restricted within the maximum allowable levels of current and voltage distortion as per recommendations in the latest edition of IEEE 519.
LT PMCC Design, engineering, procurement, installation, testing and commissioning of MCC panel with totally enclosed type as per IS 2147 & IS 8623, operation on three phase,415V, 50Hz,neutral effectively grounded, IP 55, with instrument compartments indicating lamps, control contactors as per IS 13947,relays and control fuses air insulated . Incoming & Outgoing feeder details shall be as per Single line diagram & tender specifications. 800 Amp. EDO type, draw out ACB breakers as incomer feeder (2 Nos) , 800 Amp. EDO type, draw out ACB breakers Bus coupler (01 No) Outgoing feeder with S/D starter , Soft starter, DOL starter feeder & TPN MCCB/MCB etc. as per SLD Multifunction meter with RS 485 Compability with PLC-SCADA. Input Voltage- 3 phase 415 V (+/- 10 Percent) Input Frequency - 50 Hz (+/- 5 Percent) Starter Protection - S/C,u/Phase unbalance, Phase failureBuilt in communication as per RS 485 Under Voltage release type 415V Earth Fault Release EF1 (10 Percent, 20Peercent Ir) Door Inter Lock 110 V DC Control Supply Suitable for PLC -SCADA system
HT Power Cables Supply, laying, testing & commissioning 6.6 / 6.6 kV (UE) grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS: 7098 (Part- 2) & IEC 60502(Part-2) of following sizes: *6.6kV (UE) 11kV (E) 6.6KV (U/E) 3C X 300 Sq.mm , AL ,XLPE , armoured cable 11KV (U/E) 3C X 300 Sq.mm , AL ,XLPE , armoured cable
LT Power Cables & Bus Duct Supply, laying, testing & commissioning 1.1 kV grade, XLPE insulated, stranded Copper/Aluminium conductor, galvanised steel flat strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site requirement) conforming to IS 7098 (Part 1) & IEC 60502 (Part 1) of following sizes: (a) 1.1KV ,3.5C X 300 sq.mm. AL XLPE (b)415 LT MCC panel to ACDB, LDB & PBD,Outgoing Feeder (i) 1.1KV 3C X 2.5 Sq.mm Cu cable (ii) 1.1KV 4C X 6 Sq.mm Al cable (iii) 1.1KV , 4Cx10 Sq.mm Al , cable (iv) 1.1KV 3.5C X 70 Sq.mm AL cable
Cable Trays Supply , Installation, Testing and commissioning approved make Ladder/ Perforated C type cable tray. Made from pre- galvanized CR sheet steel. The cable tray should be bended as per IS 2062/1079 . with coupler plate / Fish plate and GI hardware like nut - bolt and washers etc. erected on existing support as per Specification and as per instruction of engineer in charge.Galvanised Iron Cable Trays. Including necessary supports, welding, insert plates, etc. complete with necessary bends, tees gross, covers, reducer, cover attachment, adjustable elbow, connectors & y branch, barrier strips and supporting ,erection hardware and accessoseries.make as per detail engineering & tender specifications. (a) 150 mm wide (Channel size 75X15X2 mm & runner size 35X15X2 mm) GI ladder type cable tray with GI couplers plate & nut bolts (b) 300 mm wide (Channel size 75X15X2 mm & runner size 35X15X2 mm) GI ladder type cable tray with GI couplers plate & nut bolts (c) 750 mm wide (Channel size 75X15X2 mm & runner size 35X15X2 mm) GI ladder type cable tray with GI couplers plate & nut bolts (d) 150 mm wide X 35X2 mm thick GI perforated type cable tray with GI couplers plate & nut bolts (e)300 mm wide 35X2 mm thick GI perforated type cable tray with GI couplers plate & nut bolts
Providing EARTHING & Lighting protection for Pump house, Electrical penel room, Out side Pump house area & Switchyard area equipments including Earthing pits, Electrode, GI Strips, MS Strip as per IS 3043 & IEEE 80 & tender specifications.
EXTERNAL LIGHTING [A] Supply , Installation, Testing and commissioning approved make steel tubular pole ( swaged ) confirming to IS -2713 & tender specifications , Pole should be painted by one coat of Zinc comet primer and two coat of Aluminium/approved paint to be erected on/it existing foundation, the length of the poles are as mention below. 9.0 Mtrs long swaged steel tubular pole (a) pole as per IS code , plate for burial erection (b) suitable foundation (c) primer and PU paint on the pole (d) Street light pole base (e) Pole foundation with pole earthing of suitable size (f) Cable clamps (g) Pole junction box (h) Street light bracket [B] Supplying and erecting MNES certified LED STREET LIGHT fitting made from dia cast alluminium body ,transparent cover with following LED lights & accessories. Complete with tubular battery, inverter, charge controller with photo sensor switch & necessary wiring complete erected connected & commissioned in approved manner of 36 watt suitable for volatge range of 90 to 300 voltage, 50000 hours working life, IP 67, suitable master box , 4KVA surge protection , THD less than 10Percent ,EMC compliance,Short circuit proof , over voltage and under voltage protection. (Street light shall be suitable for solar operated)
{C] Supplying and erecting MNES certified LED FLOOD LIGHT fitting made from dia cast alluminium body ,transparent cover with following LED lights & accessories. Complete with tubular battery, inverter, charge controller with photo sensor switch & necessary wiring complete erected connected & commissioned in approved manner of 100 watt suitable for volatge range of 90 to 300 voltage , 50000 hours working life, IP-65 fullyu weather proof , suitable master box , EMC compliance,Short circuit proof , over voltage and under voltage protection.
Internal Lighting & other accessories of Pump house building Point wiring ( Copper) Point wiring for Fan/ Light/Bell/ Primary point with 2 1.5 sq.mm (green ) both are of ISI marked 1.1 KV grade PVC insulated copper wires in exising pipe duly erected complete with 6 A Tissino type ISI marked flush type switch / bell push and accessories with earth continuity erected on polished wooden block / metal / PVC box covered with 3 mm thick laminated sheet for concealed wiring. Plug point ( 6 Amp) Single pole 16 Amp switch Single pole 6 amp & 16 Amp universal socket Conduicts & Pipe ( 25 mm) Maiins & wires 1.1KV garded FR PVC insulated ISI marked standard copper conductor wire of 2.5 Sq.mm
Supply erection of 1 X 40 watt T8 LED tublight with necessaries accessories suitable for 90 to 300 voltage variation, surface mounting , aluminium body, 25000 working hour ,suitable master box ,etc.
Supply erection of 1 X 12 watt LED down light with necessaries accessories suitable for 90 to 300 voltage variation, surface mounting , aluminium body, 30000 working hour ,suitable master box ,etc.
Providing & erecting of 1 X50 watt hi bay LED comprises die cast aluminium body with necessaries accessories suitable for 90 to 300 voltage variation, surface mounting , 30000 working hour ,suitable master box ,etc.
Providing & erecting Approved make Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C 50 Hz 1200 mm sweep complete having 3 blades aluminium body and blade sets having ornamental design shanks , canopy & 30 cms. down rod erected with 24/0.2, 3 core flexible wire with earthing. (Make shall be approved by Engineer in Charge]
Supplying & erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM 380 mm dia 900 RPM Cat II
Battery & Battery charger with DCDB Design, Engineering, procurement, Installation, Testing and commissioning of Battery and Battery charger 110 V, 300 AH sealed maintenance free battery (Lead acid battery) for DC power with float and boost type battery charger and DC distribution boards enclosures of 2 mm thick, IP 55 protection, louvers complete as per applicable standard & tender specifications.
Lighting & power distribution Panel board Supply , Installation, Testing and commissioning approved make LDB & PBD with TPN phase segregated DB comprising of CRCA sheet steel, double door, powder coated with provision of FP MCB/Isolator/RCCB as modular incomer & SP MCB as outgoing , IP-54 protection 8 way -Metal door
SAFETY ACCESSORIES (a)Providing and fixing printed instruction chart both in English and Gujarati and duly framed with front glasses, for treatment of person suffering from Electric shock with minimum 50" diagonally size.
(b)Providing pair of rubber hand gloves.
(c)Supplying rubber matting of following 12 mm thickness as per IS 15652 / IEC 61111
(d)Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti septic solution (Savlon or similar) etc. (All above contents shall be of standard makes)
(e)Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with dry-sand and kept on existing stand provided or hung on wall hook.
(f)Supplying & erecting floor mounting stand for keeping four nos.of FIRE buckets comprising 1500mm in length 900 mm height frame made out of Jomm x 30 mm x 4 mm angle iron with cross supports for legs,welded with 4 hooks and duly painted with one coat of red lead and two coats of approved enamelled silver paints
(g)Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. [B] For 5.5 / 6.5 KG Capacity
(h)Supplying & erection D.C.P type fire extingusher for following capacity cartridge type with gun metal cap 150 gram CO2 gas catridge ,powder and brackets confirming to IS 2171 1985 and complete eracted with necessery clamps made from 50 x 6 mm MS (1)For 10 KG Capacity
[A] TEST EQUIPMENT [B] Electrical Mandatory Spare Parts
Item Description
Pressure Transmitter Pressure measuring system at discharge header & individual pump pipe lines.Pressure transmitter having range of 0- 20kg/cm2 with Siphons, Manifold and SS 316 Fittings & tubing and compatible to GSM/GPRS modem connectivity.
Pressure guage Bourden type glycerin filled Pressure gauge having range of 0 -16kg/cm2, 150mm dial with syphone tube and isolating SS cock with accessories
Pressure Switch P.S at common discharge header pressure.
Ultrasonic type level transmitter Ultrasonic type level transmitter having range suitable to sump depth 0-10 M with separate indicator .
Conductivity type level switch (03 No.) for Level Low & Level Low Low & Level High alarm.
Poratble sound level meter
Portable meter for vibration measurement
Portable meter for temperature measurement
Instrumentation control panel with PLC & SCADA Instrumentation control panel with PLC (01 No.) Floor mounted front operated cubical panel board having IP 55 protection along with PLC, alarm Anuunciator with relay based for controlling of pumping station field instruments like flow meters, level transmitter, pressure transmitter, sound level meter, vibration meter & temperature indicator etc. Instrumentation system shall be redundant with 100 Percent hot back up. SCADA system cabine & its accessories Supply & erection of Computer based control desk for monitoring 2 Nos. of Industrial computer, printers & associated hardware & software, chairs, cupboard, 1no colour printer and 1 no 132 column dot matric printer suitable for extendable system as per tender specifications & drawing Un-interruptable power supply with nickel cadmium battery as per technical specification with back up power for 60 mini minimum or better. (01 Set).
Instrumentation & control cable along with cable glands,lugs,conduits, cable,cable trays & othe instllation hardwares
CCTV and DVR Supply and fixing / laying / installation & testing of following safety accessories complete with necessary fixing brackets, other accessories and tools etc. Comprising of 12 Cameras for Inside pump house, Surrounding area out side pump house, DVR, Hard disc, SMPS, UPS, mounting acessories etc.
Pressure Transmitter Pressure measuring system at discharge header & individual pump pipe lines.Pressure transmitter having range of 0- 20kg/cm2 with Siphons, Manifold and SS 316 Fittings & tubing and compatible to GSM/GPRS modem connectivity.
Pressure guage Bourden type glycerin filled Pressure gauge having range of 0 -16kg/cm2, 150mm dial with syphone tube and isolating SS cock with accessories
Pressure Switch P.S at common discharge header pressure.
Ultrasonic type level transmitter Ultrasonic type level transmitter having range suitable to sump depth 0-10 M with separate indicator.
Conductivity type level switch (03 No.) - for Level Low & Level Low Low & Level High alarm.
Poratble sound level meter
Portable meter for vibration measurement
Portable meter for temperature measurement
Instrumentation control panel with PLC & SCADA Instrumentation control panel with PLC (01 No.) - Floor mounted front operated cubical panel board having IP 55 protection along with PLC, alarm Anuunciator with relay based for controlling of pumping station field instruments like flow meters, level transmitter, pressure transmitter, sound level meter, vibration meter & temperature indicator etc. Instrumentation system shall be redundant with 100 Percent hot back up. SCADA system cabine & its accessories: Supply & erection of Computer based control desk for monitoring 2 Nos. of Industrial computer,printers & associated hardware & software , chairs , cupboard, 1no colour printer and 1 no 132 column dot matric printer suitable for extendable system as per tender specifications & drawing Un-interruptable power supply with nickel cadmium battery as per technical specification with back up power for 60 mini minimum or better.(01 Set).
Instrumentation & control cable along with cable glands,lugs,conduits, cable,cable trays & othe instllation hardwares
CCTV and DVR Supply and fixing / laying / installation & testing of following safety accessories complete with necessary fixing brackets, other accessories and tools etc. Comprising of 12 Cameras for Inside pump house, Surrounding area out side pump house, DVR, Hard disc, SMPS, UPS, mounting acessories etc.
Pressure Transmitter Pressure measuring system at discharge header & individual pump pipe lines.Pressure transmitter having range of 0- 10kg/cm2 with Siphons, Manifold and SS 316 Fittings & tubing and compatible to GSM/GPRS modem connectivity.
Pressure guage Bourden type glycerin filled Pressure gauge having range of 0 -16kg/cm2, 150mm dial with syphone tube and isolating SS cock with accessories
Pressure Switch :- P.S at common discharge header pressure.
Ultrasonic type level transmitter Ultrasonic type level transmitter having range suitable to sump depth 0-10 M with separate indicator .
Conductivity type level switch (03 No.) - for Level Low & Level Low Low & Level High alarm.
Poratble sound level meter
Portable meter for vibration measurement
Portable meter for temperature measurement
Instrumentation control panel with PLC & SCADA Instrumentation control panel with PLC (01 No.) - Floor mounted front operated cubical panel board having IP 55 protection along with PLC, alarm Anuunciator with relay based for controlling of pumping station field instruments like flow meters, level transmitter, pressure transmitter, sound level meter, vibration meter & temperature indicator etc. Instrumentation system shall be redundant with 100 Percent hot back up. SCADA system cabine & its accessories Supply & erection of Computer based control desk for monitoring 2 Nos. of Industrial computer, printers & associated hardware & software, chairs, cupboard, 1no colour printer and 1 no 132 column dot matric printer suitable for extendable system as per tender specifications & drawing Un-interruptable power supply with nickel cadmium battery as per technical specification with back up power for 60 mini minimum or better (01 Set).
Instrumentation & control cable along with cable glands,lugs,conduits, cable,cable trays & othe instllation hardwares
CCTV and DVR Supply and fixing / laying / installation & testing of following safety accessories complete with necessary fixing brackets, other accessories and tools etc. Comprising of 12 Cameras for Inside pump house, Surrounding area out side pump house, DVR, Hard disc, SMPS, UPS, mounting acessories etc.
Item Description
Price Schedule – G : SCADA works for all three Pumping stations (PS-1, PS-2 & PS- 3) OMS, RMS ,AMS & SCADA SYSTEM for entire command area field OMS System(Outlet Management System) & Entire SCADA System Design, engineering, procurement, installation, testing and commissioning of OMS System (Outlet Management System) Which includes enclosure, Electronically Operate Control Valve , isolation valve,Pressure transmmitter,strainer,control valve,Self Cleaning Automatic Secondary filters (130 micron), inlet manifold,outlet manifold,Flowmeters, RTU(Remote terminal Unit) & Gateway, Solar Panel with Included All accessories,Cable,cable glands etc as per the Specification and as Directed by Engineer in Charge.
RMS System(Remote Management System) Design, engineering, procurement, installation, testing and commissioning of RMS System(Remote Management System) Which includes enclosure Isolation valve, Air valve, strainer, Pressure transmitter, RTU (Remote terminal Unit) & Gateway, Solar Panel with Included All accessories,Cable,cable glands etc as per the Specification and as Directed by Engineer in Charge.
AMS System Design, engineering, procurement, installation, testing and commissioning of AMS System Which includes enclosure, Pressure transmitter, isolation valve, RTU (Remote terminal Unit) & Gateway, Solar Panel with Included All accessories, Cable, cable glands, etc as per the Specification and as Directed by Engineer in Charge.
Primary Filter Design, Supply, Installation, Testing & Commissioning of Primary Filters (200 microns) Including manifold + accessories as per the Specification and as Directed by Engineer in Charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SCHEDULE_B_TENDER_compressed.pdf
PART_1-1_SBD.pdf
PART_1-2_SBD.pdf
PART_1-3_SBD.pdf
PART_VOLUME_2_AB-1.pdf
PART_VOLUME_2_AB-2.pdf
PART_VOLUME_2_AB-3.pdf
PART_VOLUME_2_AB-4.pdf
PART_VOLUME_2_C-1.pdf
PART_VOLUME_2_C-2.pdf
PART_VOLUME_3_D-E.pdf
DRAWING-2.pdf
DRAWING-3.pdf
DRAWING_1.pdf
E Tender Notice No.23 of 2025-26.pdf
01 Vol 1 SBD.pdf
Enclosure-II-Vol-II(A).pdf
Enclosure-II-Vol-II(B).pdf
Enclosure-II-Vol-II(C).pdf
Enclosure-II-Vol-II(D).pdf
Enclosure-II-Vol-II(E).pdf
Price Bid_1 Vollume III.pdf
Price Bid _2 Vollume III.pdf
Price Bid _3 Vollume III.pdf
Price Bid _4 Vollume III.pdf
1 Enclosure IV Drawing.pdf
2 Enclosure IV Drawing.pdf
3 Enclosure IV Drawing.pdf
4 Enclosure IV Drawing.pdf
5 Enclosure IV Drawing.pdf
6 Enclosure IV Drawing.pdf
7 Enclosure IV Drawing.pdf
8 Enclosure IV Drawing.pdf
9 Enclosure IV Drawing.pdf
Co-ordinates Access for Borisavar LI.pdf
Nivida No.23 of 2025-26 lift Irri. Corrigendum No.1.pdf
E tender notice 23 of 2025_26 Corrigendum no.2.pdf
Addendum-1 Borisavar.pdf
Annexture-1 Borisavar.pdf
Corrigendum-3(07-01-2026)-Signed.pdf
Departmental Amendment Borisavar.pdf
Pre bid Query-(07-01-2026).Signed (1).pdf
up dated Annexture for reference Borisavar.pdf
up dated Corrigendum-3(07-01-2026)-Signed (1).pdf
up dated Pre bid Query-(07-01-2026).Signed (1).pdf
Corrigendum No.4 Nivida No.23 of 2025-26 lift Irri..pdf
Revised Corrigendum No.4 Nivida No.23 of 2025-26 lift Irri..pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .