Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹26.9 Cr
EMD Value
₹26.9 L
Closing Date
3 Feb 2026, 6:35 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy Municipal Commissioner, Gandhinagar Municipal Corporation (GMC), Gandhinagar
CONSTRUCTION OF CRICKET STADIUM, AT RANDHEJA IN GMC AREA
254997
116/2025-26
Open
Civil - All
Works
Gandhinagar
19 documents required · 19 mandatory
₹28,320
deputy municipal commissioner
₹26.9 L
18 Dec 2025
18 Dec 2025
18 Dec 2025
3 Feb 2026
18 Dec 2025
NAME OF WORK: CONSTRUCTION OF CRICKET STADIUM AT RANDHEJA IN GMC AREA
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Excavation for foundation upto 1.5 m depth including sorting out and stacking of
1 useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose Cum 1790.00 121.91
Excavation for foundation upto 1.5 m depth including sorting out and stacking of
2 useful materials and disposing off the excavated stuff upto 50 Meter lead.(B) Dense Cum 11.00 155.60
Excavation for foundation upto 1.5 m depth including sorting out and stacking of
3 useful materials and disposing off the excavated stuff upto 50 Meter lead.(C) Hard Cum 11.00 266.26
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and
4 stacking of useful materials and disposing off the excavated stuff upto 50 Meter Cum 952.00 134.95
lead.(A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and
5 stacking of useful materials and disposing off the excavated stuff upto 50 Meter Cum 11.00 168.81
lead.(B) Dense or Hard soil
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and
6 stacking of useful materials and disposing off the excavated stuff upto 50 Meter Cum 11.00 284.37
lead.(C) Hard Murrum
Add extra for Disposing off the excavated stuff of above items for lead of (A) 50 m to
Filling available excavated earth (excluding rock) in trenches. plinth, sides of
8 foundations etc. in layers not exceeding 20 cm. in depth consolidating each disposited Cum 3193.00 135.56
layer by ramming and watering.
Filling in plinth with sand under floors including watering ramming, consolidating
and dressing complete
Filling in foundation and plinth with murrum or selected soil in layers of 20cm.
thickness including watering, ramming and consolidating etc. complete.
Scarifying gravelled macadam or bitumen macadam surface 6 cm to 10 cm.depth
including stacking useful materials on road side and disposing off remaining stuff.
Construction of embarkment with approved material obtained from borrow pits with
all lifts and leads, transporting to site spreading, grading to required slope and
compacting to meet requirement to table 300-2, Construction of Embankment with
Material Obtained from Borrowpits area within 0.5 Km Lead
Carring out plinth treatment to post construction / existing structure by spraying
chemical solution for termite control treatment including labour and material
consistment with I.S.I specification. Using Chlordene and Chiorpurfiles 20 EC. As Per
13 6131_paret-II Consentration Weight one percent is recommended i.e one litre 20 EC Smt 1305.00 110.15
chemical emulsion with 19 liter give 1 % concrentration inclusive of one litre
chemical emulsion appication at the rate of 5 Litre chemical / Sqm of surface is
recommended as per I.S
Anti-Termite System:Providing and laying of permanent piping technology anti-
termite treatment before flooring work by installing LLDP (Low linear density
polyethylene) tube of 8 mm O.D. & 6.4 mm 1.D. with inbuilt pressure compensation
chip every 30 cm interval in the tube, having working pressure of 2 Kg/cm2 and
release rate of 1.9 Itr/hour fixed by P-clips and nails. The LLDP pipe shall be
installed at the entire periphery of the building and at internal network of building at a
depth of 20 to 200 mm under floor at every 2 to 3 mtr. c/c distance (adjusted as per
building layout ) & Ends of loop pass through a PVC elbow of minimum 32 mm ID at
junction box of wall and floor level, entering into a steel reinforced grooved flexible
pipe of minimum 22 mm ID leading into junction box and the loops shall terminate in
junction boxes & test every junction during injecting chemicals for termite control
treatment.The anti termite chemical Imidacloprid 30.5% SC mix as per IS-6313 (part
III) shall be injected by the prest not be renewed periodically.
Boring holes 3.5 m deep in ordinary soil (for cast in situ piles) and getting out the
15 soil and disposal of the surplus excavated soil as directed within a lead of 50 Meter Each 809.00 1545.73
for following diameter of pipes.(iii) 300 mm
Extra for under reaming inside the bore Holes for under reamed piles of following
Diameter.(iii) 300 mm
Add to or deduct from the rate for Bore Holes of 3.5 m Depth, if bore holes are
made deeper or shallower than 3.5M. for Piles of following diameter.(iii) 300 mm
Boring holes Max. 10.00 m deep with one bulb in ordinary soil (for cast in situ
18 piles) and getting out the soil and disposal of the surplus excavated soil as directed Rmt 1360.00 1730.00
within a lead of 50 Meter for following diameter of pipes.(ii) 400 mm
Providing and fixing in position Fe 415 TMT for R.C.C. bored piles as per detailed
19 drawing, including cutting, bending hooking tying and welding complete and including MT 11.00 63794.50
forming the cage and lowering it in position. (up to 10 ton)
Load testing of foundation piles including loading with necessary kentledge or any
other suitable method as directed.
Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8- hand
21 broken stone aggregates 40 mm nominal size) and curing complete excluding cost of Cum 315.00 2732.02
formwork in (A) Foundation and Plinth
Providing and laying controlled cement concrete M.250 and curing complete
22 excluding the cost of formwork and reinforcement for reinforced concrete work in (A) Cum 203.00 4303.84
Foundations, footings, Base of columns and Mass concrete.
Providing and laying controlled cement concrete M.250 and curing complete
23 excluding the cost of formwork and reinforcement for reinforced concrete work in (B) Cum 318.00 4610.97
Walls, from top of foundation level upto floor two level
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Providing and laying controlled cement concrete M.250 and curing complete
excluding the cost of formwork and reinforcement for reinforced concrete work in (C)
Slabs,landing,shelves,Balconies, Lintels, Beams, Girders and Cantilever upto floor
Providing and laying controlled cement concrete M.250 and curing complete
25 excluding the cost of formwork and reinforcement for reinforced concrete work in (D) Cum 147.00 4688.97
Columns, Pillars posts and struts, upto floor two level.
26 Extra and above for M250 to M300 Cum 1190.00 750.00
Extra for providing and mixing water proofing material in Cement concrete in
mix proportion recommended by the manufacturers.
28 Plasticizer 300 ml of 50 kg cement Ltr. 3571.00 25.42
Providing and laying controlled cement concrete M.150 and exposed work with
curing etc. complete including the cost of formwork but excluding the cost of
reinforsement for R.C.Cwork in (iv) Slabs having more than 13 cm and upto
30 Extra and above for item no:05029D for M300 for exposed work Cmt 527.00 1650.00
Providing formwork of ordinary timber planking so as to give a rough finish
including centering shuttering strutting and propping etc. Height of propping and
31 centering below supporting floor to ceiling not exceeding 4 M. and removal of the Sqm 1202.00 180.26
same for in situ reinforced concrete and plain concrete work in. (A) Foundations
Footings Bases of Columns etc. and Mass concrete.
Providing formwork of ordinary timber planking so as to give a rough finish
including centering shuttering strutting and propping etc. Height of propping and
centering below supporting floor to ceiling not exceeding 4 M. and removal of the
same for in situ reinforced concrete and plain concrete work in. (B) Flat surfaces such
as soffits of supspened floors slabs Landings and the like. (1) Floors etc. upto
mm in thickness.
Providing formwork of ordinary timber planking so as to give a rough finish
including centering shuttering strutting and propping etc. height of propping and
33 centering below supporting floor to ceiling not exceeding 4 M. and removal of the Sqm 923.00 443.21
same for in situ reinforced concrete and plain concrete work in. (G) Columns
PillarsPosts and struts. (2)Circular or curved in Plan.
Providing formwork of ordinary timber planking so as to give a rough finish
including centering shuttering strutting and propping etc. height of propping and
34 centering below supporting floor to ceiling not exceeding 4 M. and removal of the Sqm 2508.00 254.68
same for in situ reinforced concrete and plain concrete work in. (M) Staircase with
sloping or stepped soffits including risers and stringers excluding landing.
Extra for additional height of propping and centering where the height of propping
and centering exceeds 4 .O M between supporting floor to ceiling including temporary
brick or stone pillars for supporting as required. (i)Height more than 4.0 M.and upto
Extra for additional height of propping and centering where the height of propping
and centering exceeds 4 .O M between supporting floor to ceiling including temporary
brick or stone pillars for supporting as required. (ii) Height more than 5.0 M.and upto
Extra for additional height of propping and centering where the height of propping
and centering exceeds 4 .O M between supporting floor to ceiling including temporary
brick or stone pillars for supporting as required. (iii) Height more than 6.0 M. and
Extra for Providing formwork with sheathing steel sheets so as to give a fair finish
in (G) Columns, Pillars, Posts and struts. (2) Circular or curved in plan
39 Exposed Shuttering (Above Plinth) Sqm 4634.00 1950.00
Cement washing with portland cement slurry on wall surface (one coat) to give a
40 smooth finish including thoroughly broomings the surface to remove all dirt, mortar Sqm 1375.00 12.24
drops and other foreign Brand.
Extra over Item No. 18012 for every subseqent coat of cement washing with port land
Providing TMT Bar FE 415 reinforcement for R.C.C. work including bending,
binding and placing in position complete upto floor two level
43 Extra and above for Fe-415 to Fe-500D TMT MT 146.00 3000.00
Providing and applying anticarrasive treatment with polymer base materials to the
44 steel rainfarcement including descaling the dust and applying the preventive coating MT 145.00 4080.04
of approved make (for the R.C.C. structures near coastal area only) etc complete.
Brick work using common burnt clay building bricks having crushing strength not
45 less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cum 128.00 4550.73
Cement : 5 -fine sand) (A) Modular
Brick work using common burnt clay building bricks having crushing strength not
46 less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cum 11.00 4202.82
Cement : 5 -fine sand)(B) Conventional
Brick work using common burnt clay building bricks having crushing strength not
47 less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5. (1- Cum 1.00 4705.66
Cement : 5 -fine sand)(C) Fly Ash Bricks
Extra for brick work in superstructure above plinth level upto floor two level (A)
Extra for brick work in superstructure above plinth level upto floor two level (B)
(i) Half brick masonry in common brunt clay building bricks having crushing
50 strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand Sqm 43.00 613.94
) in foundation and plinth (A) Modular
(i) Half brick masonry in common brunt clay building bricks having crushing
51 strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand Sqm 1.00 623.56
) in foundation and plinth (B) Conventional
52 Extra for half brick masonry in superstructure above floor two level. (A) Modular Sqm 43.00 6.14
Extra for half brick masonry in superstructure above floor two level.(B)
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Masonary work using Aerated light weight concrete block having crushing strength
54 not less than 35 kg/sqcm for super structure above plinth level upto floor two level in Cum 1.00 4553.38
cement mortar 1:5 ( 1 cement : 5 fine sand ) complete as per Technical Specification
Extra for masonry work with precast concrete block in superstructue above plinth upto
floor two level.
Providing and fixing red brick cladding over concrete or brick/plastered wall surface
above plinth level, using cement mortar bedding and pointing, including surface
preparation, curing, and finishing, complete as per drawings, technical specifications,
and direction of Engineer-in-Charge.
Providing 10mm thick cement plaster in single coat on brick/concrete walls for
57 interior plastering upto floor two level and finished even and smooth in (i)Cement Smt 2375.00 133.96
mortar 1:3 (1-cement:3-sand)
Providing 10mm thick cement plaster in single coat on brick/concrete walls for
58 interior plastering upto floor two level and finished even and smooth in (ii) Cement Smt 1.00 102.73
mortar 1:4 (1-cement :4-sand)
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
59 single or half brick walls for interior plastering upto floor two level and finished even Smt 1.00 183.57
and smooth in (i) Cement mortar 1:3 (1-cement:3-sand)
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
60 single or half brick walls for interior plastering upto floor two level and finished even Smt 0.00 163.39 -
and smooth in (ii) Cement mortar 1:4 (1-cement :4-sand)
61 Extra over items 58 to 64 for finishing with a floating coat of neat cement slurry. Smt 2.00 50.12
(A) Extra over items 58 to 67 for providing and mixing water proofing materials in
cement mortar in proportion recommended by the manufacturer.
Extra over items 58 to 71 for plastering on ceilings and sofits of stairs upto floor
two level instead of plastering on walls.
Extra over items 1 to 69, 71 to 87 and 90 for interior plastering above floor two level
for every additional storey height. (1) Single coat plaster
Extra over items 1 to 69, 71 to 87 and 90 for interior plastering above floor two level
for every additional storey height.(2) Two coat plaster
Extra over item 91 for plastering on ceiling and soffits of stairs above floor two
level for every additional storey height.
Applying two coats of putty & two coats of primer of approved brand and
manufacture on new wall surface to give an even shade including thoroughly brushing
the surface free from mortar dropping and other foreign matter and sand papered
20mm thick sand faced cement plaster on walls upto height 10 metres above ground
68 level consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm Smt 4134.00 312.56
thick finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete.
69 Providing and laying Texture plater over base coat as per apporved sample. Smt 4134.00 575.00
Providing 20 mm thick double coat mala cement plaster on interior brick / concrete
work for plastering comprising of base coat of 12 mm thick cement plaster in cement
70 mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of Smt 110.00 283.27
cement mortar 1:2 (1 Cement : 2 Coarse sand) finished with trovel including
scaffolding curing etc. complete.
71 Providing throating or plaster drip and moulding to R.C.C. Chhajja. Rmt 11.00 43.31
Providing and laying cushioning layer on R.C.C. Slab consisting of 75mm thick lime,
72 concrete using brick aggregate of 20mm nominal size mortar compresing of 1- Lime : Sqm 97.00 246.41
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20 mm (average) base of
cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on existing
73 flooring by adhesive material including dismentaling of existing flooring and jointed Sqm 1510.00 1453.19
with color cement slurry including finised with flush pointing & cleaning the surface
etc. complete for antiskit
Providing and laying Vitrified tiles 8 to 10 mm thick , 24'' x 24'' in skrting risers of
74 steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and Sqm 624.00 1103.06
jointed with white cement slurry
75 Extra and above item no:14021A for STEEL GRAY GRANITE Flooring. Sqm 2133.00 2280.00
Providing and laying, Floor Carpet for pickal ball floor area as per approved sample
and make, as per directed by PMC/Engineers incharge.
White washing with lime on wall surface (two coats) to give an even shade
77 including thoroughly booming the surface to remove all dirt, dust; mortar drops and Smt 1.00 12.90
other foreign matter.
Cement washing with portland cement slurry on wall surface (one coat) to give a
78 smooth finish including thoroughly broomings the surface to remove all dirt, mortar Smt 1.00 12.24
drops and other foreign Brand.
Finishing wall with water proofing cement paint of on wall surfaces (Two coats)
to give an approved brand and manufacture and of required shape even shade after
thoroughly brushing the surface to remove all dirt and remains of loose powered
Extra over Item 18027 for every subsequent coat of water proofing cement paint of
approved brand and manufacture.
Wall painting (two coats) with plastic emulsion paint of approved brand and
manufacture on undecorated wall surface to give an even shade including throughly
brushing the surface free from mortar droppings and other foreign matter and sand
papered smooth.
Extra over item 18031 for every subsequent coat of wall painting with plastic
emulsion pain of approved brand.
APEX Exterior wall painting of approved brand and manufacture on undecorated
83 wall surface to give an even shade including throughly brushing the surface free from Smt 4134.00 380.00
mortar droppings and other foreign matter and sand papered smooth.
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Provoding and fixing flush door shutters, solid core construction with frame of first
class hardwood with cross board and face veneer or plywood face panels, including
84 anodised alluminium butt hinges with necessary screws. (B) Non-decorative type and Sqm 1.00 1811.62
block board core anodised alluminium butt hinges in flush door shutters (2) 35 mm
Add extra for providing and fixing 40mm thick shutters instead of 35 mm thick
shutters including oil paining etc. complete.
Providing and fixing full height Prelam PVC partition system 50mm thick
consisting of 40mm sand. M.S. angle. In between two M.S. angles 4 mm with
feathered edges shall be fixed on floor and 50 x 75 mm with feathered edges prelim
PVC “C” channel of size 50mm x 75mm with feathered edges prelim PVC panel shall
be inserted in the PVC ‘C” channel The first and last M.S. angle should be erected
such that it is inside a PVC C channel of size 50 x 75mm In between adjoining EPS
sandwiched PVC partition panel 4mm thick x 75 mm widthwich PVC panel made out
of 36mm high density expanded polystyrene sheet (E.P.S. Thermocol) stuck on both
side with 2mm thick prelim PvC sheet reinforced with frame work made from 35mm x
Providing and fixing full height Plan/colour PVC partition system 50mm thick
consisting of 40mm sandwich PVC panel made out of 36mm high density expanded
polystyrene sheet (E.P.S. Thermocol) stuck on both side with 2mm thick plain PVC
sheet reinforced with frame work made from 35mm x 5mm M.S. angle. In between
two M.S. angles 4 mm thick plan heat moulded PVC ‘C’ channel of size 50mm x
mm with feathered edes shall be fixed on floor and 50 x 75 mm with feathered edges
plain/printed/prelim PVC ‘C’ channel shall be fixed in the ceiling. Sandwich PVC
panel shall be inserted in the PVC “c” channel. The first and last M.S. angle should be
erected such that it is inside a PVC C channel of size 50 x 75mm. In between
adjoining EPS sandwiched PVC partition panel 4mm thick x 75mm width plain PVC
sheet feathered at edges shall be stuck on front and back face using solvent cement
etc. And additional 4mm thick PVC strip of 40mm width is to be stuck on the interior
side of the C channel using PVC solvent adhesive completATA/SAS hard drive
options, Data RAID Level: 0, 1, 5, 6, 10. Network: 4 x 1GbE sup
Providing and fixing full height Printed PVC partition system 50mm thick PVC
partition consisting of 40mm sandwich PVC panel made out of 36mm high density
expanded polystyred shet (EPS Thermocol) stuck on the both side with 2mm thick
printed PVC sheet reinforced with frame work made from 35mm x 5mm M.S. angle.
IN between two M.S. angles 4mm thick printed heat moulded PVC C channel of size
50mm x 100mm with feathered, edges shall be fixed on floor and 50 x 75 mm with
feathered edges printed PVC C channel shall be fixed in the ceiling, Sandwich PVC
panel shall be inserted in the PVC C channel. The first and last M.S. angle should be
erected such that it is inside a PVC C channel of size 50 x 75mm In between adjoining
EP sandwiched PVC partition panel 4mm thick x 75mm width printed PVC sheet
feathered at edges shall be suck on front and back face using solvent cement. If the
height of partition exceeds 8 feet; then 15mm x 30mm M.S. tube is welded
horizontally at the joint of panels in between two vertical angelsst not be renewed
Providing and fixing window having extruded aluminum Colour anodized section
frame main outer size 63.50 x 38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal
two track member size 61.85 mm x 31.75 mm x 1.20mm @ wt.of 0.695 Kg/mt,
vertical member of size 61.85 mm x 31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with
89 sliding shutters of horizontal member size 40mm x 18mm x 1.29mm @ wt.of Sqm 1.00 1696.73
0.456Kg/mt, vertical member of size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,
@ Wt. 0.457 Kg/mt with 5 mm thick transparent bronze colour tinted float glass with
powder coated aluminum fittings and fixtures and transparent silicon sealant glass
fixing to frame as per details etc complete for window.
Providing and fixing standared extruded of alluminium section of size 63.50 x 38.10 x
1.95 mm @ Wt 1.094Kg / Rmt with colour anodized alluminium frame with 5 mm
90 thick transparent bronze colour tinted float glass with colour anodized Sqm 106.00 1288.93
alluminium frame for ventilation with 5 mm thick frosted glass as details etc
complete for.window
Providing and fixing standared extruded of alluminium section of size 63mm x
91 38.10mm x 1.2mm @ Wt. 0.643 Kg/mt with colour anodized alluminium frame for Sqm 1.00 1163.92
ventilation with 5 mm thick frosted glass as details etc complete for Ventilation
Providing and fixing standared extruded of alluminium section of size 63.50 x 38.10 x
1.95 mm,@ Wt 1.094Kg / Rmt with colour anodized alluminium frame with 5 mm
thick transparent bronze colour tinted float glass as details etc complete for Fix
Providing and fixing of Door Closer with approved make, As per PMC/Engineers
Providing and fixing of Floor Spring with approved make, As per PMC/Engineers
95 Polycarbonate multi wall Roofing sheet Sqm 11.00 915.25
Providing and fixing M.S. grills of required pattern to wooden frames of windows etc.
96 with M.S. flats at required spacings and frame alround, square or round bars with Kgs 55.00 105.18
round headed bolts and nuts or by screws (A) Plain Grill.
Steel work, welded in built up sections framed work including cutting, hoisting,
fixing in position and applying a priming coat of red lead paint. (A)In beams and
97 joists, channels angles Tees, flats, with connecting plates or angle cleats as in Q 134.00 8750.00
main and cross beams. Hip and jack rafters, purlins conneted to common
rafters and the like
Steel work, welded in built up sections framed work including cutting, hoisting,
98 fixing in position and applying a priming coat of red lead paint. (D) In trussses and Q 1.00 8811.18
trussed purlins, upto 25 M. span and 15 M. ovarall height.
Providing and fixing M.S. Fan clamps type 1 to 16mm dia. M.S. bar bent to shape
99 with hooked ends to R.C.C. slabs curing, laying including painting the exposed portion No 11.00 130.98
of loops, all as per standard design complete.
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
M.S. bar bent to shape with hooked ends to R.C.C. slabs curing, laying including
painting the exposed portion of loops, all as per standard design complete.
Providing and fixing M.S. round holding down or anchor bolts with nuts and washer
plates complete.
Applying priming coat over new steel and other metel surface after and including
preparing the surface by throughly cleaning, oil,grease, dirt and other foreign matter
and scoured with brushes fine steel wood, scrapers and sand paper with ready mixed
priming paint brushing red lead.
Painting two coats (excluding priming coat) on new steel and other metal surface
with enamel paint, brushing, interior to give an even shade including cleaning the
surface an even shade including cleanicn the surface of all dirt, dust and other foreign
104 Extra over item 19002 for every subsequent coat of paint Smt 0.00 52.92 -
Painting two coats (excluding priming coat) on new steel and other metal surface
105 with synthetic enamel paint, brushing to give an even shade including cleaning the Smt 55.00 67.89
surface of all dirt, dust and other foreign matter.
Painting one coats (excluding priming coat) on previously printed steel and other
106 metal surface with synthetic enamel paint, brushing to give an even shade including Smt 55.00 45.98
cleaning the surface of all dirt, dust and other foreign matter.
107 Extra over item 19 and 21 for every subsequent coat of paint. Smt 0.00 45.64 -
Painting two coats (excluding priming coat) on external surface of new rain water,
soil, waste and vent pipes and fittings with ready mixed bituminous brushing, black,
anticorrosive to give an even shade including cleaning of all dirt, dust and other
foreign matter. (B) 75mm dia.
Painting two coats (excluding priming coat) on external surface of new rain water,
soil, waste and vent pipes and fittings with ready mixed bituminous brushing, black,
anticorrosive to give an even shade including cleaning of all dirt, dust and other
foreign matter. (C) 100mm dia.
Finishing wall with weather proof exterior emulsion paint on wall surface (two
110 coats) to give an required shape even shade after thoroughly brushing the surface to Smt 11.00 119.07
remove all dirt, and remains of loose powdered materials.etc complete
Providing and fixing post and pipe railing as per detailed drawing including 3 coats of
painting to steel works complete.
Extra and above item no: 27097A=12mmth Float Glass Railling in seating area with
112 all Stainless steel fixtures like supports pipes, Screws,Joints etc. as per instruction by Rmt 55.00 2590.00
PMC/Engineers. (upto 1.20 mt ht)
Stainless steel railling as hand rail of straircase both side with vertical supports with
all fixtures with all levels. Approved by PMC/Engineers incharge.
Proving, Suplying and fixing as per line and level as per drawing, A1 type fence
114 system, anti climb fence mesh size 76.2mmX12.7mm with 3mm wire diameter Smt 990.00 5500.00
PCC/TPC coated , As per approved sample by PMC/Engineers inchage.
Providing, supply and fixing HDPE pigion fish net with all fixture, tools for any level,
Providing and laying broken chine mosaic flooring for terrace using 12 mm to
mm broken pieces of glazed tiles to be laid over cement mortar 1:3 to plain or slope
116 and to be tempered to bring mortar creme out upto surface using white cement Smt 165.00 771.98
including rounding off junctions and extending them upto 15 cm along the
wall,clearing with water and oxalic acid etc. as directed.
Chemical water proofing in toilet sunk portion, As directed by Engineer incharge.
Pro. And fixing single layer water proof gypsum board 12.5 mm thick sections
using water proof board of size 1220 mm x 1830 mm x 8.0 mm suspended by GI
suspender channel of size 25 mm x 3 mm with intermediate channel og size 18 mm x
40 mm x 0.8 mm at 1220 mm center to center ceiling section of size 40 mm x 35 mm
x 0.55 mm at 457 mm c/c and perimeter channel A of size 20 mm x 27 mm x 30 mm x
0.5 mm at edges & drops incl.paper tap sand sofit cleat, anchor fastener, scoch bolt
connecting cleat,joining compound top coat on ceiling incl.making necy.opening for
light fitting,diffuser etc. comp. as per detail drawing as directed.
Providing upto floor two level precast cement concrete jali or grill 1:2:4 mix (1-
Cement : 2- coarse sand : 4-graded stone aggregate 6mm nominal size) reinforced
with 1.6 mm dia.Mild steel wire including roughening,cleaning, fixing and finishing in
cement mortar 1:3 and curing complete. (E) 100mm thick
Extra for additional lift for providing and fixing in position precast R.C.C. units above
floor two level
Providing cement vata (10cm. x 10 cm. size) quarter round in cement mortar 1:1
including neat cement finishing, watering etc. complete.
122 Paver block M250 Grade 60mm Thick (design approved by PMC/Engineers incharge) Smt 5060.00 377.12
Extra and above item no:967, for 75mm thckness, Matt finished colour paver block M-
124 Polycarbonate multi wall Roofing sheet Smt 440.00 915.25
PVC/FRP Gratings over drain around Stadium 30mmth, as per design and as
PMC/Engineers incharge.
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete
block 30cm length,30cm height and 15cm thick of M250 grade concret as per
approved design and including excavation for fixing in proper line and level,filling the
joint with C:M 1:3 (1cement:3fine sand) etc complete.
Supplying and fixing road sign board of M.S. plates and angle iron including
127 painting, lettering etc. complete including fixing in C.C. 1:4:8 with necessary Each 2.00 1860.38
excavation etc. complete as per I.R.C. type design.(i) Non - Reflective type
Supplying and fixing road sign board of M.S. plates and angle iron including
128 painting, lettering etc. complete including fixing in C.C. 1:4:8 with necessary Each 2.00 3042.56
excavation etc. complete as per I.R.C. type design.(ii) Reflective type
129 Labour charges for dry stone pitching 15 cm. thick including preparing the surface. Sqm 11.00 231.53
Laying brick soiling with over burnt traditional bricks including spreading of binding
130 materials murrum or earth etc. ( Bricks for soilng and binding materials shall be paid Cum 6.00 44.50
for seperately)(i) One layer laid flat.
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
131 (i) Supplying of murrum / binding materials Cum 6002.00 79.80
Cautionary Warning Sign :-Providing and fixing sing boards made out of 2mm
aluminium sheet; size 90 x 90 x 90 cms. equilateral triangle as per design of IRC-67-
1977. Pre treated with phospheting process & acid etching; coated with one coat of
epoxy primer and two coats of best quality epoxy paint ;reflectorised with retro
refiectivesheeting as per latest M.O.S.T.Specifications; 3.1m long stand postand frame
132 fabricated from suitable sizeiron angle of 35 x 35 x 3mm, 75 x 75 x 6mm as required; No 1.00 3474.53
painted with bestquality epoxy coatings in black andwhite bends. The details of
symbol foreach board shall be as per theinstruction of engineer in charge. The fixing
at site shall be in 1:2:4 CC blockof size 45 x 45 x 60 Cms. for each leg.including
excavation, curing etc.complete under the supervision of engineer in charge.(A)
Engineer Grade(VR)
Parking Sign :-Providing and fixing sign boards made out of 2mm aluminium sheet /
4mm ACP (Aluminum composite Panel); size size 60 x 60cms. square plus 60 x
20cms rectangular additional plate as as per the design of IRC-67-2012. Pre treated
with phospheting process & acid etching; coated with one coat of epoxy primer and
two coats of best quality epoxy paint ;reflectorised with Micro Prismatic Grade retro
refiectivesheeting of Type-11 as per ASTM D-4956 and latest
M.O.S.T.Specifications; 3.6mtr long stand post of 75 x 75 x 6mm / 65NB Circular
MS Pipe as required and frame fabricated from suitable size iron angle of 35 x 35 x
3mm; painted with bestquality epoxy coatings in black and white bends. The details of
symbol foreach board shall be as per theinstruction of engineer in charge. The fixing
at site shall be in 1:2:4 CC blockof size 45 x 45 x 60 Cms. for each leg.including
excavation, curing etc.complete under the supervision of engineer in charge. A
warranty for 10 years for the Retro reflective sheeting fATA/SAS hard drive options,
Data RAID Level: 0, 1, 5, 6, 10. Network: 4 x 1GbE supporting network throughput
of 800 MBPS, Standard VGA/HDMI Graphics Adapter, Windows 10/Windows
Server 2012/2016, Microsoft SQL Expr
Sign board per Squate Meter :-Providing and fixing sign boards made out of 2mm
aluminium sheet / 4mm ACP (Aluminum composite Panel); size 1meter x1 meter as
per design of IRC-67-2012. Pre treated with phospheting process & acid etching;
coated with one coat of epoxy primer and two coats of best quality epoxy paint
;reflectorised with Micro Prismatic Grade retro refiectivesheeting of Type-11 as per
ASTM D-4956 and latest M.O.S.T.Specifications; 4 mtr long stand post (2 Nos.) of
134 75 x 75 x 6mm / 65NB Circular MS Pipe as required and frame fabricated from No 1.00 12189.00
suitable size iron angle of 50 x 50 x 5mm; painted with bestquality epoxy coatings in
black and white bends. the details of symbol or inscription / numerals for each board
shall be as per the instruction of engineer in charge.The fixing at site shall be in 1:2:4
CC blockof size 45 x 45 x 60 Cms. for each leg.including excavation, curing
etc.complete under the supervision of engineer in charge. A warranty for 10 years for
the Retro reflective sheeting from originst not be renewed periodically.
Providing and laying PVC/Rubber based water stopper 230wide with all arrangement
as per drawing/PMC/Engineers incharge
P&L PVC Footrest for water tank arrange as per instruction as per drawing/PMC/Site
FlexStone flexible natural stone veneer cladding to curved exterior RC/structural
137 walls, including surface prep, primer, polymer adhesive, sheet cutting to templates, Smt 2200.00 28770.00
joint sealing, scaffolding/MEWP as required, curing/protection, complete in all
respects as per manufacturer’s specifications and Engineer-in-Charge. (Unit=Smt)
Steel work, welded in built up sections framed work including cutting, hoisting,
fixing in position and applying a priming coat of red lead paint. (A)In beams and
138 joists, channels angles Tees, flats, with connecting plates or angle cleats as in Q 550.00 8750.00
main and cross beams. Hip and jack rafters, purlins conneted to common
rafters and the like
Do- but Providing the following Grade MS strucutral framed work including cutting,
hoisting, fixing in position and applying a priming coat of red lead paint for flexstone,
Using Tubes Grad (Fy) 355 Mpa, RHS IS 1239 & 1161 for RHS & IS 4923 for
SHS, Anchor bolts confirming to ASTM A325 Type1
Electro Galvanized. for Grad(Fy)-250 Mpa confirming ASTM A36, Hight strenght
bolt Grad(Fy)635 Mpa for 12 to 24mm dia, Grad(Fy)560Mpa for 25 to 38mmdia.
all Febrication structural steel item for sand blasting with all tools and takels with
required safety measures complete by PMC/Engineers incharge
Providing and laying Primer (2 coats) and Polyurethane(PU)/Fluorocarbon
141 (FEVE)/Alkyd/Epoxy paints paint on Fabrication work as directed by Q 550.00 1696.71
PMC/Engineers incharge
142 Extra and above for, MS structure fixing for Flexstone, by Bolted Q 1.00 1100.00
143 Extra and above for, MS structure fixing for Flexstone, by Riveted Q 1.00 1100.00
Provding and supply, laying Project Name plate with Golden carving on Black
Granite in any launguage as per given sample/Drawing, back side 18mm water proof
ply and framing with teak wood batten around it as per drawing complete with line
Bore well work (upto 500ft depth) any kind of soil, including Boring in required dia,
Casing with all required tools, Insurting with required dia pipes, supply & installation
of 10HP pump/ Required Electrical pannel,fittings, wires, switches &Sockets etc with
complete, all civil works with all leads and lifes, testing & commissioning, at site
satisfactory with by PMC/Site incharge. (Consumable material as per Approved
Makes table, See-Annexure)
Providing erecting and fixing double coated ISI water tank of required capacity each
with all necessary fittings and connection etc. complete on terrace
ITC of European style water closet of Approved model by arch and client along with
147 PVC dual flush cistern and as per technical specification, and other accessories as Nos 10.00 17820.00
Vitreous European W.C Wall Mounted
Anti Bacterial plastic solid seat and seat cover with hinges & rubber buffers etc.
fixing of Water closet on wall with approved quality Fasteners/Chair Bracket , bolts,
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
100 dia PVC connector pipe from S / P trap to the junction of the soil stack or drain
with or without vent connection arrangement
Positioning & fixing of concealed flush tank with making 20mm dia water supply
inlet pipe connection from Treated water inlet and 32 mm dia pipe line from flushing
cistern to water closet
ITC of Approved make and model of table top mounted wash basin. Approved
model by arch and client, including drain connection and all other accessories require
to complete the installation like cast iron brackets and including following and
confirming to technical specification.
32 dia drain connection and extension piece with wall flang as shown in detail
drawing and other accessories require to complete the connection.
Approved CI bracket with two coat of primer and one coat of approved paint to
support and install wash basin with fasteners.
Making flexible pipe connection from angle valve to Tap / Mixture and fixing of
Bottle Trap / Flexible disposal pipes as per design drawing and specification.
ITC of approved make health faucet with 1.2 M flexible hose and hook (wall
bracket), all require screws etc. confirming to technical specification.
ITC of Stainless Steel Kitchen Sink of approved make. Including all accessories
150 require to fix the sink in granite or given platform and sealing side for leak proof, Nos 1.00
including following confirming to IS:13983 and technical specification.
40 mm heavy plated C.P. waste coupling fitting with or without pop-up waste
12 mm flexible hose connecting from angle valve to Tap
151 ITC of approved quality Basin Mixer for wash basin, including other accessories. Nos 10.00 2772.00
ITC of approved quality deck mounted sink cock for kitchen sink, including other
accessories and confirming to technical specification.
ITC of approved quality bib cock with wall flanges, including other accessories and
confirming to technical specification.
ITC of approved quality angle cock for flushing cistern, wash basin, washing
154 machine, and geysers with wall flanges, including other accessories and confirming to Nos 12.00 463.83
technical specification.
ITC of approved quality 2 Way bib cock with wall flanges, including other
accessories and confirming to technical specification.
ITC of approved quality concealed stop cock of below sizes for isolation of water
156 supply to toilet with wall flanges, including other accessories and confirming to
technical specification.
C SITC approved make and type Urinal with Sensor Nos 11.00 10500.00
Supply, laying, testing and commissioning of CPVC SDR-11 PIPE - conforming to
IS 15778 fittings suitable for domestic & flushing cold water application rated for a
working pressure of 5 kg/cm2 and conforming to latest Indian / International
Standards for exposed vertical / horizontal piping hung below ceiling above false
ceiling. Jointing of pipes with hold tite & teflon tape with necessary fittings, like
sockets, unions, reducers, long or short bends, elbows, nipples flanges, check nuts,
supported on G.I. brackets with pvc coated 'U' clamps etc. testing the pipes etc.
A 15mm(1/2") dia (internal) Rmt 95.00 224.05
B 25mm (1") dia(internal) Rmt 26.00 358.42
C 40mm (11/2") dia(internal & vertical) Rmt 40.00 534.60
D 50mm (2") dia(vertical) Rmt 603.00 886.71
E 80mm (3") dia (Sprinkler Network & Mains) Rmt 1120.00 2628.53
ITC of approved quality brass ball valve of following sizes with threaded ends, of
158.00 PN10 rating, Including all necessary accessory to fixing the valve to be fixed on
A For tapping from Loop to individual shaft
ITC of approved quality Butterfly valve of following sizes with threaded ends, of
159.00 PN10 rating, Including all necessary accessory to fixing the valve to be fixed on
A For Sprinkler network & Building supply lines
ITC of approved quality brass ball valve & non return valve of following sizes with
160.00 threaded ends, of PN10 rating, Including all necessary accessory to fixing the valve to
be fixed on cPVC pipe.
For over head Tank supply
SITC of approved quality PP Float valve of following sizes with threaded ends, of
161.00 PN10 rating, Including all necessary accessory to fixing the valve to be fixed on
uPVC pipe in side overhead water tank / electronic level controller switch.
Boring and Sinking Borewell up to 800 feet depth capable to deliver 25 to 30 cmt/hr
having 800 feet depth with 10" Dia. M.S. casing pipes & 3" PVC Cilumn Pipes as
per specifications by direct rotary drilling including aproved quality of media, screen
assembly etc. complete as per design, drawing & instruction if site encharge.
Providing & Installaing fully automatic HYPN Water Pressure Booster Pumping
System for ONLINE SUPPLY TO TOILET TAPS &/OR filling Over head tanks
having capacity to deliver 20 cmt / hour @ 4.5 Kg/cm2 working pressure as per
detailed specification sheet. (to be installed at Plant room)
Providing & Installaing SUBMERSIBLE PUMPS (1+1) with control panel board
for SPRINKLER IRRIGATION SYSTEM having capacity to deliver 40 cmt /
hour @ 5.5 Kg/cm2 working pressure as per detailed specification sheet. (to be
installed at Plant room)
Providing & Installaing POP-UP type SPRINKLERS DEGREE ADJUSTABLE
165.00 with all joinery & accessories capable of 15 Meter Raduis of Spray as per detail Nos 55.00 15100.00
irrigation layout plan (to be installed in Outfield)
SITC of PVC floor traps maintating 50mm water seal of self cleansing design with
166.00 water seal with including PVC removable grating setting the trap in 1:2:4 cement
concrete etc. complete. (Inside toilets , balcony area & wash area )
75mm (21/2") dia multi floor trap Nos 121.00 394.00
75mm (21/2") dia nahni Trap
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
SITC of PVC SWR TYPE B conforming to IS 13592:1992 from waste appliances to
floor trap with all fittings such as elbows, reducers etc., laying pipe in ledge wall and
slabs including all require supports, testing, making good the walls and floors
wherever required (Vertical lines in shaft)
A 50 mm (11/2") dia (internal) Rmt 198.00 290.00
B 75mm (21/2") dia (internal & vertical) Rmt 385.00 384.00
C 110mm (4") dia (internal & vertical) Rmt 935.00 606.00
D 160mm (6") dia (vertical) Rmt 402.00 1100.63
Constructing one brick this brick masonry chamber for housing PVC / stoneware
gully trap (9" x 6" Dia ) with 75 class designation bricks in cement mortar 1:4 (1
cement : 4 fine sand), including earth excavation, 100 mm thick bed concrete 1:5:10
168.00 (1 cement : 5 Fine sand : 10 graded stone aggregate 40 mm nominal size) and 25 mm
thick cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate
12.5 mm nominal size) including stoneware gully trap complete as per standard design
and as directed by the Engineer-in-charge.
constructing 600 x 600 internal size chamber with CI cover, frame and hold fast
including necessary accessories to complete the installation. Including stoneware gully Nos 7.00 6128.57
Constructing brick masonry inspection chamber in all type of soil with 75 class
designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand), R.C.C top slab
with 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size). Foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone
aggregate 40 mm nominal size), inside plastering 12 mm thick cement mortar 1:3
(1cement : 3 coarse sand) finished with a floating coat of neat cement and making
channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size) finished with a floating coat of neat cement complete as per
design including disposal of surplus earthwork within 5KM. lead as directed by the
Engineer-in-charge. for Sewer Pipe
A 750 x 750 mm chamber with medium duty cover Nos 4.00 14245.00
B 750 x 900 mm chamber with medium duty cover Nos 7.00 38185.71
C 900 x 900 mm chamber with medium duty cover Nos 1.00 58850.00
SITC of PVC SDR / Nu DRAIN / FOAM CORE HAVING GRADE - SN-8
CONFIRMING TO IS: 15328 pipes & specials as per line and levels specified in
drawings including excavation of trench,back filling ,leakage testing eighter by smoke
or water filling test outside basement area.
A 160 mm Dia (gt to chamber) Rmt 11.00 1293.00
B 200 mm Dia (chamber to channel) Rmt 50.00 1772.10
C 250 mm Dia (chamber to chamber) Rmt 10.00 2180.00
D 315 mm Dia (chamber to chamber) Rmt 10.00 2950.00
Boring and Sinking 50 cm. Diameter. Percolation well with casing pipes as per
171.00 specifications with installation of other equipments such as filtration chamber etc. Nos 1.00 434500.00
complete as per detailed drawing.
Providing, Installing & Testing of Float Operated Automatic type Mud Pump with
Control Panel Board as per detailed specification sheet
SITC of water tight Pre-Cast RCC Channel with heavy duty M. S. Top Grating
173.00 inside plastering as per standard design incl. excavation, back filling, etc. complete as
A 300 mm wide (basement & ground floor level) Rmt 1.00 3850.00
B 150 mm wide Readymade channel in 1st Basement Rmt 1.00 5280.00
C 600 mm wide Rmt 1.00 7150.00
SITC of Septic Tank & Soakwell for Domestic Sewage from Toilet blocks as per
detail construction & structural design : Volume : 50 CMT.
Supply,installation,testingandcommissioningof2MPFixed IR Dome Camera 1/2.8"
CMOS, Up to 1920x1080@30fps,Dual IR Cut Filter with Auto
Switch,Color:0.02Lux@(F2.0,AGCON), FixedProgressive Distance up to 30m,2.8
mmLens, Smart H.265+/H.265, DWDR, Tripwire, Perimeter VCA support, Built in
Support,G.711A/G.711U,4 regions Motion Detection,Mask Alarm,IP Address
Conflict ,ONVIF(PROFILE S/T/G),IP66,Surge Protection, Camera should support
external AI, NDAA comply,BIS
Supply,installation, testing and commissioning of 2MP Fixed IR Bullet Camera 1/2.8"
CMOS, Up to 1920x1080@30fps, Dual IR Cut Filter with Auto
Switch,Color:0.02Lux@(F2.0,AGCON), Fixed Progressive Distance up to 50m,4.0
mmLens, Smart H.265+/H.265,
DWDR,HLC,BLC,Tripwire,PerimeterVCAsupport,Builtin
Audio Support,G.711A/G.711U,4 regions Motion
Detection,MaskAlarm,IPAddressConflict,ONVIF(PROFILE S/T/G),IP67,Surge
Protection, Camera should support external AI, NDAA comply,BIS
Supply and installation of Network Video Recorder 40 Channel,connected camera at
up to 16MP resolution,1×HDMIand1×VGAIndependentoutputs,HDMI
Videooutputatupto4Kresolution,2SATAinterface,upto 10TB for 1 HDD, Smart
H.265+/H.265/Smart H.264+/H.2646MP,Bandwidth: Income 400Mbps; Outgoing
177.0 400Mbps,2 RJ-45 Ports (10/100/1000Mbps),ONVIF (PROFILE S/T/G),Alarm Nos 1.00 88500.00
I/O:16channel in;4channel out, Raid:JBOD,RAID0,RAID1,RAID5,RAID6,RAID10,
(Tripwire;DoubleTripwire;Perimeter;ObjectAbandon;Object Missing;Loiter;Running;
Parking;Lens Dignose;Scene Switch Dignose;Signal Abnormal Detection;Signal Loss
Detection;On Duty Detection;Crowd Detection) VCA support, BIS
Supply,LayingofCat6utpindoorcoppergreyGuage=24
179.0 Supply, Laying of Cat 6 d/c outdoor copper Rmt 660.00 65.00
Colour monitor of 17"
SupplyandLayingof 25mmdia.rigidLHSFTcategoryISI markedPVCconduitof1.6-
1.8mmwallthicknesswithall accessories complete with GI fish wire.
Carrying out necessary liosioning work with all concern
government / semi government departments for getting
181.0 power, approval of installation from electrical inspectors set 1.00 27500.00
office, etc complete including making - taking prints -submitting as built and other
necessary drawings.
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Construction of cricket pitch of size 22 yards (20.12 m) × 10 ft (3.05 m) including
subgrade preparation, 100–150 mm GSB sub-base, 75–100 mm sand base, 100–150
182.0 mm high-clay cricket soil block, rolling with 500–1000 kg roller, grassing with Sqm 62.00 8,500
Bermuda grass, crease markings, drainage provisions, surface finishing and all
complete as per tender specifications and direction of Engineer-in-Charge.
Supplying & erecting ABC powder type 'Ceasefire' type Fire extinguisher as per IS
13849 or 1 Kg capacity with necessary clamp for erection on wall
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following
184.0 capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts Nos 10.00 11,500
grouted in wall complete. [B] For 5.5 / 6.5 KG Capacity
Providing and Filling GOOD GARDEN BLACK SOIL Without void compacted soil
185.0 and as per compected measurement including all labour and transportation etc. Cum 1250.00 380
complete. For overall area levelling and mounds. For 300mm filling.
Providing and Filling GARDEN SOIL (KAAP) Without void compacted soil and as
186.0 per compected measurement including all labour and transportation etc. complete. For Cum 630.00 850
overall area levelling and mounds. For Top 150mm filling.
Providing and laying LAWN PLANTATION of Section 1 lawn with purhcase &
Mixing the soil with FYM @ 2 kg in 1 M2 Area, Area to be dressed very finely.
Plantation of 8 to 10cm c/c. for Out-side seating Area etc. Complete and
Maintainance included up to 1 Year after completion of Project.
Providing and laying Hybrid Bermuda type grass for stadium as per indian cricket
188.0 association cricket ground specification etc. Complete and ctting and levelled by laser Sqm 11150.00 410
machine. Also included Maintainance up to 1 Year after completion of Project.
Providing and laying CLERODENDRON INERME HEDGE PLANTATION (Tobe
planted on soil already area dressed or contoured ). Development of bed, plantation of
shrubbery including application of FYM 2kg in 1M2 Area, Average 6 plants in 1 M2.
Also included Maintainance up to 1 Year after completion of Project.
Providing and planting TREE PLANTATION of Vipin Ficus (Ficus benjamina) of 5'
to 6' height from top of pots or bags in pit size 45cmX45cmX45cm including Area
preparation. Excavation of pit 45cm x 45cm x 45cm depth mixing of FYM 2kg and
190.0 planting of plants. Tree plantation to be carried out neatly accurately and with No. 20.00 400
perfecton as per the design and drawing. Plastic bags or pots to be removed carefully
including staking tobe provided. . Also included Maintainance up to 1 Year after
completion of Project.
Providing and planting TREE PLANTATION of Terminalia (Terminalia arjuna /
Terminalia catappa) of 8' to 10' height from top of pots or bags and 2–2.5” girth in pit
size 45cmX45cmX45cm including Area preparation. Excavation of pit 45cm x 45cm
191.0 x 45cm depth mixing of FYM 2kg and planting of plants. Tree plantation to be carried No. 30.00 1,200
out neatly accurately and with perfecton as per the design and drawing. Plastic bags or
pots to be removed carefully including staking tobe provided. . Also included
Maintainance up to 1 Year after completion of Project.
Providing and planting TREE PLANTATION of Yellow Spathodea (Spathodea
campanulata) of 7' to 8' height from top of pots or bags in pit size 45cmX45cmX45cm
including Area preparation. Excavation of pit 45cm x 45cm x 45cm depth mixing of
192.0 FYM 2kg and planting of plants. Tree plantation to be carried out neatly accurately No. 40.00 900
and with perfecton as per the design and drawing. Plastic bags or pots to be removed
carefully including staking tobe provided. . Also included Maintainance up to 1 Year
after completion of Project.
Providing and planting TREE PLANTATION of Desi Champa (Plumeria rubra /
Plumeria alba) of 5' to 6' height from top of pots or bags in pit size
45cmX45cmX45cm including Area preparation. Excavation of pit 45cm x 45cm x
193.0 45cm depth mixing of FYM 2kg and planting of plants. Tree plantation to be carried No. 20.00 800
out neatly accurately and with perfecton as per the design and drawing. Plastic bags or
pots to be removed carefully including staking tobe provided. . Also included
Maintainance up to 1 Year after completion of Project.
Providing and planting TREE PLANTATION of Banyan Tree (Ficus benghalensis) of
10' to 12' height from top of pots or bags and 3–4” girth in pit size
45cmX45cmX45cm including Area preparation. Excavation of pit 45cm x 45cm x
194.0 45cm depth mixing of FYM 2kg and planting of plants. Tree plantation to be carried No. 1.00 6,500
out neatly accurately and with perfecton as per the design and drawing. Plastic bags or
pots to be removed carefully including staking tobe provided. . Also included
Maintainance up to 1 Year after completion of Project.
Providing and planting TREE PLANTATION of Galtora (Lantana camara) of 1'
height from top of pots or bags in pit size 45cmX45cmX45cm including Area
preparation. Excavation of pit 45cm x 45cm x 45cm depth mixing of FYM 2kg and
195.0 planting of plants. Tree plantation to be carried out neatly accurately and with No. 200.00 40
perfecton as per the design and drawing. Plastic bags or pots to be removed carefully
including staking tobe provided. . Also included Maintainance up to 1 Year after
completion of Project.
Providing and planting TREE PLANTATION of Date Palm (Phoenix dactylifera) of
8' to 10' height from top of pots or bags in pit size 45cmX45cmX45cm including Area
preparation. Excavation of pit 45cm x 45cm x 45cm depth mixing of FYM 2kg and
196.0 planting of plants. Tree plantation to be carried out neatly accurately and with No. 10.00 4,500
perfecton as per the design and drawing. Plastic bags or pots to be removed carefully
including staking tobe provided. . Also included Maintainance up to 1 Year after
completion of Project.
AMC of Landscape Area and plntation of whole project with neccesorry fertilizers
197.0 and manpower for maintainance, waterring, cultivation, cutting etc. for 2nd Year Job 1.00 12,50,000
after completion of Project.
AMC of Landscape Area and plntation of whole project with neccesorry fertilizers
198.0 and manpower for maintainance, waterring, cultivation, cutting etc. for 3rd Year after Job 1.00 12,50,000
completion of Project.
AMC of Landscape Area and plntation of whole project with neccesorry fertilizers
199.0 and manpower for maintainance, waterring, cultivation, cutting etc. for 4th Year after Job 1.00 12,50,000
completion of Project.
AMC of Landscape Area and plntation of whole project with neccesorry fertilizers
200.0 and manpower for maintainance, waterring, cultivation, cutting etc. for 5th Year after Job 1.00 12,50,000
completion of Project.
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Point Wiring no 116.00 505.05 5.05 510.10
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires, in following type of pipe to be erected concealed in/ on surface
on wall/ceiling complete with 6A Modular type switch / bell push &
201.0 accessories and earth continuity of following type, erected on PVC / Metallic
box, single mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed.
with medium class Rigid PVC pipe and accessories
Point wiring for secondary light point with 2-1.5 sq.mm & earthwire of 1.5 no 154.00 137.55 1.38 138.93
sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multistrand copper wires, in following type of pipe to be erected concealed in /
flushed on wall/ceiling, complete with earth continuity and necessary
connection with primary light with accessories erected on Metal / PVC box
covered with 3 mm thick PC(Polycarbonet) / Acrylic sheet for open /
concealed wiring. with necessary Lamp holder / ceiling rose / H.D.Connector
with medium class 25 MM DIA Rigid PVC pipe and accessories
Primary light point controlled by one SP MCB ( Same as above item but no 10.00 379.05 3.79 382.84
controlling with SP MCB )
Point wiring for FAN with 2-1.5 sq.mm & earthwire of 1.5 sq.mm (Green) no 32.00 701.40 7.01 708.41
both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multistrand
copper wires, in following type of pipe to be erected concealed in / flushed on
wall/ceiling complete with 6A Modular type switch and hum free EME four or
more step type electronic fan regulator with separately mounted and
204.0 accessories with earth continuity of following type erected on PVC / Metallic
box, single mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling
rose / H.D.Connector as directed.
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket no 26.00 267.75 2.68 270.43
erected on PVC / Metallic box, single mounting base frame covered with
205.0 textured / metallic front plate modules erected on / in wall / ceiling with
following type accessories
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both no 30.00 530.25 5.30 535.55
are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper
wires, in following type of to be erected concealed in / on surface of wall /
ceiling complete with Modular type switch & 5 pin Plug erected on PVC /
206.0 Metallic box covered with appropriate front plate modules erected on / in wall
/ ceiling as per pipe erected with following type of accessories.
[I] For 6A Plug with 2-1.5 sq.mm Cu. Wire
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both no 20.00 774.90 7.75 782.65
are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper
wires, in following type of to be erected concealed in / on surface of wall /
ceiling complete with Modular type switch & 5 pin Plug erected on PVC /
207.0 Metallic box covered with appropriate front plate modules erected on / in wall
/ ceiling as per pipe erected with following type of accessories.
[II] For 16A Plug with 2-2.5 sq.mm Cu. Wire
Wiring for the 250 volts single phase and neutral 16 amps switched no 5.00 906.15 9.06 915.21
socket outlet with 4.0 sq.mm FRLS flexible copper conductor 1100 volts
grade wires of approved make with concealed or surface mounted 25 mm
dia medium gauge PVC Conduit including providing and fixing of 16 amps
208.0 pin switch socket outlet of approved quality color make & design in 2 mm
thick GI box and earthing of fixtures and the outlet box with 2.5 sq.mm
PVC insulated copper conductor stranded flexible "FRLS" wire.
Providing & erecting Switch board for Computer or electric apparatus no 5.00 1,122.00 11.22 1,133.22
consisting of following items in single board erected on PVC / Metal board
with 3 mm thick PC (Polycarbonate) / Acrylic sheet erected as directed
1 no. 6A/16A universal plug-switch combined.
4 nos. 6A Switch
4 nos. 6A 5 pin Plug For Modular Type Accessories
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark Mtr. 1,500.00 33.00 0.33 33.33
(embossed) RIGID PVC PIPES of following size complete erected with
necessary PVC fittings & Junction boxes fixed with adhesive solution &
Clamps with following type of erection.2) For erecting concealed in RCC /
Brick wall/slab or Open along with continuous fish wire to draw mains, laid in
approved manner with plastering by cement mortar & finishing the surface to
match the wall/ceiling.
Supply and laying of 25 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark Mtr. 650.00 54.00 0.54 54.54
(embossed) RIGID PVC PIPES of following size complete erected with
necessary PVC fittings & Junction boxes fixed with adhesive solution &
Clamps with following type of erection.2) For erecting concealed in RCC /
211.0 Brick wall/slab or open along with continuous fish wire to draw mains, laid in
approved manner with plastering by cement mortar & finishing the surface to
match the wall/ceiling.
Supply and laying of 32 mm rigid PVC pipe of 1.6-1.8 mm thickness
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Providing and erecting 1.6 - 1.8 mm thick FIA approved and ISI mark Mtr. 250.00 67.00 0.67 67.67
(embossed) RIGID PVC PIPES of following size complete erected with
necessary PVC fittings & Junction boxes fixed with adhesive solution &
Clamps with following type of erection.2) For erecting concealed in RCC /
212.0 Brick wall/slab along with continuous fish wire to draw mains, laid in approved
manner with plastering by cement mortar & finishing the surface to match the
Supply and laying of 40 mm rigid PVC pipe of 1.6-1.8 mm thickness
Providing & erecting 1mm thick Steel Flexible Conduit with required nos. of Mtr. 250.00 45.00 0.45 45.45
coupling, steel bushes, Check-nuts etc. complete of following sizes.
Providing & erecting 1mm thick Steel Flexible Conduit with required nos. of Mtr. 2,600.00 70.00 0.70 70.70
coupling, steel bushes, Check-nuts etc. complete of following sizes.
Providing & erecting 1mm thick Steel Flexible Conduit with required nos. of Mtr. 100.00 100.00 1.00 101.00
coupling, steel bushes, Check-nuts etc. complete of following sizes.
MAINS : ( not for Point wiring ) mtr 50.00 438.00 4.38 442.38
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel,
relays, power switchgears, motor starters & control wiring) with required size
of copper lugs, nuts and bolts if required.
Supplying and Laying of 4 nos. of 10 sq mm Cu. FRLS flexible wires with
nos 4 sqmm Cu. FRLS flexible wires
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper mtr 50.00 258.00 2.58 260.58
conductor wire in following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
217.0 colour for earth continuity of following size
Supplying and Laying of 4 nos. of 6 sq mm Cu. FRLS flexible wires with
nos 2.5 sqmm Cu. FRLS flexible wires
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper mtr 50.00 146.00 1.46 147.46
conductor wire in following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
218.0 colour for earth continuity of following size
Supplying and Laying of 2 nos. of 6 sq mm Cu. FRLS flexible wires with
nos 2.5 sqmm Cu. FRLS flexible wires
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper mtr 50.00 111.00 1.11 112.11
conductor wire in following type of pipe to be erected in / on wall / ceiling with
2.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green
219.0 colour for earth continuity of following size
Supplying and Laying of 2 nos. of 4 sq mm Cu. FRLS flexible wires with
nos 2.5 sqmm Cu. FRLS flexible wires
Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper mtr 150.00 82.00 0.82 82.82
conductor wire in following type of pipe to be erected concealed in /flushed on
wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size
Supplying and Laying of 2 nos. of 2.5 sq mm Cu. FRLS flexible wires with
nos 1.5 sqmm Cu. FRLS flexible wires
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI mtr 100.00 62.00 0.62 62.62
marked stranded Copper conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green colour for earth
continuity of following size
(A) With medium class Rigid PVC pipe and accessories
(a) 2 wire 1.5 sq. mm
Distribution Board no 1.00 14,576.00 145.76 14,721.76
Supply, Assembling, grouting, leveling Connecting & testing D.B of IP 43 of
specified make.
222.0 Distribution Board-VTPN
Supply, Erecting, testing and commissioning of only VTPN D.B. PPI type with
space for FPMCB as incoming and space for DPELMCB and 8 TPMCB as
outgoing per phase (i.e. 8 way VTPN D.B.)
Supply, Erecting, testing and commissioning of only VTPN D.B. PPI type with 1.00 11,514.00 115.14 11,629.14
space for FPMCB as incoming and space for DPELMCB and 4 TPMCB as
outgoing per phase (i.e. 4 way VTPN D.B.)
Distribution Board-TPN no 2.00 13,483.00 134.83 13,617.83
Supply, Erecting, testing and commissioning of only TPN D.B. PPI type with
224.0 space for FPMCB as incoming and space for DPELMCB and 8 SPMCB as
outgoing per phase (i.e. 12 way per phase D.B.)
Supply, Erecting, testing and commissioning of only TPN D.B. PPI type with no 1.00 11,581.00 115.81 11,696.81
space for FPMCB as incoming and space for DPELMCB and 4 SPMCB as
outgoing per phase (i.e. 8 way per phase D.B.)
Distribution Board-SPN no 2.00 6,765.00 67.65 6,832.65
Supply, Erecting, testing and commissioning of SPN D.B. with space for
226.0 DPELMCB as incoming and 8 SPMCB as outgoing per phase (i.e. 12 way
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Supply, Erecting, testing and commissioning of SPN D.B. with space for no 2.00 2,124.00 21.24 2,145.24
DPELMCB as incoming and 4 SPMCB as outgoing per phase (i.e. 8 way D.B.)
providing and erecting Miniature circuit breaker single pole 0.5A to 2A system
228.0 and having breaking capacity 10 KA to be erected in existing box. confirming
to IS 8828/1996 with ISI Mark
Miniature circuit breaker single pole 6A to 32A suitable to operate on 240 V no 93.00 111.00 1.11 112.11
A.C. system and having breaking capacity 10 KA to be erected in existing box.
229.0 confirming to IS 8828/1996 with ISI Mark
6 to 25 A SP MCB
Providing & erecting 240 V MCB double pole switch for motor & inductive no 4.00 297.00 2.97 299.97
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
230.0 existing box having following capacity
6 to 32 A DP MCB
Approved make ELCBs / RCCBs conforming to IS: 12640 and having no 5.00 1,950.00 19.50 1,969.50
sensitivity of 30 mA and Short Circuit withstand capacity of 6 KA and suitable
for operation on single phase 240 V. having characteristic of quick action &
232.0 tripping with all advance feature & do not incorporate any electronic
component. for following Max. rating erected as directed
25 to 32A / 30mA DP ELMCB
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C no 5.00 590.00 5.90 595.90
Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box
236.0 having following capacity
6 to 32A FP MCB
Approved make four pole moulded case circuit breaker having breaking no 2.00 7,976.00 79.76 8,055.76
Capacity ICU of 35KA. At 415 V, having normal current rating up to 125A.
With fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s.
239.0 with all iternal connections & complete erected in existing 16 G.M.S. housing.
ICS= 100% of ICU only.
Approved make four pole moulded case circuit breaker having breaking no 1.00 16,061.00 160.61 16,221.61
Capacity ICU of 35KA. At 415 V, having normal current rating up to 200A.
With fixed thermal & magnetic release suitable to work on A.C. supply 50 c/s.
240.0 with all iternal connections & complete erected in existing 16 G.M.S. housing.
ICS= 100% of ICU only.
Supplying & erecting approved make Digital time switch having lithium cell 6 no 2.00 3,137.00 31.37 3,168.37
years operative and operate battery backup 1 channel day clock with
memory programme, suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD display. Also
comprised permanent ON/OFF switching. Programming switches & housed in
fire proof thermoplastic enclosure & transparent cover erected as required with
necessary connection erected as directed.
Supplying & erecting power contactor ,AC3 duty for time switch complete no 2.00 1,865.00 18.65 1,883.65
242.0 erected as per direction Cat III
(B) 2 pole 250V 32 Amp.
Supplying & erecting power contactor ,AC3 duty for time switch complete no 2.00 2,755.00 27.55 2,782.55
243.0 erected as per direction Cat III
(D) 4 pole 440V 40 Amp.
244.0 SITC of IP65 Polycarbonate enclosure for DP MCB no 2.00 1,720.00 17.20 1,737.20
245.0 SITC of IP65 Polycarbonate enclosure for FP MCB no 2.00 1,847.00 18.47 1,865.47
246.0 SITC of IP65 Polycarbonate enclosure for FP MCCB no 2.00 6,055.00 60.55 6,115.55
SITC Of 32A x 250 Volt single phase Power socket outlet point having IP no 2.00 8,648.00 86.48 8,734.48
247.0 rating of IP:65 at convenient location with MCB.for outdoor duty.
SITC Of 32A x 415 Volt three phase Power socket outlet point having IP no 2.00 9,428.00 94.28 9,522.28
248.0 rating of IP:65 at convenient location with MCB.for outdoor duty.
Providing & erecting ISI marked 3 pin plug top. no 5.00 21.00 0.21 21.21
Providing & erecting ISI marked 3 pin plug top. no 5.00 32.00 0.32 32.32
Cable Trench mt 500.00 55.00 0.55 55.55
Making trench in soft soil of suitable width of 90 cms deep for laying cable or
locating the fault all over the run and backfilling the same and making the
surface proper. Providing and erecting iron clad cable route marker duly
marked with ELE.CABLE of size 23 cms.X 12 cms. Flushed with ground in
cement foundation as directed by Engineer in charge. The width shall be as per
Covering of cable with second class bricks laid cover the cable crosswise & rmt 500.00 139.00 1.39 140.39
also on both sides with covering of 7. 5 Cms. layer of sand above & below
cable (cable shall be laid in 0.9mtr.deep & 0.4 Mtr.wide trench). Where there
are more than one cable in the trench on either side of the cable, 5 Cms. over
lapping of bricks shall be provided.
Providing cement concrete.for foundation or for concrete filling in 1:2:4 ratio Cu.mtr 10.00 5,077.00 50.77 5,127.77
with 20 to 25 mm stone metal duly plastered with necessary curing for pole
muffing or any other purpose.
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Providing burnt brick masonry with 1:6 cement concrete duly plastered Cu.mtr 10.00 3,772.00 37.72 3,809.72
including watering, stacking joint on exposed faces, rocking at joints on
exposed faces and watering complete
Construction of brick masonry pulling chamber 450 mm x 450 mm inside no 5.00 9,775.00 97.75 9,872.75
clear size and depth up to 0.6 meter with 350 mm thick masonry in cement
mortar proportion 1:5,cement finish cement plaster in CM proportion of
mm thickness from inside with 150 mm thick PCC at bottom with top slab
minimum 200 mm thickness in M20 grade with reinforcement. The rate shall
be inclusive of providing and fixing frame and 450 mm dia cover of FRC for
the Heavy Duty. Rate also inclusive of excavation and back filling & clearing
the site by removing debris & Shifting of the debris & making site good As per
the Instruction of the Engineer In charge complete in all respect.
Construction of brick masonry pulling chamber 600 mm x 600 mm inside no 10.00 10,925.00 109.25 11,034.25
clear size and depth up to 0.60 meter with 350 mm thick masonry in cement
mortar proportion 1:5,cement finish cement plaster in CM proportion of
mm thickness from inside with 150 mm thick PCC at bottom with top slab
minimum 200 mm thickness in M20 grade with reinforcement. The rate shall
be inclusive of providing and fixing frame and 600 mm dia cover of FRC for
the Heavy Duty. Rate also inclusive of excavation and back filling & clearing
the site by removing debris & Shifting of the debris & making site good As per
the Instruction of the Engineer In charge complete in all respect.
Construction of brick masonry pulling chamber 750 mm x 750 mm inside no 10.00 12,650.00 126.50 12,776.50
clear size and depth up to 0.75 meter with 350 mm thick masonry in cement
mortar proportion 1:5,cement finish cement plaster in CM proportion of
mm thickness from inside with 150 mm thick PCC at bottom with top slab
minimum 200 mm thickness in M20 grade with reinforcement. The rate shall
be inclusive of providing and fixing frame and 750 mm dia cover of FRC for
the Heavy Duty. Rate also inclusive of excavation and back filling & clearing
the site by removing debris & Shifting of the debris & making site good As per
the Instruction of the Engineer In charge complete in all respect.
Construction of brick masonry pulling chamber 1000 mm x 1000 mm inside no 20.00 17,825.00 178.25 18,003.25
clear size and depth up to 1.0 meter with 350 mm thick masonry in cement
mortar proportion 1:5,cement finish cement plaster in CM proportion of
mm thickness from inside with 150 mm thick PCC at bottom with top slab
minimum 200 mm thickness in M20 grade with reinforcement. The rate shall
be inclusive of providing and fixing frame and 900 mm dia cover of FRC for
the Heavy Duty. Rate also inclusive of excavation and back filling & clearing
the site by removing debris & Shifting of the debris & making site good As per
the Instruction of the Engineer In charge complete in all respect.
Cable Tray mtr. 10.00 866.00 8.66 874.66
Providing and fixing approved make Ladder type cable tray. Made from M.S
sheet. The cable tray should be bended as per IS 2062/1079 shall be fabricated
of double bended channel section longitudinal members with single bended
Channel section. Rungs of members welded to the base of tha longitudinal
259.0 members at 250 mm c/c spacing . as per IS and shall be coated with hot dip
galvanizing as per IS 2629/4759. with coupler plate / Fish plate and GI
hardware like nut - bolt and washers etc. erected on existing support as per
Specification and as per instruction of engineer in charge..
900 X 100 X 2 mm Thick
Providing and fixing approved make Perforated C type cable tray. Made from mtr. 50.00 158.00 1.58 159.58
CR sheet steel. The cable tray should be single or double bended as per
required and as per IS 2062/1079 and shall be coated with hot dip galvanizing
as per IS 2629/4759. with coupler plate / Fish plate and GI hardware like nut -
bolt and washers etc. erected on existing support as per Specification and as
per instruction of engineer in charge..
(2) 100 X 50 X 1.6 mm Thick
Fabrication kg 500.00 77.00 0.77 77.77
Supplying , fabricating and installation of various sizes MS race way / junction
boxes/clamps/hangers for Cable Tray, Light Fixture made out of specified size
sheet/Angle/Flat/rod/ channel etc as per design with all necessary accessories
like bend, junction boxes, coupler, Anchor fastener, Bolt Nuts, etc.. & work
from MS structure for other work with anchor fastener of Hilti make and
266.0 necessary hardware with necessary welding has to be done to complete the job
from ISA / ISMC / PLATE. The job also includes to paint the structure with
two coats of red oxide and two coats color of enamel paint as approved and
recommended by consultant. Complete in all respect to be installed at any
height with all necessary arrangements. Contractor has to complete the work
up to satisfaction of Consultant
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Aluminium conductor for 1.1 KV. to be laid on wall with necessary clamps or
in existing trench / pipe of following size of cables
300 sq.mm x 3.5c Al. XLPE Arm. Cable
269.0 185 sq.mm x 3.5c Al. XLPE Arm. Cable mt 30.00 896.00 8.96 904.96
270.0 95 sq.mm x 3.5c Al. XLPE Arm. Cable mt 350.00 486.00 4.86 490.86
271.0 70 sq.mm x 3.5c Al. XLPE Arm. Cable mt 50.00 375.00 3.75 378.75
272.0 50 sq.mm x 3.5c Al. XLPE Arm. Cable mt 50.00 282.00 2.82 284.82
273.0 35 sq.mm x 3.5c Al. XLPE Arm. Cable mt 50.00 218.00 2.18 220.18
274.0 25 sq.mm x 4 c Al. XLPE Arm. Cable mt 350.00 189.00 1.89 190.89
275.0 16 sq.mm x 4 c Al. XLPE Arm. Cable mt 350.00 152.00 1.52 153.52
276.0 10 sq.mm x 4 c Al. XLPE Arm. Cable mt 250.00 139.00 1.39 140.39
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
277.0 6 sq.mm x 4 c Cu. XLPE Arm. Cable mt 100.00 505.00 5.05 510.05
278.0 4 sq.mm x 4 c Cu. XLPE Arm. Cable mt 100.00 361.00 3.61 364.61
279.0 6 sq.mm x 3 c Cu. XLPE Arm. Cable mt 100.00 392.00 3.92 395.92
Providing & erecting XLPE(IS:7098) (I)-88 ISI armoured cable multistrand mt 2,500.00 285.00 2.85 287.85
copper conductor for 1.1 KV. To be laid on wall with necessary clamps or in
existing trench / pipe at road crossing or floor of following size cable.
4 sq.mm x 3 c cu. XLPE Arm. Cable
Supplying & erecting XLPE (IS:7098)(I)-88 ISI unarmoured copper cable 1.1 mt 1,200.00 213.00 2.13 215.13
KV grade to be erected as directed of following size
3 core 2.5 Sq.mm.
SITC of 10 Core X 4sq.mm. Cu. multicore armoured cable Round Unrmour mt 1,900.00 635.00 6.35 641.35
Cable Termination no 2.00 657.00 6.57 663.57
SITC of Cable end termination of the following XLPE insulated PVC sheathed
aluminum/copper conductor armored cables of 1100 volt grade including
283.0 supplying and fixing of bimetallic Long neck crimping lugs, double
compression type Brass glands with earthing.
300 sq.mm x 3.5c Al. XLPE Arm. Cable
284.0 240 sq.mm x 3.5c Al. XLPE Arm. Cable no 6.00 585.00 5.85 590.85
285.0 185 sq.mm x 3.5c Al. XLPE Arm. Cable no 2.00 397.00 3.97 400.97
286.0 95 sq.mm x 3.5c Al. XLPE Arm. Cable no 8.00 270.00 2.70 272.70
287.0 70 sq.mm x 3.5c Al. XLPE Arm. Cable no 2.00 197.00 1.97 198.97
288.0 50 sq.mm x 3.5c Al. XLPE Arm. Cable no 2.00 150.00 1.50 151.50
289.0 35 sq.mm x 3.5c Al. XLPE Arm. Cable no 2.00 150.00 1.50 151.50
290.0 25 sq.mm x 4 c Al. XLPE Arm. Cable no 24.00 111.00 1.11 112.11
291.0 16 sq.mm x 4 c Al. XLPE Arm. Cable no 10.00 107.00 1.07 108.07
292.0 10 sq.mm x 4 c Al. XLPE Arm. Cable no 8.00 90.00 0.90 90.90
293.0 6 sq.mm x 4 c Al. XLPE Arm. Cable no 6.00 62.00 0.62 62.62
294.0 4 sq.mm x 4 c Al. XLPE Arm. Cable no 6.00 57.00 0.57 57.57
295.0 6 sq.mm x 3 c Al. XLPE Arm. Cable no 6.00 56.00 0.56 56.56
296.0 4 sq.mm x 3 c Al. XLPE Arm. Cable no 6.00 51.00 0.51 51.51
SITC of Cable end termination of the following XLPE insulated PVC sheathed no 30.00 200.00 2.00 202.00
aluminum/copper conductor unarmored cables of 1100 volt grade including
supplying and fixing of bimetallic Long neck crimping lugs, double
compression type Brass IP65 glands with earthing.
10 sq.mm x 4c Al. XLPE Un.Arm. Cable
SITC of Cable end termination of the following XLPE insulated PVC sheathed no 108.00 200.00 2.00 202.00
aluminum/copper conductor unarmored cables of 1100 volt grade including
supplying and fixing of bimetallic Long neck crimping lugs, double
compression type Brass IP65 glands with earthing.
4 sq.mm x 10c cu. XLPE Un.Arm. Cable
MV Switchgear & Power Panels (TTA as per IEC 61439) - -
Supply, Unloading at site, shifting to site, assembling, leveling, grouting, - -
erecting, Testing, & Commissioning main L.T. panel board, fabricated from
M.S. sheet & folded channel totally enclosed cubical type compartmentalized.
Scope Covers Unloading at Site, Store in Weather Proof Condition, Shift to the
Location Basement / GF / FF, Grouting, Installation, Testing & Commissioning
complete in all respect & As per the instruction of Architect / Consultant /
Engineer Incharge. Scope also covers Co ordination with Panel Manufacturer.
Design, fabrication, assembling, supply, installation , testing of Panels for 415 - -
V, 3 phase, 50 Hz, 4 wire power supply system.
Panels shall be fabricated out of 2 mm thick CRCA sheet steel in cubical - -
formation, compartmentalized in Form 4b Construction, floor mounted, free
standing and shall be dust and vermin proof. 3 mm thick cable gland plate,
shall be provided both at the top and the bottom of the panel.
All large panels shall be provided with lifting hooks. Distribution panels shall - -
be fabricated in accordance with the specifications.
Note : Panel vendor has to provide Surge Protection at every stage of the - -
1) Supporting rigid steel framework. - -
2) Cubicle type, 14 gauge CRCA sheet steel enclosed. - -
3) Complete with interconnections and distribution bus bars. - -
4) Proper bonding to earth. - -
5) Painting/lettering on Breakers and distribution boards, the location they - -
serve, providing on each panel its circuit diagram.
6) Providing cable clamps / supports within distribution boards cable alley. - -
7) TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with - -
adequate size of neutral link.
8) All MCB’s shall be of minimum 10 KA breaking capacity. - -
9) The breaking capacity of MCCB’s are mentioned panel wise. - -
10) All motor feeders MCCBs shall be of motor duty. - -
11) Distribution panels shall be Powder Coated with Siemens gray paint shade - -
no. RAL-7032 of IS-5.
12) Degree of protection for following type of distribution panel enclosure - -
shall be as per IS:13947-1993.
a) IP 52 for indoor panels.
b) IP 54 for Service area panels.
c) IP 65 for outdoor panels.
13) All MCCB’s shall be provided with operating mechanism for door - -
interlock & with the roraty handle.
14) Current density of aluminium shall be 1 sq mm for 0.8 amps for rated - -
current of bus bars and current density of copper shall be 1 sq.mm for 1 amps
for rated current of bus bars.
15) Tinned copper earth bus as specified in the BOQ / SLD shall be provided - -
through out the length of each board.
16) All measuring instruments (Meters) shall be of digital electronic with LED - -
of approved make and compatible with BAS.
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
17) All hinged door shall be earthed through 2.5 sq mm tinned braided copper - -
18) All panels shall have provision of the following: - -
a) IP 55 for outdoor panels.
b) Pad locking of MCCB’s handles in “OFF” Position.
19) Additional set of C.T.s, potential free contacts, connectors, contactors with - -
wiring etc are to be provided for BAS including space required for various
transducers in Main Switch Board sections. Only transducers shall be supplied
by BAS contractor.
20) All the C.T.s should be auto short link type. - -
21) All the MCCB's should be with rotary handle. - -
22) All MCB’s used for protection of resistive and lightly inductive load shall - -
be type “B” characteristic and inductive (motor) load shall be of type “C”
characteristic and discharge lamps and UPS etc. shall be of type D
characteristic.
23) All incoming and outgoing air circuit breakers shall be placed on middle - -
portion of the vertical in single tier formation.
24) All PTs / control transformer shall be provided with centre tap earth - -
25) If Any descripancy found in SLD & BOQ, it should be brought in the - -
notice of the Client / Consultant, Client / Consultant's decision will be final in
case of any descripancy.
26) All outdoor panles should be provided with minimum 600mm height
fabrication stand with all side 2mm thick M.S. powder coated sheet.
26) G.A. Drawing should be checked & Finalised by consultant before - -
SITC of Main LT Panel (TTA as per IEC 61439) no 1.00 28,07,050.00 28,070.50 28,35,120.50
Incoming : From H.T Panel (Transformer-1)(Breaker-A)
630 amps FP MCCB (50 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP
3 Nos. of Digital type 0-400 / 5 amps CTR digital ammeter with 3 nos 630 /
amps, 15 VA Class I CT’s.
Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall
be protected by 2 amp TP MCB’s
630 amps FP Al. bus bars with coloured heat shrinkable insulated sleeve.
TVSS (100KA) Ten Mode 330 Series of ASCO Make Unit with 100A FP
MCCB as per SLD
Bus Coupler-1 (Breaker-B)
630 amps FP MCCB (50 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP
3 Nos. of Digital type 0-400 / 5 amps CTR digital ammeter with 3 nos 630 /
amps, 15 VA Class I CT’s.
Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall
Bus Coupler-2 (Breaker-D) - -
630 amps FP MCCB (50 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP
3 Nos. of Digital type 0-400 / 5 amps CTR digital ammeter with 3 nos 630 /
amps, 15 VA Class I CT’s.
Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall
be protected by 2 amp TP MCB’s
Incoming : From D.G. (Breaker-E)
630 amps FP MCCB (50 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP
3 Nos. of Digital type 0-400 / 5 amps CTR digital ammeter with 3 nos 630 /
amps, 15 VA Class I CT’s.
Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall
be protected by 2 amp TP MCB’s
400 amps 4 pole MCCB ( 36 KA ) : 4 Nos.
250 amps 4 pole MCCB ( 25 KA ) : 2 Nos.
100 amps 4 pole MCCB ( 16 KA ) : 2 Nos.
SITC of IP 65 Cricket Stadium Main Lighting Panel no 3.00 7,50,000.00 7,500.00 7,57,500.00
Incoming : From Main Panel
400 amps FP MCCB (36 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP
3 Nos. of Digital type 0-400 / 5 amps CTR digital ammeter with 3 nos 400 /
amps, 15 VA Class I CT’s.
301 Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall
be protected by 2 amp TP MCB’s
400 amps FP Tinned copper bus bars with coloured heat shrinkable insulated
TVSS (100KA) Ten Mode 330 Series of ASCO Make Unit with 100A FP
MCCB as per SLD
125 amps 4 pole MCCB ( 16 KA ) : 8 No.
Panel should be as per SLD
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
SITC of IP 65 high Mast Panel no 8.00 4,15,000.00 4,150.00 4,19,150.00
Incoming : From Main Panel
125 amps FP MCCB (16 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP
3 Nos. of Digital type 0-125 / 5 amps CTR digital ammeter with 3 nos 125 /
amps, 15 VA Class I CT’s.
Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall
302 be protected by 2 amp TP MCB’s
125 amps FP Tinned copper bus bars with coloured heat shrinkable insulated
TVSS (100KA) Ten Mode 330 Series of ASCO Make Unit with 100A FP
MCCB as per SLD
125 Amp FP ATS of ASCO make 300 series with overlapping Neutral
Incoming : From D.G. - -
125 amps FP MCCB (16 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP
3 Nos. of Digital type 0-125 / 5 amps CTR digital ammeter with 3 nos 125 /
amps, 15 VA Class I CT’s.
Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall
be protected by 2 amp TP MCB’s
40 to 63 amps 4 pole MCB ( 10 KA ) : 9 No.
6 to 32 amps 2 pole MCB : 42 no.
Panel should be as per SLD
SITC of Distribution Panel for Pavilion no 1.00 1,25,000.00 1,250.00 1,26,250.00
63 amps FP MCB (10 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP
3 Nos. of Digital type 0-63 / 5 amps CTR digital ammeter with 3 nos 63 /
amps, 15 VA Class I CT’s.
Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall
be protected by 2 amp TP MCB’s
63 amps FP Tinned copper bus bars with coloured heat shrinkable insulated
TVSS (100KA) Ten Mode 330 Series of ASCO Make Unit with 63A FP MCB
40 amps 4 pole MCB ( 10 KA ) : 4 Nos.
6 to 32 amps FP 4 pole MCB : 8 nos.
Panel should be as per SLD
SITC of 125KVAR APFCR Panel no 1.00 3,54,239.00 3,542.39 3,57,781.39
Design, Supplying, installing, testing of factory fabricated ready made Three
phase APFC Panel Cubical Panel fabrication should be type tested as per IEC
61921, 61439:1&2 Capacitor Duty Contactor for switching as per following
Steps Incomer Switch of MCCB type Icu=Ics=50KA at 400/440 Volts, with
OC, SC, internal earth fault protection Incomer Switch of MCCB type
Icu=Ics=50KA at 400/440 Volts, with OC, SC, internal earth fault
protection,Copper tinned insulated Busbar,Cubical panel should be indoor type
304 with IP 43 and IK 10,Metalized polypropylene film tye3-phase 550Volt
Capacitor,De tuning Reactor for each capacitor,Panel having Short Circuit and
Overload protection,Each step Capacitor having suitable MCB with Sc, OL,
internal earth fault relay,Each stage having Stage Contactor (Capacitor load
rating),PF regulator master controller having suitable steps with LCD display,
Rs 485 Communication port, Indication LED Lamps for main incomer and ON-
OFF for each capacitor bank,MS Chanel for Floor mounting, Cable entry as
per site situation,Cooling fans for panel
SITC of IP 65 External Area lighting Panel no 1.00 2,00,000.00 2,000.00 2,02,000.00
63 amps FP MCB (16 KA) with following accessories: 1 Sets
LED type Phase indicating & ON, OFF light shall be protected by 2 amps SP
3 Nos. of Digital type 0-63 / 5 amps CTR digital ammeter with 3 nos 63 /
amps, 15 VA Class I CT’s.
Digital type 0-500 Volt digital voltmeter with inbuilt selector switch & shall
be protected by 2 amp TP MCB’s
63 amps FP Tinned copper bus bars with coloured heat shrinkable insulated
TVSS (100KA) Ten Mode 330 Series of ASCO Make Unit with 63A FP MCB
40 to 63 amps 4 pole MCB ( 10 KA ) : 6 No.
6 to 32 amps FP 4 pole MCB : 2 no.
40 to FP Contactor : 6 no.
Dual channel Timer : 3 nos.
Panel should be as per SLD
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Light Fixture no 5.00 164.00 1.64 165.64
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more than 0.95, THD <
306 15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED
driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Tube Light with integral driver
(i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to no 35.00 370.00 3.70 373.70
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more than 0.95, THD <
15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED
307 LED driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Tube Light with integral driver
(iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to no 2.00 530.00 5.30 535.30
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with diffuser with
company mark/name 160V to 270V, Power Factor more than 0.95, THD <
15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED
308 driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of Wattage capacity
of LED fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Tube Light with integral driver
(v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to no 15.00 218.00 2.18 220.18
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure
die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting
309 required LM-79 & LM-80 Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20
(i) 5-9 watts,Surge-2 KV
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to no 5.00 423.00 4.23 427.23
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure
die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting
310 required LM-79 & LM-80 Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20
(ii) 11-15 watts, Surge-2 KV
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to no 170.00 584.00 5.84 589.84
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure
die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting
311 required LM-79 & LM-80 Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20
(iii) 16-20 watts, Surge-2 KV
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to no 5.00 751.00 7.51 758.51
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure
die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting
312 required LM-79 & LM-80 Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20
(iv) 22-24 watts, Surge-2 KV
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to no 5.00 1,777.00 17.77 1,794.77
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure
die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting
313 required LM-79 & LM-80 Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)
(B) LED Panel Light with provision for Plane front frame with translucent
cover fixed to housing complete.IP20
(vi) 36 watts, 24" x 24", Surge- 2KV
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to no 6.00 309.00 3.09 312.09
0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall
be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium pressure
die cast powder coated and high U.V. & corrosion resistance with diffuser
housed in aluminium casted body with company mark/name 160V to
270V,Power Factor more than 0.95, THD < 15 %, CCT 3000 K to 6500K,
314 Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 % ( fitting
required LM-79 & LM-80 Certificates)(NOTE: Below description have shown
ranges of Wattage capacity of LED fittings.The Engineer incharge may select
any wattage capacity between the ranges shown.)
(H) Mirror Light 9 Watts, wall mounted minimum 1 feet long
315 SITC of Any kind of Light Fixture with Basic Rate of Rs. 5000 no 10.00 5,980.00 59.80 6,039.80
316 SITC of Any kind of Light Fixture with Basic Rate of Rs. 10000 no 100.00 12,075.00 120.75 12,195.75
317 SITC of Any kind of Light Fixture with Basic Rate of Rs. 15000 no 50.00 17,825.00 178.25 18,003.25
318 SITC of Any kind of Light Fixture with Basic Rate of Rs. 25000 no 50.00 29,325.00 293.25 29,618.25
SITC of BIS approved LED floodlight luminaire with system power 960W (±
5%) , available in Cool White color temperature (5700K ± 355K as per ANSI
C78:377A) ,CRI≥70, SDCM<5 , LEDs used should have a life of
burning hrs. & lumen maintenance as per L70. The Luminaire System efficacy
should be of ≥100LPW. LED Luminaires must be equiped with BIS approved
driver, registered for flood lighting under BIS- CR Compulsory Registration
Scheme. The fixture housing must be Made of LM 6/ADC 12 PDC Aluminium
housing for rapid thermal management & Powder coated by Corrosion
resistant Nano coating powder coating process. Proper technical quality
documents for Nano-Technology powder coating should
be submitted by OEM compulsarily. Luminaire must have a Ingress protection
of IP66 and Impact resistance of IK-08 for housing and optical impact to be IK-
09. NABL approved certificate from OEM's own laboratory for IP test for
quoted luminaire must be submitted during tender. The fixture should have an
UV stabilized, Injection moulded special PC cluster lens optics ensuring low
glare & best in class uniformity. The luminaire housing compulsarily must have
3 separate modules each of 320W which are thermally and meachnically
isolated by a natural airgap and must have 3 separate integral driver
compartments for each respective module and should be formed into a single
maintanance for light Engines. The Luminaire must have thermally Isolated - -
Driver and Optical compartments separated by natural air gap for efficient heat
management and to ensure sustainable operation with dual air cross
conductivity, Driver should be placed in a thermally separate hingeable
compartment which is replaceable in the field condition with minimum Tools.
The light engine should have a suitable secondary optics to deliver desired light
distribution to meet the illuminance criteria. The Junction temperature of LED
shall be < 85 degree Celsius. Self-declaration from OEM certifying the above
technical parameters should be submitted along with technical bid during
tender. Thermal Test Report from
NABL approved/accredited lab must be submitted to support the same. The
luminaire must have Integral encapsulated high efficiency electronic driver
having a Aluminium extrusion housed construction with a wide rated voltage
range of 90-305V, Driver efficiency >90%, power factor > 0.95, THD < 10%.
OEM should submit own NABL accredited test reports along with technical
bid certifying for above mentioned operating voltage range, driver efficiency
test, power factor test and THD test. The driver must be compatible with
Inbuilt surge protection of 10KV and upgraded with integrated IP67 protected
SPD of 20KV/10KA surge protection within the driver compartment. The
minimum nett weight of the luminaire should be 30 kg or more. Driver should
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
declaration and technical data sheets of surge suppressor devices from OEM - -
certifying the above technical
parameters should be submitted along with technical bid during tender.
Luminaire performance & Safety :IEC 60598, IS 10322-5, IS 161-
03/05/06/07, Surge : IEC 61000-4-5, EMC : EN 55015. IES, LM 79, LM
& TTC certificates should be provided from OEM's own NABL accredited lab
along with the tender compulsarily. OEM should have their own manufacturing
facility in India for the supply of quoted street luminaires. Importing fixtures
from abroad and rebranding in India is strictly not allowed. The quoted lights
should have at least 80% components manufactured in India. Factory license
India of manufacturing unit for OEMs must be submitted during tendering.
Companies considered in quote, their place of manufacturing and affidavit that
percentage of component of fitting manufactured in INDIA must be submitted
along with the tender in softcopy and hardcopy. Manufacturer should have
their own NABL accredited testing laboratory for EMI-EMC test, Vibration.
compatibility test, Salinity spray test, wind load pressure test, IP / IK test, in
house powder coating facility, in house casting plant, robo-photometric
laboratory and Driver manufacturing facility, SMT line in India. The
Manufacturer Name and Logo should be engraved / Embossed on the
housing/body to allow traceability till the life of the fixture , No sticker will be
OEM should have own manufacturing facility for quoted LED fixtures in India - -
which should be functional for last 10 years and should have dedicated official
team for after sales and service support based out of Gujarat. Luminaire
housing bringing from land of border and branding in India and selling (except
LED hips/driver ) will be out rightly rejected. Certificate of country origin of
Products need to be given in the tender. Lighting manufacturer or country of
ORIGIN of manufactured Lighting should not be Land of Border or should not
be manufactured by direct or indirect by land of border origin company in
India. Official proof [at least 2 years or more] certifying OEM's lighting sales,
design & service maintenance office presence in Gujarat must be submitted.
The bidder shall submit an OEM Authorization Certificate issued by the
eligible manufacturer along with the tender submission to establish the
authenticity and validity of the offered products. Manufacturer should have
Certification pertaining to product Design Registration, CE certifications,
ROHS compliant, BIS certificate for drivers and luminaires
respectively.Certification: CE Certified, Design Patented/Registered, ROHS
compliant, BIS Certification for Luminaires & Drivers. Preference will be
given to OEM manufacturing products in India to promote “Make in India”
initiative of Govt. of India. Factory license India of manufacturing unit for
OEMs must be submitted during tendering. All Luminaires shall conform to
Supplying & erecting approved make low noise decorative exhaust fan having
320 size 200mm with 1350 RPM with square frame ABS body with inbuilt lowers
& square frame.
Supplying & erecting single phase approved make industrial exhaust fan no 2.00 2,034.00 20.34 2,054.34
suitable for medium duty ring mounted low noise operation suitable for
321 medium duty having following dia size and maximum speed in RPM
[A] 305 mm dia 900 RPM
Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with no 32.00 1,929.00 19.29 1,948.29
double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3blades with aluminium blades with , canopy &
cms. down rod erected with 24/ 0.2, 3 core flexible wire with earthing.(Make
shall be approved by Engineer in charge)
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe Mtr 32.00 107.00 1.07 108.07
down rod erected duly painted for fan complete with necessary 24/ O.20,
core flexible wire with earthing.
Street Light Pole no 10.00 10,069.00 100.69 10,169.69
Supplying and erecting approved make Conical Pole (Medium Duty ) Made
from HR sheet steel. The pole should be made as per IS. and shall be coated
with hot dip galvanizing as per IS 2629/2633/4759, with required base plate
and integral Junction box consist of terminal plate of min 6mm Hylam sheet,
324 standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type
terminal and arrangement for cable terminations as erected on suitable
foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given
by manufacturer considering site requirement. The length of poles are as
(D) 6 Mtr. Long 70 mm Top X 160 mm bottom dia, 3 mm thickness
Street Light Pole no 5.00 14,543.00 145.43 14,688.43
Supplying and erecting approved make Conical Pole (Medium Duty ) Made
from HR sheet steel. The pole should be made as per IS. and shall be coated
with hot dip galvanizing as per IS 2629/2633/4759, with required base plate
and integral Junction box consist of terminal plate of min 6mm Hylam sheet,
325 standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type
terminal and arrangement for cable terminations as erected on suitable
foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given
by manufacturer considering site requirement. The length of poles are as
(F) 8 Mtr. Long 70 mm Top X 190 mm bottom dia, 3 mm thickness
Supplying and erecting approved make Conical Pole (Medium Duty ) Made no 10.00 19,391.00 193.91 19,584.91
from HR sheet steel. The pole should be made as per IS. and shall be coated
with hot dip galvanizing as per IS 2629/2633/4759, with required base plate
and integral Junction box consist of terminal plate of min 6mm Hylam sheet,
standard profile 35mmX7.5mm Din-Rail for MCB Mounting, stud type
326 terminal and arrangement for cable terminations as erected on suitable
foundation (included) with necessary GI nut-bolts/J-Bolts. as per details given
by manufacturer considering site requirement. The length of poles are as
(H) 10 Mtr. Long 80 mm Top X 220 mm bottom dia, 3 mm thickness
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Providing and erecting Street Light pole bracket comprising main B Class MS no 10.00 620.00 6.20 626.20
pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm /80mm / required
size of pole top having sufficient fasteners for fixing the brackets and having
327 spread of 1.5.mtr. length with 110 deg.with vertical plane & suitable welded
stays, reducer and with check nuts complete painted with one coat of Red
oxide / PU base primer and two coats of Aluminium / PU paint. paint with
following nos of arms.
[A] Single Arm Bracket 1.5 Mtr
328 [B] Double Arm Bracket 1.5 Mtr no 4.00 907.00 9.07 916.07
329 [C] Triple Arm Bracket 1.5 Mtr no 1.00 1,204.00 12.04 1,216.04
Providing cement concrete.for foundation or for concrete filling in 1:2:4 ratio Cu.mtr 12.00 5,077.00 50.77 5,127.77
330 with 20 to 25 mm stone metal duly plastered with necessary curing for pole
muffing or any other purpose.
331 TMT Bar for Pole Foundation Kg. 750.00 75.46 0.75 76.21
Street Light Pole & High Mast no 4.00 20,58,730.00 20,587.30 20,79,317.30
Supply, Installation, Testing & Commissioning of 30 Mtr ( Height up to top of
the head frame) Fixed type Stadium High Mast with Head frame and platform
to support minimum 52 Nos of 0.9 to 1.2 KW Fixtures not more than 35Kgs
332 with driver. The high Mast shall be made of continuously tapered polygonal
sections of lengths to arrive at the specific height. The high mast shall be
structurally designed in accordance with technical report no 7 published by
institution for lighting engineer U.K. and to
withstand the wind speed of 158 km/hr. as per IS 875 Part III. The mast - -
section should be manufactured with special steel grade S 355 in compliance
with BSEN 10025. Each section of the mast shall be hot dip galvanized
through single dip process as per EN- ISO-1461:1999 and IS 11759-1985.
Average thickness of galvanizing shall not be less than 85 micron. All welding
shall be undertaken and performed as per BS 5135. The head frame shall be
made of suitable steel grade duly galvanized and equipped with suitable
provision for mounting of floodlights. Provision should be in the high mast for
man rider unit to access the light fixtures. All MS part including hardware shall
be hot dip galvanized as per BS729/BSENISO 1461 standard. Base section of
the high mast shall be provided with weather proof service door having vandal
resistance lock. Dimensional tolerance shall be as per BSEN 40. The
specification High Mast , thickness of section ( Bottom – 6mm , Middle -5
mm , Top -4mm ) with Dia Top-350mm , Bottom -880 mm , PCD-1000 mm
Base Plate-1120mm x 35 mm , with Bolt 16 Nos M39x850mm
(GA drawing of High mast Enclosed) with suitable earthing
Providing external man rider +unit for accessing the head frame.The unit shall no 2.00 13,46,650.00 13,466.50 13,60,116.50
be suitable for safe load carrying capacity of 300 kg with climb speed not
exceeding 9 m /min.
Lighting Control System no 1.00 4,74,490.00 4,744.90 4,79,234.90
Supply, Installation, Testing & Commissioning of DALI/Analog controller
for different scene creation as per lux levels required during different class of
play.Lighting control system should consist of following items
334 1.DALI / Analog Controller DDBC1200 – 4 nos
2.DDNG 1501 – 4 nos
3. User Interface- Similar to Philips Dynalite Antumbra- PA6BPE-WM-X +
SITC foundation of 30mtr height Stadium high mast including Design, no 4.00 4,15,000.00 4,150.00 4,19,150.00
335 Approval Excavation, Back filling, RCC, TMT, Foudation bolt complete in all
respect. (foundation as per OEM G.A. Approval)
Providing, erecting, testing commissioning & getting Plan Approval as well as
NOC from Electrical Inspector for extensible H.T panel comprising of one
630A/800A/1250A. H.T. VCB incoming & Two outgoing 630/800/1250 A
Drawout type VCB confirming as per I.S. for use on 11 KV, 3 phase, 50 c/s.
unearthed A.C. supply system having breaking rupturing capacity of 350 MVA
or Above complete with spring operated mechanism, mechanically &
automatic ON-OFF and spring mechanism charged, discharged indicators, ON-
336 OFF mechanical push button, operation counter necessary auxiliary switches,
closing shunt trip, air insulated busbar chamber having heat shrinkable PVC
sleeves, mechanical interlocks safety shutters, isolating plugs and a VCB trolley
with three vacuum interrupters with epoxy support insulators and self aligning
finger type isolating contacts. The breaker shall be Manual cum motorised
mechanism & auto spring charge with TNC switch closing with following
accessories. The Standared Companies Switchgear shall be Used and Only
Manufacutres as per IEC 61439 for beneficial use.
1.flush mounting type digital multifunctional meter with communication - -
facility - Three sets.
2. Power Factor Meter One No - -
3. Double core current transformer cast resin type having ratio 200 to 50/1 - -
core for metering & second core for protection having required class of
accuracy. - Three Sets
4. Instantaneous under voltage relay,Over Voltage relay & Temperature rise - -
5. Electrical closing coil & short trip coil operating on 110V. D.C.- Three Sets - -
6. Auxiliary relay for anti pumping device - -
7. Three phase Three limb Drawout type feeder connected & output of 200 - -
VA cast resin insulated potential transformer having ratio 12000V./110V. and
200 VA Burdon with 0.5 accuracy. - One No.
8. Common Alarm bell operating on 110V A.C.- One No. - -
9. Digital KWH Meter - One No. - -
10. Cable boxes suitable up to 11 KV 3core 150 sq.mm XLPE cable. - Three - -
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
11. 230V. A.C. to 110V. D.C. power pack for closing & tripping circuit - -
12.Breaker ON-OFF, Auto trip and spring charged indicators. - Three Sets. - -
13.Phase indicating & panel illumination lamps with plug socket - Three Sets. - -
14.Numerical Communicable type non directional O/C & E/F Relay with - -
a setting of 5-250% both in O/C & E/F. -Three Set
complete with necessary interconnection with air insulated high grade copper - -
busbar {Breaker Testing scope include Closing Time, Opening Time, VCB Hi-
Pot test at Site}{ Relay Testing Scope Include testing of all protection by three
phase testing kit at site }(VCB Trolley is to be provided)
Oil Type Transformer no. 2.00 6,71,586.00 6,715.86 6,78,301.86
Providing, erecting, testing & commissioning approved make oil immersed
ONAN cooled, double wound, core type indoor / outdoor copper wound
11KV/ 433V step down transformer of following capacities operating on
phase, 50 Hz 4 wire & neutral earthed system continuously rated for a full
temperature rise in oil not exceeding 45 Deg.C.at maximum ambient temp. of
50 Deg. C. complete with necessary radiator first filling of new transformer oil
337 & standard fitting as below complying with IS 1180( Part 1 ):2014 standards
with energy efficiency level 1 Off load tap changing range steps +2.5% to -5%
on H.V for variation should be provided. The H.V. shall be connected Delta &
Secondary with star connection. The transformer should have cable-end boxes
on H.T. side suitable for up to 3 core 150 sq.mm. XLPE cable & on L.T. side
suitable for bus duct or cables as per requirement complete with test
certificates from manufacturers
1. Oil conservator with filling Hole & Cap - One No. - -
2. Thermometer pocket with 6" dial type thermometer switch alarm & trip - -
contacts- Two nos.
3. Silica-gel breather with charge- One No. - -
4. Plain oil level gauge - One No. - -
5. Drain / Sampling / Filter valve - One No. - -
6. Top Filter Valve - One No. - -
7. Explosion vent with Diaphragm - One No. - -
8. Rating & Diagram plate - One No. - -
9. Additional neutral bushing for earthing - One No. - -
10. Bi directional Roller - Four Nos. - -
11. Earthing terminals - Two Nos. - -
12. Lifting lugs - Two Nos. - -
13. Air release plug. - One No. - -
14. Double float buchholz relay with Alarm and trip contacts. - -
15. Control cable as required from Transformer to VCB Panel is to be - -
provided with necessary connection to VCB relays for protection.
as per IS 1180 level-1 - -
Max. allowable loses at 50 % of rated load is 0.98 KW and at full load is
Providing and erecting ISI Marked 3core 240 Sq.mm XLPE insulated 11 KV mtr 200.00 2,196.00 21.96 2,217.96
armoured cable Aluminium conductor IS-7098 to be laid on wall with clamps
338 or in provided cable trench / pipe approved manner as directed.
Supplying and making cable end terminations for the following size of 11 KV no 8.00 12,685.00 126.85 12,811.85
grade, XLPE aluminium conductor armored cable including termination kit
339 complete heat shrinkable sleeve etc.
3 C x 240 sq.mm 11 KV XLPE cable (Outdoor)
SITC of following 1100 volts grade PVC insulated sheathed copper conductor mtr 80.00 442.00 4.42 446.42
armored control cables in existing trenches cables trays, clamped on wall with
suitable saddles, fixing bolts, including testing and commissioning.
340 12 Core 4.0 sq mm PVC insulated copper conductor armored control cables
SITC of Cable end termination of the following PVC insulated sheathed no 8.00 206.00 2.06 208.06
aluminium conductor armored cables of 1100 volt grade including supplying
and fixing of crimping lugs. Double compression glands with earthing
provision and cable sockets
12 Core 4.0 sq.mm Control cable
Supplying and erecting, commissioning and testing of Diesel Generating set
confirming to IS: 4722:1968 & BS:5514 having continuous rating, 3 phase,
415 volts, 50 cycles A.C. supply comprising of a totally enclosed air/water
cooled diesel engine with multi-cylinders developing suitable BHP not less than
following capacity at 1500 RPM with 10% overload for one hour in 24 hours
with standard accessories like fly wheel, lubricating oil cooler, "A" class
342 governor, heavy duty fuel wheel and lubricating oil filter, oil bath air filler,
lubricating oil pressure gauge, end exhaust manifold, standard set of tools with
adjustable spanners, screw drivers, cylinder head to cover, joint cylinder head
to exhaust, element lube oil filter, 12 / 24 volts electric starting equipment
complete with standard heavy duty battery, dynamo, cut-outs, ammeter,
necessary wiring, pressure gauge, starter etc and heavy duty Residential type
exhaust silencer (With DEF System) and vertical hot air duct both
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
logged with asbestos rope, save oil trays, exhaust piping of required length, - -
standard wall/floor mounted fuel with level indicator and piping and drip
proof alternator, self excited, self regulated, screen protected, with excitation
system, capable of delivering the rated system output at 415 volts, 3 phase,
PF, 50 Hz, 4 wire, running at 1500 RPM, conforming to IS-4722- 1968 with
voltage regulation +/- 5% of rated voltage from no load to full load. Both
the engine and alternator fitted on a common fabricated steel base plate with
antivibration mounting engine and alternator both connected to each other
by flexible flange coupling and with floor/wall mounted control panel box
comprising of voltmeter ammeter, selector switches, ACB / MCCB / MCB of
adequate capacity,
indicator lamps duly wired with HRC fuses. The alternator & control panel - -
shall be connected with provided suitable capacity armoured cable and
complete with Acoustic enclosure (canopy) made out of 16 SWG CRCA
Sheet, sound absorbing material Rockwool of 64 density & 100 mm thick
conforming to IS:8183 / PU Foam of 40 Density - at least 40 mm. The resin
bonded rockwool covered from inside the canopy by perforated sheet with 3/4
mm holes, sound level not more than 75 dB at a distance of 1 mtr, as per
PVCT norms.DG set should have in built fuel tank capacity of minimum 8 hrs
of continous running capacity on full load . Erection, commissioning and
satisfactory testing as per requirement with first filling of fuel (minimum up to
the 80% of fuel tank capacity), oil, etc. with guarantee / Warrantee of
complete system for Two years. & with obtaining all necessary certificate from
Electrical Inspector. The Capacity and Ratings of DG sets are as below. (As
per new CPCB4+ Emission norms Engine With - Turbo Charger, EGR
(Exhaust Gas Recirculation), CRS (Common Rail Fuel System), DOC (Diesel
Oxidation Catalyst), SCR (Selective Catalytic Reduction), Integrated wiring
harness connected to ECU .)
(S) Continuous rating of 320 KVA ,BHP not less than 375 BHP
Providing & erecting approved make AMF control panel suitable for following
size of 3 phase, 415 V., 50 cycles, A.C. diesel generating set complete of
scope as detailed below:
1) Power module: A pair of electromechanically interlocked contactors (for
mains & generator) Overload relay for generator contactor Neutral contactor
for mains and generator Power socket for connections.
2) Control and metering module: Line voltage monitor. Generator voltage
monitor Ammeter 3 items attempt start facility. Air circuit
343 breakers/MCB/MCCB of suitable rating for auto/manual operation.
Auto/manual switch. Emergency stop push buttons. Manual start push button.
frequency meter. Engine hour meter. Two earthing studs.
3) Protection module: The engine shutdown in the unlikely event of Low lube
oil pressure High cylinder head temperature. V belt failure.
4) Indicators with alarm Load on generator.
5) Indicators Load on mains Engine fails to start . Emergency stop battery
The AMF Panel of following capacity
(E) AMF Control Panel for 300 KVA/320 KVA3 phase DG Set
Supply, installation, Testing and commissioning of the following rating UPS
as per specifications and complete in all respects. Of APC or Emerson or Delta
SITC of 5KVA I/p-3 ph, O/p-3 ph. On line UPS with In built isolation
transformer & Battery back up as per specification..
a) Shop Drawings.
b) As-built drawings (including soft copy)
c) O&M Manuals (including soft copy)
344 d) Factory Testing and site testing as stated in scope
e) Freight & Insurance
f) Freight to job site (final site location)
g) Storage & site protection
h) 5 % Harmonic filter
i) SNMP /OC Web card, Multilink Software, Modbus protocol.
j) Complete Supply, Installation, Testing & Commissioning
Battery Back up for 1hr. per UPS
k) 1 hrs. individual back up battery bank warranted for 3 years.
l) DC Switchgear
m) Bypass switchgear
Supplying & erecting funnel type earthing having earth plate of following size
burred in specifically prepared earth pit 3 mtr. below ground with 40 kg.
charcoal and salt with alternate layers of charcoal & salt, 20mm.dia. G.I. pipe
with Funnel with a wire mesh for watering & bricks masonry block, C.I. Cover
complete as per para 7.3 of IS 3043 with necessary length of double
345 Galvanised Iron / copper earth wire No 6 SWG bolted with lug to the plate and
covered in 12 mm dia. G.I. pipe 2.5 mtr long complete connected to the
nearest switch gear with end socket as per direction & duly tested by earth
tester confirming to IS (As per drawing) with following specification
with 60 x 60x 0.315 cms. Copper earth Plate
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Supplying & erecting in earthpit of minimum bore dia. 225mm size ASH or no 4.00 5,785.00 57.85 5,842.85
approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of
80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having
200-250 Micron galvanising, connection terminal dia of 14 mm with
constant ohmic value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications.
346 For Electrical Installation covering Transformer Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive Computer System(like Automation,
SCADA)i.e. independent Earthing located in other than normal soil i.e.
Soft Rock, Marshy Soil etc..
[A] For electrical installation up to 440 V
Length of Pipe - 1 Mtr
Back filling compound - 1 Nos. of Bag of 15 Kgs.
Supplying & erecting in earthpit of minimum bore dia. 225mm size ASH or no 12.00 10,489.00 104.89 10,593.89
approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as
per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia of
80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having
200-250 Micron galvanising, connection terminal dia of 14 mm with
constant ohmic value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications.
347 For Electrical Installation covering Transformer Neutrals, Lightning arrester
Earthing, A.C.Plant & Sensitive Computer System(like Automation,
SCADA)i.e. independent Earthing located in other than normal soil i.e.
Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg.
Pipe type earthing with 40 mm dia 2.5 mtr long 'B' grade G.I. pipe with no 15.00 815.00 8.15 823.15
necessary coupling buch buried in specially prepared earth pit & G.I. earth wire
of 8 SWG erected & connected as directed (For pole)
Earth wire/strips : kg 2,000.00 77.00 0.77 77.77
Supply and laying cu. earthing strips for interconnecting the earthing stations,
panels, DB's etc. in built up trenches, on walls/ceiling, buried in ground
generally as specified and shown on drawings complete with : fixing
349 accessories
Corrosion protection of buried conductors with bituminous coating and
covered with PVC tapes.
Providing and erecting HOT deep Galvanised iron strip / wire 8 to 16 SWG.
Supply and laying cu. earthing strips / wire for interconnecting the earthing kg 505.00 787.00 7.87 794.87
stations, panels, DB's etc. in built up trenches, on walls/ceiling, buried in
ground generally as specified and shown on drawings complete with : fixing
350 accessories
Corrosion protection of buried conductors with bituminous coating and
covered with PVC tapes and with all type of Accessories
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed mtr 350.00 53.00 0.53 53.53
copper conductor with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically for control panel,
351 relays, power switchgears, motor starters & control wiring) with required size
of copper lugs, nuts and bolts if required.
Supplying and Laying mains with 1 no. of 6 sq mm Cu. PVC insulated FRLS
flexible wire ( Green Color Only )
SITC of Water Tight Junction Box of Hensel make Cat. No. KG9003IN With no 18.00 2,659.00 26.59 2,685.59
necessary clamp for mounting of the J.B. ( All the cable / wire connections to
the JB shall be with the Water tight Glands only )
Telephone Distribution no 1.00 985.00 9.85 994.85
Providing and installing of all conduiting and structured cabling for telephone
system including providing and fixing of the following:
1) All necessary specials and fittings
2) Approved cover plates for inspection, junction and outlet boxes.
3) 2 mm thick outlet boxes (MDF) and junction boxes.
4) All fixing accessories such as clips, nails, screws etc.
5) Providing and fixing approved saddles, hooks and grouting the same as
353 required, in the case of all exposed conduit work.
6) Embedding conduits and accessories in wall, floors etc. during
construction and / or cutting chases and making good as necessary in the case
of all concealed conduit work.
Supply and installation, testing and commissioning following size KRONE
make telephone tag block in lockable 16 gauge sheet steel enclosure complete
10 pair Krone type tag block
PVC & HDPE Conduits mtr 200.00 33.00 0.33 33.33
354 Supply & laying of 25 mm dia. rigid PVC conduit of 2.0-2.2 mm thick heavy
gauge with all accessories.
Supply & laying of 40 mm dia. rigid PVC conduit of 2.1 -2.3 mm thick mtr 20.00 67.00 0.67 67.67
medium gauge with all accessories.
Telephone Point Wiring mtr 100.00 40.00 0.40 40.40
Supply and laying of specified make 0.51 mm dia Tinned copper telephone
wire of specified make to be done in prelaid PVC pipe of 25 mm dia/raceway
356 of specified make, but without the cost of pipe or raceway. (the wire is to be
drawn from Krone connector of respective area to outlet point )
5 pair telephone wire
357 10 Pair Telephone Wire mtr 50.00 65.00 0.65 65.65
Supply, Installation, Testing And Commissioning of Solid Cable Cat 6, 4 pair, mtr 150.00 47.00 0.47 47.47
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Telephone Outlet Point no 3.00 159.00 1.59 160.59
SITC OF PowerCat 6 DataGate Jack, 568A/B - Yellow with Dust Cover /
Blank/ One Telephone Point to be done with Cat -6 Information outlet Socket,
Back Box, Face Plate for all telephone point. Average Length to be considered
359 as 50 Meter. Cable Laying, Labling, Ferrule, Testing, Certification to be
included in cost. 20 Years of Certification is required. Test reports of Level-4
Scanners only of make Legrand / Molex/ Systimax / Panduit / Siemon
SITC OF DG+ Jack (Diecast)Cat6A 568A/B, Shtd- Black (Information Outlet no 12.00 159.00 1.59 160.59
for Data) with Faceplate, back box CAT-6A standards. Cable Laying, Labling,
Ferrule, Testing, Certification to be included in cost. 20 Years of Certification
is required. Test Reports of Level-4 Fluke Scanners Only of make Legrand /
Molex/ Systimax / Panduit / Siemon
STIC OF 24 Port Layer 2 Fully Managed Network Switch with 24 no 2.00 30,275.00 302.75 30,577.75
361 10/100/1000Base T Ports and 4 GE SFP Ports. Include Limited Lifetime
362 Supply, installation, testing and commissioning of 24 Port loaded Patch Panel
363 Supply, installation, testing and commissioning of Patch Cord-1m No. 40.00 175.00 1.75 176.75
Supply, Installation, Testing and Commissioning of Equipment rack / Console No. 2.00 42,702.00 427.02 43,129.02
as per requirement
Supply, Installation, Testing & Commissioning of 5MP IP MFZ Lens IR
Rugged Dome Camera with minimum specifications as: Sensor Size: 1/2.8"
CMOS, Progressive Scan; Effective Pixels: 2592 x 1944; Lens:
2.7mm~13.5mm Motorized Focus & Zoom lens with Auto ICR (Infrared Cut
Filter); Frames: Max 50 FPS; Electronic Image Stabilization with G- Sensor;
Min. Illumination: 0.005 lux @ Color & 0 lux IR On; Electronic Shutter: 1/3 ~
1/100,000s; Smart IR with up-to 50m IR distance; Light Compensation: BLC,
HLC, WDR 130dB; Advance Video Compression: H.265 HEVC, H.264
MJPEG, Smart Codec; Streams: Four Video Streams configurable at different
Resolutions and FPS using H.265/H.264; Noise Reduction (3DNR); Minimum
Edge Intelligence: Motion Detection, Scene Change, Tamper Detection, Smart
Motion, Smart Intrusion, Smart Loitering, Smart Line Crossing Detection,
Unattended Object Detection, Missing Object Detection, People Counter,
Queuing, Crowd Gathering, Heat Map, Face Detection, Audio Detection,
Defog; 5 Privacy Mask and 6 ROI support; Security: Firmware encrypted &
Signed, SD card encryption, User account and password protection, HTTPS,
IP Filter, Digest authentication, Device Certificate, TLS 1.2 & 1.3, Stream
encryption, AES128/256, SSH/Telnet closed, PCIDSS compliance, Secure
boot, Prevent brute-force attack, Audit User Access/System/Event log
Supply, Installation, Testing & Commissioning of 5MP IP MFZ Lens IR Nos. 20.00 33,925.00 339.25 34,264.25
Rugged Bullet Camera with minimum specifications as: Sensor Size: 1/2.8"
CMOS, Progressive Scan; Effective Pixels: 2592 x 1944; Lens:
2.7mm~13.5mm Motorized Focus & Zoom lens with Auto ICR (Infrared Cut
Filter); Frames: Max 50 FPS; Electronic Image Stabilization with G- Sensor;
Min. Illumination: 0.005 lux @ Color & 0 lux IR On; Electronic Shutter: 1/3 ~
1/100,000s; Smart IR with up-to 70m IR distance; Light Compensation: BLC,
HLC, WDR 130dB; Advance Video Compression: H.265 HEVC, H.264
MJPEG, Smart Codec; Streams: Four Video Streams configurable at different
Resolutions and FPS using H.265/H.264; Noise Reduction (3DNR); Minimum
Edge Intelligence: Motion Detection, Scene Change, Tamper Detection, Smart
Motion, Smart Intrusion, Smart Loitering, Smart Line Crossing Detection,
Unattended Object Detection, Missing Object Detection, People Counter,
Queuing, Crowd Gathering, Heat Map, Face Detection, Audio Detection,
Defog; 5 Privacy Mask and 6 ROI support; Security: Firmware encrypted &
Signed, SD card encryption, User account and password protection, HTTPS,
IP Filter, Digest authentication, Device Certificate, TLS 1.2 & 1.3, Stream
encryption, AES128/256, SSH/Telnet closed, PCIDSS compliance, Secure
boot, Prevent brute-force attack, Audit User Access/System/Event log
management; Local Storage: 2TB Micro SD/SDHC/SDXC card slot; Alarm
Supply, Installation, Testing & Commissioning of Video Management Nos. 1.00 59,800.00 598.00 60,398.00
Software supporting ONVIF Profile S & G (Listed on ONVIF website), PSIA,
Real time streaming protocol (RTSP) standards, emerging technologies in the
industry, like 4K resolution, H.265 video compression codec, 3D PTZ control,
360° Fisheye camera and multi-imager/lens camera support. Software
proposed should be SQL based with at least 500 camera and 05 clients
included to view/record all the cameras, licenses should expandable up to
cameras & 10 clients without any additional version upgrade. N+1 redundancy
should be supported with proposed VMS. Vendor to consider and quote all
necessary additional software, Licenses and accessories required to make the
system functional.
Video Management Software shall support -
1) Perpetual software licence; must not be renewed periodically.
2) 2000 cameras management on single server instance.
3) N:1 and N:M recorder redundancy; application should also be able define
priorities among the redundant servers
4) Digital Signature and password protection on exported clips
5) Calendar Search with thumbnail image preview of recording and quick
export of video clips
6) Smart Motion Detection/Search on recorded video for multiple regions of
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Supply Installation Testing & Commissioning of Recording Server / Network Nos. 1.00 14,95,000.00 14,950.00 15,09,950.00
Storage Manager (NSM) supporting ONVIF Profile S & G, PSIA, real time
streaming protocol (RTSP) standards, emerging technologies in the industry,
like 4K resolution, H.265 video compression codec. System proposed shall
have scalability up-to 128 cameras per recorder with sufficient licenses to
record all the cameras in this requirement. It shall support simultaneous
recording, live monitoring, playback/search of recorded video for all cameras
supporting, support scheduled backfilling of the recordings from the edge
storage/SD card of cameras for robust recording against temporary network
failure. Recording to be considered for 30 days at full resolution, 25 FPS in
RAID 5. Vendor to submit storage calculations.
It shall have Intel® Xeon Silver 4210R 2.4G, Minimum 32GB RAM; Dual,
Hot-plug, Redundant Power Supply (1+1), 750W; OS drive: 2 (240GB) x M.2
Sticks Protected by RAID 1; 12 field upgrade 4 TB or 8 TB or 10 TB or
TB or 16 TB SATA/SAS hard drive options, Data RAID Level: 0, 1, 5, 6,
Network: 4 x 1GbE supporting network throughput of 800 MBPS, Standard
VGA/HDMI Graphics Adapter, Windows 10/Windows Server 2012/2016,
Microsoft SQL Express 2019. Standard VGA Graphics Adapter, 3 USB;
Certifications: UL, CE/EN, FCC, RoHS.
Supply, installation, testing and commissioning of VMS Server Hardware as Nos. 1.00 6,03,750.00 6,037.50 6,09,787.50
per following specifications: Intel® Xeon® E-2236 3.4 GHz, Chipset: Intel®
C246, Microsoft Windows® Server 2019 64-bit, Microsoft SQL
(Express or standard edition to be considered as per site requirement), System
Memory (RAM): 16GB DDR4, Hard Disk Drives: Dual (RAID1) 480GB
369 SSDs for OS; Network Interface Card (NIC): 2 x Gigabit Ethernet ports,
USB 3.0 ports, Human Interface: 102-key keyboard and a mouse pointing
device, Display Adapter: Matrox G200 or equivalent, Monitor Output: 1 x
VGA, Windows Media Player Version 12, Dual Hot-plug Redundant Platinum
power supplies, Certifications: UL, CE/EN, FCC along with UPS power,
associated cables etc complete as required.
Supply, Installation, Testing And Commissioning of 55" HD Monitor for Nos. 2.00 77,876.00 778.76 78,654.76
viewing the cameras
Supply, Installation, Testing and Commissioning of Equipment rack / Console No. 1.00 42,609.00 426.09 43,035.09
as per requirement
SITC of HP 2530-48G-PoE+ Switch, 48 10/100/1000 PoE+ ports, 4 SFP ports No. 1.00 2,25,614.00 2,256.14 2,27,870.14
372 382W PoE+ (J9772A) + 1 number of SFP Module of HP Make X121 1G SFP
LC SX Transceiver, MM, 850nm, 550m (J4858C)
Supply, Installation, Testing And Commissioning of Layer 2 Managed Gigabit No. 2.00 1,06,361.00 1,063.61 1,07,424.61
373 POE switch with 24 # 10/100/1000BaseT ports and 2 # Gigabit Combo
ports(RJ45/SFP), 2 # Gigabit SFP Port.
374 Supply, installation, testing and commissioning of 24 Port loaded Patch Panel
375 Supply, installation, testing and commissioning of Patch Cord-1m No. 40.00 175.00 1.75 176.75
Supply and laying of PowerCat 6A U/FTP CM 4 Pair Cable, LSZH Sheath - Mtrs. 4,000.00 47.00 0.47 47.47
Violet of specified make to be done in prelaid PVC pipe of 25 mm dia /
raceway of specified make, but without the cost of raceway or pipe ( the wire
376 is to be drawn from HUB \ Switch of respective area to outlet point ) with the
cost of the crimping with material of make Legrand / Molex/ Systimax /
Panduit / Siemon
Supply and laying of Cat-6 STP LSZH UV outdoor cable in PVC conduit with Mtrs. 200.00 58.00 0.58 58.58
termination as per TIA
378 SITC of 10 Core Single Mode Fibre Optic Cable Mtrs. 1,500.00 64.00 0.64 64.64
Design, Supply, Installation, Testing & commissioning of outdoor IP65 10 Job 1.00 1,21,90,000.00 1,21,900.00 1,23,11,900.00
mm Pixel Pitch Professional COB Active LED ( Display area 15 x 26 meter)
with Fabrication, Custom mounting bracket, Media Player & Signage
Software. Aspect Ratio 16:9 Resolution 3840 x 2160(UHD-4K), Contrast ratio
20000:1, , Android OS + 8GB RAM + 64 GB memory. Samsung / Delta /
Air Conditioning system Nos. 4.00 51,923.00 519.23 52,442.23
Providing and erecting approved make split air-conditioning unit consisting of
copper condensing unit with fan motor, hermetically sealed rotary compressor
with accessories etc. duly connected separately erected evaporating unit and
blower motor with its accessories by means of extra supplied proper insulated
380 copper tubing,drain PVC pipes suitable for ( cost includes powder coated
Stand, Eco Friendly green gas charging, 15A plug top & Remote Control) with
necessary core cutting.
(1)For ISEER Range (KWH/KWH)(3.1 to 3.99) Premium Category
(b) for 1.5 ton capacity
Supplying & installing MS standard type stand mounting for outdoor unit of Ea. 2.00 739.00 7.39 746.39
382 Split A.C. upto 4 TR capacity erected with necessary hardware materials as
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber Rmt 50.00 87.00 0.87 87.87
Supplying and erecting insulated pair of soft copper tubing open or concealed Rmt 50.00 956.00 9.56 965.56
including power and control cable,necessary PVC drain pipes for Split AC
machine up to 4 TR capacity
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber Rmt 50.00 87.00 0.87 87.87
Miscellaneous no 4.00 6,526.00 65.26 6,591.26
Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following
386 capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete.
For 4.5 Kg Capacity
Supplying rubber matting of following thickness as per IS : 15652/IEC61111 sq. mtr 20.00 3,051.00 30.51 3,081.51
Item No. Description Unit Qty Rate LC Rate Total Amount
Item No. Description Unit Qty Rate LC Rate Total Amount
Providing and erecting metallic vitrified danger notice board for MEDIUM no 5.00 69.00 0.69 69.69
VOLTAGE installation to be erected as per IS.
Providing printed instruction chart both in English and Gujarati and duly no 5.00 129.00 1.29 130.29
389 framed with front glasses, for treatment of person suffering from Electric shock
Providing & laying approved make Double walled corrugated pipes (DWC) of mt 1,200.00 62.00 0.62 62.62
polyethylene(conforming to IS 14930 II )with necessary connecting
accessories of same material at required depth for laying of cable. below
390 ground / road surface for enclosing cable and back filling the same to make
ground as per original.
MAINTENANCE FOR ELECTRICAL AND ELV WORKS year 1.00 21,29,513.68 21,295.14 21,50,808.82
Comprehansive Maintenance for Electrical Works
Provide annual maintenance service (including supply of material) and
393 operation for 3 years after handing over of work for electrical and ELV works
as per schedule including necessary materials to be given under warantee free
1st Year ( After 2 Year DLP Period)
394 2nd Year ( After 2 Year DLP Period) year 1.00 22,35,989.37 22,359.89 22,58,349.26
395 3rd Year ( After 2 Year DLP Period) year 1.00 23,47,788.84 23,477.89 23,71,266.72
Electrician & Technician for (Experience required in electrical & ELV) Month 12.00 38,832.00 388.32 39,220.32
complete Electrician In Each Shift ( for 3 Shift + 1 in general shift) . Biometric
Attendance or as per GMC latest norms to be submitted for payment.
396 1st Year Operation (During DLP Period) (2 Electrician)
397 2nd Year Operation & Maintenance (During DLP Period) (2 Electrician) Month 12.00 40,773.60 407.74 41,181.34
398 3rd Year Operation & Maintenance (After DLP Period) (2 Electrician) Month 12.00 42,812.28 428.12 43,240.40
399 4th Year Operation & Maintenance (After DLP Period) (2 Electrician) Month 12.00 44,952.89 449.53 45,402.42
400 5th Year Operation & Maintenance (After DLP Period) (2 Electrician) Month 12.00 47,200.54 472.01 47,672.54
complete 1senior Helper 2 Shift. Attendance sheet to be submitted for
401 Biometric Attendance or as per AMC latest norms to be submitted for
1st Year Operation (During DLP Period) (2 Electrician)
402 2nd Year Operation & Maintenance (During DLP Period) (2 Electrician) Month 12.00 39,831.35 398.31 40,229.66
403 3rd Year Operation & Maintenance (After DLP Period) (2 Electrician) Month 12.00 41,822.92 418.23 42,241.15
404 4th Year Operation & Maintenance (After DLP Period) (2 Electrician) Month 12.00 43,914.06 439.14 44,353.21
405 5th Year Operation & Maintenance (After DLP Period) (2 Electrician) Month 12.00 46,109.77 461.10 46,570.87
I/We am/are willing to carry out the work at ________% above/below percent (should be written in figures and words) of the estimated rate mentioned above. Amount of my / our
Estimated amount put to tender Estimated amount put to tender
Deduct____% below Add____% Above
In words In words
* Rates are exclusive of GST.
* For execution of work if any permission is required from any department, one liaison person shall be depute by contractor at his own cost. All proposal required for that shall
be prepared by contractor and GMC will issue only required documents. GMC will pay fees applicable to concern department only. This work being important the follow up
shall be taken from the very beginning of project.
* This work is required to carried out in Developed Urban area & having lots of underground utilities like water supply lines, Gas lines, drainage, Electric cables, OFC etc. If
any utility is damaged then it shall be responsibility of contractor and contractor have to rectify immediately. Without any extra charge to GMC. If any penalty imposed by
any department then it will have to be born by contractor.
* During execution of work any accident if occurs on site to labour or public then it will be the fully responsibility of contractor only & GMC will not be held responsible.
* Contractor is bound to follow all Govt labour existing laws & regulation and any changes in future.
The Deputy Commissioner
Gandhinagar Municipal Corporation (GMC),
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. SBD Book.pdf
CRICKET STADIUM ELECTRICAL LAYOUT.pdf
CRICKET STADIUM PLAN AT SEATING FLOOR LVL.pdf
CRICKET STADIUMPLAN AT MEZZANINE LVL.pdf
CRICKET STADIUMSECTION BB.pdf
CRICKET STADIUMSECTION CC.pdf
CRICKET STADIUMSECTION DD.pdf
E1 Electrical General Instruction.pdf
E2 Electrical Specification.pdf
E3 Item specification.pdf
PLAYER ROOM.pdf
Technical specifications 1.pdf
Technical specifications 2.pdf
Technical specifications 3.pdf
schedule B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .